8
Air conditioner positioning requirements
• Do not install the air conditioner near heat sources or gas leakages, nor in areas with
inflammable or explosive gases.
• Avoid installing in places subject to strong artificial electric/magnetic fields.
• Avoid installing in places subject to noise and resonance.
• Avoid installing the outdoor unit near areas with frequent severe natural conditions
(for example, strong sandy winds, direct sunshine, or high-temperature heat sources).
• Avoid installing in areas within the reach of children.
• Shorten the connection between the indoor and outdoor units. Select a
well-ventilated area where it is easy to perform service and repair.
• Do not install the outdoor unit where it can occupy a public area (for example, an
aisle, stairway, exit, fire escape, catwalk, or any other public area).
• Ensure the outdoor unit is installed as far as possible from the doors and windows of
the neighbours as well as green plants.
Mounting plate requirements
• The mounting plate must meet the relevant national or industrial standards in terms
of strength, with welding and connection areas rust proofed.
• The mounting plate and its load carry surface must be able to withstand 200kg.
• The mounting rack of the outdoor unit must be fastened with an expansion bolt.
• To p r ev e n t t h e u n i t s f ro m f a l l i n g , e n s u r e t h e p r o p e r p r e c a u t i o n s a r e t a k e n ( fo r
example, taking into account the type of wall it is being attached to).
Electrical safety requirements
• Ensure to use the rated voltage and air conditioner dedicated circuit for the power
supply.
• Ensure the diameter of the power cable meets national requirements.
• When the maximum current of an air conditioner is >16A (8.0KW), it must use an air
switch or leakage protection switch equipped with protection devices.
• The operating range of the air conditioner is 90%-110% of the local rated voltage. If
there is an insufficient power supply, this may cause malfunctions, electrical shock, or
fire.
• If the level of voltage is unstable, it is suggested to increase the voltage regulator.
• Keep combustibles at least 1.5 metres away from the air conditioner.
• The interconnecting cord (not supplied) connects the indoor and outdoor units.
Choose the appropriate cable size before preparing it for connection.
• The interconnecting and outdoor power cables must be either H07RN-F or
H05RN-F.