KM 1000 SXPX HOTBOX User manual

KM 1000 SXPX HOTBOX
ORIGINAL INSTRUCTIONS
PROPANE BURNER HEATING SYSTEM
TM
THE CHOICE OF ASPHALT PROFESSIONALS WORLWIDE
KM INTERNATI0NAL
6561 Bernie Kohler Drive, North Branch, Michigan
Tel 810-688-1234 Toll Free 800-492-1757 Fax 810-688-8765
www.kminternational.com
© 2010 Keizer-Morris International. All Rights Reserved. Keizer-Morris, Crack Jet, the KM Emblem, and all other
KM names and symbols are Trademarks owned by KM International

TM
KM 1000SXPX v.jul.16.1 Page 1
Phone: 810-688-1234 Toll Free: 800-492-1757 Fax: 810-688-8765
www.kminternational.com © 2010 Keizer-Morris International. All Rights Reserved.
CONTENTS
INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
SAFETY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
KM ASPHALT HOTBOX RECLAIMER . . . . . . . . . . . . . . . . . 4
SET UP - SECURING THE KM 4000 HOTBOX . . . . . . . . . . 5 -6
FILLING THE KM 1000SXPX . . . . . . . . . . . . . . . . . . . . . . . 7
BURNER OPERATING INSTRUCTIONS (LP). . . . . . . . . . . . 8
BURNER OPERATING CONTROLS (LP) . . . . . . . . . . . . . . 9
RECYCLING & STORAGE OF HOTMIX ASPHALT . . . . . . . 10
TROUBLESHOOTING . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 - 12
LIMITED WARRANTY . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
TRAINING POLICY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
EQUIPMENT INFORMATION & NOTES . . . . . . . . . . . . . . .15

TM
KM 1000SXPX v.jul.16.1 Page 2
Phone: 810-688-1234 Toll Free: 800-492-1757 Fax: 810-688-8765
www.kminternational.com © 2010 Keizer-Morris International. All Rights Reserved.
INTRODUCTION
The KM International Team would like to take this opportunity to THANK YOU for your
purchase of the KM 1000SXPX. We at KM International are confident that our Asphalt
Hotbox/Reclaimer will offer years of safe, reliable and cost effective “ASPHALT HEATING
and RECLAMATION.”
The KM 4000 Asphalt Hotbox/Reclaimers are designed to maintain Hot Mix Asphalt
(HMA) at working temperature for up to three days. Our Hotbox/Reclaimers are specially
designed and manufactured at our North Branch Michigan facility to recycle cold-
chunked HMA. Solid welded construction stands up to a lifetime of commercial use.
The simple, straight forward design has little to go wrong and makes maintenance easy
and cost effective. Safety is a main concern when working with any fuel combustion
system and the KM 4000SXPX's system should be no exception.
KM International, Inc. has acquired and developed a number of strengths that has
fostered KMI’s worldwide reputation in the “ASPHALT REPAIR” industry as the “Gold”
and “Green” standards. We are the preeminent authority on the “infrared process” of in-
place “surface heating” and “recycle and repair.” We have fostered an ongoing industry
standard of quality and excellence that continually exceeds our customers’ expectations
in all of our other product offerings including our “Hot Box/Reclaimer” line of
equipment.
Our commitment to the design and manufacture of the highest quality surface
maintenance and repair equipment in the market is not just a “quote on the wall” but
rather the driving force for the entire KMI team. Our 28 years in the “Asphalt
Maintenance” industry has provided KM INTERNATIONAL the necessary experience to
provide our customers the “peace of mind” that only knowledge through experience can
accomplish; know how that our customers have come to rely on. The Management Team
at KM INTERNATIONAL is confident that YOUR purchase of the KM 1000SXPX will be
the basis for a long standing and profitable relationship.
The Goal at KM INTERNATIONAL has, and will always be, the manufacture of
Hotbox/Reclaimers that provide our customers cost savings, purchase justification and
profitability.

TM
KM 1000SXPX v.jul.16.1 Page 3
Phone: 810-688-1234 Toll Free: 800-492-1757 Fax: 810-688-8765
www.kminternational.com © 2010 Keizer-Morris International. All Rights Reserved.
SAFETY AND WARNING INFORMATION
NOTICE: This unit is not ATEX Certified. Do Not use in any explosive
environment.
NOTICE: READ and UNDERSTAND all instructions carefully before starting the KM
1000SXPX. FAILURE TO FOLLOW these instructions may result in a possible fire
hazard and will void the warranty.
WARNING: Any safety screen or guard removed for servicing must be replaced before
operating the KM 1000SXPX. DO NOT USE the Hotbox if any part has been damaged
or placed under water. Immediately CALL a qualified service technician to inspect the
hotbox and replace any damaged parts of the control system.
NOTICE: Maintenance or repair should be performed by a qualified service person.
The KM 1000SXPX system should be INSPECTED before initial use and at least
annually by a professional KMI service person. It is IMPERATIVE that the unit’s control
compartment, burners, and circulating air passageways ARE KEPT CLEAN to provide
for adequate combustion and ventilation air. Always keep the KM 1000SXPX clear and
free from combustible materials, gasoline, and other flammable vapors and liquids. The
Combustion chamber should be inspected annually or when evidence of excessive heat
exists. This can be evidenced by paint discoloration near or burner combustion chamber
area.
NEVER OBSTRUCT the flow of combustion and ventilation air. Keep the front of the
KM 1000SXPX CLEAR of all obstacles and materials for servicing and proper operation.
NOTICE: Children and adults should be alerted to the hazards of high surface
temperature and should STAY AWAY to avoid burns or clothing ignition.
WARNING: Always wear protective clothing, including eye and ear protection,
leather protective gloves, long sleeved protective shirt, long pants, and leather
protective boots when operating this or any other equipment.
NOTICE: The KM 1000SXPX is designed to heat asphalt to a working
temperature that should not exceed 350 *F (176 *C). The heated asphalt and the unit
will become DANGEROUSLY hot quickly; care and caution must be observed at all
times. Be aware of your surroundings. Use caution around buildings, utility wires,
combustibles, landscaping, etc. to prevent damage.
IT IS HIGHLY RECOMMENDED THAT YOU HAVE A FIRE EXTINGUISHER ON
YOUR JOB SITE AT ALL TIMES.

TM
KM 1000SXPX v.jul.16.1 Page 4
Phone: 810-688-1234 Toll Free: 800-492-1757 Fax: 810-688-8765
www.kminternational.com © 2010 Keizer-Morris International. All Rights Reserved.
KM ASPHALT HOTBOX RECLAIMER
The KM 1000 Asphalt Hotbox/Reclaimer is designed to maintain hot mix asphalt at
working temperature for up to three days as well as reclaim, or recycle, cold-chunked
hot mix asphalt. The KM 1000 will safely maintain hot mix asphalt at workable
temperatures during all seasons. The solid welded construction and straight forward
design is simple to use and requires little maintenance.
NOTICE: Safety is always a concern when working with any fuel combustion system
and the KM 1000SXPX LPG fuel burner system is no exception.
WARNING: PROPANE FUEL LEAKS PRESENT A DANGER and must be corrected
prior to operating the burner.
The burner is designed to burn LPG (PROPANE) ONLY. NEVER USE ANOTHER
COMBUSTIBLE FUEL.
HOW THE HOT BOX RECLAIMER HEATS
The KM 1000SXPX uses a 60,000 BTU, vapor withdraw propane burner controlled with
a 750 mV powered combination gas control valve to produce heat inside of the
combustion chamber. The heat energy circulates throughout the combustion chamber
area heating the asphalt storage bin. Energy is then transferred by conduction through
the storage bin walls into the asphalt.
The burner is thermostatically controlled and will automatically cycle on and off to
maintain the selected temperature. Two full 30 lb LP fuel cylinders should provide 48+
hours of continuous burner operation. Actual operating time between refueling could
be longer depending on ambient temperature, thermometer setting and volume of
asphalt in the storage bin.
Heat energy circulation and transfer is key to maintaining proper asphalt temperature.
Air flow intake and exhaust should never be obstructed. The interior of the asphalt
hopper should be kept clean daily to allow optimal conduction from the interior
combustion chamber into the asphalt load.
WARNING: Never clean the asphalt chamber with a combustible solvent. Doing so
will result in fire or explosion.
Daily cleaning with a shovel or flat spade is the best maintenance for the interior of the
KM Asphalt Hotbox.

TM
KM 1000SXPX v.jul.16.1 Page 5
Phone: 810-688-1234 Toll Free: 800-492-1757 Fax: 810-688-8765
www.kminternational.com © 2010 Keizer-Morris International. All Rights Reserved.
SET UP - SECURING THE HOTBOX TO YOUR VEHICLE
WARNING: It is necessary to safely secure the KM 1000SXPX to your vehicle.
Failure to do so can result in serious injury should the unit come loose from the
vehicle.
WARNING: Do not mount directly onto a
combustible surface.
The underside of the KM 4000 is hot during
operation. It may be necessary to mount the KM
1000 onto a heat resistant (metal) surface.
Weight Empty: 375 lbs. (170 kg)
Weight Full: 1,375 lbs (624 kg)
The KM 1000 can be mounted by bolting the
unit down at the bottom four corners. Use
suitable hardware and mounting structure on
the vehicle.
Additional securing locations are found at the
four outside corners of the KM 1000SXPX.
Suitable tie down chains or other hardware can
be used.
NOTICE: It is necessary to bolt the unit
down at the four bottom corners. The outside
secure points are additional support only.
Length: 57 1/2" (146 cm) Box: 54" (127 cm)
Width: 32 1/2" (82.5 cm) Box: 48" (66 cm)
Height: 31 1/2" (80 cm)
Weight Empty: 375 lbs. (170 kg)
Weight Full: 1,375 lbs (624 kg)
WARNING: The KM 1000SXPX must be safely
secured to the vehicle before transport. All securing
hardware and all additional tools should be
inspected and properly stowed daily.

TM
KM 1000SXPX v.jul.16.1 Page 6
Phone: 810-688-1234 Toll Free: 800-492-1757 Fax: 810-688-8765
www.kminternational.com © 2010 Keizer-Morris International. All Rights Reserved.
SET UP - SECURING ACCESSORY ITEMS
WARNING: It is necessary to safely secure the KM 1000SXPX and all other
optional equipment to your vehicle. Failure to do so can result in serious injury should
the unit come loose from the vehicle.
The KM 1000 is equipped with four accessory
tie down brackets that can be used to secure
tools, extra propane cylinders or other.
NOTICE: Always properly and safely secure
propane cylinders.
WARNING: Fire or explosion hazard can
cause property damage, severe injury, or death.
Consult state and local codes for the lawful
storage and transport of propane cylinders.
The KM 1000 is fitted with a shovel tray that
bolts directly to the shovel door tracks. Use
3/8" locking nuts to fasten the shovel tray.
The KM 1000 is supplied standard with one
30 lb. LP fuel cylinders.
A flexible high pressure propane hose is
supplied for connecting the fuel cylinder.
NOTICE: Consult local codes for proper
securing of fuel cylinders for travel.

TM
KM 1000SXPX v.jul.16.1 Page 7
Phone: 810-688-1234 Toll Free: 800-492-1757 Fax: 810-688-8765
www.kminternational.com © 2010 Keizer-Morris International. All Rights Reserved.
FILLING THE KM 1000SXPX
WARNING: Always wear protective clothing, including eye and ear protection,
leather protective gloves, long sleeved protective shirt, long pants, and leather
protective boots when operating this or any other equipment. Be aware of local safety
notices including hard hat and eye protection zones.
WARNING: Hot mix asphalt temperatures exceed 300oFahrenheit (148 Celsius).
The KM 1000 will need to be loaded by hand
because of the size and capacity of the unit.
NOTICE: It is unsafe to attempt to fill the
hotbox at a typical asphalt plant.
Stockpiling virgin hotmix asphalt is a recommended
method enabling users to fill, and then reclaim, for
use.
See RECYCLING & STORAGE of HOTMIX ASPHALT for
temperature and time recommendations.
Note: Asphalt mix design varies per producer.
Fill the KM 1000 with the amount of asphalt that is
anticipated will complete the job. Small amounts of
asphalt can sometimes be reclaimed in as little as
four hours.
Note: Asphalt weight to volume ratios, as well as
required heating time and temperature, are
dependent on hot mix asphalt specification per
location.

TM
KM 1000SXPX v.jul.16.1 Page 8
Phone: 810-688-1234 Toll Free: 800-492-1757 Fax: 810-688-8765
www.kminternational.com © 2010 Keizer-Morris International. All Rights Reserved.
BURNER OPERATING INSTRUCTIONS (LP)
LIGHTING INSTRUCTIONS
1. Slowly open the propane cylinder. Be sure not to activate
the safety excess flow valves in the bottle fittings.
Note: Opening a cylinder too quickly will activate a safety
excess flow valve caused by a surge in fuel flow. This will limit
the amount of fuel allowed to leave the hose fitting.
2. Set the thermostat to lowest setting.
3. Push in the gas control knob slightly and turn clockwise to
“OFF.” Note: Knob cannot be turned from “PILOT” to “OFF”
unless knob is pushed in slightly. DO NOT FORCE.
4. Turn the knob on gas control counterclockwise to PILOT.
5. Push the control knob all the way in and hold. Immediately
push the electric igniter button. Continue to hold the control
knob while visually checking to see that the pilot light has lit
inside the heating chamber along the burner.
Once the pilot has lit, hold the control knob in for one (1)
minute. Release the knob and it will pop back up. The pilot
should remain lit. If it goes out, wait two minutes to allow gas
to clear, repeat steps three through five (3-5).
6. Turn the gas control knob counterclockwise to “ON.”
7. Set the thermostat to desired temperature setting.
WARNING: Operating the burner during travel may cause
failure resulting in personal injury or equipment damage not
covered under warranty.
Shown is a view of the burner during operation.
Notice clean blue flames (3/4" - 1" tall) from end to end on
the burner.
The pilot flame will be yellow and aim toward the burner and
straight up, heating the 750 mV generator.

TM
KM 1000SXPX v.jul.16.1 Page 9
Phone: 810-688-1234 Toll Free: 800-492-1757 Fax: 810-688-8765
www.kminternational.com © 2010 Keizer-Morris International. All Rights Reserved.
BURNER OPERATING CONTROLS (LP)
*KM 4000SXPX shown in pictures.
Propane fuel supply
hoses
Thermostat
Gas control valve
9V Igniter
LP Burner Control Panel.
Gas Control Valve, Igniter,
Thermostat (Standard)
Burner access panel.
Automatic Changeover
Regulator
Venturi Air Mixer
Air Shutter &
Packing Nut
Pilot Light Assembly
Fuel lines to Venturi Air
mixer & Pilot Light
Igniter wire & Mv Generator
wire
Igniter Electrode
750 mV Generator
Gas control knob
Insulated
ignition cable
Pilot light fuel line

TM
KM 1000SXPX v.jul.16.1 Page 10
Phone: 810-688-1234 Toll Free: 800-492-1757 Fax: 810-688-8765
www.kminternational.com © 2010 Keizer-Morris International. All Rights Reserved.
RECYCLING & STORAGE of HOTMIX ASPHALT
Reclaiming “cold chunked” asphalt and storing
hot mix asphalt in your KM Hotbox can be done
efficiently and effectively by following some
guidelines and suggestions. Some of the factors
that should be considered when reclaiming or
storing in the KM hotbox are quantity of asphalt,
quality of asphalt and surrounding (outside)
temperature. Remember that these are suggested
averages. As a user of the equipment it will be
best to develop your own knowledge of reclaiming
and storing asphalt by frequency of usage and the
“trial and error” method.
Suggested temperatures (oF) for storage
of hotmix asphalt
2+ Ton 300oF
1 ½ Ton 275oF
1 Ton 275oF
½ Ton 275oF
NOTE: Depending on the quality of asphalt, storage of hot mix can last up to three days (72 hours).
(It is strongly recommended to keep hot mix no more than 48 hours.) Before working with stored
hot mix the KM Hotbox thermostat should be turned to 325oF at least one hour prior to work.
Reclaiming “cold chunked” asphalt takes approximately 8-12 hours depending on
quantity. It is recommended that the KM hotbox thermostat be turned to 325oF at least
one hour prior to work.
Remember that when recycling properly stored “chunked” asphalt, “what you put in,
you will get out”. Dirt and debris should be removed from the old asphalt prior to putting
it into the KM hotbox.
Older, lighter colored asphalt has oxidized and lost quality by depletion of some of the
light oils called maltenes. A maltenes rejuvenator is recommended and should be
applied as evenly as possible throughout the load at a rate of .10 gallons per square
yard of material. If you are unable to find rejuvenator locally, sprayers and rejuvenator
(CRF) are available from KM International.
Suggested temperature for reclaiming “cold chunked” asphalt: 300oF.

TM
KM 1000SXPX v.jul.16.1 Page 11
Phone: 810-688-1234 Toll Free: 800-492-1757 Fax: 810-688-8765
www.kminternational.com © 2010 Keizer-Morris International. All Rights Reserved.
TROUBLESHOOTING (KM Propane Burner Hotbox)
PROBLEM
INSPECT FOR SOLUTION
(A) Pilot will not light.
NOTICE: Maintenance
or repair should be
performed by a qualified
service person.
NOTICE: Maintenance
or repair should be
performed by a qualified
service person.
Ensure propane bottles have fuel and valves are open.
Propane cylinders have not been purged of air. Consult propane supplier.
Ensure change over regulator lever is entirely switched to one side or another.
Propane bottle excess flow valve –Be sure gas is flowing to the regulators. If the
bottle(s) is turned on too quickly it can trigger the excess flow of safety valve in
the bottle and shut off the flow of gas. Close propane bottle valve; safely relieve
line pressure, then slowly reopen valve.
Allow enough time to evacuate air from pilot line and let propane flow to pilot.
No spark at pilot light assembly.
NOTICE: Close gas cylinder and turn gas valve to off position.
Inspect the electronic igniter, check all wire connections include the ground wire.
An audible “clicking” should be heard when button is depressed. If not, igniter
unit may need to be replaced.
If equipped with an electric Piezo igniter, check all electrical connections. Ensure
that the Piezo is grounded. “Snap” the push button igniter; it is capable of
producing a three –sixteenth (3/16") inch blue spark. If no spark, then check the
spark gap at pilot assembly. If you are unable to produce a spark, then it will be
necessary to replace the electric Piezo igniter.
No Spark at pilot light assembly.
NOTICE: Close gas cylinder and turn gas valve to off position.
Inspect spark igniter electrode. Remove burner access safety panel and locate
igniter electrode.
Inspect spark wire connection.
Inspect the ceramic spark electrode for a crack or broken ceramic insulation.
Replace burner access safety panel after servicing.
Pilot orifice is plugged.
NOTICE: Close gas cylinder and turn gas valve to off position.
Remove burner access safety panel and locate the pilot light orifice connection at
the end of the 1/4" (small) propane fuel line. Remove the fuel line, then remove
the pilot orifice. Clean the orifice of debris. Note: It may be necessary to entirely
remove and clean or replace the 1/4" pilot fuel line.
Reinstall the pilot orifice and pilot fuel line. Inspect for leaks before returning the
unit to service.
WARNING: PROPANE FUEL LEAKS PRESENT A DANGER and must be corrected
prior to operating the burner.
Replace burner access safety panel after servicing.

TM
KM 1000SXPX v.jul.16.1 Page 12
Phone: 810-688-1234 Toll Free: 800-492-1757 Fax: 810-688-8765
www.kminternational.com © 2010 Keizer-Morris International. All Rights Reserved.
TROUBLESHOOTING (KM Propane Burner Hotbox)
PROBLEM
INSPECT FOR SOLUTION
(B) Pilot goes out when gas
control knob is released.
NOTICE: Maintenance
or repair should be
performed by a qualified
service person.
Ensure gas control knob is held at least one minute to allow the generator time to
heat.
Inspect the 750 Millivolt Generator. A consistent flame must surround the
generator cartridge. If it seems abnormally small then the pilot orifice needs
cleaning. See above.
Inspect Millivolt Generator output. The most effective test of the pilot generator
requires a Multi-meter with 0-1000 Millivolt (mV) scale. Connect the meter leads
to the valve of relay terminals to which the pilot generator wires are attached
while maintaining the pilot flame by continually depressing the gas control knob.
If the meter needle moves to the left of zero or no reading is indicated, reverse
meter probes. The meter must read 400 mV or more to effectively operate the
gas control valve. If the reading is low replace mV generator cartridge.
(C ) Burner will not ignite
when signaled by
thermostat.
NOTICE: Maintenance
or repair should be
performed by a qualified
service person.
Ensure the gas control knob is turned to the ON position.
Inspect thermostat. Remove thermostat cover to access the wire connections.
Use a multi-meter to check for continuity across the wire terminals when the
thermostat signals on. Voltage input and output can also be checked.
If a multi-meter is unavailable, a short jumper wire can be used to make contact
across the thermostat terminals. If the burner immediately operates, then
replace the thermostat.
Inspect the Millivolt Generator output. Potential across the valve with the pilot
light on should be 400 mV or more. If it is, yet valve does not open, replace valve.
If the potential is less than the minimum, check thermostat wire connections.
Replace thermostat if necessary.
Inspect Venturi Air Mixer - Ensure the Venturi air shutter is open and adjusted for
proper flame size. If the packing nut has come loose and the air shutter has closed
not allowing air to enter the Venturi, the burner may not have enough pressure to
ignite along the burner.
Adjust the air shutter and re-set the packing nut.
Replace burner access safety panel after servicing.
Inspect the Burner Orifice.
NOTICE: Close gas cylinder and turn gas valve to off position.
Locate the burner orifice in the Venturi Air Mixer. Remove the spud and orifice.
Inspect, clean of debris and re-install. It may be necessary to inspect, clean and
replace the 3/8" burner fuel line.
WARNING: PROPANE FUEL LEAKS PRESENT A DANGER and must be corrected
prior to operating the burner.
Replace burner access safety panel after servicing.
(D) Burner ignites but
flame is lazy, incomplete, or
erratic across the burner
tube.
Inspect Venturi Air Mixer - Ensure the Venturi air shutter is open and adjusted for
proper flame size. If the packing nut has come loose and the air shutter has closed
not allowing air to enter the Venturi, the burner may not have enough pressure to
ignite along the burner.
Adjust the air shutter and re-set the packing nut.
Replace burner access safety panel after servicing.

TM
KM 1000SXPX v.jul.16.1 Page 13
Phone: 810-688-1234 Toll Free: 800-492-1757 Fax: 810-688-8765
www.kminternational.com © 2010 Keizer-Morris International. All Rights Reserved.
LIMITED WARRANTY
KM INTERNATIONAL, INC. (hereinafter called KMI) warrants all equipment manufactured by KMI to be free from
defects in material and workmanship on the date of sale to the original end user. With the exception of any special,
extended, or limited warranty published by KMI, KMI will, for a period of twelve months from the date of sale, repair
or replace any part of the equipment determined by KMI to be defective. This warranty applies only when the
equipment is used for its intended purpose and properly maintained.
This warranty does not cover and KMI will not be liable for general wear and tear, or any malfunction, damage or
wear cased by misapplication, abrasion, corrosion, inadequate or improper maintenance, negligence, accident,
tampering, or substitution of non-KMI component parts.
This warranty is conditioned upon the prepaid return of the equipment claimed to be defective to an authorized KMI
distributor or the factory direct, for verification of the claimed defect. If the claimed defect is verified, KMI will repair
or replace free of charge any defective parts. Electrical components shall be returned in total. The equipment will be
returned to the original purchaser transportation prepaid. If inspection of the equipment does not disclose any defect
in material or workmanship, repairs will be made at a reasonable charge, which charges may include the costs of
parts, labor, and transportation. THIS WARRANTY IS EXCLUSIVE, AND IS IN LIEU OF ANY OTHER
WARRANTIES, EXPRESS OR IMPLIED. KMI’s sole obligation and buyer’s sole remedy for any breach of warranty
shall be set forth above. The buyer agrees that no other remedy (including, but not limited to, incidental or
consequential damages for lost profits, lost sales, injury to person or property, or any other incidental or
consequential lost) shall be available. Any action for breach of warranty must be brought within one (1) Year of date
of sale. Items sold, but not manufactured by KMI (such as electric motors, electric switch boards, switches, hose, etc)
are subject to the warranty, if any, of their manufacturer. KMI will provide purchaser with reasonable assistance in
making any claim for breach of these warranties or at KMI’s sole discretion shall accept the return in conjunction
with and/or despite the original manufacturers’ warranty.
In no event will KMI be liable for indirect, incidental, special or consequential damages resulting from KMI supplying
equipment hereunder, or the furnishing performance, or use of any products or other goods sold hereto, whether due
to a breach of contract, breach of warranty, the negligence of KMI or otherwise.

TM
KM 1000SXPX v.jul.16.1 Page 14
Phone: 810-688-1234 Toll Free: 800-492-1757 Fax: 810-688-8765
www.kminternational.com © 2010 Keizer-Morris International. All Rights Reserved.
TRAINING POLICY
The optimal and efficient operation of your KM Asphalt Hotbox Reclaimer requires instruction on the
operation and maintenance of the equipment. We at KMI are very much aware that time is a precious
commodity and will take all the steps necessary to ensure that equipment training is done in a professional
and expedient manner. We are in the process of developing a library of instructional videos that will be
available shortly. We encourage our customers to take advantage of our extremely knowledgeable staff
as needed for trouble shooting or to answer equipment operation questions. We are available during
business hours, 8:30 a.m. to 4:30 p.m. EST, Monday through Friday by phone –(810) 688-1234 or by e-
mail at kmi@kminternational.com. We encourage you to contact our sales staff to schedule a convenient
training session for your staff prior to operation.
If you are using the KMI infrared equipment for applying thermo-plastic, similar product or any use other
than asphalt reheating and repairing, our technicians are unable to answer specific questions on those
application processes. We would encourage the user to contact the applications manufacturer.
Additionally, we encourage our customers to take advantage of our hands on training classes made
available to all purchasers and their staff as requested and/or necessary. We have incorporated a small
fee associated with on sight training in an effort to encourage education without making the process cost
prohibitive or too time consuming for our staff. This small charge will help to keep KMI equipment price
competitive and user friendly. KM International will train FREE OF CHARGE any customer or customer
employees that travel to the KMI manufacturing facility within the first 90 days of purchase. We would be
happy to schedule an appointment for a free ½ day of training on every aspect of equipment maintenance
and operation. The customer would be responsible for travel and expenses to the KMI location. Our
technical staff is available to schedule an instructional full day of training at the customers site if that is
preferred but would require the following:
1. All travel and expense to and from the customer requested location as required, including Hotel
and Airfare as necessary. KMI reserves the sole right to determine appropriate and reasonable
accommodations and travel.
2. A per-diem food allowance of Fifty U.S. Dollars ($51.00) per technician, or as agreed.
3. A Five Hundred U.S. Dollar ($550.00) per diem off-site man charge per technician, or as agreed,
to be paid in advance.

TM
KM 1000SXPX v.jul.16.1 Page 15
Phone: 810-688-1234 Toll Free: 800-492-1757 Fax: 810-688-8765
www.kminternational.com © 2010 Keizer-Morris International. All Rights Reserved.
EQUIPMENT INFORMATION NOTES
MODEL
SERIAL NUMBER
PURCHASER
DATE OF PURCHASE
NOTES:
Thank you again for your purchase of the KM 4000SXPX Asphalt Hotbox Recyclaimer. We are happy to
have you as a customer and are confident that you will have years of efficient operation by following the
above parameters and guidelines. We encourage an open dialogue with our customers and prize any
feedback. Our commitment to our customers is second to none and our desire to improve our equipment
is an integral part of our ongoing growth strategy.
Sincerely,
The KM International Management Team.
KM International, Inc.
6561 Bernie Kohler Drive
North Branch, Michigan 48461
(810) 688-1234 * www.kminb.com
Please call the Team at KM International anytime for questions, comments or to just talk “Infrared.”
TM
THE “INFRARED PROCESS” WORLDWIDE EXPERTS
© 2010 Keizer-Morris International. All Rights Reserved. Keizer-Morris, Crack Jet, the KM Emblem, and
all other KM names and symbols are Trademarks owned by KM International.
Table of contents
Popular Heating System manuals by other brands

Vehicle Systems
Vehicle Systems Aqua-Hot AHE-100-04S Shop Manual

Napoleon
Napoleon DYNAMIC HEAT CONTROL PLUS Series Installation and operation manual

Magic-Pak
Magic-Pak EWC V-Series installation instructions

Klima therm
Klima therm KCX Operation and maintenance manual

United CoolAir
United CoolAir SCPAC5G AS Series Installation, operation and maintenance manual

alphainnoTec
alphainnoTec Solterra Brine WZ S 75H instruction manual

System air
System air fantech SHR200R installation manual

ProFusion
ProFusion PH-945 user manual

Ambirad
Ambirad Herringbone HB manual

Soler & Palau
Soler & Palau AKOR CONNECTION, INSTALLATION, MAINTENANCE

System air
System air SAVE VTR 150/K Installation and service

Viessmann
Viessmann Vitocell 100-H Technical guide