Keysight 16048A Operation manual

Operation and
Service Manual
Keysight 16048A Test Leads

Notices
© Keysight Technologies
1990-2020
No part of this manual may be
reproduced in any form or by any
means (including electronic storage
and retrieval or translation into a
foreign language) without prior
agreement and written consent from
Keysight Technologies, Inc. as
governed by United States and
international copyright laws.
Trademark Acknowledgments
Manual Part Number
16048-90001
Edition
Edition 8, January 2020
Printed in Malaysia
Published by:
Keysight Technologies International
Japan G.K,
1-3-3 Higashikawasaki-cho
Chuo-ku
Kobe-shi, Hyogo, Japan
Warranty
THE MATERIAL CONTAINED IN THIS
DOCUMENT IS PROVIDED “AS IS,”
AND IS SUBJECT TO BEING
CHANGED, WITHOUT NOTICE, IN
FUTURE EDITIONS. FURTHER, TO
THE MAXIMUM EXTENT PERMITTED
BY APPLICABLE LAW, KEYSIGHT
DISCLAIMS ALL WARRANTIES,
EITHER EXPRESS OR IMPLIED WITH
REGARD TO THIS MANUAL AND
ANY INFORMATION CONTAINED
HEREIN, INCLUDING BUT NOT
LIMITED TO THE IMPLIED
WARRANTIES OF
MERCHANTABILITY AND FITNESS
FOR A PARTICULAR PURPOSE.
KEYSIGHT SHALL NOT BE LIABLE
FOR ERRORS OR FOR INCIDENTAL
OR CONSEQUENTIAL DAMAGES IN
CONNECTION WITH THE
FURNISHING, USE, OR
PERFORMANCE OF THIS
DOCUMENT OR ANY INFORMATION
CONTAINED HEREIN. SHOULD
KEYSIGHT AND THE USER HAVE A
SEPARATE WRITTEN AGREEMENT
WITH WARRANTY TERMS
COVERING THE MATERIAL IN THIS
DOCUMENT THAT CONFLICT WITH
THESE TERMS, THE WARRANTY
TERMS IN THE SEPARATE
AGREEMENT WILL CONTROL.
Technology Licenses
The hardware and/or software
described in this document are
furnished under a license and may be
used or copied only in accordance
with the terms of such license.
Declaration of Conformity
Declarations of Conformity for this
product and for other Keysight
products may be downloaded from
the Web. Go to
http://www.keysight.com/go/confor
mity. You can then search by product
number to find the latest Declaration
of Conformity.
U.S. Government Rights
The Software is “commercial
computer software,” as defined by
Federal Acquisition Regulation
(“FAR”) 2.101. Pursuant to FAR
12.212 and 27.405-3 and
Department of Defense FAR
Supplement (“DFARS”) 227.7202, the
U.S. government acquires
commercial computer software
under the same terms by which the
software is customarily provided to
the public. Accordingly, Keysight
provides the Software to U.S.
government customers under its
standard commercial license, which
is embodied in its End User License
Agreement (EULA), a copy of which
can be found at
http://www.keysight.com/find/sweul
a The license set forth in the EULA
represents the exclusive authority by
which the U.S. government may use,
modify, distribute, or disclose the
Software. The EULA and the license
set forth therein, does not require or
permit, among other things, that
Keysight: (1) Furnish technical
information related to commercial
computer software or commercial
computer software documentation
that is not customarily provided to
the public; or (2) Relinquish to, or
otherwise provide, the government
rights in excess of these rights
customarily provided to the public to
use, modify, reproduce, release,
perform, display, or disclose
commercial computer software or
commercial computer software
documentation. No additional
government requirements beyond
those set forth in the EULA shall
apply, except to the extent that those
terms, rights, or licenses are
explicitly required from all providers
of commercial computer software
pursuant to the FAR and the DFARS
and are set forth specifically in
writing elsewhere in the EULA.
Keysight shall be under no obligation
to update, revise or otherwise modify
the Software. With respect to any
technical data as defined by FAR
2.101, pursuant to FAR 12.211 and
27.404.2 and DFARS 227.7102, the
U.S. government acquires no greater
than Limited Rights as defined in FAR
27.401 or DFAR 227.7103-5 (c), as
applicable in any technical data.
Safety Notices
A CAUTION notice denotes a hazard. It
calls attention to an operating
procedure, practice, or the like that,
if not correctly performed or adhered
to, could result in damage to the
product or loss of important data. Do
not proceed beyond a CAUTION
notice until the indicated conditions
are fully understood and met.
A WARNING notice denotes a hazard.
It calls attention to an operating
procedure, practice, or the like that,
if not correctly performed or adhered
to, could result in personal injury or
death. Do not proceed beyond a
WARNING notice until the indicated
conditions are fully understood and
met.

Contents
Keysight 16048A Test Leads 3
Table of Contents
1. Operation
Product Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Typical Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Compensation for Fixture Residual Impedance Error . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
2. Service
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

4 Keysight 16048A Test Leads
Contents

5
Keysight 16048A Test Leads
Operation and Service Manual
1 Operation
This operating note provides complete information on the 16048A Test Leads.
The 16048A is shown pictorially in Figure 1-1, its physical dimensions are given
in Table 1-1, and typical characteristics related to offset error are given in Table
1-2. To order additional copies of this operating note, use the option number
listed on www.keysight.com.
Product Description
The 16048A consists of a direct attachment, 4-terminal pair type fixture which
is equipped with four BNC (m) terminated-coaxial test leads. These test leads
are used to attach user-fabricated test fixtures. DC bias levels of up to ±42V
can be applied to the 16048A. Cable length is 1 meter. The 16048A is shown in
Figure 1-1.
Figure 1-1 Product Overview

6 Keysight 16048A Test Leads
Operation
Specifications
1-
Specifications
Table 1-1 Specifications of the 16048A
Function: For use with 4 terminal-pair LCR Meters
and Impedance Analyzers.
Connector Type: BNC male
Cable Length: Approximately 1m
Maximum Voltage: ± 42V peak max. (AC+DC)
Frequency Range: DC to 30 MHz
Weight: 315 g
Safety Standards: EN61010-1:1993 +A2:1995
IEC61010-1:1990 +A1:1992 +A2:1995
CSA C22.2 No.1010.1:1992
INSTALLATION CATEGORY I
POLLUTION DEGREE 2
INDOOR USE

Keysight 16048A Test Leads 7
Operation
Typical Characteristics
Typical Characteristics
Figure 1-2
Table 1-2 Typical Characteristics
Incremental error at freq ≥1 MHz.
Parameter reading error (%) Offset value for D
f is the measurement frequency in megahertz. The incremental errors
calculated from the equation in the table for measurements at frequencies
above 1 MHz are additive.
5f
10
------
2
0.02 f
10
------
2

8 Keysight 16048A Test Leads
Operation
Compensation for Fixture Residual Impedance Error
1-
Compensation for Fixture Residual Impedance Error
The 16048A has inherent stray capacitance, residual inductance, and residual
resistance that affect the accuracy of measured values. To compensate for, or
negate, these residuals to minimize measurement error, the instrument’s
Open/Short compensation procedure should be performed. The procedure is
given in the instrument’s operating manual.

9
Keysight 16048A Test Leads
Operation and Service Manual
2Service
Introduction
This chapter gives the service information for the 16048A.
Serial Number for Non-RoHS 16048A:
“MY44100001 – MY44199999” or “SG44100001 – SG44199999”
Serial Number for RoHS 16048A:
“MY44200001 and above” or “SG44200001 and above”.
Maintenance
Shown are the supported parts and their respective RoHS compliant
replacement support part. RoHS conversion involves with design and
dimension change which result in the RoHS support part backward
incompatible with non-RoHS 16048A. Special handling is needed while using
the RoHS replacement part on non-RoHS 16048A. The original support part
number is replaced by the respective “RoHS Compliant Replacement Part”.
Do not disassemble any further than shown. Maintenance consists principally
of cleaning contacts and replacing worn or damaged parts. Take special care
when cleaning contacts. To order parts, use the Keysight Technologies part
numbers listed in Table 2-1. If a faulty part is located in an assembly that
cannot be disassembled, order the next higher assembly or return the whole
device to the nearest Keysight Technologies Sales/Service Office for repair or
replacement.

10 Keysight 16048A Test Leads
Service
Maintenance
2-
Figure 2-1 Parts Identification

Keysight 16048A Test Leads 11
Service
Maintenance
Table 2-1 Replaceable Part
Ref
/D
Non-RoHS
Part No.
Description Qty RoHS
Compliant
Replacement
Part
Description Qty
1*SLEEVE 4 * - 4
2* NUT 4* - 4
3* NUT 4* - 4
4 * WASHER 4 * - 4
5 * WASHER 4 * - 4
6 2360-0192 SCREW 2 16048-60610 TEST LEAD 2
7* COVER-BOTTOM1* - 1
8 * INSULATOR 4 * - 4
9 * CONNECTOR-BNC 2 * - 2
10 * CONNECTOR-BNC 2 * - 2
11 2200-0103 SCREW 1 * - 1
12 2190-0206 WASHER 1 * - 1
13 16047-40000 STOPPER 1 * - 1
15 16048-04000 COVER-TOP 1 16048-60610 TEST LEAD 1
16 1400-0719
(1400-3284)
CABLE TIE 2 1400-3284 CABLE TIE 2
17*GROMMET1*-1
18 * CABLE 1 * - 1
19 * BUSHING 1 * - 1
21 2360-0115 SCREW 1 16048-60610 TEST LEAD 1
22 3050-0010 WASHER 1 16048-60610 TEST LEAD 1
23 16021-50021 CABLE CRAMP 1 16048-60610 TEST LEAD 1
24 16021-50022 CABLE CRAMP 1 16048-60610 TEST LEAD 1
25*BOOT-BNC4*-4
26*SLEEVE4*-4
27*SLEEVE4*-4
28 * INSULATOR 4 * - 4

12 Keysight 16048A Test Leads
Service
Maintenance
2-
29 1250-0089 CONTACT 4 1250-0089 CONTACT 4
30 1250-0052 CONNECTOR-BNC 4 1250-0052 CONNECTOR
-BNC
4
16048-60010 TEST LEAD
(1 thru 30)
1 16048-60610 TEST LEAD 1
31 1250-0118 CONNECTOR-BNC
FEMALE
4 1250-0118 CONNECTOR
-BNC
FEMALE
4
32 2360-0115 SCREW 2 aSet Change:
0515-0372
SCREW 2
33 16032-10021 PLATE 1 aSet Change:
16032-10621
PLATE 1
34 2190-0016 WASHER 4 2190-0016 WASHER 4
35 2950-0001 NUT 4 2950-0001 NUT 4
36 16032-10022 PLATE 1 aSet Change:
16032-10622
PLATE 1
37 16032-60001 BNC BRACKET
(31 thru 36)
1 16032-60071 CONNECTOR
ASSEMBLY
1
a. Replace all the associated parts marked with aas they are mutually dependent.
*. Not separately replaceable.Order 16048-60010.
Table 2-1 Replaceable Part
Ref
/D
Non-RoHS
Part No.
Description Qty RoHS
Compliant
Replacement
Part
Description Qty

This information is subject to change without notice.
© Keysight Technologies 1990-2020
Edition 8, January 2020
*16048-90001*
16048-90001
www.keysight.com
Table of contents
Other Keysight Cables And Connectors manuals