Safety Precautions
&WARNING .I
Improper installation, adjustment, alteration, service or I
maintenancecancauseDEATH, SERIOUS BODILY INJU.RY,I
OR PROPERTY DAMAGE. Refer to this manual for assm-I
.t_ce or.consultyourlocalSearsServiceCenter for furtherI
mforma_on. I
_,WARNING
At thetime ofmanufacturethiswaterheaterwasprovidedwith
a combinationtemperatu.re-pressuresrelief valvecertifiedbya
nationallyrecognizedtesting laboratorythat maintainsperiodic
inspectionof productionof listedequipmentor materials,as
meatingthe requirementsfor ReliefValvesandAutomaticGas
ShutoffDevicesfor Hot Water SupplySystems,andthe latest
edition of ANSI Z21,22andthe cederequirements of ASME.If
replaced,the valvemust meet the requirementsoflocalcedes,
but notlessthana combinationtemperature and pressurerelief
valvecertifiedasmeetingtile requirementsfor ReliefValvesand
AutomaticGasShutoffDevicesfor Hot Water SupplySystems,
ANSI Z21.22bya nationallyrecognizedtesting laboratorythat
maintainsperiedicinspectionof productionof listedequipment
ormaterials.
The valvemustbe markedwith a maximum set pressurenot
to exceedthe marked hydrostaticwort_ng pressureof the
water heater (150 Ibsdsq.in.) and a dischargecapacitynot
lessthan the water heater inputrate asshownon the model
rating plate.(Electricheaters- watts dividedby 1000x 3415
equaJBTU/Hr, rate.)
Yourlocaljurisdictionalauthority,whilemandatingtheuseof a
temperatumt)ressure relief valvecomplyingwith ANSI Z21,22
andASME,mayrequirea valvemodeldifferentfromtheonefur-
nishedwiththewater heater.
Compliancewith suchlocalrequirements mustbesatisfiedby
the installeror end userofthe water heaterwith a locallypre-
scribedtemperature-pressurerelief valveinstalledinthe desig-
natedopeningin the water heater in placeof the factoryfur-
nishedvalve.
Forsafeoperationof the water heater,the relief valvemustnot
beremovedfromit'sdesignatedopeningor plugged.
The temperature-pressurerelief valvemustbe installeddi_'tly
intotheErringofthewaterheaterdesignatedfor thereliefvalve.
Positionthevalvedownwardandprovidetubingsothat anydis-
chargewillexit onlywithin 6 inchesabove,or at anydistance
belowthe structuralfloor,Be certainthat no contactismade
withanyliveelectricalpart.The dischargeopeningmustnot be
blockedor reducedin sizeunderany circumstance_Excessive
length,over30 feet,or useofmore than fourelbowscancause
restrictionandreducethe dischargecapacityofthevalve.
No valveor otherobstro_on isto be placedbetweenthe relief
valveandthe tank. Do not connecttubing directlyto discharge
drainunlessa 6"air gapisprovided.Topreventbodilyinjury,haz-
ardto life,or pmpertydamage,the reliefvalvemustbeallowed
to dischargewaterin quantitiesshouldcircumstancesdemand.
If the dischargepipe is not connectedto a drain or other
suitable means, the water flow may cause property
damage.
The DischargePipe:
Mustnot be smallerin sizethan the outtet pipesizeofthe
valve,or haveanyreducingcouplingsor otherrestriction_
Mustnot be pluggedor Mucked.
Must be ofmateriallistedfor hot water distribution.
Must be installedsoasto allowcompletedrainageof both
the temperature-pressurereliefvalve, and the discharge
pipe.
Mustterminate at an adequatedrain.
Mustnot haveanyvalvebetween the relief valveand tank.
AWARNING
HAZARD OF ELECTRICAL SHOCKI Before removing I
any access panels or servicing the water heater, make I
sure the electrical supply to the water heater m turned
"OFF". Failure to do this could result in DEATH, SERI-
OUS BODILY INJUR_,OR PROPERTY DAMAGE.
AWARNING
HOTTER WATER CAN SCALD: Water heaters are
intended to produce hot water. Water heated to a tem-
perature whichwill satisfyspace.heating,clotheswashing,
dish washing, and other sanitizing needs can scald and
permanently injure you upon contact. Some people are
more likelyto be permanently injured by hot water than
others. These includethe elderly,children, the infirm, or
physically/mentally handicapped. If anyone using hot
water in your home fits into one of these groups or if
there isa local code or state law requiring a certain tem-
perature water at the hot water tap, then you must take
specialprecautions.In addition to usingthe lowest possi-
ble temperature setting that satisfies your hot water
needs,ameans such as amixing valve, shallbe used at
the hot water taps usedby these people or at the water
heater. Mixing valvesare availableat plumbingsupplyor
hardware stores. Follow manufacturers instructions for
installation of the valves. Before chang!ng the factory
setting on the thermostat, read the Temperature
Regulation"sectioninthis manual.
AWARNING
WATER HEATERS EQUIPPED FOR ONE VOLTAGE
ONLY: This water heater isequippedfor one type voltage
only.Check the rating plate near the bottom accesspanel
for the correct voltage. DO NOT usethis water heater
with any voltageother than the one shownon the model
rating plate. Failure to usethe correct voltagecan cause
problemswhich can result in DEATH, SERIOUS BODILY
INJURY,OR PROPERTY DAMAGE. If you haveany ques-
tions or doubtsconsultyour el_ric company.
AWARNING i
INSULATING !ACKETS: Whep installing an 1external
water heater insulation jacke_ o_ an electric water
heater: ! '
a. DO NOT cover the temperaturn-pressur_ relief Valve.
b. DO NOT put insulationover _he accesscoversor any
t'i
access areas.
€. DO NOT cover or remove operatingiinst_'uctions, and
safety related warning labels_and:_materials affixed to
the water heater,
I _,WARNING
Do not usethis appl_ of it hasbeen under
water. An electrical short or malfunction couldoccur.The
water heater shouldbe replaced.
2
ACAUTION
WATER HEATERS EVENTUALLY LEAK: Installation of
the water heater must be accomplished in suchamanner
that ifthe tank or any connections shouldleak, the flow of
water will not cause damage to the structure. When such
locationscannot be avoided, a suitable drain pan should
be installedunder the water heater. Drain pans are avail-
able at your local SearsStore. Such a drain pan must be
piped to an adequate drain. Under no circumstances is
the manufacturer or Searsto be held liablefor anywater
damage in connection with thiswater heater,