SAFETY
FOLLO THESE INSTRUCTIONS CAREFULLY
Proper installation of the Parallel Cable Kit is essential for safe and reliable operation.
ARNING!
This Parallel Cable Kit must ONLY be used between two identical Inverter
Generators. Never connect cables between two different inverter generators, this may
cause low voltage output, which can permanently damage the electrical devices
connected to the inverter generators.
Before use, read and understand the installation and operation instructions in this manual
to become familiar with how this Parallel Cable Kit works with two Inverter Generators with
parallel ports.
Periodically inspect the cables for damage, replace cable if its insulation is broken or
cracked.
INSTALLATION
1) Connect the two parallel connectors (A)
Fig.1 from one cable to the parallel inputs
(B) on the control panel of the first Inverter
Generator.
2) Connect the two parallel connectors from
the other cable to the parallel inputs on the
control panel of the second Inverter
Generator.
3) Attach the ground wire (C) Fig.1 to the ground terminal (D) on the control panel of the
first Inverter Generator.
4) Attach the second ground wire to the ground terminal on the control panel of the
second Inverter Generator.
SAFE Y AND INS ALLA ION
Figure 1
OPERA ION
OPERATION
arning! If high electrical loads are
connected, turn the Eco switch (A) Fig.2 to
the Off position to reduce voltage changes.
While both Inverter Generators are running,
make sure both green power indicator lights
(B) are On. If not On, turn the Inverter
Generators Off, restart both Inverter
Generators and make sure both green power
indicator lights are On.
arning! Substantial overloading (exceeding
the rated output of 30 Amps.) will shut off the AC output. Exceeding maximum power or
slightly overloading the Inverter Generators may not switch the AC circuit protector Off, but
will shorten the service life of the Inverter Generators. Do not overload.
arning! Only use one Parallel Cable receptacle at a time
(NEMA L5-30R or the NEMA -30R). When using the
Parallel Cable Kit, the 120V duplex receptacles on the
Inverter Generator control panels can not be used, only the
receptacles on the Parallel Cable box can be used.
his Parallel Cable kit comes with two receptacles;
• NEMA L5-30R wist Lock Receptacle (A) Fig.3- Rated for
120V, max. 30 Amps. Powers electrical items having a 3
prong NEMA L5-30P wist Lock plug.
• NEMA -30R RV Receptacle (B) Fig.3-Rated for 120V,
max. 30 Amps. Connect an RV power cable having a 3
prong -30P RV plug.
Figure 2
Figure 3