Klark Teknik DN9680 User manual

DOC02-DN9680UM Issue B
DN9680
8-port AES50 Extender
User Manual

2DN9680
Contents
1. Introduction ................................................................................................4
1.1 Key features ..........................................................................................................................4
1.2 About this manual................................................................................................................4
2. Getting Started ...........................................................................................5
2.1 Unpacking.............................................................................................................................5
2.2 Installation............................................................................................................................5
2.3 Connecting up ......................................................................................................................5
2.4 Powering the unit on/o......................................................................................................5
2.5 Conguration........................................................................................................................5
3. Front panel ..................................................................................................6
4. Rear panel....................................................................................................6
5. Connections.................................................................................................7
6. Conguring The DN9680 ...........................................................................8
7. About The LCD Display...............................................................................8
8. Technical Specications .............................................................................9
9. Service Information ....................................................................................9
9.1 Routine maintenance...........................................................................................................9
9.2 Cleaning the unit ..................................................................................................................9
9.3 Cleaning the optical connectors .........................................................................................9
9.4 Replacing the mains fuse.....................................................................................................9
9.5 Equipment disposal .............................................................................................................9

3User Manual
Important Safety
Instructions
EN
CAUTION
ATTENTION
RISK OF ELECTRIC SHOCK!
DO NOT OPEN!
RISQUE D’ÉLECTROCUTION !
NE PAS OUVRIR !
Terminals marked with this symbol
carry electrical current of sucient
magnitude to constitute risk of electric
shock.
Use only high-quality commercially-available speaker
cables with ¼”TS plugs pre-installed. All other
installation or modication should be performed only
by qualied personnel.
This symbol, wherever it appears,
alerts you to the presence of
uninsulated dangerous voltage inside
the enclosure - voltage that may be
sucient to constitute a risk of shock.
This symbol, wherever it appears,
alerts you to important operating and
maintenance instructions in the
accompanying literature. Please read
the manual.
Caution
To reduce the risk of electric shock, do
not remove the top cover (or the rear
section). No user serviceable parts
inside. Refer servicing to qualied personnel.
Caution
To reduce the risk of re or electric
shock, do not expose this appliance to
rain and moisture. The apparatus shall
not be exposed to dripping or splashing liquids and
no objects lled with liquids, such as vases, shall be
placed on the apparatus.
Caution
These service instructions are for use
by qualied service personnel only.
To reduce the risk of electric shock do
not perform any servicing other than that contained
in the operation instructions. Repairs have to be
performed by qualied service personnel.
1. Read these instructions.
2. Keep these instructions.
3. Heed all warnings.
4. Follow all instructions.
5. Do not use this apparatus near water.
6. Clean only with dry cloth.
7. Do not block any ventilation openings. Install in
accordance with the manufacturer’s instructions.
8. Do not install near any heat sources such as
radiators, heat registers, stoves, or other apparatus
(including ampliers) that produce heat.
9. Do not defeat the safety purpose of the polarized
or grounding-type plug. A polarized plug has two
blades with one wider than the other. A grounding-
type plug has two blades and a third grounding prong.
The wide blade or the third prong are provided for
your safety. If the provided plug does not t into your
outlet, consult an electrician for replacement of the
obsolete outlet.
10. Protect the power cord from being walked on or
pinched particularly at plugs, convenience receptacles,
and the point where they exit from the apparatus.
11. Use only attachments/accessories specied by the
manufacturer.
12. Use only with the
cart, stand, tripod, bracket,
or table specied by the
manufacturer, or sold with
the apparatus. When a cart
is used, use caution when
moving the cart/apparatus
combination to avoid injury from tip-over.
13. Unplug this apparatus during lightning storms or
when unused for long periods of time.
14. Refer all servicing to qualied service personnel.
Servicing is required when the apparatus has been
damaged in any way, such as power supply cord or
plug is damaged, liquid has been spilled or objects
have fallen into the apparatus, the apparatus has
been exposed to rain or moisture, does not operate
normally, or has been dropped.
15. The apparatus shall be connected to a MAINS
socket outlet with a protective earthing connection.
16. Where the MAINS plug or an appliance coupler is
used as the disconnect device, the disconnect device
shall remain readily operable.
LEGAL DISCLAIMER
TECHNICAL SPECIFICATIONS AND APPEARANCES ARE
SUBJECT TO CHANGEWITHOUT NOTICE AND ACCURACY
IS NOT GUARANTEED. MIDAS AND KLARK TEKNIK ARE
PART OF THE MUSIC GROUP (MUSIC-GROUP.COM).
ALL TRADEMARKS ARE THE PROPERT Y OF THEIR
RESPECTIVE OWNERS. MUSIC GROUP ACCEPTS NO
LIABILIT Y FOR ANY LOSSWHICH MAY BE SUFFERED
BY ANY PERSONWHO RELIES EITHER WHOLLY OR
IN PART UPON ANY DESCRIPTION, PHOTOGRAPH
OR STATEMENT CONTAINED HEREIN. COLOURS AND
SPECIFICATIONS MAYVARY SLIGHTLY FROM PRODUCT.
MIDAS PRODUCTS ARE SOLDTHROUGH AUTHORIZED
DEALERS ONLY. DISTRIBUTORS AND DEALERS ARE NOT
AGENTS OF MUSIC GROUP AND HAVE ABSOLUTELY NO
AUTHORITY TO BIND MUSIC GROUP BY ANY EXPRESS
OR IMPLIED UNDERTAKING OR REPRESENTATION. THIS
MANUAL IS COPYRIGHTED. NO PART OF THIS MANUAL
MAY BE REPRODUCED OR TRANSMITTED IN ANY FORM
OR BY ANY MEANS, ELECTRONIC OR MECHANICAL,
INCLUDING PHOTOCOPYING AND RECORDING OF ANY
KIND, FOR ANY PURPOSE,WITHOUT THE EXPRESS
WRITTEN PERMISSION OF MUSIC GROUP IP LIMITED.
ALL RIGHTS RESERVED.
© 2013 MUSIC Group IP Ltd.
Trident Chambers, Wickhams Cay, P.O. Box 146, Road
Town, Tortola, British Virgin Islands
LIMITED WARRANTY
For the applicable warranty terms and conditions
and additional information regarding MUSICGroup’s
LimitedWarranty, please see complete details online
at www.music-group.com/warranty.

4DN9680
DN9680 8-port AES50 Extender
1. Introduction
Welcome!
Thank you for purchasing a KLARK TEKNIK DN9680 8-port AES50 Extender.
The DN9680 is an 8-port AES50 extender designed to take up to eight AES50
connections, convert them to HyperMAC for transport over distances of up to one
kilometre and then convert them back to AES50 on a port-for-port basis.
The DN9680, which is housed in a 1U, 19" rack mount unit, transports up to
192 digital audio signals at 96kHz, bi-directionally over distances of up to 1km
on a single mode 1300nm laser. The unit includes simple port-to-port routing
and optional internal clock generation. The AES50 input format is suitable for
products in the Midas digital console range and future AES50-enabled Behringer
digital consoles.
Two DN9680s are required in a typical system set-up, each one being congured
via a simple utility that is based on hypertext transfer protocol (http) and
accessed through an Ethernet control port.
The DN9680 was conceived by KLARK TEKNIK to oer audio professionals high
performance audio equipment, designed to provide no-compromise sonic
quality with a feature set that oers all essential facilities and functions. It
represents the very best of British design and engineering combined with
contemporary, ecient manufacturing methods, and will give you many years of
reliableservice.
So, to obtain the best results with a minimum of eort, please read this manual
and, nally, enjoy your KLARK TEKNIK DN9680 8-port AES50 Extender!
1.1 Key features
The DN9680 has the following key features:
• 8 x AES50 etherCON® input ports.
• Each AES50 port carries 24 channels of 96kHz digital audio plus control data.
• AES50 is converted to HyperMAC for transport over a snake to another
DN9680, which converts signals back to AES50 on port-for-port basis.
• Option of optical bre (up to 1km) or copper snake (up to 100m) via an
opticalCON® port or etherCON port, respectively.
• Ethernet control port for unit conguration (IP address, sample rate, clock
options, etc.) via on-board web-based application.
• LCD display.
• Unit is transparent when connected to console (cannot be detected), so that
any device connected at an AES50 port will have its signalling information
(port info., redundancy info., diagnostics, discovery, etc.) mirrored at the
other DN9680.
• 96kHz sample rate.
• Three clock options: internal; external AES50; and external snake.
• Mains input is a switch mode power supply (SMPS) with on/o switch and
fuse drawer for easy fuse replacement.
• Internal fan.
• Reset button for resetting the unit to its factory default condition.
1.2 About this manual
This is the user manual for the DN9680 8-port AES50 Extender. It is intended to
help get your unit installed and in operation as quickly as possible by giving you
unpacking, installation, connection, setting up and operating instructions. To
help familiarise you with the DN9680 there is a description of the front and rear
panels and maintenance instructions to ensure your DN9680 gives you optimum
performance.

5User Manual
2. Getting Started
This section shows you how to unpack, install, connect up, power up and
congure the DN9680 unit.
◊ This equipment is supplied by a mains voltage that can cause electric shock
injury.
◊ This equipment is supplied with a bre optic connection system. Beware of
laser radiation. Do not stare into the beam!
◊ Before installing, setting up or operating this equipment, make sure that you
have read and fully understand all of this section and the “Important safety
instructions” at the front of this manual.
2.1 Unpacking
Carefully unpack your DN9680 equipment package.
Then, inspect the DN9680 unit carefully for any signs of damage that may have
occurred during transit and notify the courier immediately if you discover any.
Check the contents of your DN9680 equipment package. If there are any parts
missing, incorrect or faulty, please contact your local distributor or Midas at the
address at the front of this manual.
Please retain the original packing in case you should need to return the
equipment to the manufacturer or supplier, or transport or ship the unit later.
2.2 Installation
Before installing and operating this equipment, make sure it is correctly
connected to the protective earth conductor of the mains voltage supply socket
outlet through the mains lead.
Do not install the equipment in places of poor ventilation.
Do not install this equipment in a location subjected to excessive heat,
dustormechanical vibration. Allow for adequate ventilation around
the equipment, making sure that its fans and vents are not obstructed.
Wheneverpossible, keepthe equipment out of direct sunlight.
Mount in rack only.
Power
◊ The supply cord must be unplugged to ensure complete de-energisation of
the unit.
The internal power supply is of the switch mode type that automatically senses
the incoming mains voltage and will work where the nominal voltage is in the
range 110V AC to 230V AC.
A mains inlet is provided on the rear panel. The correct lead for connection in
the area to which the unit was shipped is supplied with the unit. The equipment
should only be plugged into the mains outlet using the supplied lead.
Handling the equipment
When lifting or moving the equipment, always take its size and weight into
consideration.
Completely isolate the equipment electrically and disconnect all cables from the
equipment before moving it.
Do not insert your ngers or hands in any gaps or openings on the equipment,
forexample, vents.
Electric elds
In accordance with Part 15 of the FCC Rules & Regulations, “… changes or
modications not expressly approved by the party responsible for compliance
could void the user's authority to operate the equipment.”
Should this product be used in an electromagnetic eld that is amplitude
modulated by an audio frequency signal (20 Hz to 20 kHz), the signal to
noise ratio may be degraded. Degradation of up to 60dB at a frequency
correspondingto the modulation signal may be experienced under extreme
conditions (3V/m,90% modulation).
2.3 Connecting up
Connect up the units as required:
• AES50 cables from AES50-equipped device (for example, console) to rst
DN9680.
• Optical/copper snake from rst DN9680 to second DN9680.
• AES50 from second DN9680 to other AES50-equipped device (for example,
I/O unit).
• Mains power IEC connectors to both DN9680s.
2.4 Powering the unit on/o
Swith on the mains on/o switch of both DN9680s (rear panel). The blue roundel
on the front panel of the unit should illuminate to show that power is on.
2.5 Conguration
Congure the DN9680s to suit the system parameters (for example, clock source,
sample rate frequency, etc.). For details, see "6. Conguring The DN9680 " on
page 8.
Other manuals for DN9680
2
Table of contents
Other Klark Teknik Extender manuals