A. Weather Seal B. Screws C. Watchman Sonic Advanced Transmitter D. Watchman Sonic Advanced Base Parts B
and D are not needed if unit is supplied with EcoSafe tank. E. Waveguide Adapter for optional waveguide installation
A B C
D
Check level,
distance
and height
Drill
Tank
Apply
Base
Measure
Tank
Fit
transmitter
to the
base
This product is to be used only on tanks within the parameters outlined in the specications.
Any use of the product on applications that lie outside these specications is done so at users own risk.
E

Where drilling is required to t the transmitter, choose a at level
point that is at the same level and no lower than any opening at
the top of the tank (lling point etc.) (See Picture 3)
The Transmitter can’t sit at an angle as this gives an incorrect
level reading on the receiver. Take care not to choose an area
on which water could gather i.e. a dent/depression or a position
directly above any restricted area inside the tank. (See Picture 4)
Pic 3
Pic 4
Choose a suitable position for transmitter
Outlet
Outlet
Pic 2
it is important to keep all items dry during installation.
There may already be a 32mm pre-drilled opening in the tank top and possibly
a tube tted. If so, remove the cover by undoing the two screws holding it in place, and
dispose of the tube in accordance with local government guidelines.
There may already be a 2” threaded hole with a red cap screwed in to it If so
remove the red cap and disregard.
Ensure that the space beneath the Watchman Sonic unit is free of any obstacles and
2. TANK PREPARATION Sonic Advanced Transmitter
30cm
1. CHECK LEVEL, DISTANCE AND HEIGHT
Ensure before you start your install that the tank the Watchman Sonic
Advanced is to be tted:
On a at level base.
Within a 200 metre range from receiver position.
A maximum actual tank height of 3 metres.
50 metre eective range (200 metre clear line of sight).
Tank must be tted in accordance with manufacturers
guidelines & instructions.
Any radio frequency signal may be seriously inhibited if positioned
underground. Please check that the transmitter / receiver link works in the
desired location before installation.
Advanced Tank Transmitter Installation Manual

Pic 5
For tanks with window corrugations or internal braces ensure
that the Watchman Sonic Advanced is not positioned above or
within 15cm of the area of the WINDOW or the edge of the tank.
If the Watchman Sonic Advanced is positioned over or close to the
WINDOWED area it transmits incorrect readings to the receiver.
When installed incorrectly on some windowed
tanks the unit can experience false alarms as the oil level drops. It is
important to ensure that the unit is positioned so that the ultrasonic
beam has a 30cm diameter clear area to the bottom of the tank.
Positioning the unit too close to the tank wall or near a tank window
may cause false alarms.
30cm
Sonic
Transmitter
30cm
Sonic
Transmitter
30cm
Sonic
Transmitter
Tank Braces
Tank Windows
1
3
5
Drill a hole in the place that you have selected on the tank’s top
surface using a 32mm hole-saw.
If you are unsure if you should drill the tank please check
with the tank manufacturer rst.
• Remove cap from the hole (Picture 7) and insert
transmitter base, ensuring the weather seal is securely
in place
• Tighten the Watchman Sonic Advanced base on to
the tank with 2 stainless steel self-tapping, counter sunkscrews
supplied Do not over tighten!
3. FITTING TRANSMITTER BASE (ONLY IF SUPPLIED)
Pic 7 Pic 8 Pic 9
Accurately measure the height of your tank making note
of this measurement. The permissible maximum tank
height is 3 metres from the base of your tank to the position
of the Watchman Sonic Advanced (which should be no lower
than the ll point).
• Height does not include the base/piers which tank sits on.
4. DEFINE THE SONIC HEIGHT
Single Skin Oil Tank
Inner
Tank
Outer
Tank
Bunded Oil Tank
Pic
For tanks with pre-drilled holes. Ensure guidelines from point 4 is adhered to.
V.1 EN

30cm
Sonic
Transmitter
30cm
Sonic
Transmitter
30cm
Sonic
Transmitter
Pic
Pic
5. WAVEGUIDE PIPE INSTALLATION (OPTIONAL)
• Choose a at level point that is at the same
level and no higher than any opening at the
top of the tank (lling point etc)
• Only drill the tank where permissible
(Please consult the tank manufacturer
before drilling the tank)
• Ensure that the unit is tted to the inner tank
if it is a bunded tank
• The unit can’t sit at an angle as this gives an
incorrect level. Take care not to choose an
area on which water could gather i.e. dent/
depression or a position directly above any
restricted area inside the tank.
• For tanks with window corrugations please
ensure that the transmitter is not positioned
above of the window.
Pic
Outer Tank
(Bund)
Choose a suitable
position for transmitter Outer Tank
Outlet Inner Tank
Inner Tank
Sonic
Outer Tank
(Bund)
Inner Tank
Outer Tank
(Bund)
Inner Tank
Tank Braces
Tank Windows

1
3
5
Drill a hole in the place that you have selected on
the tank’s top surface using a 58mm hole-saw.
If you are unsure if you should drill the
tank please check with the tank manufacturer
rst.
• Measure height from bottom of the tank to
the top of transmitter base
• Cut the pipe (maximum length of pipe 3m)
To obtain pipe length take 40mm o the
height from bottom of the tank to the top
of unit base
• Pipe type: ABS 32mm Waste Pipe, available
in your local DIY store
• Insert the pre-cut pipe to the pipe adapter
and screw the grub screws.
• Screw base to pre-drilled hole in the tank and
t the unit.
• Ensure the unit is positioned vertical on top
of the tank and level. Ensure that the unit is
screwed correctly into the base and that the
threads have not crossed, to give a good seal
Pic
Pic
Pic Pic
Pic Pic

Pipe Type:
ABS 32mm Waste Pipe,
(available in your local DIY store)
The actual size of pipe is approximately
36.3mm Outer Diameter x 31.8mm Inner Diameter
Pipe
lenght
40mm clearance

GUARANTEETECHNICAL INFORMATION
The Watchman Sonic Advanced is suitable for use in tanks for the
storage of diesel, water, fuel, kerosene, and gas oil types A2, C1, C2
and D as dened by BS 2869. Check with the manufacturer and/or
supplier before using with any other uids.
Units under warranty Warranty will
be void if unit is opened within the warranty period.
Though the lithium battery will have a very long service life, it
will eventually become exhausted and will need replacing. We
recommend using Varta CR2430.
• Remove transmitter from tank
• Take transmitter indoors, into a clean dry environment
• Using a cross point screwdriver, undo the four screws,
located under the main body of transmitter
• Remove the top cover
• Flip out battery
• Clip in new battery
• Re-t cover
• Evenly tighten all four screws - do not over tighten
• Replace transmitter on the tank
• Clip in new battery
• Re-t cover
• Evenly tighten all four screws - do not over tighten
• Replace transmitter on the tank
The Watchman Advanced has a warranty period of 1 year. For each
product accepted by Kingspan Water & Energy as warrantable,
Kingspan Water & Energy will rework or replace the product and
return to the customer at Kingspan Water & Energy expense. The
warranty becomes invalid if the sealed unit is opened
Kingspan Water & Energy
• Used outside the functional and Water & Energy conditions for
which they were designed.
• Physically abused, incorrectly handled/ installed or damaged
in transit.
• Purchased over 1 year ago. (Proof of purchase will be required).
• Returned to Kingspan Water & Energy in a form other than in
which they were originally supplied.
• Subjects to “Act of God”, e.g.: lightning strike, ood or any other
catastrophic event beyond Kingspan Water & Energy’s control.
Any sensor product deemed damaged by the customer shall be
returned to Kingspan Water & Energy’s facility at the customer’s
expense. Kingspan Water & Energy shall not be liable for any costs in
relation to the returned products.
The purchase invoice and a description issue should be joined with
the faulty product. The product should be returned at your shop or
directly at the following address:
Each faulty product must receive Kingspan Water & Energy’s
After-Sale-Service approval before being returned.
distance
SPECIFICATIONS
Minimum depth: 0.5m.
Maximum depth: 3m.
200m in normal “line of sight” conditions.
The eective range of this product can be
inuenced by external sources that may reduce
the range of the transmitter or sensitivity of
the receiver.
Transmitter: 3-voltlithium cell.
Up to 3 years (dependant on tank height).
433 MHz. FM transmission. EN 300-220.
Transmitter: 70x93mm.
Operating temp. Range -10º to +60 º C.
Operating humidity: 0-100%. Sealed airtight
unit made from PP3317 UV stabilized.
32mm
2” BSP external thread adaptor
Supplied by Kingspan Water & Energy Ltd
180 Gilford Road, Portadown, Co. Armagh, Northern Ireland
Do not replace in a potentially explosive atmosphere
Periodically check that the unit is intact and securely fastened to
the tank.
Check with the manufacturer on the chemical compatibility prior
to use.
Do not attempt to repair this equipment. It must be returned to
the manufacturer for repair.
Warning! Electrostatic hazard! Clean only with damp cloth.
Use only VARTA CR2430 batteries.
Not suitable for pressurised containers.
Use on tanks vented to atmosphere.
this apparatus is designed to: Not give rise to
physical injury or other harm due to contact. Not to produce
excessive surface temperatures, infrared, electromagnetic, ionising
radiation. To have no non-electrical dangers. When used in
accordance with these user and installation instructions.
If the equipment is likely to come in to contact with
aggressive substances, then it is the responsibility of the user to take
suitable precautions that prevent it from being adversely aected,
thus ensuring that the type of protection is not compromised.
Aggressive substances; - e.g. liquids or gases that may attack
metals, or solvents that may aect polymeric materials.

DISCLAIMER: The Watchman Alarm acts as a warning for the householder and is
intended as a deterrent for any potential thief. However, it cannot prevent theft
or leakage and householders should take all reasonable steps to ensure the tank is
secured. Kingspan Water & Energy Limited accepts no liability for any fuel losses.
Guarantee Period: 1 Year
5 013573 876212
180 Gilford Road, Portadown,
Co. Armagh, N. Ireland BT63 5LF.
T: +44 (0) 28 3836 4415
kingspan.com
SENSiT®
Advanced Tank Transmitter
Installation Manual
Other manuals for SENSiT
2
Table of contents
Other Kingspan Transmitter manuals
Popular Transmitter manuals by other brands

Harris
Harris Platinum HT EL 2000LS Technical manual

Alf
Alf FDAT-TX user manual

Inovonics
Inovonics EchoStream EN1215EOL installation instructions

Sony
Sony WRT-805A operating instructions

UFM
UFM Katronic KATflow 100 operating instructions

Emerson
Emerson Rosemount Analytical Oxymitter 4000 instruction manual