manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Konica Minolta
  6. •
  7. Measuring Instrument
  8. •
  9. Konica Minolta CM2500C User manual

Konica Minolta CM2500C User manual

Other Konica Minolta Measuring Instrument manuals

Konica Minolta CA-410 Series User manual

Konica Minolta

Konica Minolta CA-410 Series User manual

Konica Minolta CR-400 User manual

Konica Minolta

Konica Minolta CR-400 User manual

Konica Minolta CS-2000A - AUTRE User manual

Konica Minolta

Konica Minolta CS-2000A - AUTRE User manual

Konica Minolta cm-5 User manual

Konica Minolta

Konica Minolta cm-5 User manual

Konica Minolta CM-2600d User manual

Konica Minolta

Konica Minolta CM-2600d User manual

Konica Minolta T-10A User manual

Konica Minolta

Konica Minolta T-10A User manual

Konica Minolta CR-20 User manual

Konica Minolta

Konica Minolta CR-20 User manual

Konica Minolta CM-23d User manual

Konica Minolta

Konica Minolta CM-23d User manual

Konica Minolta CS-2000 User manual

Konica Minolta

Konica Minolta CS-2000 User manual

Konica Minolta CM-25cG User manual

Konica Minolta

Konica Minolta CM-25cG User manual

Konica Minolta MYIRO-1 User manual

Konica Minolta

Konica Minolta MYIRO-1 User manual

Konica Minolta CM-600d User manual

Konica Minolta

Konica Minolta CM-600d User manual

Konica Minolta CL-70F User manual

Konica Minolta

Konica Minolta CL-70F User manual

Konica Minolta FD-9 User manual

Konica Minolta

Konica Minolta FD-9 User manual

Konica Minolta CR-10 Plus User manual

Konica Minolta

Konica Minolta CR-10 Plus User manual

Konica Minolta CS-3000HDR User manual

Konica Minolta

Konica Minolta CS-3000HDR User manual

Konica Minolta VI-9I User manual

Konica Minolta

Konica Minolta VI-9I User manual

Konica Minolta CHROMA METER User manual

Konica Minolta

Konica Minolta CHROMA METER User manual

Konica Minolta CECF-9 User manual

Konica Minolta

Konica Minolta CECF-9 User manual

Konica Minolta CM-M6 User manual

Konica Minolta

Konica Minolta CM-M6 User manual

Konica Minolta SPECTRAMAGIC NX - User manual

Konica Minolta

Konica Minolta SPECTRAMAGIC NX - User manual

Konica Minolta VIVID 9i/VI User manual

Konica Minolta

Konica Minolta VIVID 9i/VI User manual

Konica Minolta RANGE7 User manual

Konica Minolta

Konica Minolta RANGE7 User manual

Konica Minolta CM-26dG User manual

Konica Minolta

Konica Minolta CM-26dG User manual

Popular Measuring Instrument manuals by other brands

Suaoki D40 user manual

Suaoki

Suaoki D40 user manual

Elster BK-G1.6 operating instructions

Elster

Elster BK-G1.6 operating instructions

Endress+Hauser Deltabar FMD71 technical information

Endress+Hauser

Endress+Hauser Deltabar FMD71 technical information

Duratool D03128 manual

Duratool

Duratool D03128 manual

Vega VEGAPULS 65 Quick setup guide

Vega

Vega VEGAPULS 65 Quick setup guide

Tonghui TH2618B Operation manual

Tonghui

Tonghui TH2618B Operation manual

Tenmars TM-801 user manual

Tenmars

Tenmars TM-801 user manual

MSR 145 user manual

MSR

MSR 145 user manual

TPS WP-82 manual

TPS

TPS WP-82 manual

PCB Piezotronics 003C30 Installation and operating manual

PCB Piezotronics

PCB Piezotronics 003C30 Installation and operating manual

Tenma 72-10465 manual

Tenma

Tenma 72-10465 manual

Endress+Hauser Proline Promag 50 Brief operating instructions

Endress+Hauser

Endress+Hauser Proline Promag 50 Brief operating instructions

Siemens SITRANS F Coriolis FCT030 Function manual

Siemens

Siemens SITRANS F Coriolis FCT030 Function manual

KLINGER CMF V Series instruction manual

KLINGER

KLINGER CMF V Series instruction manual

Keysight M8290A Getting started guide

Keysight

Keysight M8290A Getting started guide

Acterna MS1400 Operation manual

Acterna

Acterna MS1400 Operation manual

R&S ZPH manual

R&S

R&S ZPH manual

Datacolor ColorReader DC10-2 user guide

Datacolor

Datacolor ColorReader DC10-2 user guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

•Innovative 45/0 geometry optics
•Most lightweight, compact and rugged in its class
•360-740 nm wavelength range, 10 nm resolution
•Single-handed operation with "Navigation wheel"
•Free choice of power source : AC adapter or AA batteries
Color Data Software
Supports Windows®2000/XP
Model Spectrophotometer CM-2500c
Illumination/observation system 45/0 method (45°ring-shaped illumination, vertical viewing)
Light-receiving element Silicon photodiode array (dual 40 elements)
Spectral separation device Diffraction grating
Wavelength range 360 nm to 740 nm
Wavelength pitch 10 nm
Half bandwidth Approx. 10 nm
Reflectance range 0 to 175%, resolution: 0.01%
Light source 2 pulsed xenon lamps
Measurement time Approx. 1.5 seconds
Minimum interval between measurements
4 seconds
Battery performance Alkaline manganese: Approx. 1000 measurements, (at 23°C)
Measurement/illumination area ø7 mm/ø11 mm
Repeatability Colorimetric Value: Standard deviation within ∆E*ab 0.05
(Measurement conditions: White calibration platemeasured
30 times at 10-second intervals after white calibration was
performed)
Inter instrument agreement Within ∆E*ab 0.25
(Average for 12 BCRA Series II color tiles compared to values
measured with master body; at 23°C)
Measurement mode Single measurement/automatic averaging of multiple
measurements (auto mode: 3, 5, 8 times/manual mode)
Interface RS-232C standard
Observer 2/10 degrees (CIE 1931/2°, CIE 1964/10°)
Illuminant A, C, D50, D65, F2, F6, F7, F8, F10, F11, F12
(simultaneous evaluation is possible using two light sources)
Display data Spectral value/graph, colorimetric value, color difference
value/graph, PASS/FAIL result,
ASSESSMENTS (Except for Japanese mode)
Color space/colorimetric data
L*a*b*, L*C*h, CMC(1:1), CMC(2:1), CIE94, Hunter Lab, Yxy, Munsell,
XYZ, MI, WI (ASTM E313), WI (CIE), YI (ASTM E313/ASTM D1925),
ISO Brightness (ISO 2470), Density status A/T, WI/Tint (CIE), CIE00
Data memory
1700 pieces of data (as SCI/SCE 1 data) * 700 pieces of data in the “defined in COND.” mode.
* Total of the sample data and color difference target data
Pass/Fail judgment Tolerance for color difference
(Both box and elliptical tolerances can be set)
Power source 4 AA-size batteries or AC adapter
Size (W x H x D) 69 x 96 x 193 mm
Weight Approx. 670 g (without batteries)
Operating temperature/humidity range
5°C to 40°C, relative humidity 80% or less (at 35°C)
(*1) with no condensation
Storage temperature/humidity range
0°C to 45°C, relative humidity 80% or less (at 35°C)
with no condensation
In combination with the optional Color Data Software
SpectraMagic™NX, the CM-2500c becomes a complete
Quality Control and Color Management System. The software
allows you to configure the graphic and numerical layout
according to your needs, from ultra-simple Pass/Fail
assessments to more sophisticated analysis with spectral,
color and trend graphs. The unique Navigation function of
SpectraMagic™NX is another useful feature to assure fast
and easy use. To improve color communication with your
customers and suppliers, SpectraMagic™NX allows you to
insert digital pictures in printed reports–another unique feature.
System Diagram
Standard Accessories
Optional Accessories
AA-size
batteries (x4)
AC Adapter AC-A17
AC Adapter AC-A23 (for Korea)
Replacement clear cover(polyolefin)
Dust Cover CM-A152
RS-232C Cable
IF-A16
SpectraMagic™ NX
CM-S100w
Hard Case CM-A148
Dust Cover Set
CM-A149
Zero Calibration Box
CM-A32
White Calibration Plate
CM-A153
Personal Computer
(commercially available)
Specifications
SpectraMagic™NX (optional)
Certificate No : JQA-E-80027
Registration Date : March 12, 1997
Certificate No : YKA 0937154
Registration Date : March 3, 1995
CM-2500c
A breakthrough in 45/0 optics with
unprecedented accuracy & stability
SPECTROPHOTOMETER
Mac OS 10.3.7J illustrator 10J
CM-2500c(E)FRONT.ai 2006.11.17
A
G
M
C
P
K
Printed in Japan9242-4879-51
©2004 KONICA MINOLTA SENSING, INC. 4
SAFETY PRECAUTIONS
For correct use and for your safety, be sure to read the instruction
manual before using the instrument.
Always connect the instrument to the specified
power supply voltage. Improper connection
may cause a fire or electric shock.
Be sure to use the specified batteries. Using
improper batteries may cause a fire or electric
shock.
*1 Operating temperature/humidity range of products for North America : 5 to 40 °C, relative humidity 80% or less (at 31°C) with no condensation
• Specifications are subject to change without notice.
   
     
   
    
   
          
      
   
        
       
       
       

      
     
                                          
        
                                              
       
  
 
   
         
  
  

    
  

            
        
 
         
       
      
       
     
       
     
    
        
      
           
     
        
                         
       
      
        

     
      
   
           
    
�


 
  
 
 
  
 
 
                  
                
                  
               
                
               
     
                              
    
       
       
                               
      
      
      
        
       
      
        
            
       
           
            
        
           
  
       
         
         
            
 
     
       
       
    
 
•Innovative 45/0 geometry optics
•Most lightweight, compact and rugged in its class
•360-740 nm wavelength range, 10 nm resolution
•Single-handed operation with "Navigation wheel"
•Free choice of power source : AC adapter or AA batteries
Color Data Software
Supports Windows®2000/XP
Model Spectrophotometer CM-2500c
Illumination/observation system 45/0 method (45°ring-shaped illumination, vertical viewing)
Light-receiving element Silicon photodiode array (dual 40 elements)
Spectral separation device Diffraction grating
Wavelength range 360 nm to 740 nm
Wavelength pitch 10 nm
Half bandwidth Approx. 10 nm
Reflectance range 0 to 175%, resolution: 0.01%
Light source 2 pulsed xenon lamps
Measurement time Approx. 1.5 seconds
Minimum interval between measurements
4 seconds
Battery performance Alkaline manganese: Approx. 1000 measurements, (at 23°C)
Measurement/illumination area ø7 mm/ø11 mm
Repeatability Colorimetric Value: Standard deviation within ∆E*ab 0.05
(Measurement conditions: White calibration platemeasured
30 times at 10-second intervals after white calibration was
performed)
Inter instrument agreement Within ∆E*ab 0.25
(Average for 12 BCRA Series II color tiles compared to values
measured with master body; at 23°C)
Measurement mode Single measurement/automatic averaging of multiple
measurements (auto mode: 3, 5, 8 times/manual mode)
Interface RS-232C standard
Observer 2/10 degrees (CIE 1931/2°, CIE 1964/10°)
Illuminant A, C, D50, D65, F2, F6, F7, F8, F10, F11, F12
(simultaneous evaluation is possible using two light sources)
Display data Spectral value/graph, colorimetric value, color difference
value/graph, PASS/FAIL result,
ASSESSMENTS (Except for Japanese mode)
Color space/colorimetric data
L*a*b*, L*C*h, CMC(1:1), CMC(2:1), CIE94, Hunter Lab, Yxy, Munsell,
XYZ, MI, WI (ASTM E313), WI (CIE), YI (ASTM E313/ASTM D1925),
ISO Brightness (ISO 2470), Density status A/T, WI/Tint (CIE), CIE00
Data memory
1700 pieces of data (as SCI/SCE 1 data) * 700 pieces of data in the “defined in COND.” mode.
* Total of the sample data and color difference target data
Pass/Fail judgment Tolerance for color difference
(Both box and elliptical tolerances can be set)
Power source 4 AA-size batteries or AC adapter
Size (W x H x D) 69 x 96 x 193 mm
Weight Approx. 670 g (without batteries)
Operating temperature/humidity range
5°C to 40°C, relative humidity 80% or less (at 35°C)
(*1) with no condensation
Storage temperature/humidity range
0°C to 45°C, relative humidity 80% or less (at 35°C)
with no condensation
In combination with the optional Color Data Software
SpectraMagic™NX, the CM-2500c becomes a complete
Quality Control and Color Management System. The software
allows you to configure the graphic and numerical layout
according to your needs, from ultra-simple Pass/Fail
assessments to more sophisticated analysis with spectral,
color and trend graphs. The unique Navigation function of
SpectraMagic™NX is another useful feature to assure fast
and easy use. To improve color communication with your
customers and suppliers, SpectraMagic™NX allows you to
insert digital pictures in printed reports–another unique feature.
System Diagram
Standard Accessories
Optional Accessories
AA-size
batteries (x4)
AC Adapter AC-A17
AC Adapter AC-A23 (for Korea)
Replacement clear cover(polyolefin)
Dust Cover CM-A152
RS-232C Cable
IF-A16
SpectraMagic™ NX
CM-S100w
Hard Case CM-A148
Dust Cover Set
CM-A149
Zero Calibration Box
CM-A32
White Calibration Plate
CM-A153
Personal Computer
(commercially available)
Specifications
SpectraMagic™NX (optional)
Certificate No : JQA-E-80027
Registration Date : March 12, 1997
Certificate No : YKA 0937154
Registration Date : March 3, 1995
CM-2500c
A breakthrough in 45/0 optics with
unprecedented accuracy & stability
SPECTROPHOTOMETER
Mac OS 10.3.7J illustrator 10J
CM-2500c(E)FRONT.ai 2006.11.21
A
G
M
C
P
K
Printed in Japan9242-4879-51
©2004 KONICA MINOLTA SENSING, INC. 4
SAFETY PRECAUTIONS
For correct use and for your safety, be sure to read the instruction
manual before using the instrument.
Always connect the instrument to the specified
power supply voltage. Improper connection
may cause a fire or electric shock.
Be sure to use the specified batteries. Using
improper batteries may cause a fire or electric
shock.
*1 Operating temperature/humidity range of products for North America : 5 to 40 °C, relative humidity 80% or less (at 31°C) with no condensation
• Specifications are subject to change without notice.