Ketra N3-REC User manual

N3
SATELLITE
Instlltion Guide
Models
N3-REC Recessed Rated Housing
N3-PLE Plenum Rated Housing

Risk of electric shock. Use in dry locations only.
Turn power OFF at circuit breker or remove fuse. Dmge to this product cused by wiring with power
on voids the wrrnty.
Due to the risk of electric shock, a licensed electricin should instll this power supply unit in strict
complince with the Ntional Electricl Code nd ny stte or locl code which my pply.
This device complies with Part 15 of the FCC Rules. Operation is subject to the
following two conditions: ( 1 ) this device may not cause harmful interference, and ( 2 ) this device must
accept any interference received, including interference that may cause undesired operation.
Must be mounted at least 6 ft (1.8 m) away from wireless interference sources like microwaves, Wireless
Access Points (WAPs) etc.
Note: This equipment has been tested and found to comply with the limits for a Class B digital device,
pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against
harmful interference in a residential installation. This equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in accordance with the instructions, may cause harmful
interference to radio communications. However, there is no guarantee that interference will not occur
in a particular installation. If this equipment does cause harmful interference to radio or television
reception, which can be determined by turning the equipment o and on, the user is encouraged to
try to correct the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit dierent from that to which the receiver
is connected.
• Consult the dealer or an experienced radio/TV technician for help.
This device contains licence-exempt transmitter(s)/receiver(s) that comply with Innovation, Science and
Economic Development Canada’s licence-exempt RSS(s). Operation is subject to the following
two conditions:
• This device may not cause interference.
• This device must accept any interference, including interference that may cause undesired
operation of the device.
!WARNING
2|N3 INSTALLATION GUIDE
P/N 3662351 Rev B
© 2019 Ketra, Inc. All rights reserved.

Contents
Product Overview 4
Pre-Installation 5
Pre-Installation Instructions 6
Installation 7
Before Physical Mounting 7
Physical Mounting 8
Installation 9
Overview of Third-Party Controls (KetraNet systems only) 11
Warranty Tech Support 12
3|N3 INSTALLATION GUIDE
P/N 3662351 Rev B
© 2019 Ketra, Inc. All rights reserved.

Product Overview
Ketra’s N3 satellite provides several vital system functions: control of luminaires,
integration of third party control and lighting products, and on-board memory and
astronomical time clock functionality. The N3’s wireless connectivity enables its
installation in multiple, convenient locations.
fig. 1
AC Power In
USB
Firmware Updates
DMX Out
(stand-alone only)
Status Indicators
Multifunction I/O
(KetraNet only)
010 V In/Out
Contact Closure In/Out
024 V Input
AC Power/Signal Out
Connect to Ketra luminaires
4|N3 INSTALLATION GUIDE
P/N 3662351 Rev B
© 2019 Ketra, Inc. All rights reserved.

Pre-Installation
Turn OFF electrical power to all circuit breakers feeding into the panel before installing
or servicing this product.
Improper use or installation can cause SERIOUS INJURY, DEATH, OR LOSS/DAMAGE
OF PROPERTY.
This device should be protected by a 20 A circuit breaker.
This device includes a two-way radio. For optimal performance and signal integrity:
• Do not install in third-party metal enclosures
• Use non-metal enclosures (e.g. plastic, fiberglass or PVC)
Product is plenum-rated for non-air-handling spaces.
Product is direct-insulation contact rated.
If placed in enclosure alongside other electrical components, take necessary precautions regarding
operating temperatures.
Product is UL surface-mount listed. Does not require a dedicated enclosure.
This product contains both class 1 and class 2 electrical connections. The sections are physically
separated by a barrier. MAINTAIN PHYSICAL SEPARATION BOTH INSIDE AND OUTSIDE OF DEVICE IN
ACCORDANCE WITH ELECTRICAL CODES.
This device must be installed by a licensed electrician in accordance with all national and local codes.
5|N3 INSTALLATION GUIDE
P/N 3662351 Rev B
© 2019 Ketra, Inc. All rights reserved.

PREINSTALLATION
Pre-Installation Instructions
This product has numerous capabilities and functions. Not all uses will apply to each specific application.
WIRELESS NETWORK
• Product needs to be within range of Ketra’s controls. For more information, please refer to the
installation guides for our controls products.
• Avoid metal obstructions.
• Walls may impact communication depending upon construction method and materials.
• Must be mounted at least 6 ft (1.8 m) away from wireless interference sources like microwaves,
Wireless Access Points (WAPs) etc.
CONTROL CONNECTIONS
Distance limitations for each control topology should be taken into consideration.
• DMX: 1800 ft (548 m) maximum.
• 010: 50 ft (15.2 m) maximum total, depending on wire gauge.
• Contact Closure: 50 ft (15.2 m) maximum total, depending on wire gauge.
• 24 Volt: 50 ft (15.2 m) maximum total, depending on wire gauge.
6|N3 INSTALLATION GUIDE
P/N 3662351 Rev B
© 2019 Ketra, Inc. All rights reserved.

Installation
* Contact Ketra for thicker ceiling types.
Before Physical Mounting
Note the serial number and product location; this information will be useful later in the installation.
(The serial number can be found on the top of the control board cover - see fig. 2.)
Product is UL damp location listed (can be used in outdoor locations provided it is protected from direct
water exposure).
Choose a suitable mounting surface and four fasteners that will fit the 0.2 in (5 mm) mounting holes
(e.g. #8 countersunk head, #9 countersunk head).
This product has a suggested clearance to ensure access to all connections and all analog user interface
switches (see fig. 3).
fig. 2
fig. 3
AC Mains INTRIAC Control
LN LN
Power & Signal OUT
SNL
Activity
Status Monitor
B
A DMX DALIT RIAC Power
AB
DC Out DALIDMX Out DMX In
Analog I/O
+
–
+4
3
2
1
+
+
+
COM
COM
COM
COM
D+
–
+
D+
D–
GND
GND
D–
SN: KD00000016
DC: K3914
OC: N3INDREC1BK
AC Mains INTRIAC Control
LN L
N
Power & Signal OUT
SNL
Activity
Status Monitor
B A DMX DALIT RIAC Power
AB
DC Out DALIDMX OutDM X In
Analog I/O
+
–
+4
3
2
1
+
+
+
COM
COM
COM
COM
D+
–
+
D+
D–
GND
GND
D–
Serial Number
8 in (203.2 mm)
0.25 in (6.34 mm)
6 in (152.4 mm)
7|N3 INSTALLATION GUIDE
P/N 3662351 Rev B
© 2019 Ketra, Inc. All rights reserved.

INSTALLATIONINSTALLATION
fig. 4
fig. 5
fig. 6
Physical Mounting
1. Remove the lid. Note that screws are captive and need not be fully removed from lid (see fig. 4).
2. Remove plastic plugs from knock-outs as required (see fig. 5).
3. Mount box to surface with appropriate fasteners. Note: inner diameter of hole is ⁄ in (4.76 mm)
(see fig. 6).
Screws
Main Cover Conduit Plugs
Mounting Holes
⁄ in (4.76 mm) hole
8|N3 INSTALLATION GUIDE
P/N 3662351 Rev B
© 2019 Ketra, Inc. All rights reserved.

INSTALLATION
Installation
DO NOT CONNECT AC SUPPLY TO TERMINALS MARKED “TRIAC CONTROL.”
Triac Control feature is not supported.
STEP 1
Connect AC supply
Use conduit or NM type cable as appropriate.
Note: Acceptable wire is both solid core and stranded. Gauge range is 2.59 Ø[mm]/5.26 Ø[mm] -
1.29 Ø[mm]/1.31 Ø[mm].
1. Open appropriate terminals by flipping orange levers into UP position (see fig. 7). Make connections to
the “AC Mains In” section connecting to appropriate line, neutral and ground terminals.
Note: Wire strip length is 0.47 in (12 mm).
2. Insert appropriate conductors from Mains Power (see fig. 8).
Black conductor goes to “L” terminal (Black).
White conductor goes to “N” terminal (White).
Green conductor goes to “ ” terminal (Green).
Note: Conductor colors are not always as listed. These colors vary depending on your wiring setup.
To ensure the correct wiring, consult a professional electrician.
fig. 7 fig. 8
continued on next page
9|N3 INSTALLATION GUIDE
P/N 3662351 Rev B
© 2019 Ketra, Inc. All rights reserved.

INSTALLATION
fig. 9 fig. 10
STEP 2
Connect power and signal output to linear luminaires.
Note: Details on G2 linear connections available in G2 Installation Guide.
1. Open appropriate terminals by flipping orange levers into UP position (see fig. 10).
2. Make connections to the “Power and Signal OUT” section connecting to appropriate line, neutral and
ground terminals.
Note: Details on connections with the linear product family available in their respective installation guides.
3. Insert appropriate conductors from leader cable (see fig. 9):
Black conductor goes to “L” terminal (Black).
White conductor goes to “N” terminal (White).
Green conductor goes to “ ” terminal (Green).
Red/Purple conductor goes to the “S” terminal (Purple).
continued on next page
10|N3 INSTALLATION GUIDE
P/N 3662351 Rev B
© 2019 Ketra, Inc. All rights reserved.

INSTALLATIONINSTALLATION
Overview of Third-Party Controls (KetraNet systems only)
The class 2 control input/output compartment enables interface with numerous devices. Choose the
appropriate terminals based upon your application.
Sections include:
Analog I/O
This section contains four ports. Each port can be configured independently to be any of the following
control types. Refer to applicable protocol wiring diagrams.
• Contact closure input
• Contact closure output
• 010 V input
• 010 V output
• 024 V input
DMX
“DMX Out” can be configured to operate as a stand-alone DMX universe of control. Refer to applicable
protocol wiring diagrams.
CONNECT THIRDPARTY CONTROLS
1. Use conduit or NM type cable as appropriate.
Note: Acceptable wire is both solid core and stranded. Gauge range is 1.29 Ø[mm]/1.31 Ø[mm] -
0.511 Ø[mm]/0.205 Ø[mm]).
2. Open appropriate terminals by depressing appropriate terminal buttons.
3. Make connections to the appropriate ports.
Note: Wire strip length is 0.350.39 in (910 mm).
Refer to applicable protocol wiring diagrams.
VERIFY SUCCESSFUL INSTALLATION
1. Apply power to circuit.
2. Green “Power” LED will illuminate indicating successful installation and product functionality.
3. Optional: If data is present at any control port, appropriate LED will indicate status.
4. Disconnect power and install cover.
5. Restore power and configure device using Ketra Design Studio Software.
6. For software download and updates, visit www.ketra.com.
11|N3 INSTALLATION GUIDE
P/N 3662351 Rev B
© 2019 Ketra, Inc. All rights reserved.

Warranty Tech Support
Limited warranty terms can be found at:
www.ketra.com/warranty
For questions and technical support please contact:
(844) 5886445
ketrasupport@lutron.com
Ketra and KetraNet are trademarks or registered trademarks of Lutron Ketra LLC, in the US and/or
other countries.
12|N3 INSTALLATION GUIDE
P/N 3662351 Rev B
© 2019 Ketra, Inc. All rights reserved.

Notes
13|N3 INSTALLATION GUIDE
P/N 3662351 Rev B
© 2019 Ketra, Inc. All rights reserved.

6231 E. Stssney Ln.
Bldg. 13, Suite 400
Austin, TX 78744
www.ketra.com
512.872.4349
P/N 3662351 Rev B

N3
SATELLITE
Guide d’instlltion
Modèles
N3-REC Boîtier encastré homologué
N3-PLE Boîtier plénum homologué

Risque d’électrocution. Utiliser dans des emplacements secs seulement.
Coupez l’alimentation au niveau du disjoncteur ou enlevez le fusible. Les dommages causés à ce produit par un
câblage sous tension annulent la garantie.
En raison du risque de choc électrique, un électricien agréé doit installer cette unité d’alimentation conformément au
Code national de l’électricité et à tout autre code local ou régional applicable.
Cet appareil est conforme à la partie 15 des règles du FCC. Le fonctionnement est sous réserve des
deux conditions suivantes: ( 1 ) cet appareil ne doit pas provoquer d’interférences nuisibles, et ( 2 ) cet appareil ne
doit accepter aucune interférence reçue, y compris des interférences qui pourraient provoquer un fonctionnement
indésirable.
Must be mounted at least 6 ft (1.8 m) away from wireless interference sources like microwaves, Wireless Access Points
Doit être monté à au moins 1,8m (6pi) des sources d’interférences sans fil comme les micro-ondes, les points d’accès
sans fil (WAP), etc.
Remarque: Cet équipement a été testé et est conforme aux limites d’un appareil numérique de Classe B en vertu de la
partie 15 des règles de la FCC. Ces limites sont conçues pour fournir une protection raisonnable face aux interférences
nuisibles dans une installation résidentielle. Cet équipement génère, utilise et peut émettre une énergie de fréquence
radio et, s’il n’est pas installé et utilisé conformément aux instructions, il peut provoquer des interférences nuisibles
aux communications radio. Cependant, il n’y a aucune garantie que des interférences ne surviendront dans une
installation particulière. Si cet équipement provoque des interférences nuisibles pour la réception radio et télévisuelle,
ce qui peut être déterminé en allumant et en éteignant l’équipement, il est recommandé que l’utilisateur tente de
corriger ces interférences en utilisant une ou plusieurs des mesures suivantes :
• Réorientez ou repositionnez l’antenne réceptrice.
• Augmentez la séparation entre l’équipement et le récepteur.
• Connectez l’équipement à une prise électrique se trouvant sur un circuit diérent de celui où le récepteur
est connecté.
• Demandez l’aide du vendeur ou d’un technicien radio/TV expérimenté.
Cet appareil contient des émetteurs/récepteurs exemptés de licence conformes aux exigences de CNR en matière
d’exemption de licence d’Innovation, Sciences et Développement économique Canada. Le fonctionnement est sous
réserve des deux conditions suivantes:
• Cet appareil ne doit pas provoquer d’interférence.
• Cet appareil doit accepter toutes les interférences, y compris les interférences qui pourraient provoquer un
fonctionnement indésirable de l’appareil.
!AVERTISSEMENT
2|N3 GUIDE D’INSTALLATION
N° de pièce 3662351 Rév B
© 2019 Ketra, Inc. Tous droits réservés.

Contenu
Présentation du produit 4
Pré-installation 5
Instructions de pré-installation 6
Installation 7
Avant le montage physique 7
Montage physique 8
Installation 9
Survol des produits compatibles (Systèmes KetraNet seulement) 11
Garantie et Assistance technique 12
3|N3 GUIDE D’INSTALLATION
N° de pièce 3662351 Rév B
© 2019 Ketra, Inc. Tous droits réservés.

Présentation du produit
Le satellite N3 de Ketra fournit plusieurs fonctions système essentielles: contrôle
des luminaires, intégration de produits de contrôle et d’éclairage tiers, ainsi que des
fonctionnalités de mémoire embarquée et d’horloge astronomique. La connectivité
sans fil du N3 permet son installation dans plusieurs endroits pratiques.
fig.1
Entrée d’alimentation CA
USB
Mises à jour du micrologiciel
Sortie DMX
(autonome seulement)
Indicateurs d’état
E/S multifonctions
(KetraNet seulement)
Entrée/sortie 010V
Entrée/sortie à contacts secs
Entrée de 024 V
Alimentation CA /
Sortie de signal
Raccorder aux luminaires Ketra
4|N3 GUIDE D’INSTALLATION
N° de pièce 3662351 Rév B
© 2019 Ketra, Inc. Tous droits réservés.

Pré-installation
Coupez l’alimentation électrique de tous les disjoncteurs entrant dans le panneau avant d’installer ou
de réparer ce produit.
Une utilisation ou une installation inappropriée peut provoquer des BLESSURES GRAVES, LA MORT
OU DES PERTES OU DES DOMMAGES MATÉRIELS.
Cet appareil doit être protégé par un disjoncteur de 20A.
Cet appareil comprend une radio bidirectionnelle. Pour des performances et une intégrité du
signal optimales:
• Ne pas installer dans des boîtiers métalliques tiers
• Utilisez des boîtiers non métalliques (p. ex., plastique, fibre de verre ou PVC)
Le produit est classé plénum pour les espaces sans traitement d’air.
Le produit est à contact isolant direct.
S’il est placé dans un boîtier à côté d’autres composants électriques, prenez les précautions nécessaires
concernant les températures de fonctionnement.
Le produit est homologué UL pour être monté en surface. Ne nécessite pas de boîtier dédié.
Ce produit contient des connexions électriques de classe1 et de classe2 Les sections sont séparées
physiquement par une barrière. MAINTENIR LA SÉPARATION PHYSIQUE À LA FOIS À L’INTÉRIEUR ET À
L’EXTÉRIEUR DE L’APPAREIL CONFORMÉMENT AUX CODES ÉLECTRIQUES.
Cet appareil doit être installé par un électricien agréé conformément à tous les codes nationaux et locaux.
5|N3 GUIDE D’INSTALLATION
N° de pièce 3662351 Rév B
© 2019 Ketra, Inc. Tous droits réservés.

PRÉINSTALLATION
Instructions de pré-installation
Ce produit possède de nombreuses capacités et fonctions. Toutes les utilisations ne s’appliqueront pas à
chaque application spécifique.
RÉSEAU SANS FIL
• Le produit doit être à portée des commandes de Ketra. Pour plus d’informations, veuillez consulter les
guides d’installation de nos produits de commande.
• Évitez les obstacles métalliques.
• Les murs peuvent avoir un impact sur la communication en fonction de la méthode de construction et
des matériaux.
• Doit être monté à au moins 1,8m (6pi) des sources d’interférences sans fil comme les micro-ondes,
les points d’accès sans fil (WAP), etc.
CONNEXIONS DE COMMANDE
Les limitations de distance pour chaque topologie de commande doivent être prises en compte.
• DMX: 548m (1800pi) maximum.
• 010: Total de 15,2m (50pi) maximum, selon le calibre du fil.
• Contact Sec: Total de 15,2m (50pi) maximum, selon le calibre du fil.
• 24 V: Total de 15,2m (50pi) maximum, selon le calibre du fil.
6|N3 GUIDE D’INSTALLATION
N° de pièce 3662351 Rév B
© 2019 Ketra, Inc. Tous droits réservés.
This manual suits for next models
2
Table of contents
Languages:
Other Ketra Controllers manuals
Popular Controllers manuals by other brands

Bacharach
Bacharach MGS SERIES Installation and operation manual

KOGANEI CORPORATION
KOGANEI CORPORATION ZL1 instruction manual

Ingersoll-Rand
Ingersoll-Rand Intellisys S3 Technician guide

Federal Signal Corporation
Federal Signal Corporation SIGNALMASTER 331102 instruction sheet

D+H
D+H CPS-B1 Original instructions

Botex
Botex DC-1216 manual

Honeywell
Honeywell Aquastat L7224U Quick reference guide

ELGO Electronic
ELGO Electronic P40-SN002 Series Operation manual

GFA
GFA 51171735 00002 Guide

Coolmay
Coolmay EX3G-43HB-24M Programming manual

AEM
AEM LSC22 Installation and operation manual