Kollmorgen N-Port Express DE-311 Quick guide

Ethernet-Gateway
Configuration
Kollmorgen Steuerungstechnik GmbH Kollmorgen Lift Controls Ltd.
Broichstrasse 32 Unit 2, The Office Village
D-51109 Köln Chester Business Park
Telefon +49 (0) 221 89 85 0 Chester, Cheshire, CH4 9QP
Telefax +49 (0) 221 89 85 30 Telephone + 44 (0) 1244-67 85 49
http://www.kollmorgen.de Fax +44 (0) 1244-68 15 78
KOLLMORGEN Steuerungstechnik GmbH Köln / 23.09.2010 / DO_EthernetGW_konfig_gb

Ethernet-Gateway
Configuration
Contents
1Ethernet-Gateway <<N-Port Express DE-311>>............................................................. 3
2Introduction....................................................................................................................... 3
3Configuring the Ethernet Gateway.................................................................................. 3
3.1 Set the Network ..........................................................................................................................5
3.2 Set the Operating State..............................................................................................................6
3.3 Set the Serial Interface...............................................................................................................7
4Ethernet-Gateway <<NPort 5110>>................................................................................. 8
5Introduction....................................................................................................................... 8
6Configuring the Ethernet Gateway.................................................................................. 8
6.1 Set the Network ........................................................................................................................10
6.2 Set the Serial Interface.............................................................................................................11
6.3 Set the Operating State............................................................................................................12
6.4 Template import configuration................................................................................................14
6.5 Model for the Configuration Data Sheet.................................................................................16
223.09.2010

Ethernet-Gateway
Configuration
1 Ethernet-Gateway <<N-Port Express DE-311>>
1.1 Introduction
This description refers to the <<N-Port Express DE-311>> Ethernet gateway from <<Moxa Technologies
Ltd>>. Install the program <<dssetup.exe>> from the product CD on your PC to configure the gateway.
You will find this set-up program on the product CD under <<DE-311\software\driver\windows\>>.
The software needs Windows 2000 or Windows XP as an operating system.
1.2 Configuring the Ethernet Gateway
You can choose two ways to configure it:
direct Ethernet connection between the gateway and
PC via CROSS OVER cable GatewayLaptop
CROSS OVER - cable
RS232
Ethernet-
connection
interfacing via the standard (in-house) network Laptop
Ethernet-Network
Gateway
RS232
The descriptions below refer to the direct Ethernet connection that we recommend and they require
the standard factory setting for the configuration.
If you would like to reconfigure a machine already that has already configured, reset all values to the
standard factory setting. Then, to load the factory settings, press the reset button for at least 10 sec.
You can find the reset button on the machine next to the Ethernet interface.
Read the instructions in the machine description!
Please attend to the DIP switches of the ethernet-gateway.
All DIP switches must be located in the OFF position. 123
ON
ON OFF
23.09.2010 3

Ethernet-Gateway
Configuration
Here’s how to do it:
1. select the <<Configurator>> input under <<Start/Program/Nport Management Suite/>>.
2. start a network scan under <<Locate Server>> <<Broadcast Search>>
3. the gateway appears in the display
4. select the gateway input and press the right-hand mouse button for the context menu
5. select the <<Modify Configuration>> input
Do_vl_moxa1 / 50%
423.09.2010

Ethernet-Gateway
Configuration
1.3 Set the Network
Do_vl_moxa2 / 50%
dialog fields:
<<Server Name>>
key in the name for identifying the gateways. Please remember that this input is optional and
is not a network name
<<IP Address>>*
key in the IP address here where the gateway can be reached
<<network mask>>*
key in the network mask here for determining the targeted network
<<gateway>>*
key in the IP address of the gateway here for a connection to another network
<<IP Configuration>>
retain the <<Static IP>> setting
* you can get this information from the network administrator
23.09.2010 5

Ethernet-Gateway
Configuration
1.4 Set the Operating State
Do_vl_moxa3 / 50%
dialog fields:
<<Change OP_Mode>>
tick here and select the <<TCP Server>> input from the <<Port 1>> list
<<More settings>>
press the button and key in the port number 8000 in the <<TCP Port>> space
<<TCP alive check time>>
set the value to 1 minute
623.09.2010

Ethernet-Gateway
Configuration
1.5 Set the Serial Interface
Do_vl_moxa4
dialog fields:
<<Change Serial Port Settings>>
tick here
select the transmission rate <<9600>> from the <<Baud Rate>> list
select the <<None>> input from the <<Flow Control>> list
23.09.2010 7

Ethernet-Gateway
Configuration
2 Ethernet-Gateway <<NPort 5110>>
2.1 Introduction
The discription refers to the Ethernet-Gateway<<NPort 5110>>of <<Moxa Technologies Ltd>> using
Windows XP.
For configuration of the Ethernet-Gateway please install the programm
<<Npadm_Setup_Ver1.12_Build_09041012.exe>> of the product-CD on your PC.
The mentioned Setup-programm can be find on your product-CD. Just look for:
<<Software\Windows\Npadm_Setup_Ver1.12_Build_09041012\>>. .
Make sure that your operating system meets the minimum requirements for installation.
For further information please check your product-CD: <<Software\Windows\version>>.
You can find the complete manual on the product-CD <<Document\Nport 5100 Series\>>.
2.2 Configuring the Ethernet Gateway
You can choose two ways to configure it:
direct Ethernet connection between the gateway and
PC via CROSS OVER cable GatewayLaptop
CROSS OVER - Kabel
RS232
Ethernet-
Verbindung
interfacing via the standard (in-house) network Laptop
Ethernet-Netzwerk
Gateway
RS232
The descriptions below refer to the direct Ethernet
connection that we recommend and they require the
standard factory setting for the configuration.
If you would like to reconfigure a machine already that has
already configured, reset all values to the standard factory
setting.
To load the factory settings, please push the reset-button for
approximately 5 seconds. The “Ready”-LED starts to flash.
You can let go as soon as the LED stops.
You can find the reset button on the machine next to the
Ethernet interface.
Read the instructions in the machine description!
ED_DO_MOXA-5110-B01
823.09.2010

Ethernet-Gateway
Configuration
Here’s how to do it:
1. Select the <<Start/Programme/NPort Administration Suite/>> input under
<<Nport Administrator>>.
2. Start a network scan under <<Configuration>> <<Broadcast Search>>.
3. The gateway appears in the display.
ED_DO_MOXA-5110-B02 \ Bild 55%
4. Select the gateway input and press the right-hand mouse button for the context menu.
5. Select the <<Configure>> input.
ED_DO_MOXA-5110-B03 \ Bild 55%
23.09.2010 9

Ethernet-Gateway
Configuration
2.3 Set the Network
ED_DO_MOXA-5110-B04 \ Bild50%
Dialog fields:
<<Modify>>
tick here.
<<IP Address>>*
key in the IP address here where the gateway can be reached.
* you can get this information from the network administrator
10 23.09.2010

Ethernet-Gateway
Configuration
2.4 Set the Serial Interface
ED_DO_MOXA-5110-B05.png \ Bild 50%
dialog fields:
<<Modify>>
Tick here.
Select the gateway input.
Press the button<<Settings>> for detailed settings.
ED_DO_MOXA-5110-B06.png \ Bild 50%
dialog fields:
<< Baud Rate >>
Select the transmission rate <<9600>>.
<< Flow Control >>
Select the <<None>> input.
23.09.2010 11

Ethernet-Gateway
Configuration
2.5 Set the Operating State
ED_DO_MOXA-5110-B07.png \ Bild 50%
dialog fields:
<<Modify>>
Tick here.
Select the gateway input.
Press the button<<Settings>> for detailed settings.
12 23.09.2010

Ethernet-Gateway
Configuration
ED_DO_MOXA-5110-B08.png \ Bild 50%
dialog fields:
<<Operating Mode>>
Choose <<TCP Server Mode>>.out of the list.
<<Local TCP Port>>
Feed in portnumber 8000.
<<TCP Alive Check Timeout>>
Set the value to 1 minute.
23.09.2010 13

Ethernet-Gateway
Configuration
2.6 Template import configuration
ED_DO_MOXA-5110-B09.png \ Bild 55%
1. Start a network scan under <<Configuration>> <<Broadcast Search>>.
2. The gateway appears in the display.
3. Select the gateway input and press the right-hand mouse button for the context menu.
4. Select the <<Import Configuration>> input.
5. Immediately you reach the basic settings.
14 23.09.2010

Ethernet-Gateway
Configuration
ED_DO_MOXA-5110-B10.png \ Bild 50%
dialog fields:
<<Modify>>
Tick here.
Under <<Server Name>> you can fill in the name for Gateway identification.
Please remember that this input is optional and is not a network name.
Please note: the standard IP-address is pledged in the imported data file.
Change the preset IP-address if necessary ( please look up “4.1 network settings”).
<<Modify>>
Tick here.
<<Enable Web Console>>
Tick here.
<<Enable Telnet Console>>
Tick here.
23.09.2010 15

Ethernet-Gateway
Configuration
16 23.09.2010
3 Model for the Configuration Data Sheet
project:
customer:
date of installation:
control type:
VisualLift version:
MPK lift version:
MPK installation ID:
DLON-IO interface version:*
DLON v.24 gateway version:*
gateway model name:
gateway Ethernet (MAC)
address:
gateway server name:
gateway IP address:
network mask:*
network gateway address:*
IP configuration: static IP
gateway mode: TCP server
TCP server port: 8000
serial parameters:
* if available/needed
Table of contents
Popular Gateway manuals by other brands

Logic IO
Logic IO RTCU NX-200 Technical manual

NETGEAR
NETGEAR supernet installation manual

ZyXEL Communications
ZyXEL Communications VMG8029 quick start guide

Lantronix
Lantronix X303 quick start guide

ZyXEL Communications
ZyXEL Communications ZyWALL 70 quick start guide

Fujitsu
Fujitsu GW1500 Getting started guide