Kongsberg Simrad SX90 Series User manual

316866/R
March2022©KongsbergMaritimeAS
PUBLIC
SimradSX90
Fish-ndingsonar
SoftwareReleaseNote
Release22.1
Thisdocumentdescribesthechangesintroducedwiththenewsoftware
version.
•Product:SX90
•Softwareversion:22.1
•Upgradefromversion:21.13
ThissoftwarecontrolsallfunctionalityintheSX90system.This
includestransmissionandreception,interfaceswithexternal
peripheralsandsensors,andalluserinterface.
ArmwareupdatefortheTransceiverUnitisnotincludedwiththis
release.
Additionalend-userdocumentsrelatedtotheSX90systemcanbe
foundonourwebsite.Thisincludespublicationsthataretranslatedto
otherlanguages.SelectedpublicationsarealsoprovidedonIETM
(InteractiveElectronicTechnicalManual)formats.
•https://www.kongsberg.com/sx90

KongsbergMaritimeAS
www.kongsberg.com
Documentinformation
•Product:SimradSX90
•Document:SoftwareReleaseNote
•Documentpartnumber:316866
•DocumentISBNnumber:N/A
•Revision:R
•Dateofissue:07March2022
Copyright
TheinformationcontainedinthisdocumentremainsthesolepropertyofKongsberg
MaritimeAS.Nopartofthisdocumentmaybecopiedorreproducedinanyformorby
anymeans,andtheinformationcontainedwithinitisnottobecommunicatedtoathird
party,withoutthepriorwrittenconsentofKongsbergMaritimeAS.
Warning
Theequipmenttowhichthismanualappliesmustonlybeusedforthepurposefor
whichitwasdesigned.Improperuseormaintenancemaycausedamagetothe
equipmentand/orinjurytopersonnel.Youmustbefamiliarwiththecontentsofthe
appropriatemanualsbeforeattemptingtooperateorworkontheequipment.
KongsbergMaritimedisclaimsanyresponsibilityfordamageorinjurycausedby
improperinstallation,useormaintenanceoftheequipment.
Disclaimer
KongsbergMaritimeASendeavourstoensurethatallinformationinthisdocumentis
correctandfairlystated,butdoesnotacceptliabilityforanyerrorsoromissions.
Supportinformation
Ifyourequiremaintenanceorrepair,contactyourlocaldealer.Youcanalsocontactus
usingthefollowingaddress:[email protected].Ifyouneed
informationaboutourotherproducts,visithttps://www.kongsberg.com/simrad.Onthis
websiteyouwillalsondalistofourdealersanddistributors.

316866/R3
Tableofcontents
SOFTWARECHANGES..............................................................5
DOINEEDTOUPGRADE?........................................................7
SOFTWARELICENSES..............................................................8
SOFTWAREINSTALLATION......................................................9
Removingtheoperatingsoftware......................................................................................9
Installinganewversionoftheoperatingsoftware..........................................................11
Settingsyouneedtorestoreafterasoftwareupgrade.....................................................12
END-USERDOCUMENTATION................................................13
UPDATEDFUNCTIONSANDDIALOGBOXES...........................14
UserSettingsSetuppage................................................................................................14
Unitspage........................................................................................................................15
NewMarkerdialogbox...................................................................................................17
OperatingPanelpage.......................................................................................................17
OperatingPanelMk2..............................................................................................19
OperatingPanelMk3..............................................................................................23
DisplayOptionsdialogbox.............................................................................................26
Generalpage...........................................................................................................26
MINIMUMDISPLAYREQUIREMENTS.....................................30
SoftwareReleaseNote

4316866/R
SimradSX90

316866/R5
Softwarechanges
Thissoftwareupdatesolvesanumberofsoftwarebugsthathavebeenreportedbyour
users,ordetectedduringourownproducttesting.Newfunctionalityisalsointroduced.
Note
Ifyouupgradefromversion3.1.8orearliermakesuretoreadthereleasenotefor
softwareversion21.13.21.
Thefollowingspecicchangeshavebeenmade.
Performancestabilityimprovements
Someuserswithsoftwareversion21.13.21installedreportedthatthesonarwould
stopforshortperiodsgivingapingtimeoutmessage.Thisissueisnowxed.
Rollandpitchimprovements
Therollandpitchoffsetfunctionalityhasbeenimproved.Theoffsetvaluesnow
followtherotationofthemotionsensor(ifithasrotation).
Improvedpresentationofwatercurrent
Thepresentationofthewatercurrentlayersareupdatedtoshowspeedwith
decimals.
Newtrackedtargetmaynotbeprioritytarget
Normally,anewtrackedtargetwillbegivenprioritystatusandtakecontrolofthe
tiltandbearingsettings.Youcannowpreventthissothatanewtrackedtargetdoes
notautomaticallybecomeaprioritymarker.UseanewsettingintheUserSetting
SetuppageintheInstallationdialogbox.
UserSettingsSetuppage,page14
Unitsforpositionformats
OntheUnitspageyoucannowchoosedifferentunitsforthegeographicalposition
format.ThesameunitsarethenalsoavailableintheNewMarkerdialogbox.
Unitspage,page15
NewMarkerdialogbox,page17
Softwarechanges

6316866/R
AdditionalfunctionalityaddedtoOperatingPanelsMk2andM3
IntheOperatingPanelpageforMk2andM3youicannowchoosetouseoneof
thebuttonstodeletetheoldestmarker.
OperatingPanelMk2,page19
OperatingPanelMk3,page23
Temperaturereadoutontopbar
Ifyouhaveasuitablesensorconnectedtoyoursystem,theseatemperaturecanbe
shownonthetopbar.
Generalpage,page26
SimradSX90SoftwareReleaseNote

8316866/R
Softwarelicenses
TheSimradSX90isnotalicensedproduct.
TheSX90systemdoesnotneedanysoftwarelicensestooperate.However,specic
softwarelicensecodes"unlocks"additionalfunctionality.
Thesoftwarelicenseisa32characterhexadecimalstringbasedonthehardware
identier(HardwareID).Thisuniqueidentierisgeneratedusinginformationfrom
keycomponentsintheProcessorUnit.Thesoftwarelicenseislinkedtothephysical
ProcessorUnit.YoucannotmovetheSX90systemsoftwarefromoneProcessorUnitto
anotherunlessyoualsorequestandinstallanewlicense.
Inordertoobtainasoftwarelicenseyoumustcontactoneofourdealersordistributors.
Youcanalsousetherequestformonourwebsite,orcontactoursupportdepartment
directly.
SimradSX90SoftwareReleaseNote

316866/R9
Softwareinstallation
WhenanewsoftwareversionisreleasedfortheSX90systemitmustbeinstalledon
yourProcessorUnit.Contactyourlocaldealer,oraSimraddistributor,tohavethe
newsoftwareversioninstalled.
Note
Youmustremovetheoldversionofthesoftwarebeforeyouinstallthenewversion.
Adedicatedwizardisusedtoinstallthesoftware.Installationofadditionaloperating
systemcomponentsmayberequired.Theseareinstalledautomatically.Observethe
informationofferedinthewizard.
Registereddealersanddistributorscandownloadthenewsoftwareversionfromthe
"SimradDealerClub".Toaccessthe"SimradDealerClub",visitourwebsite.
•www.kongsberg.com/sdc
Topics
Removingtheoperatingsoftware,page9
Installinganewversionoftheoperatingsoftware,page11
Settingsyouneedtorestoreafterasoftwareupgrade,page12
Removingtheoperatingsoftware
Beforeyoucaninstallthenewsoftwareversion,youmustremovetheoldversion.
Prerequisites
Thefollowingitemsmaybeuseful:
•Computermouse
•Computerkeyboard
Neithertoolsnorinstrumentsarerequired.ThisprocedureismadefortheMicrosoft®
Windows®10operatingsystem.Itisassumedthatyouarefamiliarwiththisoperating
system.
Softwareinstallation

10316866/R
Context
Removalofthesoftwareisdoneusingfunctionalityprovidedbytheoperatingsystem.
Procedure
1TurnontheProcessorUnit.
2SelectPowerofftoturnoffthesystem.
3InthePowerOffdialogbox,selectExittoOperatingSystemtoclosethe
SX90program.
4Ifapplicable:ConnectthekeyboardandthemousetoUSBsocketson
thefrontpaneloftheProcessorUnit.
5Uninstalltheapplication.
aIfapplicable:Opentheon-screenkeyboard.
bInthebottomleftcornerofyourdesktop,selectthelookingglasstostart
asearch.
cTypeControlPaneltolocatetheapplication,thenopenit.
dSelectProgramsandFeatures.
eOnthelistprovided,locatethesoftwareyoushalluninstall.
fSelectit,thenselectUninstall.
gObservetheRemoveexistingsettingsdialogbox.
hDonotselectanycheckboxes!
iSelectUninstallinthedialogboxtoremovethesoftware.
jFollowtheinstructionsprovidedbythewizard.
6Clickthe[X]inthetoprightcornertoclosetheControlPanel.
7Ifapplicable:DisconnectthekeyboardandthemousefromtheProcessorUnit.
SimradSX90SoftwareReleaseNote

316866/R11
Installinganewversionoftheoperating
software
Adedicatedwizardisusedtoinstallthesoftware.TheoperatingsoftwarefortheSX90
systemmustbedownloadedonaseparatecomputer.
Prerequisites
Thefollowingspecicitemsarerequiredforthistask:
•Personalcomputer
•USBashdrive
•Computermouse(Optional)
•Computerkeyboard(Optional)
Neithertoolsnorinstrumentsarerequired.ThisprocedureismadefortheMicrosoft®
Windows®10operatingsystem.Itisassumedthatyouarefamiliarwiththisoperating
system.
Procedure
1Onthepersonalcomputer:
aDownloadthenewsoftwareversion.
bUnpacktheZIPletoaccesstheexecutableapplicationle.
cCopytheapplicationletoaUSBashdrive.
2TurnontheProcessorUnit.
3Makethefollowingpreparations.
aIfapplicable:ConnectthekeyboardandthemousetoUSBsocketsonthefront
paneloftheProcessorUnit.
bInserttheUSBashdrive.
4Installthenewversionoftheapplication.
aFromtheWindows®Startbutton,right-clicktoopenFileExplorer.
bLocatetheexecutablesetuple(.exe).
cCopytheletoatemporaryfolderonthe"D"drive.
dDouble-clickthesetupexecutableletostarttheinstallation.
eSelectthecheckboxtoacceptthelicensetermsandconditions.
fSelectInstall.
gFollowtheinstructionsprovidedbythewizard.
Werecommendthatyouinstallthesoftwareinthedefaultfoldersuggested
bythewizard.
Softwareinstallation

12316866/R
hCloseFileExplorer.
iRemovetheUSBashdrive.
5OntheProcessorUnitdesktop,double-clicktheSX90icontostarttheprogram.
6Ifapplicable:DisconnectthekeyboardandthemousefromtheProcessorUnit.
Settingsyouneedtorestoreafterasoftware
upgrade
DuetothemultiplesoftewarechangesmadetotheSX90system,certainsettingsmustbe
restoredafterthesoftwareupgrade.
Note
Youonlyneedtorestorethesesettingsifyouareupgradingfromsoftwareversion3.1.8.
Colourscales
IntheColourSetupdialogbox,allexistingusersettingswillforEchoColourswill
reverttoNormsl.Ifyouhaveusersettingswithothersettingsyouneedtoload
theseusersettings,changeEchoColoursfromNormaltoyourownpreference.To
keepthesamenamefortheusersetting,justdeleteitrstandsavewitholdname.
ModeSelectiononOperatingPanelpage
Thedefaultvalueforthissettingisnowtochangepresentationmodes.Ifyoustill
wishtousethebuttonstoselectusersettingsyoumustactivatethisbydeselecting
.Theoldusersettingswillstillbethere.
CongurationofOperatingPanelMk1
TheMk1OperatingPanelusesseriallineCOM1tocommunicatewiththe
ProcessorUnit.Thissettingmustbereconguredafterthesoftwareupgrade.
SimradSX90SoftwareReleaseNote

316866/R13
End-userdocumentation
TheenduserdocumentationandonlinehelpfortheSX90systemisnotupdatedwiththe
latestsoftwarerelease.
TheSX90ReferenceManualisincludedwiththeSX90softwareascontextsensitive
on-linehelp.
Additionalend-userdocumentsrelatedtotheSX90systemcanbefoundonourwebsite.
Thisincludespublicationsthataretranslatedtootherlanguages.Selectedpublications
arealsoprovidedonIETM(InteractiveElectronicTechnicalManual)formats.
•https://www.kongsberg.com/sx90
End-userdocumentation

14316866/R
Updatedfunctionsand
dialogboxes
Thisnewsoftwareversionhasresultedinchangestosomeofthefunctionsanddialog
boxesintheSX90userinterface.
Topics
UserSettingsSetuppage,page14
Unitspage,page15
NewMarkerdialogbox,page17
OperatingPanelpage,page17
DisplayOptionsdialogbox,page26
UserSettingsSetuppage
TheUserSettingsSetuppageisestablishedtooffergenericsettingsthatdonotnaturally
belongelsewhere.
Prerequisites
TheInstallationdialogboxisnotavailablewhenyourSX90systemissettoReplaymode.
Howtoopen
ThispageislocatedintheInstallation
dialogbox.Toopenthepage,select
InstallationontheSetupmenu.
Description
UserSettings
TheUserSettingsdialogboxallowsyoutosavethecurrentusersettings(your
currentselectionofoperationalparameters),andtoretrievefactoryorpreviously
SimradSX90SoftwareReleaseNote

316866/R15
savedusersettings.Thesesettingscanberelatedtodifferentoperations,
environmentalconditionsorbasicpersonalpreferences.Bydefault,information
aboutthecurrentrange,bearingandtiltwillnotbesaved.OntheUserSettings
Setuppage,ticktheboxtoincluderange,bearingandtiltinformationthenext
timeyousavetheusersettings.
NewManuallyInitiatedTrack
Duringnormaloperation,someechoesareclearlymoreinterestingthanothers.In
manysituationsspecicechoesmayberegardedastargets.TosetuptheSX90
systemtoprovidesuchinformation,youcanstarttargettracking.
TheInitiateTrackfunctionallowsyoutomanuallystarttargettracking.
Placethecursorovertheechoyouwishtotrack.SelectInitiateTrack.Thetracked
targetisregardedasanobject,anditisidentiedwithacircleandtwolines.The
bearinglineisautomaticallylockedontheobjecttoreectsitsbearing.
Bydefault,anewmanuallyinitiatedtrackedobjectisautomaticallygivenpriority
status.Ifanotherobjecthasthispriority,thestatusistransferredtothenewobject.
Thepriorityisidentiedwitha"P".
OntheUserSettingsSetuppage,de-selectNewManuallyInitiatedTrackifyoudo
notwantnewtrackedtargetstobecomeprioritytargets.
Relatedfunctionality
UserSettingsdialogbox
TheUserSettingsdialogboxallowsyoutosavethecurrentusersettings(your
currentselectionofoperationalparameters),andtoretrievefactoryorpreviously
savedusersettings.ThisdialogboxisopenedfromtheMainmenu.
Unitspage
Theuserinterfacepresentsmanymeasurements.Thesemeasurementsareforexample
relatedtodepth,rangeanddistance.FromtheUnitspageyoucontrolwhichunits
ofmeasurementsthatareused.
Prerequisites
TheInstallationdialogboxisnotavailablewhenyourSX90systemissettoReplaymode.
Howtoopen
ThispageislocatedintheInstallationdialogbox.Toopenthepage,selectInstallation
ontheSetupmenu.
Updatedfunctionsanddialogboxes

16316866/R
Description
TheSX90systemispreparedtoworkwithseveralinternationalstandardsforunits
ofmeasurements.
UsetheUnitsoptionstoselecttheunitsofmeasurementsyouwanttoworkwith.The
SX90systemusestheminallpresentations.Youonlyneedtodenethemonce.Usethe
drop-downlistsprovidedtomaketheselections.
Note
WhenyouworkintheInstallationdialogbox,youmustalwaysselectApplytosavethe
changesmadeonapage.Youmustdothisbeforeyoucontinueworkingonadifferent
page.
Details
Length
Choosetheunitof
measurementforallthe
readoutsrelatedtorange
anddistancesintheSX90
systemuserinterface.
Thismayforexamplebe
thecursorlocation.
Depth
Choosetheunitof
measurementforallthe
presentationsofdepth.
Thismayforexamplebe
thecurrentwaterdepth.
Distance
Choosetheunitofmeasurementforallpresentationsofsaileddistance.
Position
Choosetheunitofmeasurementforgeographicalpositions.
Speed
Choosetheunitofmeasurementforallthepresentationsofvesselspeed.
Temperature
Choosetheunitofmeasurementforallthetemperaturereadings.Thismayfor
examplebethecurrentwatertemperature,butonlyifyouhaveasuitablesensor
connectedtotheSX90system.
FishLength
Choosetheunitofmeasurementforallpresentationsofshlength.
SimradSX90SoftwareReleaseNote

316866/R17
NewMarkerdialogbox
TheNewMarkerdialogboxallowsyoutocreateanewmarkerbasedontheknowndepth
andgeographicalpositionofanewtarget.
Howtoopen
TheNewMarkerdialogboxisopenedfromtheNewbuttonintheObjectsmenu.
Description
Usethisfunctionalityifyouneedtocreate
amarkerbasedongeographicalinformation
fromanexternalsource.Youcanplace
markersonforexamplewrecks,obstacles
ontheseabedorcoralreefs.Foreachnew
markeryoumustprovide:
•Longitude
•Latitude
•Depth
•PositionInputFormat
Whenthenewmarkeriscreated,itisautomaticallyassignedauniqueidentier(UID)by
theSX90system.
OperatingPanelpage
TheOperatingPaneloffersallnecessarycontrolfunctionsfornormaloperation.It
furtherallowsyoutoassigncertainfunctionstodedicatedbuttonsandswitches.The
OperatingPanelpageisusedtoselectwhichphysicalhardwarepanelyouuse,andto
assignfunctionalitytotheprogrammablebuttons.
Prerequisites
TheInstallationdialogboxisnotavailablewhenyourSX90systemissettoReplaymode.
Howtoopen
ThispageislocatedintheInstallationdialogbox.Toopenthepage,selectInstallation
ontheSetupmenu.
Description
ThecontrolsprovidedbytheOperatingPanelarearrangedinlogicalfunctionalgroups.
Thisoffersyouclearandeasyoperationwithfastaccesstokeyfunctionality.Allthe
Updatedfunctionsanddialogboxes

18316866/R
functionalityprovidedbytheSX90systemcanbeaccessedusingthetrackballonthe
OperatingPanelandthemenusystemshowninthedisplaypresentation.
TheSX90systemsupportsthreedifferentoperatingpanels.Thesearereferredtoas
"Mk1","Mk2"and"Mk3".
•TheMk1OperatingPanelisconnectedtotheProcessorUnitwiththreecables.The
dualinterfacecableprovidespowerandserialcommunication.TheUSBinterface
cableisusedtoreadthetrackballmovements.TheProcessorUnitmustbettedwith
acustommadeinterfaceboard.Asmallcommercialpowersupplyisusedtoprovide
powertotheOperatingPanel.(TheMk1OperatingPanelisnolongerprovidedwith
newsonars.Thisinformationisprovidedforlegacyreasons.)
•TheMk2OperatingPanelisconnectedtotheProcessorUnitusinganEthernetcable.
TheOperatingPanelisprovidedwithabuilt-inpowersupply.
•TheMk3OperatingPanelisconnectedtotheProcessorUnitwithaUSBcable.A
dedicatedpowersupplyunitisnotrequired.
Selectwhichoperatingpaneltouse.Assignfunctionalityaspermittedbyeachtype
ofoperatingpanel.
Topics
OperatingPanelMk2,page19
OperatingPanelMk3,page23
SimradSX90SoftwareReleaseNote

316866/R19
OperatingPanelMk2
TheMk2OperatingPanelisconnectedtotheProcessorUnitusinganEthernetcable.
TheOperatingPanelisprovidedwithabuilt-inpowersupply.
Details
UserSettingButtons
OntheMk2OperatingPanel,thefourbuttonsdedicatedforuser
settingsorpresentationmodesarelocatedthetopofthepanel.
SelectModeSelectiontospecifywhatyouwanttousethebuttons
for.Assignonepredenedusersettingorpresentationmodeto
eachbuttonontheOperatingPanel.
Tip
Beforeyoucanassigncustomusersettingstotheoperatingpanel,aselectionof
settingsmustbeavailablefromtheUserSettingsdialogbox.TheUserSettings
dialogboxislocatedontheMainmenu.
AnyusersettingselectedontheOperatingPanelisidentiedintheupperleft
corneroftheHorizontalview.TheidentifyingnumberreferstotheUserSetting
numberontheOperatingPanelpage.Clickonthetexttomakeitlarger .Clickone
moretimetorestoretheoriginalfontsize.
Updatedfunctionsanddialogboxes

20316866/R
RotarySwitchFunctions
TheMk2OperatingPanelisttedwiththreerotaryswitches.Theswitchesare
identiedwithnumbers.Eachswitchcanbeassignedafunctionrelatedtorange,
gain,bearingortilt.
UnderRotarySwitchOptions,assignonefunctiontoeachrotaryswitchonthe
OperatingPanel.Thefollowingfunctionscanbeassigned:
HorizontalRange
ThisistherangesettingintheHorizontalview.
VerticalRange
ThisistherangesettingintheVerticalview.
InspectionRange
ThisistherangesettingintheInspectionview.
HorizontalRange2
ThisistherangesettinginthesecondHorizontalviewwhena"dual"
presentationmodeisused.
VerticalRange2
ThisistherangesettinginthesecondV erticalviewwhena"dual"
presentationmodeisused.
PlaneRange
ThisistherangesettinginthePlaneview.
ActivePingRange
Thisistherangesettinginthecurrentlyactiveview.
ActivePingGain
Thisisthegainsettinginthecurrentlyactiveview
ActivePingBearing
Thisisthebearingsettinginthecurrentlyactiveview.
ActivePingTilt
Thisisthetiltsettinginthecurrentlyactiveview
SimradSX90SoftwareReleaseNote
Other manuals for Simrad SX90 Series
1
Table of contents
Other Kongsberg Fishing Equipment manuals