238-54715-00A REV 8/22 Doc# 11104A

Installation
Table of Contents
Pre-Installation Information.......................................................................................................................................................... 3
Storage Instructions...................................................................................................................................................................... 4
Packaging ...................................................................................................................................................................................... 4
Transportation .............................................................................................................................................................................. 5
Mounting Heater........................................................................................................................................................................... 6
Plumbing Installation .................................................................................................................................................................... 7
Start Up ......................................................................................................................................................................................... 9
DANGER
Tip over hazard. System can crush you resulting in serious injury or death. Read and follow precautions in this installation
manual that accompanied the heater for instructions on how to safely transport and mount.
WARNING
Read this manual BEFORE using this equipment. Failure to read and follow all safety and user information could result in
death, serious personal injury, burns, property damage, or damage to the equipment. Keep this manual for future reference.
Failure to comply with proper installation and maintenance instructions could contribute to the heater’s failure.
A qualified plumber or electrician should install and service this system. Install system according to these instructions and in
compliance with national and local codes.
For safe operation of the heater, observe all warning labels as indicated.
Water heater system under pressure. DO NOT open enclosure while in operation. These heaters should never be used to
provide “anti-scald” or “anti-chill” service.
Hazardous voltage inside enclosure may result in serious burns or death. Disconnect power supply before performing any
work in the enclosure.
Failure to ground this system may result in death or serious injury.
Make sure that all water supply lines have been flushed and then completely turned off before beginning installation. Debris
in supply lines can cause valves to malfunction.
CAUTION
Hot pipes! DO NOT touch. May cause burns.
NOTICE
These heaters DO NOT provide protection from supply or outlet pipe freezing even when equipped with ENHT option(s).
Consult local building and plumbing codes prior to installation. Should these codes differ from the information in the
manual, follow the local codes. Inquire with governing authorities for additional local requirements.
Regular checking and cleaning of the heater’s internal components and check stops is necessary for maximum life and proper
product function. Periodic inspection and yearly maintenance by a licensed contractor is required. Corrosive water
conditions, and/or unauthorized adjustments or repairs could render the heater ineffective for its intended service.
Frequency of cleaning and inspection depends upon local water conditions. For heaters with adjustable output
temperatures, check and adjust as needed at initial installation and on a quarterly basis.
IMPORTANT
Read this entire installation manual to ensure proper installation. When finished with the installation, file this manual with
the owner or maintenance department. Compliance and conformity to local codes and ordinances is the responsibility of the
installer. Product warranties may be found under "Resources" on our website at
www.laars.com.
Separate parts from packaging and make sure all parts are accounted for before discarding any packaging material. If any
parts are missing, do not begin installation until you obtain the missing parts.
2

Installation
Pre-Installation Information
General Information
The N Series Skid (C Series) Systems provide instant and precise temperature-controlled hot water. Pre-assembled and
pre-piped with two Laars Tankless Water Heaters mounted back-to-back and secured to a heavy-duty steel skid. These
systems can be used for most commercial and industrial hot water applications. To ensure proper performance, install
the heater according to the following installation instructions and in compliance with applicable national and local
codes.
See Maximum Temperature Rise Specifications chart. Contact a Laars representative for further information on available
flow devices.
Operation and Setup
N Series Skid (CSeries) heaters supply an unlimited amount of hot water with specific flow and temperature rise
capabilities. These heaters are energy efficient, reliable, and provide optimum performance in the most demanding
applications.
Application Specific Requirements
The N Series Skid (CSeries) can be used in many different applications that require custom tuning for specific
applications to maximize performance of the heater.
For use in a re-circulation loop, the incoming loop temperature should not exceed 140°F (60°C).
For applications utilizing quick close valves or solenoid valves, it is important to install a hammer arrestor or surge tank
close to the point of use to absorb pressure spikes.
ASME CERTIFICATION: Please verify if your State Boiler Code requires ASME Certification and that you have the
proper heater to meet your code requirements prior to installation.
Installation Considerations
Maximum operating pressure: 150 psi (10 bar)
ASME maximum operating pressure: 160 psi (11 bar)
Standard flow activation: 3.0 gpm (11.4 lpm) with minimum inlet pressure of 30 psi (2.1 bar)
Certifications
Certified by ETL to UL499, CSA22 2 No 88 and NFPA 496 (for hazardous locations) and third party certified to NSF/ANSI
372. Heaters are compliant with NEC/NFPA 70 and Canadian Electrical Code C22.1.
WARNING For safe operation of the heater, observe all the warning labels as indicated.
3

Installation
Storage Instructions
NOTICE! Keep Electric Tankless Water Heaters stored in original packaging until installation.
Recommended storage criteria:
Store Electric Tankless Water Heaters where temperatures exceed 35°F (2°C) at all times.
Indoor storage is recommended.
Minimize excessive on-site transport to reduce risk of shock and impact damage.
Alternate storage:
If in the original crate, Electric Tankless Water Heaters will withstand outside storage for approximately 1 month in most
climates. The crate may not be capable of protecting the heater if left outside longer than this time frame.
If the Electric Tankless Water Heater is stored in an outdoor environment, care should be taken to protect the heaters
from:
• Rain or other falling precipitation via tarp or other waterproof media
• Runoff and accumulation of groundwater from any source that may exceed 1 inch (25mm).
NOTICE! For heaters with ENHT freeze protection option(s): External plumbing to the heater(s) on an N Series Skid
(C Series) are not freeze protected from the factory and on-site installation of freeze protection is the sites
responsibility.
NOTICE! For heaters with ENHT freeze protection option(s): If the heater is stored where the temperature could
fall below 45°F (7°C), the heater must be powered immediately after hydro testing to ensure internal freeze
protection components are activated. Once the heater is installed and the on-site plumbing has been hydro tested,
the power supply must remain constant until the risk of freeze is eliminated. If this is not possible, the heater must
be drained. Freezing of the heater can cause serious damage. Follow notes in Start Up Check List section following
an electrical lockout/tagout procedure.
Packaging
Crates are constructed from 3/4" (19mm) OSB.
Crate dimensions approx: 48" x 60" x 100" (1219mm x 1524mm x 2540mm)
Crates should not be stacked.
Safety issues related to packaging:
•Product should be transported with the care associated to packages labeled “FRAGILE” even if packaging is not
marked accordingly.
•Standard safety procedures for forklift transport and large items less than 2000lbs (907 kgs) should always be
followed.
•When stored, crate must be supported in entirety of its length and width.
4

Installation
1Transporting the Skid System
Unless otherwise requested, Laars Skid Systems are transported within the continental United States and
Canada via commercial truck.
Each skid system will be accompanied by document packaging that includes the installation instructions.
Store skid system documents for reference.
NOTICE! Check the load ratings on equipment intended to be used to transport the system
Remove the shipping crate top and sides.
Locate the forklift tubes on the skid
system and lift for transport
NOTICE! During transit, transport close to the
ground. Use all standard safety measures and
precautions prior to and during transit.
NOTICE! Use caution when transporting.
Always use proper lifting techniques. Weight
distribution is unbalanced and the product is
susceptible to tipping which will result in
damage to the product.
Secure heater by bolting each leg to the
floor using 3/8” (10mm) anchor bolts.
5

Installation
2Mounting
intenance. A minimum of 36" (914mm) from the front of
For best results, install system as close as possible to the point of use
Long pipe runs are not recommended. A heat loss of 1°F for every 10ft (3 meters) of uninsulated pipe can occur..
When determining a mounting location, ensure accessibility of the cabinet enclosure door and other plumbing for service and
maintenance of the cabinet enclosure and a minimum of 48" (1219mm) above the top of the cabinet enclosure is needed.
Verify skid system is in final installation location.
Secure the base to concrete at the
(4) mounting locations using suitable concrete anchoring
devices with expansion sleeves (supplied by installer) .
The skids use 3/8" (10mm) or 1/2" (13mm) mounting
hardware/anchoring devices. Install anchors per
manufacturer recommendation. Review and follow all
local codes and ordinances that regulate anchoring.
6

Installation
3 Plumbing Installation
Components Included:
•(10) Union 2"
•(2) Pressure and Temperature Relief Valve (150 psi/10 bar)
•(2) Gate or Ball Type Valves
Elbows, nipples and fittings as needed
Components included in the N Series Skid (C Series) Systems are different from the standard
N Series Heater.
See dimensional drawings for reference and suggested installation configuration.
Failure to install proper filtration may result in a flow sensor malfunction
7

Installation
8
68¼"(1734) 69¼"(1759)
80¼"(2035) 81¼"(2065)
80¼"(2035)) 81¼"(2065)
N Series Skid (C Series) Dimensions
3 Plumbing Installation (Cont.)

4Start Up Check List
System is set in a vertical, level, and upright position with the outlet located at the top.
Skid is mounted to the
ground by (4) 3/8" or 1/2" anchoring devices.
Verify pressure and temperature relief valve is installed on water outlet immediately following the union.No
valve or restriction is between the relief valve and the system or the relief valve and drain. Shutoff valve is
installed after pressure and temperature relief valve on outlet if required by local or national plumbing codes.
If the hot water process is not at the highest point in the plumbing loop, then an automatic air vent valve
must be added at the highest point in the system plumbing loop to eliminate trapped air.
9
Installation

www.laars.com
Technical Support
Website
Email
(603) 335-6300 or Toll Free (800) 900-9276
www.laars.com
For field service, please contact your professional installer or local Laars sales representative.
United States
This manual suits for next models
7
Table of contents
Other Laars Heater manuals
Popular Heater manuals by other brands

Empire
Empire VEP-80L Installation and owner's guide

EQUATION
EQUATION HELLA User and maintenance manual

North American
North American 3510 operation & maintenance

Maestro
Maestro MR 920 owner's manual

ReddyHeater
ReddyHeater IWH16NLTD OWNER'S OPERATION AND INSTALLATION MANUAL

EUROM
EUROM OUTDOOR HEATPANEL RC manual