Kemppi PFU 210e User manual

Operating
manual
Operating manual – Brugsanvisning – Gebrauchsanweisung – Manual
de instrucciones – Käyttöohje – Manuel d’utilisation – Manuale d’uso –
Gebruiksaanwijzing – Bruksanvisning – Instrukcja obsługi – Manual de
utilização – Инструкции по эксплуатации – Bruksanvisning – 操作手册
PFU 210e
1920690
1908

© Kemppi Oy 2019
4
2
3
9
7
8
6
A
1
2
5
B
4
3
C
2
1
3
5
4
3
5
4
3
22
11
4
3
2
1
4
3
2
1
3
6
6
7
1
5

3PFU 210e
specication of the product described at any time without
prior notice. Do not copy, record, reproduce or transmit
the contents of this guide without prior permission from
Kemppi.
Convention Used For
Note Gives the user a piece of information of particular importance.
Caution Describes a situation that may result in damage to the equipment or system.
Warning Describes a potentially dangerous situation that may result in personal damage or
fatal injury.
1.3 Disclaimer
While every eort has been made to ensure that the
information contained in this guide is accurate and
complete, no liability can be accepted for any errors
or omissions. Kemppi reserves the right to change the
The powered lter unit PFU 210e lters ambient air and
blows the ltered air to the hood of a welding helmet.
The airow creates positive pressure inside the headpiece,
which prevents the external contaminated air from
entering the user’s breathing zone while supplying the
user with clean breathing air. PFU 210e is compatible with
Gamma GTH3 and Beta FA welding helmets.
2. Safety
Read the following precautions carefully before using the
product.
PFU 210e provides protection against non-toxic hazardous
particles and solid and liquid aerosols in breathing air in
welding and similar processes.
Warning:
• It is strictly forbidden to use any other than Kemppi
branded lters or other parts or accessories with
Kemppi’s personal protection equipment. If you do
not respect this safety regulation, serious damage for
your health may occur.
Warning:
• Do not use this product against toxic gases and
vapours.
• Oxygen concentration in the surrounding area must
not drop under 17%.
• Type and concentration of the contaminants in the
working place must be known to the user.
• Do not use PFU 210e in unventilated areas such as
tanks, pipes and channels.
• Do no use PFU 210e in areas where there is danger
of explosion.
• Use PFU 210e only with the blower unit switched on.
If PFU 210e is switched o, the respiratory system
gives little or no respiratory protection. There is also
a risk of high concentration of carbon dioxide (CO₂)
1.2 About this manual
Read this manual carefully before using the equipment
for the rst time. Pay particular attention to the safety
instructions.
and a low level of oxygen inside the headpiece.
• Before each use, check the air ow. For instructions,
see chapter Air ow test.
• If PFU 210e stops working for any reason, leave the
contaminated area immediately.
• To provide sucient protection, the headpiece
must t the user´s face perfectly. If the seal of
the headpiece is not tted properly, for example,
due to a beard or long hair breaking the seal, the
protective eect of the complete system is reduced.
• Make sure that the air hose does not make a loop or
get caught or trapped in the surrounding objects.
• Use the correct type of lter according to the type
of contamination.
See chapter Filters.
• If the breathing air in the workplace contains both
particle and gas contamination, use an adequate
combined lter.
• When you are using gas lters to protect you
against gases that are dicult to identify by smell
or other senses, follow all special rules for the
current conditions.
• Immediately replace the lter(s) as soon as you can
smell the contaminant.
• Use only original lters certied for the particular
respiratory unit.
1. Introduction
1.1 About PFU 210e
ENGLISH

4© Kemppi Oy 2019
3. Parts 1
Check that the package is complete and that no part has
been damaged.
1. Air hose, comes with a cover
2. Air hose connector
3. ON/OFF button
4. Shoulder harness holder
5. Filter cover
6. Filter cover opening button
7. Battery
8. Battery opening button
9. Leather belt
• Ensure that the air hose is not exposed to sparks,
even if an air hose protection cover is used.
• During a period of really hard work, when the user’s
breathing becomes very intense, pressure inside the
hood may decrease and decrease the protective
eect.
Note: If the recommendations stated in this
manual are ignored, the warranty is automatically
invalidated and the level of personal protection
may not meet the designated standards.
ABattery status: see chapter "5 Battery".
BFilter status: when the red light switches
on, the lter must be changed.
CBlower status: maximum and minimum
power.
4. Operation
4.1 Assembling PFU 210e
1. Fit the lters and the lter cover properly to the
blower unit body.
2. Insert the battery to the blower unit body.
3. Connect the air hose to the blower unit body.
4. Fasten the belt around your waist. A shoulder harness
is available as an accessory.
5. Connect the air hose to the welding helmet.
4.2 Operating PFU 210e
Before each use:
• Check all the parts. Replace damaged or worn parts.
• Perform an air ow test to ensure that the air ow
is sucient.
• Check that the air hose is properly connected at both
ends.
• Check that the air ows all the way from the blower
to the helmet.
Using the device:
• To turn the blower unit on or o, press and hold the
ON/OFF button.
• When turning the blower unit o, press the button
until the device beeps several times and then
switches o.
• To adjust the blower speed, shortly press the ON/OFF
button.
4.3 Air ow test 2
Perform the air ow test before every use.
1. Connect a ow meter to the blower unit. Make sure
it is properly connected and upright.
2. Switch on the blower unit.
3. Check that the ball rises up to the green area.
4. To check the functionality of the alarm mechanism,
cover the ow meter with your hand and wait for
the alarm to go o.
ENGLISH

5PFU 210e
5. Battery 3
The battery status light shows how much charge is left:
• 4 green bars: 80-100 % left
• 3 green bars: 60 - 80 % left
• 2 green bars: 40 - 60 % left
• 1 green bar: 20- 40 % left
• 1 red bar: < 20 % left
• Red bar ashes, the unit vibrates and beeps twice:
critically low
5.1 Changing the battery
1. To remove the battery, press the opening button, and
pull the battery outwards.
2. To insert the battery, press the battery against the
bottom of the blower unit, and slide the battery
inwards.
5.2 Charging the battery
The batteries are pre-charged (approx. 50%).
Caution: Only charge the battery in temperatures
above 0 °C.
Warning: Only use the Kemppi Charger for
charging the battery.
A wrong charger may cause a re or an explosion.
1. Remove the battery from the blower unit.
2. Connect the Kemppi Charger to a power supply
and to the battery. Charging time (80%): ca.
1.5 h/ SD battery, 2.5 h / HD battery.
6. Filters
1. Filter cover
2. Spark arrester
3. Prelter
4. Particle lter
5. Odor lter (optional)
6. Gas lter
4For protection against particles, always use a particle
lter.
5For protection against gases, always use a gas lter
combined with a particle lter. Do not use the odor lter if
a gas lter is present.
The lter service life depends on the working environment.
If the environment is very dirty, Kemppi recommends
changing the lter after every work shift. Immediately
replace the lter, if you are using the gas lter and you can
smell the contaminant, or if the lter status icon ashes red.
To warn about a clogged lter, the blower unit also beeps
and vibrates at a regular interval.
Caution: Always replace a clogged lter. Never
attempt to clean the lter, for example, with
pressurized air.
6.1 Changing the lter 6
1. To remove the cover, press the opening button.
2. Check which filters need replacing. Sometimes
replacing the prelter is enough.
3. Before inserting the lter, check that the lter and the
lter gasket are undamaged.
4. Insert the lter tightly to the lter cover.
5. To attach the lter cover to the blower unit, rst push
the hinged side in its place.
7. Daily maintenance 7
Kemppi recommends cleaning PFU 210e after every use.
1. Clean the outer surface of the blower unit with
lukewarm water, mild soap and a soft cloth. Let the
unit dry completely before reassembling.
Note:
• Ensure that no water or detergents get into the
blower unit / lter.
• Always clean the device in a ventilated room or
outside. Be aware of harmful dust settled on any
parts of the unit.
• Never use ammable cleaning liquids or abrasive
cleaners.
2. You can detach and wash the air hose cover.
Note: The re retardant on the air hose cover may
wear out after several washes. Wash max. 5 times.
8. Storage
Store PFU 210e in an environment with temperature
between -20 °C and +50 °C and humidity <80% Rh. The
product has a two-year storage life if stored in its unopened
original package. For longer storage periods, keep the
charging level of the battery at about 50 %. Check the
charging level every 6 months and charge, if necessary.
Filters: see the expiry date on the package. Store the lters
in the manufacturer-sealed packages.
ENGLISH

6© Kemppi Oy 2019
9. Technical data
Model PFU 210e
Manufacturer Kemppi Oy, PL 13, 15801 Lahti, Finland
Compliance with standards PFU 210e: EN 12941
• With Gamma GTH3: TH3 class
• With Beta FA: TH2 class
PFU 210e: AS/NZS 1716
• With Gamma GTH3: P2 class
• With Beta FA: P1 class
Particle lters: P R SL
Gas lters: A1B1E1
Type inspected by: FORCE Certication A/S
(Notied Body 0200)
Airow Min. 160 l/min
Max. 210 l/min (high ow, particle lter)
Belt size max.125 cm
Weight (blower unit, particle lter, battery, hose
and belt)
2510 g
Operating temperature -5...+55 °C
Recommended humidity range for use < 80 % Rh
Battery type SD: Li-ion 14.4 V, 3.2 Ah (46 Wh)
HD: Li-ion 14.4 V, 6.4 Ah (92 Wh)
Battery charging time 1.5 h (SD) / 2.5 h (HD) (80%)
Battery lifetime 500 charging cycles
Expected battery operation time
Blower speed Battery operation time (hours)
Normal ow level SD = 7 h with particle and odor lter
HD = 9 h with gas and particle lter
High ow level SD = 5 h with particle and odor lter
HD = 10 h with particle lter
• The expected operation time is with a clean lter. If the lter is clogged the battery lifetime is considerably shorter.
• The battery operation time depends on the type of work and environment.
• Using the work lights reduces the battery lifetime by approximately 10-20% (Gamma GTH3 XFA).
ENGLISH

7PFU 210e
10. Ordering codes
Part Ordering code
Blower unit pack (incl. body of blower unit, lter
cover, belt) SP011996
Body of blower unit SP012217
Air hose SP012253
Air hose with cable (XFA) SP012148
Hose protection cover SP010788
PFU 210e Battery HD SP012021
PFU 210e Battery SD SP012584
PFU 210e Battery charger SP012426
Belt SP010243
Harness SP011894
Flow meter SP012492
Filter cover SP012095
Spark arrester 10 pcs SP9320003
Prelter SP9320002 10 pcs / SP9320002MP 100 pcs
Particle lter Life+ SP010415 1 pc / SP010415MP 20 pcs
Gas lter Life+ SP009934
Odor lter 5 pcs SP012223
11. Disposal of the unit
Note: Do not dispose of any electrical equipment with normal waste!
At the end of the useful working life of the unit and its accessories, make sure that you follow national and local regulations
regarding the disposal of the unit. The unit includes some parts that include or are made of non-environmentally friendly
or hazardous materials.
In observance of WEEE Directive 2012/19/EU on waste of electrical and electronic equipment and European Directive
2011/65/EU on the restriction of the use of certain hazardous substances in electrical and electronic equipment, and
their implementation in accordance with national law, electrical equipment that has reached the end of its life must
be collected separately and taken to an appropriate environmentally responsible recycling facility. The owner of the
equipment is obliged to deliver a decommissioned unit to a regional collection centre, as per the instructions of local
authorities or a Kemppi representative. By applying these European Directives you improve the environment and human
health.
ENGLISH

Declarations of Conformity – Overensstemmelseserklæringer –Konformitäts-erklärungen –
Declaraciones de conformidad – Vaatimustenmukaisuusvakuutuksia – Déclarations de conformité –
Dichiarazioni di conformità – Verklaringen van overeenstemming – Samsvarserklæringer –
Deklaracje zgodności – Declarações de conformidade – Заявления о соответствии – Försäkran om
överensstämmelse – 符合性声明
userdoc.kemppi.com
Other manuals for PFU 210e
2
Table of contents
Other Kemppi Water Filtration System manuals
Popular Water Filtration System manuals by other brands

Oase
Oase BioSmart 36000 operating instructions

MS Schippers
MS Schippers MS Reverse Osmosis 30 manual

Motor Guard
Motor Guard MHT-7000 instructions

Sea Clear Watermakers
Sea Clear Watermakers G-20 installation manual

Crystal Quest
Crystal Quest CQE-RC-00808 Installation and operation guide

GE
GE PNRQ15RBL Owner's Manual & Installation Instructions