P/N P-047550-1818-EN • REV 03 • ISS 10MAR16 1 / 2
GSA-IPHS Intelligent 4D
Multisensor Smoke Detector
Installation Sheet
Description
The Signature Series GSA-IPHS Intelligent 4D Multisensor Smoke
Detector is an intelligent analog device that contains ionization and
photoelectric smoke sensors plus a heat sensor. The detector
analyzes the data from all three sensors to determine when an alarm is
initiated.
The detector continuously monitors changes in sensitivity and notifies
the loop controller of its condition. It issues a dirty-sensor warning
when it reaches a preset limit. This notifies the operator of the need for
service while the detector still operates within UL/ULC limits.
LEDs: The GSA-IPHS has two LEDs that show its state.
• Normal: Green LED flashes
• Alarm/active: Red LED flashes
• Stand-alone alarm: Green and red LEDs glow continuously
Electronic addressing: The loop controller automatically assigns
addresses to the detectors. Custom addresses can be assigned to the
detectors via laptop computer. No addressing switches are used.
Stand-alone operation: If isolated from the loop controller, the
detector alarms when smoke levels exceed a preset value. See the
applicable control panel manual to verify stand-alone capability.
Self-diagnostics: The GSA-IPHS contains a microprocessor capable
of performing comprehensive self-diagnostics and storing the results.
Details such as hours of operation, last maintenance date, sensitivity
values, and number of alarms and troubles are stored in nonvolatile
memory. These can be retrieved and reviewed as desired.
Installation
WARNINGS
• This detector does not operate without electrical power. As fires
frequently cause power interruption, discuss further safeguards
with your local fire protection specialist.
• This detector will not sense fires in areas where smoke cannot
reach the detector. Smoke from fires in walls, roofs, or on the
opposite side of closed doors may not reach the detector.
• Ionization detectors are best suited for detecting fast, flaming fires.
Photoelectric detectors are best suited for detecting slow,
smoldering fires. The heat sensor in this device provides a source
of supplemental information to that provided by the other sensors.
The heat sensor by itself does not provide life safety protection.
Notes
• The dust cover (supplied) must remain on the detector during
installation, and then be removed prior to operation. The dust
cover is not a substitute for removing the detector during new
construction or heavy remodeling.
• Do not use a detector guard with this detector unless the
combination has been evaluated and found suitable.
• To ensure proper operation, store the detector within the
recommended ranges. Allow the detector to stabilize to room
temperature before applying power.
• Maintenance (regular or selected) should be planned in
accordance with the requirements of the authority having
jurisdiction to ensure proper operation. Refer to NFPA 72 and
CAN/ULC-S536.
• Under normal conditions this unit does not require calibration. If
calibration is required, call Customer Service at 1-800-655-4497 to
arrange for return to the factory.
See Technical Bulletin P/N 270659-EN for additional information
and cleaning instructions.
• NFPA code requires that a calibrated sensitivity test be performed
upon completion of the original installation and following any
modifications or additions to the system. Signature Series devices
can perform this test and generate a system sensitivity report.
• In Canada, your installation must meet the requirements of
CAN/ULC-S524 Standard for the Installation of Fire Alarm
Systems, and the local authority having jurisdiction.
• Test the detector with Smoke Detector Tester and Model 1490
Adapter/Tube Accessory, manufactured by Home Safeguard, Inc.
or SOLO A4 aerosol manufactured by SDi.
To install the detector:
1. Push a small screwdriver into the tamper-resist access slot while
rotating the detector counterclockwise to remove the detector.
You can permanently disable the tamper-resist mechanism by
breaking and removing the plastic lever arm from the base. See
Figure 1 for the locations of tamper-resist features.
2. Install and wire the base as described in the installation sheet
supplied with the base.
3. Remove the serial number label from the detector and attach it to
the project documentation.
4. Connect the detector to the base by rotating the detector clockwise
until it snaps into the locked position.
5. Before initial testing, remove the dust cover from the detector and
notify the proper authorities that the fire alarm system is
undergoing maintenance and will be temporarily out of service.
2 / 2 P/N P-047550-1818-EN • REV 03 • ISS 10MAR16
Figure 1: Tamper resist features
(1) Tamper-resist lever arm on base (break off to disable)
(2) Access slot for tamper-resist mechanism
Specifications
Voltage 15.2 to 19.95 VDC
Current
Normal
Alarm
Stand-alone alarm
45 µA
45 µA
18 mA
Ionization source Americium 241, 0.14 μCi
A
larm point
temperature
60 to 70°F (33 to 38°C) above ambient
A
i
r
velocity 0 to 5,000 ft./min (0 to 25.39 m/s)
UL/ULC smoke
sensitivity
0.67 to 3.70%/ft. obscuration
Environmental
compensation
Automatic
Distance from ceiling
(wall mounted)
12 in. (305 mm) max.
Compatible bases
Standard
Relay
Isolator
Audible
GSA-SB, GSA-SB4
GSA-RB, GSA-RB4
GSA-IB, GSA-IB4
GSA-AB4, GSA-AB4G, GSA-SBT,
SIGA-AB4G-LF
Operating environment
Temperature
Relative humidity
Altitude
32 to 120°F (0 to 49°C)
0 to 93% noncondensing
6,000 ft. (1,828 m) max.
Storage temperature −4 to 140°F (−20 to 60°C)
Contact information
For contact information, see www.kiddelifesafety.com.
© 2016 Walter Kidde Portable Equipment, Inc.
All rights reserved.
(1)
(2)

This manual suits for next models

1

Other Kidde Smoke Alarm manuals

Kidde PI9000 User manual

Kidde

Kidde PI9000 User manual

Kidde RF-SM-ACDC User manual

Kidde

Kidde RF-SM-ACDC User manual

Kidde P3010H User manual

Kidde

Kidde P3010H User manual

Kidde 29D User manual

Kidde

Kidde 29D User manual

Kidde P3010CU User manual

Kidde

Kidde P3010CU User manual

Kidde P3010K-CA User manual

Kidde

Kidde P3010K-CA User manual

Kidde RF-SM-DC User manual

Kidde

Kidde RF-SM-DC User manual

Kidde RF-SND User manual

Kidde

Kidde RF-SND User manual

Kidde 0910UK Assembly instructions

Kidde

Kidde 0910UK Assembly instructions

Kidde FIRE SENTRY 0914 User manual

Kidde

Kidde FIRE SENTRY 0914 User manual

Kidde 916 User manual

Kidde

Kidde 916 User manual

Kidde P4010ACSCO-W User manual

Kidde

Kidde P4010ACSCO-W User manual

Kidde I240C User manual

Kidde

Kidde I240C User manual

Kidde KN-COSM-IBACA (900-0119) User manual

Kidde

Kidde KN-COSM-IBACA (900-0119) User manual

Kidde P3010CU User manual

Kidde

Kidde P3010CU User manual

Kidde PI9010 User manual

Kidde

Kidde PI9010 User manual

Kidde 2070-VASR User manual

Kidde

Kidde 2070-VASR User manual

Kidde KN-COSM-BCA User manual

Kidde

Kidde KN-COSM-BCA User manual

Kidde P4010ACLEDS-2 User manual

Kidde

Kidde P4010ACLEDS-2 User manual

Kidde 1235 User manual

Kidde

Kidde 1235 User manual

Kidde AirSense Stratos Micra 25 User manual

Kidde

Kidde AirSense Stratos Micra 25 User manual

Kidde KN-COSM-XTR-B User manual

Kidde

Kidde KN-COSM-XTR-B User manual

Kidde i12020ACA User manual

Kidde

Kidde i12020ACA User manual

Kidde KN-COSM-XTR-B User manual

Kidde

Kidde KN-COSM-XTR-B User manual

Popular Smoke Alarm manuals by other brands

Vision ZS6301N Installation & operation manual

Vision

Vision ZS6301N Installation & operation manual

teko Astra-Z-4545 Operation manual

teko

teko Astra-Z-4545 Operation manual

GE TX-6010-01-1 manual

GE

GE TX-6010-01-1 manual

Gamewell 7100 series Installation & operation manual

Gamewell

Gamewell 7100 series Installation & operation manual

Marmitek SD90 Advanced Use

Marmitek

Marmitek SD90 Advanced Use

Fireray 50RV install guide

Fireray

Fireray 50RV install guide

BeeSecure BEE-SD user manual

BeeSecure

BeeSecure BEE-SD user manual

Pro-tec CIRRUS HYBRID Installation and commissioning manual

Pro-tec

Pro-tec CIRRUS HYBRID Installation and commissioning manual

Vision ZS 6101 IN-5 Installation & operation manual

Vision

Vision ZS 6101 IN-5 Installation & operation manual

First Alert 9120 Series user manual

First Alert

First Alert 9120 Series user manual

SOMFY Smoke Detector user manual

SOMFY

SOMFY Smoke Detector user manual

elsner elektronik KNX AQS/TH Installation and adjustment

elsner elektronik

elsner elektronik KNX AQS/TH Installation and adjustment

B-Link FUME instructions

B-Link

B-Link FUME instructions

aguilera AE/SA-OPZ user manual

aguilera

aguilera AE/SA-OPZ user manual

VESDA VLP Maintenance Guide

VESDA

VESDA VLP Maintenance Guide

Firex KF30 user manual

Firex

Firex KF30 user manual

Numens 205DC user manual

Numens

Numens 205DC user manual

Fenwal FLS-02EC instruction manual

Fenwal

Fenwal FLS-02EC instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.