Kingsman Marquis IDV26 User manual

WARNING: If the information in these instructions is not followed
exactly, a fire or explosion may result causing property damage,
personal injury or loss of life.
Warning: Improper installation, adjustment, alteration, service or
maintenance can cause property damage, personal injury or loss of
life. Refer to this manual. Installation and service must be performed
by a qualified installer, service agency or the gas supplier.
Do not store or use gasoline or other flammable vapors and liquids
in the vicinity of this or any other appliance.
-What To Do If You Smell Gas
Do not try to light any appliance.
Extinguish any open flame.
Do not touch any electrical switch.
Do not use any phone in your building.
Immediately call your gas supplier from a neighbor’s phone.
Follow the gas supplier’s instructions.
If you can not reach your gas supplier, call the fire department.
Installation and service must be performed by a qualified installer,
service agency or the gas supplier.
WARNING: The
IDV26/IDV33/IDV36 Fireplace Insert
was designed for installation in a
solid fuel fireplace that has been
installed in accordance with
national, provincial/state and local
building codes and is constructed
of noncombustible materials. Do not
remove any refractory materials
from any masonry solid fuel
fireplace.
The IDV26/IDV33/IDV36 Fireplace
Insert was designed for installation in a
zero clearance type listed solid fuel
burning factory built fireplace. It may
be necessary to remove the damper
plate, refractory liners, log grates,
glass door, and screen rails/mesh.
Removal of the smoke baffle is
necessary in most cases.
Installation Instructions
Gas Fired Direct Vent Room Heater Inserts
Listed Certified for USA. and Canada
Model Numbers:
IDV26 –Stock Numbers: IDV26N, IDV26LP, IDV26NE,IDV26LPE
Minimum Fireplace Opening Required: 33”W x 19-1/2”H x 14-1/4”D Components In
28”W x 19-1/2”H x 14-1/4”D Components Out
IDV33 - Stock Numbers: IDV33N, IDV33NE, IDV33LP, IDV33LPE
Minimum Fireplace Opening Required: 26-1/4”W x 21-3/8”H x 14-3/8”D
IDV36 –Stock Numbers: IDV36N, IDV36NE, IDV36LP, IDV36LPE
Minimum Fireplace Opening Required: 30-3/4”W x 25-5/8”H x 14-3/8”D
Are Certified to: ANSI Z21.88-2009, CSA 2.33-2009, CGA 2.17-M91
FOR YOUR SAFETY
Read this complete manual before beginning installation.
These instructions must be kept with the unit for future reference.
This appliance may be installed in an aftermarket permanently located, manufactured home (USA only) or
mobile home, where not prohibited by local codes.
This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not
convertible for use with other gases, unless a certified kit is used.
A Division of R-Co. Inc.
2340 Logan Avenue
Winnipeg, Manitoba, Canada R2R 2V3
Ph: (204) 632-1962
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
Printed in Canada March 14, 2014 Part # 26IDV-MAN

Pre-installation Questions and Answers
About curing of the paint
Your stove or fireplace has been painted with the highest quality silicone stove paint. This paint dries quickly in 15-20
minutes when first applied at the factory. However, due to the high temperature silicone components, the paint will cure
when heat is applied to the appliance as it is first used. The following information applies to the curing process to get the
paint fully hard and durable.
Fire the appliance four successive times for 10 minutes each firing and a 5 minute cool down between each. Be aware
during log and firebox paint curing that a white deposit may be developing on the inside of the glass doors. It is important
to remove this white deposit from the glass doors using a commercial fireplace glass cleaner.
Babies, small children, pregnant women and pets should leave the area during the cure phase.
Ventilate well, open doors and windows.
Do not touch during curing.
Why does my fireplace or stove give off odour?
It is normal for your fireplace to give off some odour. This is due to the curing of the paint, adhesives, silicones and any
undetected oil from the manufacturing process as well as the finishing materials used with the installations (e.g. marble,
tile and the adhesives used to adhere this product to the walls can react with heat and cause odours).
It is recommended that you burn your gas fireplace or stove for a minimum of four hours at a time with the fan off (if a fan
is present) after the curing of the paint has been completed. These odours can last upward to 40 hours of burn time; keep
burning at a minimum of four hours per use until odours dissipate.
Noise coming from the fireplace?
Noise is caused by the expansion and contraction of metal as the appliance heats up and cools down. This is normal and
is similar to the sounds produced by a furnace or heating duct. This noise does not affect the operation or longevity of
your fireplace.
Operating Instructions
1. Be sure to read and understand all the instructions in this manual before operation of appliance.
2. Ensure all wiring is correct and properly enclosed to prevent possible shock.
3. Check for gas leaks.
4. Make sure the glass door is properly installed before operation. Never operate the appliance with the glass door
removed.
5. Make sure venting and termination cap are installed and unobstructed.
6. If brick or porcelain liners are used, ensure they are installed.
7. Verify that the pilot can be seen when lighting the appliance. If not, the log or rock placement is incorrect.
8. If the unit is turned off, you must wait a minimum of 60 seconds before re-lighting it.
9. The pilot should be lit ½ hour before turning on appliance.
10. The pilot should be left on during the heating season.
2

Table of Contents
Pre-installation Questions and Answers............................................................................................................... 2
Operating Instructions........................................................................................................................................... 2
Table of Contents................................................................................................................................................. 3-4
Mobile Home/Manufactured Housing Installation................................................................................................. 5
Warnings, Installations and Operations................................................................................................................ 6
Installation Requirements for the Commonwealth of Massachusetts................................................................... 7
Important Information............................................................................................................................................ 8
IDV26 Insert Dimensions and Sizing.................................................................................................................... 9
I26CV Clean View and Surround Sizes................................................................................................................ 10
I26CV1DS Designer Door................................................................................................................................. 11
I26SU Universal Surround.................................................................................................................................... 12-13
I26CV Surround Installation / Clean View (CV) Attachment / Valve Access....................................................... 14
I26S1 / I26SPF1 / I26SU Surround Installation..................................................................................................... 15
I26CV2 / I26CVPF2 Wide Clean View Installation................................................................................................ 16
I26CV2 / I26CVPF2 Wide Clean View Installation -Components Out-................................................................. 17
IDV33 Insert Dimensions and Sizing.................................................................................................................... 18
I33CV Clean View and Surround Sizes................................................................................................................ 18
I33LK Louver Kit and Surround Sizes................................................................................................................... 19
IDV36 Insert Dimensions and Sizing.................................................................................................................... 20
I36CV Clean View and Surround Sizes................................................................................................................ 20
I36LK Louver Kit and Surround Sizes................................................................................................................... 21
I33CV/I36CV Front Face and Surround Attachment Installation.......................................................................... 22
I33LK/I36LK Front Face Attachment Installation.................................................................................................. 23
Surround Installation for IDV33/IDV36 Fronts....................................................................................................... 24
IDV26 / IDV33 / IDV36 Wall Coverings................................................................................................................. 25
IDV26/IDV33/IDV36 Clearance to Combustible Mantels...................................................................................... 26
Venting.................................................................................................................................................................. 27
Installation of Vent Pipe........................................................................................................................................ 28
Insulation of Chimney Cavity IDV26 / IDV33 / IDV36........................................................................................... 29
IPI (Intermittent Pilot Ignition) Appliances Cold Climate Mode............................................................................. 29
IDV26 / IDV33 / IDV36 Riser Kit and Leveling Instructions.................................................................................. 30
Glass Door Information........................................................................................................................................ 31
IDV26PRL - Porcelain Liner Panels-..................................................................................................................... 32
IDV26RL - Brick Liner Panels-.............................................................................................................................. 33
IDV33 & IDV36 Brick Liners.................................................................................................................................. 34
IDV33/36PL- Liner Panels -Generation 1............................................................................................................. 34
IDV33/36PRL Removing and Installing Generation 2 Liner Panels..................................................................... 35
IDV33 / IDV36 Overlay and Double Door Installation......................................................................................... 36
Gas Line Installation............................................................................................................................................. 37
IDV33 / IDV36 Burner Installation/Removal.......................................................................................................... 38
IDV26 Burner Installation/Removal....................................................................................................................... 38-39
IDV26 -Millivolt- Control Components Outside the Opening- COMPONENTS OUT........................................ 40-41
IDV26 -IPI- Control Components Outside the Opening- COMPONENTS OUT............................................ 41-42
IDV26 Fan Speed Control Outside COMPONENTS OUT.................................................................................... 43
IDV26 Optional Fan Removal / Wiring........................................................................................................... 44-45
IDV33 / IDV36 Fan Installation/Removal.............................................................................................................. 46
IDV33/IDV36 Insert Burner Component List......................................................................................................... 47
3

Millivolt System, Lighting, and Burner Control...................................................................................................... 48
IDV26 Remote Receiver Location........................................................................................................................ 49
IPI Electronic Ignition System............................................................................................................................... 50-52
Electronic Ignition Lighting Instructions................................................................................................................. 53
IDV26 LOGF26…………………………………………………………………………………………………………… 54
IDV26 LOGF27…………………………………………………………………………………………………………… 55
Log Placement – LOGF35.................................................................................................................................... 56
Log Placement – LOGF36.................................................................................................................................... 57
MQRSP4 / MQRSP8 Rock and Glass Support Platform Installation IDV26 / IDV33 / IDV36............................... 58
RSP10 Glass Support Platform -Installation IDV26 / IDV33 / IDV36.................................................................... 59
MQROCK2 / MQROCK3 -MQRSP4 IDV26 / IDV33 / IDV36................................................................................ 60-61
MQStone MQRSP8 IDV26 / IDV33 / IDV36......................................................................................................... 62
Glass Ember / MQ Ember Installation -MQRSP8 / RSP10- IDV26 / IDV33 / IDV36............................................ 63
Burner System Maintenance................................................................................................................................ 64
Conversion Kit Instructions – PART A.................................................................................................................. 65
Gas Conversion for Top Convertible Pilot (Series 019065X) – PART B............................................................... 66
Gas Conversion for Modulator – PART C............................................................................................................. 67
Troubleshooting the Gas Control System............................................................................................................. 68
IDV26 Parts List.................................................................................................................................................... 69
IDV33 Parts List.................................................................................................................................................... 69-70
IDV36 Parts List.................................................................................................................................................... 70
Parts for IDV26/ IDV33/ IDV36............................................................................................................................. 71
Parts for IDV26/ IDV33/ IDV36 Venting................................................................................................................ 71
Limited Lifetime Warranty..................................................................................................................................... 72
4

Mobile Home/Manufactured Housing Installation
This Direct Vent System Appliance must be installed in accordance with the manufacturer’s installation instructions and
the Manufactured Home Construction and Safety Standard Title 24 CFR, Part 3280, or the current Standard for Fire
Safety Criteria for Manufactured Home Installation, Sites, and Communities ANSI/NFPA 501A, and with CAN/CSA Z240
MH Mobile Home Standard in Canada.
THIS APPLIANCE MAY BE INSTALLED IN MANUFACTURED (MOBILE) HOMES AFTER FIRST SALE.
Please follow the current ANSI/NFPA 70 National Electrical Code in the USA and CAN/CSA C22.1 Canadian National
Electrical Code in Canada.
An appliance must be grounded to the steel chassis of the home with 8ga. copper wire using a serrated or star washer to
penetrate paint or protective coating to insure grounding.
Use carriage bolt at the attachment point (see diagram above) to secure the appliance to the floor.
Bedroom approved.
Warning: Do not compromise the structural integrity of the manufactured home wall, floor or ceiling,
during installation of appliance or venting.
For required venting components see venting installation in appropriate section of this manual.
5

Warnings, Installations and Operations
Installation Regulations
This gas appliance must be installed by a qualified installer in accordance with local building codes, or in the absence of local codes, with the current
CAN/CSA-B149.1 or .2 Installation Code (in Canada) or the current National Fuel Gas Code Z223.1- NFPA 54 when installed in the United States.
This appliance, when installed, must be electrically connected and grounded in accordance with local codes, or in the absence of local codes, with the
current CSA C22.1 Canadian Electrical Code or with the National Electrical Code; ANSI/NFPA 70 when installed in the United States.
In the U.S.A. Thermostats are not permitted for Vented Gas Fireplaces (ANSI Z21.50b-Decorative).
WARNING
FOR SAFE INSTALLATION AND OPERATION OF YOUR GAS FIREPLACE PLEASE NOTE THE FOLLOWING:
1. Do not clean when the glass is hot.
2. Do not use abrasive cleaners.
3. Using a substitute glass will void all product
warranties.
4. For safe operation, glass doors must be
closed.
5. When purging the gas line, the glass front
must be removed.
6. Do not strike or abuse glass. Take care to
avoid breakage.
7. Do not alter gas orifice.
8. No substitute materials may be used other
than factory supplied components.
9. This appliance gives off high temperatures and should be located out of heavy traffic areas and away from furniture and
draperies.
10. Children and adults should be alerted to the hazards of the high surface temperatures of this appliance and should stay
away to avoid burns or ignition of clothing.
11. Young children should be carefully supervised when they are in the same room as the appliance. Toddlers, young children
and others may be susceptible to accidental contact burns. A physical barrier is recommended if there are at risk individuals
in the house. To restrict access to a fireplace or stove, install an adjustable safety gate to keep toddlers, young children and
other at risk individuals out of the room and away from hot surfaces.
12. Under no circumstances should any solid fuels (wood, paper) be used in this appliance.
13. Under no circumstances should this appliance be modified. Any parts that have to be removed for servicing should be
replaced prior to operating this appliance.
14. Any safety screen or guard removed for servicing an appliance must be replaced prior to operating the appliance.
15. Installation and repair should be done by a qualified service person. The appliance should be inspected before use and at
least annually by a professional service person. More frequent cleaning may be required due to excessive lint from
carpeting, bedding material, et cetera. It is imperative that control compartments, burners and circulating air passageways of
the appliance be kept clean. Make sure that the gas valve and pilot light are turned off before you attempt to clean this unit.
16. Clothing or other flammable material should not be placed on or near the appliance. This appliance should not be used as a
drying rack for clothing nor should Christmas stockings or decorations be hung from it.
17. Do not use this heater if any part has been under water. Immediately call a qualified service technician to inspect the heater
and to replace any part of the control system and any gas control which has been under water.
18. Do not operate appliance unless completely installed as per installation instructions.
19. Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this
appliance may result in property damage or personal injury.
20. Do not operate appliance with the glass front removed, cracked or broken. Replacement of the glass should be done by a
licensed or qualified service person.
21. The front of the fireplace gives off high temperatures that could ignite combustible material which is kept close to the front of
the unit.
22. Ensure that power to the Fireplace is turned off before servicing.
23. Do not operate this Fireplace without the glass front or with a broken glass.
24. Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to the
owner’s information manual provided with this appliance. For assistance or additional information consult a qualified
installer, service agency, or the gas supplier.
25. Operation of this appliance when not connected to a properly installed and maintained venting system or tampering with the
blocked vent shutoff system can result in carbon monoxide (CO) poisoning and possible death.
26. This appliance is equipped with a three-prong (grounding) plug for your protection against shock hazard and should be
plugged directly into a properly grounded three-prong receptacle. Do not cut or remove the grounding prong from this plug.
WARNING
HOT GLASS WILL
CAUSE BURNS
DO NOT TOUCH GLASS
UNTIL COOLED.
NEVER ALLOW CHILDREN
TO TOUCH GLASS.
6

• Gas fired appliances may be used only for supplemental heat and/or decorative purposes and under no circumstances shall they
provide a primary heat source.
• This appliance must not be connected to a chimney flue serving a separate solid-fuel burning appliance.
NOTE: It is recommended that a Carbon Monoxide (CO) Detector be installed in or near bedrooms and on all levels of your home.
Place a detector about 15ft [4.5m] outside the room that houses your gas appliance.
Certified for installation in a bedroom or bed/sitting room. In Canada must be installed with listed millivolt thermostat.
In the U.S.A. Thermostats are not permitted for Vented Gas Fireplaces (ANSI Z21.50b-Decorative).
In USA see local codes.
Operations and Maintenance Instructions
For safe installation and operation note the following:
• Venting systems should be periodically examined by a qualified agency.
• The flow of combustion and ventilation air must not be obstructed.
• The Burner/Log Assembly has been engineered and permanently adjusted for proper flame control.
• Periodically remove the logs from the grate assembly and vacuum any loose particles from the grate and burner areas. See Log
Placement page to remove logs. Vacuum burner parts and replace logs.
• Never use your gas fireplace as a cooking device.
• Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify
proper operation after servicing.
Installation Requirements for the Commonwealth of
Massachusetts
In the Commonwealth of Massachusetts, the installer or service agent shall be a plumber or gas fitter licensed by the Commonwealth.
When installed in the Commonwealth of Massachusetts or where applicable codes; the unit shall be installed with a CO detector per the
requirements listed below.
1. For direct-vent appliances, mechanical-vent heating appliances or domestic hot water equipment, where the bottom of the vent
terminal and the air intake is installed below four feet above grade the following requirements must be satisfied:
A. If there is not one already present, on each floor level where there are bedroom(s), a carbon monoxide detector and alarm
shall be placed in the living area outside the bedroom(s). The carbon monoxide detector shall comply with NFPA 720.
B. A carbon monoxide detector shall be located in the room that houses the appliance or equipment and shall:
• Be powered by the same electrical circuit as the appliance or equipment such that only one service switch services
both the appliance and the carbon monoxide detector;
• Have battery back-up power;
• Meet ANSI./UL 2034 Standards and comply with NFPA 720; and
• Have been approved and listed by a Nationally Recognized Testing Laboratory as recognized under 527 CMR.
C. A Product-approved vent terminal must be used, and if applicable, a Product-approved air intake must be used.
Installation shall be in strict compliance with the manufacturer’s instructions. A copy of the installation instructions shall
remain with the appliance or equipment at the completion of the installation.
D. A metal or plastic identification plate shall be mounted at the exterior of the building, four feet directly above the location of
vent terminal. The plate shall be of sufficient size to be easily read from a distance of eight feet away, and read “Gas Vent
Directly Below”.
2. For direct-vent appliances, mechanical-vent heating appliances or domestic hot water equipment where the bottom of the vent
terminal and the air intake is installed above four feet above grade the following requirements must be satisfied:
A. If there is not one already present, on each floor level where there are bedroom(s), a carbon monoxide detector and alarm
shall be placed in the living area outside the bedroom(s). The carbon monoxide detector shall comply with NFPA 720.
B. A carbon monoxide detector shall:
• Be located in the room that houses the appliance or equipment;
• Be either hard-wired or battery powered or both; and
• Shall comply with NFPA 720.
A Product-approved vent terminal must be used, and if applicable, a Product-approved air intake must be used. Installation shall be in
strict compliance with the manufacturer instructions. A copy of the installation instructions shall remain with the appliance or equipment
at the completion of the installation.
For the state of Massachusetts a T-handle gas shut-off valve must be used on a gas appliance. This T-handle gas shut-off valve must be listed and
approved by the state of Massachusetts. This is in reference to the state of Massachusetts state code CMR238.
7

Important Information
INSTALLATIONS
The following label (supplied with the gas fireplace insert) must be attached with rivets or screws to the inside of the
firebox of the fireplace into which it is installed:
Cutting any sheet-metal parts of the fireplace, in which the gas fireplace insert is to be installed, is prohibited.
If the factory-built fireplace has no gas access hole(s) provided, an access hole of 1.5 in (37.5 mm) or less may be drilled
through the lower sides or bottom of the firebox in a proper workmanship like manner. This access hole must be plugged
with non-combustible insulation after the gas supply line has been installed.
The fireplace flue damper can be fully blocked open or removed for installation of the gas fireplace insert.
Ensure that existing chimney cleanouts fit properly.
refractory, glass doors, screen rails, screen mesh and log grates can be removed from the fireplace before installing the
gas fireplace insert.
Smoke shelves, shields and baffles may be removed if attached by mechanical fasteners.
Trim panels or surrounds must not seal ventilation openings in the fireplace.
The fireplace and fireplace chimney must be clean and in good working order and constructed of non-combustible
materials.
MAINTENANCE
If for any reason the vent air intake system is disassembled, re-install and re-seal per the instructions provided for the
initial installation. See “Installation of Vent Pipe” section.
It is recommended to annually inspect and clean the Burner System to prevent malfunction and / or sooting. This
operation should be performed by your dealer or a qualified technician. Refer to Burner System Maintenance section.
Venting systems should be periodically examined by a qualified agency.
Periodically remove the logs from the grate assembly and vacuum any loose particles from the grate and burner areas.
See Log Placement page to remove logs. Vacuum burner parts and replace logs.
8

IDV26 Insert Dimensions and Sizing
Top View- Components In
(As Shipped)
Minimum Opening Dimensions
Dimension Components In Components
Out
“A” Front Width: 33” Centered in existing fireplace
*31” Not Centered in existing fireplace 28”
“B” Height: 19-1/2” 19-1/2”
“C” Depth: 14-1/4” 14-1/4”
“D” Back Width: 22” 22”
Note: Valve Control Components can be placed either inside the opening
(Components In) or outside the opening (Components Out).
Units are shipped with Control Components in.
For instructions on changing to Components Out refer to Control Components
Outside the Opening- COMPONENTS OUT.
“C”
“A”
“B”
Base Model
Components In
Components Out
Front View
Left Side View
Top View- Components In
With I26CV1
Top View- Components Out
“D”
30-7/8”*
30-7/8”*
Top View- Components Out
With I26CV2
9

I26CV Clean View and Surround Sizes
*The Clean Views and Surrounds in this section must be used with Valve Control Components inside the opening (as shipped).
*The Clean Views in this section can be used with Valve Control Components inside or outside the opening, HOWEVER-
if controls are outside, these Clean Views MUST be used to cover valve controls.
Clean View Kit I26CV1 Picture Frame Clean View Kit
I26CVPF1
Clean View Kit with
Rectangular Surround I26S1 Picture Frame Clean View Kit with
Picture Frame Surround I26SPF1
Clean View Kit I26CV2 Picture Frame Clean View Kit
I26CVPF2
10

I26CV1DS IDV26
*The Clean View Designer Door and optional surround in this section must be used with Valve Control Components inside the opening
(as shipped).
I26CV1DS
I26CV1DS with
Rectangular Surround I26S1
11

IDV26 I26SU Universal Surround
A Universal Surround is available for the IDV26. This is provided as a flat sheet which mounts onto the unit and is to be
cut to size and formed by the installer. Flat Surround Shown dimensioned.
I26SU installed on unit.
Refer to Worksheet on next page to trim for use as a 3-sided surround or for a custom layout.
Com
p
onents In
Com
p
onents Out
Picture Frame Clean View Kit I26CVPF1
With Universal Surround I26SU Picture Frame Clean View Kit I26CVPF2
With Universal Surround I26SU
I26SU must be trimmed to fit around
Valve Control Components.
7”
12

I26SU UNIVERSAL SURROUND
I26CVPF I26CVPF2
BOTTOM OF UNIT
13

I26CV - Surround Installation
-Clean View (CV) Attachment
-Valve Access
1. Optional Surround Kit (I26S, I26SPF, I26SU) is fastened to the insert by pulling up [4] Surround Mount Tabs on the
unit and using [4] #6 screws provided with surround.
2. Insert the Clean View (I26CV1, I26CV2, I26CVPF1, I26CVPF2, I26CV1DS) Mounting Tab into the Clean View
Mounting Slots (four [4] places) and lower the Clean View kit into place.
3. Valve Access: To access valve simply remove Clean View. Replace Clean View as per item [2] above once
adjustments to valve have been completed.
NOTE: The Clean View Surround needs to be removed in order to access the Glass Door, access the valve, and
service the unit.
Valve positioned as per manufacturer’s instructions.
Surround Mount Tab
Surround Mount Tab
Clean View Mount Tab
Clean View Mount Slot
Clean View Kit
Optional Surround
Insert Tab into
Slot to mount the
Clean View Kit.
14

I26S1 / I26SPF1 / I26SU Surround Installation
Component List: I26S1 / I26SPF1 / I26SU Surround, [Qty 4] #6 Black Combo Screws
Bend Up All 4 Mount Tabs
Top Left
Top Right
Bottom Left
Bottom Right
Place Surround onto unit and
line up holes in mount tabs with
holes in Surround. Attach with
screws provided.
15

I26CV2 / I26CVPF2 Wide Clean View Installation
Component List:
I26CV2 or I26CVPF2 Clean View
On/ Off Switch Extension Bracket
Fan Control Switch Extension Bracket
[4] #6 Black Combo Screws
Components In (As Shipped):
Fan Control Switch Bracket On/Off Switch Bracket
Remove Fan Control Switch From Current Position.
Remove On/Off Switch and original mount bracket.
Attach Fan Control Switch Extension Bracket using [2] #6
Combo Screws as shown.
Attach On/ Off Switch Extension Bracket using [2] #6
Combo Screws as shown.
Mount Switch & route wiring as shown.
Mount Switch & route wiring as shown.
Insert Mount Tabs into slots in unit and lower Clean View into place. Refer to Clean View Attachment.
16

I26CV2 / I26CVPF2 Wide Clean View Installation -Components Out-
Fan Control Switch Bracket On/Off Switch Bracket
Remove On/Off Switch and original mount bracket.
NOTE: If Ground is attached to Side Component Plate,
remove and fasten to side of appliance with a DT Screw.
Remove Fan Control Switch From Current Position.
Attach Fan Control Switch Extension Bracket using [2] #6
Combo Screws.
Mount Switch & route wiring as shown.
Attach On/ Off Switch Extension Bracket using [2] #6
Combo Screws as shown.
Mount Switch & route wiring as shown.
Insert Mount Tabs into slots in unit and lower Clean View into place. Refer to Clean View Attachment.
17

IDV33 Insert Dimensions and Sizing
I33CV Clean View and Surround Sizes
Min. Coverage with Optional I33LK or I33CV
Base Unit I33LK I33CV
Front Width: 26-1/4” 34-1/2” 32-3/4”
Rear Width: 21-1/4” 21-1/4” 21-1/4”
Height: 21-3/8” 24-3/8” 22-3/4”
*Depth: 14-3/8” 18-3/8” 16-3/4”
Unit Sits Proud of Finished Surface 2-1/2” with
CV Kit, and 4” with LK Kit.
18

I33LK Louver Kit and Surround Sizes
NOTE: The Surrounds shown here are universal and can be used with the I33CV model. Furthermore, the
I33S4535B and I36S4736B (1-piece Surround) was designed to be used as a custom cutout surround. Simply
trace template and cut out design using the universal surround.
19

IDV36 Insert Dimensions and Sizing
I36CV Clean View and Surround Sizes
Min. Coverage with Optional I36LK or I36CV
Base Unit I36LK I36CV
Front Width: 30-3/4” 39” 37-1/4”
Rear Width: 25-3/4” 25-3/4” 25-3/4”
Height: 25-5/8” 28-3/4” 27”
Depth: 14-3/8” 18-3/8” 16-3/4”
Unit Sits Proud of Finished Surface 2-1/2” with CV
Kit, and 4” with LK Kit.
20