King gates FREDDY2 Technical specifications

FREDDY2
EN Instructions and warnings for installation and use
Made in Italy

1
J1
2
FIG.1
FIG.2

EN
EU DECLARATION OF CONFORMITY
V2 SpA hereby declares that the products: FREDDY2
comply with the following directives:
99/05/CEE, ROHS-3 2015/863/EU
Racconigi, 01/07/2020
Legal representative of V2 S.p.A.
Sergio Biancheri
DISPOSAL
As for the installation operations, even at the end of this product’s
life span, the dismantling operations must be carried out by
qualified experts.
This product is made up of various types of materials: some can
be recycled while others need to be disposed of.
Find out about the recycling or disposal systems envisaged by your
local regulations for this product category.
Important! – Parts of the product could contain pollutants or
hazardous substances which, if released into the environment,
could cause harmful effects to the environment itself as well as
to human health.
As indicated by the symbol opposite, throwing away this product
as domestic waste is strictly forbidden. So dispose of it as
differentiated waste, in accordance with your local regulations,
or return the product to the retailer when you purchase a new
equivalent product.
Important! – the local applicable regulations may envisage
heavy sanctions in the event of illegal disposal of this product.
PRODUCT DESCRIPTION AND
INTENDED USE
The receivers in this series are intended for controlling the
automation type door openers, gate openers and the like, lights
and electrical circuits in general.
Any other use is improper and prohibited!
Specifications:
• Monostable, bistable or timer operating logic.
• Possibility to select the contact type (N.A or N.C.) of the relay
1 through a dedicated jumper J1.
The contact of relay 2 is of N.A. type, to have an N.C. contact.
It is necessary to make changes to the hardware of the printed
circuit
• It is possible to store up to 504 different codes with
self-learning mode
• Memory full warning: the receiver blinks 15 times
• Self-learning of transmitters managed by radio
RELAY CONTACTS
The contacts to the terminal board concerning the four relays are
of normally open (N.O.) type.
For a normally closed (N.C.) contact of relay 1, move the jumper
J1 to position 2 (Fig. 1).
For a normally closed contact (N.C.) of relay 2 short-circuit point
A with point B and cut the track at point C (Fig. 2) of the relay
concerned.
TECHNICAL DATA
Frequency 433,92 MHz
Power supply 12 - 24 Vac / 12 - 36 Vdc
Relay contacts 1A / 30Vdc
Temperature -20 ÷ +60°C
Consumption 16 mA @ 24Vdc (stand by)
Sensibility ≥ -103 dBm
S/N > 17dB @ 100dBm m=100%
Size 132 x 26 x 74 mm
Protection degree IP55
PROGRAMMING
mIMPORTANT: to memorize the code in the correct way
it is necessary to keep a minimum distance of 1,5 metres
between the transmitter and the receiver’s antenna.
The self learning programming system enables the code
memorization and the setting of the following functioning modes:
MONOSTABLE: it activates the corresponding relay through the
time of TX transmission. When the transmission stops, the relay
goes automatically off.
BISTABLE: it activates the corresponding relay on the first TX
transmission. The relay goes off on the second transmission.
TIMER: the tx transmission activates the corresponding relay
which goes off after the set time (max 7,5 minutes).
SELECTION OF THE RECEIVER
CHANNEL
To select the channel of the receiver to be programmed, press
the P1 button for N times, as indicated in the table: the LED
corresponding to the selected channel turns on
SELECTED
CHANNEL
N°
IMPULSES P1
LED ON
L1 L2
CHANNEL 1 1 •
CHANNEL 2 2 •
PROGRAMMING OF THE MONOSTABLE
FUNCTION
1. Select the channel of the receiver to be programmed
2. Within 5 seconds, press and hold the button on the remote
control (about 2 sec.)
3. The led of the receiver goes out and goes on again: the code
has been memorised and the receiver remains standby for 5 s
with a new code to be memorised
4. Memorise all the remote control units necessary
5. After 5 seconds without a valid transmission, the led is turned
off and the receiver returns to normal operating mode

EN
PROGRAMMING THE TIMER FUNCTION
1. Select the channel of the receiver to be programmes and hold
pressed the P1 button: the LED corresponding to the selected
channel will turn on for a few seconds
2. When the led goes off, release the P1 button.
3. The led starts a sequence of flashings at low speed (1 flash
per second). The number of flashing corresponds to the time
which can be set as shown in the table.:
N° Flashing Time N° Flashing Time
1 01 sec. 17 1 min.
2 02 sec. 18 1,5 min.
3 03 sec. 19 2 min.
4 04 sec. 20 2,5 min.
5 05 sec. 21 3 min.
6 06 sec. 22 3,5 min.
7 07 sec. 23 4 min.
8 08 sec. 24 4,5 min.
9 09 sec. 25 5 min.
10 10 sec. 26 5,5 min.
11 11 sec. 27 6 min.
12 12 sec. 28 6,5 min.
13 13 sec. 29 7 min.
14 14 sec. 30 7,5 min.
15 15 sec. 31 BISTABLE
16 30 sec.
4. Count the number of led flashings corresponding to the time
you wish to set
5. Press the rx button P1 during the wished flashing: the
sequence of flashings stops and the led remains on
6. Within 5 seconds, press and hold the button on the remote
control (about 2 sec.)
7. The led on the receiver is turned off and then comes on
again: the code has been memorised and the receiver remains
standby for 5 s with a new code to be memorised
8. Memorise all the remote control units necessary
9. After 5 seconds without a valid transmission, the led is turned
off and the receiver returns to normal operating mode
PROGRAMMING OF THE BISTABLE
FUNCTION
1. Select the channel of the receiver to be programmes and hold
pressed the P1 button: the LED corresponding to the selected
channel will turn on for a few seconds
2. When the led goes off, release the P1 button.
3. The led starts a sequence of flashings at low speed (1 flash per
second). When the 30 flashings of the timer function are over,
the led remains on.
4. Within 5 seconds, press and hold the button on the remote
control (about 2 sec.)
5. The led on the receiver is turned off and then comes on
again: the code has been memorised and the receiver remains
standby for 5 s with a new code to be memorised
7. Memorise all the remote control units necessary
8. After 5 seconds without a valid transmission, the led is turned
off and the receiver returns to normal operating mode
REMOTE RADIO LEARNING
This procedure allows to memorize new transmitters by radio, in
sequence and without removing the receiver from the installation.
The transmitter which allows to enable the programming
by radio must be memorized in advance.
The keys of all the transmitters saved in the memory via radio will
have the same logic as for those of the transmitter that enabled
programming.
Therefore, if the transmitter that activated programming has key 1
saved only, the new transmitters can only be saved using key 1.
1. Press for at least 4 seconds the keys 1+2 of one transmitter
that is already saved
2. Release both keys
3. Press, within 5 seconds, the key of the new transmitter that
you intend to save
4. Release the key and repeat the procedure for the other keys of
the remote control or with other radio controls to be saved
CANCELLATION OF A SINGLE
TRANSMITTER
1. Turn off the power to the receiver
2. Holding down the P1 key, reactivate the power supply: LED L1
lights up steadily for a few seconds then starts flashing
3. During flashing, release the P1 key: LED L1 turns on steadily
4. Hold down a key of the transmitter that you want to delete:
LED L1 turns off and on again
5. Release the key: the transmitter has been deleted (all keys
memorized) and the receiver remains on hold for 5 sec. of
another transmitter to be deleted
6. After 5 seconds without any operation, the LED turns off and
the receiver returns to normal operation
NOTE: if you try to delete a transmitter that is not
memorized, the L1 LED flashes multiple times
TOTAL CANCELLATION OF
TRANSMITTERS
1. Turn off the power to the receiver.
2. Holding down the P1 key, reactivate the power supply: LED L1
lights up steadily for a few seconds then starts flashing
3. Keep the button pressed until LED L1 remains on steady
4. Release the P1 key: the total cancellation is started and ends
after a few seconds when the LED goes out
Manufacturer's details
Brand of V2 S.p.A.
Corso Principi di Piemonte 65/67 - 12035 RACCONIGI CN (ITALY)
Other manuals for FREDDY2
1
Other King gates Home Automation manuals
Popular Home Automation manuals by other brands

GTV
GTV PRESTINO AE-PB2FPRES-20 instructions

Johnson Controls Unitary Products
Johnson Controls Unitary Products S1-TTSCC Zoning User's Information Manual

PEAKnx
PEAKnx Controlmicro Getting started

Linksys
Linksys PLWK400 Setting up a wireless network

Hive
Hive SLP2d user guide

V-TAC
V-TAC VT-5145 Installation instruction