PRASTEL M2000PE User manual

M2000PE ENGLISH ISM2000PEEU_02_05.doc
5
1. GENERAL DESCRIPTION
M2000PE is an access control unit for the operation of two doors.
It is equipped with an integrated 433MHz radio receiver, two inputs for external readers, two output relays with 5A-capacity contacts for direct
connection to the electric locks, and an internal memory with a storage capacity of 2000 user codes.
It is also fitted with 4 keys and a 4-digit display for code and functional parameter setting, and more precisely for
•programming new codes into the memory (through self-learning via the radio or the readers connected to the inputs);
•deleting single codes from the memory;
•selecting either bistable or timed operation mode independently for each relay;
•setting activation time for each relay (in the timed operation mode);
•associating any of the four channels of the radio transmitters to each relay;
•activating transfer of set data to another M2000PE unit connected via the RS485 serial line.
All operations can also be performed through the remote M/KEYB keyboard/display connected to the unit via RS/485.
All M2000PE circuits and components are housed in a plastic enclosure suitable for indoor installation and for mounting on bars according to DIN
standards. The M/KEYB keyboard is housed in an enclosure for wall-mounting or for countertop use.
2. TECHNICAL FEATURES
Power supply 12-24Vac/dc
Inputs integrated 433.92MHz radio receiver, 4 channels + 2 inputs with Wiegand protocol
Memory capacity 2,000 users
No. of output relays 2, controlled by two Wiegand inputs and/or by radio input, with the possibility of selecting channel address for each
relay. Example: channel 4 transmitter on relay 2.
Contact for enabling reading function on the door (one for each relay).
Inputs for forcing activation of the single door (“door opener” push-button)
Relay operating mode timed from 1 to 180 seconds
Relay contact capacity 5 A
Programming 4 keys (FUN, INC, DEC, VAL) and 4 displays plus M/KEYB remote optional keyboard/display
Other functions RS/485 serial communication port for transferring data to a slave unit and for connection of the M/KEYB remote
keyboard with 4 keys and 4 displays
Dimensions and weight 105x90x60, 320 grams
3. FUNCTIONS
Programming new codes
1. Simultaneously press keys INC and DEC.
2. Select a free storage location via keys INC and DEC (free location is indicated by decimal points being off).
3. Perform transmission or have the badge to be stored read by the badge reader (decimal points will go on).
4. Confirm by pressing key VAL (decimal points will briefly flash).
5. Repeat procedure from step 2 to enter other codes or simultaneously press keys INC and DEC to exit from programming mode.
Deleting codes
1. Simultaneously press keys INC and DEC.
2. Select the storage location to be deleted via keys INC and DEC (decimal points on indicate that the location is engaged)
3. Press the VAL key. The letter -C- will now appear on the left-hand side of the display.
4. Press the VAL key again to confirm deletion. The decimal points will go off and the storage location ‘h’ will be deleted.
5. Repeat procedure from step 2 to delete other codes and simultaneously press keys INC and DEC to exit from the programming mode.
Selecting operation mode and relay timing
1. Simultaneously press keys INC and DEC.
2. Press key FUN to access the function selection menu.
3. Select function F1 (relay 1) or F2 (relay 2) by pressing keys INC and DEC.
4. Confirm selection by pressing the VAL key; current parameter value will appear on the display.
5. Select the value to be assigned to the parameter by pressing keys INC and DEC. If value 0000 is set, the relay will operate in the bistable mode.
If a value between 1 and 180 is selected, the relay will operate in the monostable mode with activation time corresponding to the set value
(expressed in seconds).
6. Confirm by pressing key VAL; display will return to function selection and the new parameter will be stored.
7. Simultaneously press keys INC and DEC to exit from programming mode.
Assigning radio channel to the relay
1. Simultaneously press keys INC and DEC.
2. Press the FUN key to access the function selection menu.
3. Select function F3 (relay 1) or F4 (relay 2) by pressing keys INC and DEC.
4. Confirm selection by pressing the VAL key; current parameter value will appear on the display.
5. Select the desired radio transmitter channel (1, 2, 3 or 4) to be assigned to the relay by pressing keys INC and DEC.
6. Confirm by pressing key VAL; display will return to function selection and the new parameter will be stored.
7. Simultaneously press keys INC and DEC to exit from programming mode.
Entering the password
1. Access programming mode by pressing keys INC + DEC.
2. Press the FUN key to access the function selection menu.
3. Select function F5 by pressing keys INC and DEC and confirm by pressing the VAL key.
4. The letter P will appear on the left side of the display. Digit a sequence of six keys within 10 seconds. Each time a key is pressed, the letter P will
flash.
5. Upon the full sequence of six keys having been completed, the function selection menu will reappear on the display.
Failure to complete sequence within 10 seconds will abort password entry. This also avoids entry of incorrect passwords in case of any doubts as to
the sequence to be entered or erroneous pressing of any key.

M2000PE ENGLISH ISM2000PEEU_02_05.doc
6
The password is stored in EEPROM and is requested whenever INC+DEC are pressed to access programming mode starting from the stand-by
status (displays being off). In this case:
1. The letter P appears on the left side of the display. Digit the sequence of six keys corresponding to the password. Each time a key is pressed, the
letter P will flash.
2. Upon the 6-key sequence being completed, programming mode is accessed. If sequence is erroneous, the displays will go off.
Upon programming mode being accessed, any resident password may be deleted or replaced with a new one.
Note: To remove a password which has been forgotten, contact system supplier.
Deleting a resident password
1. Press INC+DEC to access programming mode: the password will be requested.
2. Digit in the password.
3. Press the FUN key to access the function selection menu.
4. Select the password entry function F5 by pressing keys INC and DEC and confirm by pressing key VAL.
5. Allow time-out (10 seconds) to elapse; password is deleted and will not be requested upon any subsequent accessing of programming mode.
Entering a set of codes
Entry of a set of codes avoids having to perform learning of all the transmitters or of all the badges in case of packages of 10, 50 or 100 pieces with
consecutive codes.
1. Access programming mode by pressing keys INC+DEC.
2. Press the FUN key to access the function selection menu.
3. Select function F6 by pressing keys INC and DEC.
4. Confirm by pressing the VAL key. Request of the first location to be programmed will now appear, default value being 0001. Only the first
decimal point to the left will appear indicating that the initial location is being selected.
5. Select location by pressing keys INC and DEC, and confirm by pressing the VAL key.
6. Request of final location to be programmed will now appear. The value shown is the one which has been previously selected as the initial
location so that only a value greater than this can be selected by pressing keys INC and DEC. The last decimal point to the right will now appear
indicating that the final location is being selected.
7. After selection of the final location, confirm by pressing the VAL key. The M2000PE will now set itself up to accept transmission of a code. Once
code has been received (via radio or any of the connected readers), it is entered in the initial location. All subsequent locations up to the final
one may be entered with codes obtained by increasing the initial code by one unit.
Example: initial location = 120, final location = 127, received code = 112233
Upon all locations having been entered with the code, system will return to the function selection menu.
Deleting a set of codes
1. Access programming mode by pressing keys INC+DEC.
2. Press the FUN key to access the function selection menu.
3. Select function F7 by pressing keys INC and DEC.
4. Confirm by pressing the VAL key. Request of the first location to be deleted
(that is, the default value 0001) will now appear. Only the first decimal point to the left will appear indicating that the initial location is being
selected.
5. Select location by pressing keys INC and DEC, and confirm by pressing the VAL key.
6. Request of final location to be deleted will now appear. The value shown is the one which has been previously selected as the initial location so
that only a value greater than this can be selected by pressing keys INC and DEC. The last decimal point to the right will now appear indicating
that the final location is being selected.
7. After having selected the final location, confirm by pressing the VAL key; the letter -C- will now appear on the left-hand side of the display.
8. Press the VAL key again to confirm. The M2000PE will now automatically delete all the codes stored in the set of programmed locations.
Upon deletion being completed, system will return to the function selection menu.
Deleting all codes
Deletion of all codes avoids having to scroll all locations and having to delete one code at a time in case of memory having to be fully cleared.
1. Access programming mode by pressing keys INC+DEC.
2. Press the FUN key to access the function selection menu.
3. Select function F8 by pressing keys INC and DEC.
4. Confirm by pressing the VAL key. The letter C will appear on the left side of the display.
5. Confirm again by pressing the VAL key. The M2000PE will fully delete the code area only. All other stored parameters (relay times, channels,
etc.) will remain unaltered.
Upon deletion being completed, system will return to the function selection menu.
Serial transferring of data
1. Access programming mode by pressing keys INC+DEC.
2. Press the FUN key to access the function selection menu.
3. Select function F9 by pressing keys INC and DEC.
4. Confirm by pressing the VAL key. Request of the first location to be transferred (that is, the default value 0001) will now appear. Only the first
decimal point to the left will appear indicating that the initial location is being selected.
5. Select location by pressing keys INC and DEC, and confirm by pressing the VAL key.
6. Request of final location will now appear. The value shown is the one which has been previously selected as the initial location so that only a
value greater than this can be selected by pressing keys INC and DEC. The last decimal point to the right will now appear indicating that the
final location is being selected.
7. After having selected the final location, press the VAL key to confirm; the four lower segments in the display will now come on.
8. Press the VAL key again to confirm; this will initiate data transfer which while in progress will be signalled by the four segments in the lower part
of the display flashing.
Pressing of the FUN key at any time causes system to exit from data transfer mode and to return to the function selection menu.
If the FUN key is pressed while data is being transferred, the system in any case completes transfer of the code being processed, after which it exits
from this mode and returns to the function selection menu.
Location Code
120 ⇒112233
121 ⇒112234
122 ⇒112235
123 ⇒112236
124 ⇒112237
125 ⇒112238
126 ⇒112239
127 ⇒112240

M2000PE ENGLISH ISM2000PEEU_02_05.doc
7
Selecting the modalities for using the memory
It is possible to select three different modalities for using the code memory:
F: The codes entered via radio can activate either of the two relays, according to the assignment made with functions F3 and F4.
H: The memory is divided into two parts: lower part from location 1 to location 1000 (associated to PORT 1), upper part from location 1001 to location
2000 (associated to PORT 2).
This function is useful to manage two groups of different users in the same unit, to discriminate the activation of relay 1 or relay 2 with the same user
code (badge, radio, tag).
P: The anti-passback function is active: each code, once one of the two relays is activated (input), cannot be reactivated unless the other one is
activated first (output).
In order to select the modality:
1. Press keys INC and DEC at the same time
2. Press key FUN to access the select functions menu
3. Using keys INC and DEC select function F10
4. Confirm the selection with VAL: the display shows the current value of the modality
5. Using keys INC and DEC select modality F, H or P.
6. Confirm with key VAL: the display returns to selecting functions and the new modality is active
7. Press keys INC and DEC at the same time to exit programming
WARNING: By modifying the modalities for using the memory all previously stored codes are deleted.
In order to assign a remote control to relay 1 in modality H, store it by pressing channel 1 or channel 3. To assign it to relay 2, store it by pressing
channel 2 or channel 4.
Selecting the communication protocol
The control unit can dialog via the serial port by using two different communication protocols:
0: Communication with GTSYSTEM, M2000 or MKEYB.
1: Communication with printer PRINT2000
In order to select the protocol:
1. Press keys INC and DEC at the same time
2. Press key FUN to access the select functions menu
3. Using keys INC and DEC select function F11
4. Confirm the selection with VAL: the display shows the current value of the protocol
5. Using keys INC and DEC select protocol 0 or 1
6. Confirm with key VAL: the display returns to selecting functions and the new protocol is active
7. Press keys INC and DEC at the same time to exit programming
Printing the list of codes
In order to print the list of all the codes in the memory:
1. Set protocol 1 via function F11 (see Selecting the communication protocol)
2. Connect the printer PRINT2000 to the serial port
3. Select function F12
4. Press key VAL
When the printing is finished the control unit returns to the select functions menu.
Printing the events
If protocol 1 has been selected via function F11 (see Selecting the communication protocol), and the printer PRINT2000 is connected to the serial
port, each time a code is received a string will be printed containing the location, user status, user code, date, time and door, in the following format:
LOCATION STATUS USER CODE
DATE TIME DOOR
Type of event Print example
Valid Code POS.0001 VALID 00524602
01/12/00 04:59 DOOR1
Code not stored POS.0000 INVALID 00524999
Anti-passback (with modality P for using the memory) POS.0001 APB 00524602
03/12/00 11:04 DOOR1
The printer PRINT200 must have been previously programmed with the correct date and time.
Operating the system via the remote keyboard
The M2000PE may be connected to a terminal equipped with 4 keys and 4 displays for the remote programming, entering and deleting of codes.
Communication is made via an RS485 serial line.
Maximum link-up distance between the M2000PE and the M/KEYB keyboard/display is 500 metres.
The keys and displays of the remote terminal are exactly the same as those on the base unit both in terms of configuration and functions.
The M2000PE automatically detects the presence of the remote terminal, so that the same can be immediately controlled from the remote keyboard.
Programming cannot be made simultaneously on the central unit and the remote keyboard. In case of programming having been initiated from the
remote keyboard, the displays of the central unit will stay off and vice versa. This means that a programming operation initiated from the central unit
cannot be aborted from the remote keyboard and vice versa.
The terminal permits all M2000PE programming operations except the serial transfer of data from one central unit to another.
Note: Connect the central units as shown in the figure (maximum connection distance is 500 meters).

M2000PE ENGLISH ISM2000PEEU_02_05.doc
8
Diagram of terminal strips and keys:
M/2000E
18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1
19 20 21 22 23 24
M/2000E
18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1
19 20 21 22 23 24
Port 1 : enabling relay contact
FUN DEC INC VAL
YELLOW BLUE RED GREEN FUN DEC INC VAL
YELLOW BLUE RED GREEN
Port 2 : enabling relay contact Port 1 : enabling relay contact Port 2 : enabling relay contact
In case of the RS485 being used to connect MKEYB or GTSYSTEM, it is necessary that other M2000PEs which may have been connected
through terminals 21 and 22 be disconnected.
TERMINAL STRIP
1 Port 2: relay contact N.C. 13 Port 1: enabling contact relay
2 Port 2: relay common 14 Port 1: relay activation key
3 Port 2: relay contact N.O. 15 GROUND
4 Port 2: enabling contact relay 16 Port 1: data input (DATA1)
5 Port 2: relay activation key 17 Port 1: data input (DATA0)
6 GROUND 18 Port 1: output for reader power supply (9Vdc)
7 Port 2: data input (DATA1) 19 Antenna
8 Port 2: data input (DATA0) 20 Antenna braid
9 Port 2: output for reader power supply (9Vdc) 21 Serial line (RS485)
10 Port 1: relay contact N.C. 22 Serial line (RS485)
11 Port 1: relay common 23 Power supply, + 12-24Vac/dc
12 Port 1: relay contact N.O. 24 Power supply, - 12-24Vac/dc
Note: Make sure that terminals 4 and 13 are connected to terminals 6 and 15, respectively (see figure) in order to enable the corresponding relay
outputs 1 & 2. This contact is particularly useful for enabling, for instance, the relay outputs of the M2000PE via external devices such as buried
magnetic coils (opening command given by the M2000PE only in case of a vehicle being present on the coil so as to avoid undesired opening caused
by accidental radio transmission) or via timed relays (M2000PE enabled within a given time interval), as well as for closing the normally open contact
of a switch, and so on.
Note: The input to force the activation of the single door (respectively the clamp 5 and 14) it is active if referred to GND.
DECLARATION OF CONFORMITY
Hereby, PRASTEL S.p.A., declares that M2000PE is in compliance with the essential requirements and other relevant provisions of Directive
1999/5/EC.
M/2000PE
F1 : Relay 1 setup
F2 : Relay 2 setup
F3 : Radio channel →Relay 1
F4 : Radio channel →Relay 2
F5 : Password
F6 : Block program
F7 : Block erase
F8 : Erase all
F9 : Data copy
F10 : Memory mode
F11 : Serial port mode
F12 : Print
M/2000PE F1 : Relay 1 setup
F2 : Relay 2 setup
F3 : Radio channel →Relay 1
F4 : Radio channel →Relay 2
F5 : Password
F6 : Block program
F7 : Block erase
F8 : Erase all
F9 : Data copy
F10 : Memory mode
F11 : Serial port mode
F12 : Print
Other manuals for M2000PE
2
Other PRASTEL IP Access Controllers manuals
Popular IP Access Controllers manuals by other brands

Security Brands
Security Brands ASCENT M3 install guide

ZKTeco
ZKTeco P160 quick start guide

Access Security Products
Access Security Products KP-401 user manual

Sebury
Sebury BC2019 instruction manual

Assa Abloy
Assa Abloy HID Signo Biometric Reader 25B user guide

Safran
Safran MorphoAccess J Series installation guide