Kingdun Electronic LM-109E User manual

Ningbo Kingdun Electronic Industry Co.,Ltd.
Page 1 of 10
Document
No.
QSP0701-A-31095-
401
Version
A/1
Model No.
LM-109E
Date
2016-6-15
Pages
10
LM-109E SMOKE ALARM
User manual
Prepared by:Liu Xueyong
Audit:Fang Yongda
Approved by:Long Xinglin

Ningbo Kingdun Electronic Industry Co.,Ltd.
Page 2 of 10
Product Specifications:
Technical
parame-
ters
Smoke detector
Voltage
DC3V(built-in CP952434)
Low-voltage
inspection
2.2V
current
Working current
Quiescent current
≤120mA
≤2uA
Alarm loud-
ness
≥85dB/3m
Working
temperature
-10℃~+40℃
Ambient
humidity
≤95%RH(no condensation)
Status dis-
play
Normal smoke detection
LED (red) flashes once about every 344
seconds, no alarm sound
Smoke detection or key test
LED (red) flashes and continuous alarm is
given
Low sensitivity detection (silent
mode)
LED (red) flashes about every 10 seconds, no
alarm sound, automatically cancel low sensi-
tivity detection about 9 minutes later
Alarm memory
LED (green) flashed 3 times about every 43
seconds, and stops 24 hours later. The first
time you press test/mute button after alarm is
made, the detector will hint by special alarm
mode.
End of useful life
After working for 10 years, alarm sound is
made, the buzzer buzzes 3 times about
every 43 seconds
Low-voltage inspection
LED (red) flashes once, make “di” alarm
sound about every 43 seconds

Ningbo Kingdun Electronic Industry Co.,Ltd.
Page 3 of 10
Appearance and dimension(Figure 1)
LM-109E
(Figure1)
Operation:
•In areas where ventilation and/or air conditioning systems are used is must be ensured that air
movement does not affect the function of the smoke detector.
•Smoke detectors must be permanently fixed on the ceiling. Mounting instructions must be observed.
•Choose a mounting method that ensures a holding force of at least 20N in vertical direction.
•The smoke detector is designed for monitoring residential buildings or residential premises (not for
industrial or commercial usage).
•A function test must be performed on each smoke detector after installation.
•The functionality of each installed smoke detector must be regularly checked and maintenance
measures must be ensured. Perform function test 1 per week, clean every 3 months.
•Smoke detectors must be taken out of service at the latest after 10 years and replaced with a new
device.
Mounting locations
Mounting locations for smoke detectors:
•Bedrooms, children’s rooms and corridors must be equipped (basic requirement) with smoke detec-
tors.
•Always on the ceiling.
•50 cm from the wall (or beam).
•If the room is subdivided by ceiling-high furniture etc., a smoke detector must be installed in each
room partition.
•In rooms with a floor area ≤60m2, divided into ceiling boxes by beams or joists, the following ap-
plies:
oIn ceiling boxes bigger > 36m2 a smoke detector must be installed per ceiling box (see Fig-
ure 1a).
oIn ceiling boxes ≤36m2 and with ceiling slopes ≤20°as well as beams or joists with a height
≤0.2m, the individual ceiling boxes are not taken into account (see Fig 1.b). Install smoke
detectors as centrally as possible in the room, in a ceiling box or on the joist.

Ningbo Kingdun Electronic Industry Co.,Ltd.
Page 4 of 10
oIn these rooms have beams or ceiling joists with a height >0,2m, the smoke detector must
be installed on a beam or girder, as centrally as possible in the room (see Fig c).
•In rooms with a floor area of >60m2, an additional smoke detector must be installed per 60m2.
Planning examples
For apartments and single family homes
Example for use in a single-family home

Ningbo Kingdun Electronic Industry Co.,Ltd.
Page 5 of 10
Arrangement in special room geometries
Following distance ratios and arrangements are recommended for detector positioning:
a) Linear corridor
b) Rectangular corridor
c) Detector arrangement in large corridors
d) Detector arrangement in large corridors with corners
Constructional features
•If a room is divided in height by a podium or a gallery, a smoke detector is required beneath these

Ningbo Kingdun Electronic Industry Co.,Ltd.
Page 6 of 10
installations if the area exceeds 16m2 and the length and width exceeds each 2m.
•In rooms with ceiling slopes > 20°to the horizontal, a heat pocket can form at the top of the ceiling
which prevents smoke entry into the smoke detector.
•Therefore, smoke detectors in these rooms must be mounted at least 0,5m but no more than 1m
from the ceiling top, see the following 2 illustrations.
•In rooms with a slope ≤20°smoke detectors must be mounted centrally on the ceiling.
Example of mounting with pedestal-shaped ceiling with a ceiling slope > 20°
Remarks: smoke detectors can be attached on the position left (1) or on the position right (2).
Notes for ceiling installation.
For ceiling with joists (height (h) of the joist ≤0.20m and an area of the ceiling box >36m2 or ≤36m2).
a) Example for ceiling >36m2
b) Example for ceiling box ≤36m2
c) Example of ceiling with joist (height (h) of the joist >0.2m)
In corridors with a maximum width of 3m, the distance between two smoke detectors may not exceed 15m.
The detector distance to the front face of the corridor must not exceed 7.5m. A detector must be arranged
in crossings, junctions and corners (mitre line) of corridors. An example of an arrangement is shown in chap-
ter “Arrangement in special room geometries”.

Ningbo Kingdun Electronic Industry Co.,Ltd.
Page 7 of 10
Mounting
Loosen the mounting plate on the rear side of the device by turning it clockwise.
Fix the mounting plate with the help of the enclosed mounting material to the ceiling or wall. Check
first whether the supplied mounting materials is suitable for the structural quality of the wall/ceiling.
Insert the smoke detector in the mounting bracket and rotate the smoke detector anti-clockwise direc-
tion until it audibly engages.

Ningbo Kingdun Electronic Industry Co.,Ltd.
Page 8 of 10
Power off Power on
The battery pin is raised at beginning of use (left photo). Press battery pin to power on (right photo).
Test after the installation.
Press the test/hush button, if the red indicator light flashes quickly and continue alarms at the same
time, it means the detector is working properly. At the same time, the detector enters low sensitivity
detecting state, the red LED light flashes every 10 seconds approx. About 9 minutes later, it enters
normal detecting state from low sensitivity detecting state automatically. Or press the test/mute button
again and cancel low sensitivity detecting state.
Erratic or low sound coming from your alarm may indicate a defective alarm, you can refer to “Trouble
shooting”section for solution.

Ningbo Kingdun Electronic Industry Co.,Ltd.
Page 9 of 10
LED indicators
•RedLED-flashing once every 344 seconds: indicates that the smoke alarm device is operating proper-
ly.
•Red LED-flashing: when the test button is pressed, or when the smoke alarm device sense particles
of combustion and goes into alarm (constant pulsating sound), the red LED will flash once per
second. The flashing LED and pulsating alarm will continue until the air is cleared or release test
button.
•Red LED alarm silencer (Hush mode) indication: The red LED will flash once every 10 seconds, indi-
cating the smoke alarm device is in the alarm silence (hush) mode.
•Low battery indication: An intermittent “chirp”with red LED flashes once every 43 seconds: indicates
that the smoke alarm device is low battery, you may press the test button longer time for pause
alarm for 8 hours, but it will reset automatically after 8 hours.
•Fault indication: the alarm occurs every 43 seconds.
•Alarm memory: After alarm is made, the detector will have alarm memory. The green LED will
flash quickly for 3 times every for 43 seconds. So the user can tell if the detector has entered
alarm state from a distance without touching the detector. LED display will quit after 24 hours.
The first time you press the test/mute button after alarm is made, the detector will hint by spe-
cial alarm mode. After releasing the test/mute key, alarm memory will be reset. Then you press
the test/mute button and it will be normal key test.
Alarm silence (hush mode)
During the unit is alarming, you push the test button, it will be paused the unit alarming for approx. 9 mi-
nutes. The red LED will flash once every 10 seconds, it indicates the smoke alarm device is running into the
silence mode.
Smoke alarms devices are conceived to minimize nuisance alarms.
The smoke alarm will automatically reset after approximately 9 minutes, if after this period, particles of
combustion are still present, the alarm will sound again.
The alarm silencer (silence mode) can be repeatedly used until the air has been cleared of the conditioning
causing the alarm.
Caution: Before using the alarm silence (hush), identify the source of the smoke and be certain a safe condi-
tion exists.
Danger: If the alarm sounds, and it is not being tested, it means the unit is detecting smoke, THE SOUND
OF THE ALARM REQUIRES YOUR IMMEDIATE ATTENTION AND ACTION.
Fraud alarm/ false alarms
False alarms can be triggered by the following, for example:
Welding and cutting work,
Soldering and other hot work,
Sawing and sanding work,
Dust due to construction or cleaning,
Water vapour, cooking vapours or odours,
Extreme electromagnetic influences,
Temperature fluctuations, which lead to the condensation of the humidity in the smoke detector.
In the event of works in the environment of the installed smoke detector which trigger false alarms (e.g.
renovation), the detector should be temporarily covered or removed. After completion of the work, the origi-
nal functionality of the installed smoke detector must be restored as described in previous sections.
Should the system report an alarm, please check whether the fire really exists. If so, call the fire brigade.
If not, please check whether the mentioned reasons could have raised the alarm. We would like to point out
that we are not liable for the consequences of false alarms. We do not cover any costs incurred by false
alarms, such as for deployment of police, fire or key services.
Maintenance
This includes at least a check of whether the smoke penetration openings are free (e.g. covers, pollution

Ningbo Kingdun Electronic Industry Co.,Ltd.
Page 10 of 10
caused by fluff and dust), whether there is function-related damage to the smoke detector and whether the
area of 0.5m around the smoke detector is free of obstacles (such as furniture), which inhibit the penetra-
tion of fire smoke into the smoke detector. If contamination is detected in the smoke penetration openings,
there should be cleaned according to manufacturer instructions. If there is function-related damage to the
smoke detector, it must be replaced. If the installed smoke detector does not have the required clearance
around it, the mounting location must be inspected and a new location determined if necessary.
WEE-reference of disposal
In accordance with European defaults used electrical and electronics devices may no more be given to the
unsorted waste. The symbol of the waste bin on wheels refers to the necessity of separate collection. Please
help with environmental protection and see to it that this device is given to the for this purpose designated
systems of waste sorting if you do not use it any longer.
Trouble shooting
PROBLEM
ACTION
SOLUTION
Smoke alarm does not
sound when tested
Must activate alarm before
installation
Remove battery pin to ON
Clean smoke alarm.
Refer to “Maintenance”
If there are still failures af-
ter above actions
Return to your retailer
Alarm about every 43S
Battery low voltage
Replace the smoke alarm.
Unwanted alarms intermit-
tently
Press test button to pause
alarm. Clean smoke alarm
Refer to “Maintenance”. Move smoke
alarm to new location and press test
button.
Alarm sounds different
from normal use
Clean smoke alarm
Refer to “Maintenance”
If there are still failures af-
ter above actions
Return to your retailer