7. OPERATING AND TESTING YOUR SMOKE ALARM
Sound Em tted
Vo ce Prompt
(Model WFPV)
LED (all) & Escape L ght
(Model WFPL)
Note
Normal
Operation
None None Flashes once every 10 minutes LED will flash every 60seconds for 10
minutes after power-up, then flashes
every 10 minutes
Test 3 long beeps repeated
twice
“FIRE, FIRE!” Flashes with alarm pattern
(Model WFPL briefly
illuminates amber safety light)
None
Alarm 3 long beeps, repeating “FIRE, FIRE!”
3 x flashes, synchronised with audi-
ble alarm (and illumination of amber
safety light for model WFPL)
Identify source of smoke and
evacuate if necessary
Low Battery ingle chirp every 60
seconds
“Low Battery” Flashes once every 30 seconds Deactivate the alarm and replace
within 7 days
Hush
ee NOTE 1
“Hush Mode Activated”
Flashes every 10 seconds for 10
minutes
Hush
Cancellation
“Hush Mode Cancelled” Cancelled by pressing test button
Fault Mode ingle chirp every 30
seconds
Fault Code (2-12 flashes every
30 seconds)
End of Life
ee NOTE 2
2 chirps every 30 sec-
onds
Flashes twice every 30 seconds
Note 1 – Pre ing the Te t/Hu h bu#on will de en i"ze the alarm for 10 minute to a known alarm condi"on uch a burnt toa t.
During thi period the LED fla he every 10 econd .
Note 2 – Pu hing the Te t/Hu h bu#on at end of life ilence End of Life chirp for 3 day . Can be u ed 10 "me within 30 day .
Allow the homeowner to purcha e a replacement alarm.