lancer 2300 Series User manual

ABOUT THIS MANUAL
This booklet is an integral and essential part of the product and
should be handed over to the operator after the installation and
preserved for any further consultation that may be necessary.
Please read carefully the guidelines and warnings contained
herein as they are intended to provide the user with essential
information for the continued safe use and maintenance of the
product. In addition, it provides GUIDANCE ONLY to the user on
the correct services and site location of the unit.
BEFORE GETTING STARTED
Each unit is tested under operating conditions and is thoroughly
inspected before shipment. At the time of shipment, the carrier
accepts responsibility for the unit. Upon receiving the unit,
carefully inspect the carton for visible damage. If damage exists,
have the carrier note the damage on the freight bill and le a
claim with carrier. Responsibility for damage to the dispenser lies
with the carrier.
IMPORTANT SAFETY INSTRUCTIONS
The installation and relocation, if necessary, of this product must be carried out by qualied personnel with
up-to-date safety and hygiene knowledge and practical experience, in accordance with current regulations.
LANCER PN: 28-3023/01
Revision: February 2019
®
2300
FOR QUALIFIED INSTALLER ONLY. This basic Installation Sheet is an initial release. If a complete
Operations Manual (for the unit being installed) is required or needed, please refer to the Lancer web
site (lancercorp.com) for immediate access, or for your convenience, scan this QR code with a mobile
device (app required) for immediate access to other Technical Documents and alternative translations
(if available) pertaining to this unit. Contact Lancer Customer Service for assistance as required.
The dispenser is for indoor use only. This unit is not a toy. Children should not be supervised not to play with appliance. It should
not be used by children or inrm persons without supervision. This appliance is not intended for use by persons (including children)
with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given
supervision or instruction concerning use of the appliance by a person responsible for their safety. Cleaning and user maintenance
shall not be performed by children without supervision. The min/max ambient operating temperature for the dispenser is 40°F to
90°F (4°C to 32°C). Do not operate unit below minimum ambient operation conditions. Should freezing occur, cease operation of
the unit and contact authorized service technician. Service, cleaning and sanitizing should be accomplished only by trained
personnel. Applicable safety precautions must be observed. Instruction warnings on the product being used must be followed.
! Intended Use
Ice Cooled Drop-In Series 2300
Standard Performance
LANCER INSTALLATION GUIDE
Check the dispenser name plate label, located behind the splash plate, for the correct electrical requirements of unit. Do not plug
into a wall electrical outlet unless the current shown on the serial number plate agrees with local current available. Follow all local
electrical codes when making connections. Each dispenser must have a separate electrical circuit. Do not use extension cords with
this unit. Do not ‘gang’ together with other electrical devices on the same outlet. The key-switch does not disable the line voltage to
the transformer primary. Always disconnect electrical power to the unit to prevent personal injury before attempting any internal
maintenance. The resettable breaker switch should not be used as a substitute for unplugging the dispenser from the power source
to service the unit. Only qualied personnel should service internal components of electrical control housing. Make sure that all
water lines are tight and units are dry before making any electrical connections!
F Electrical Warning
• WARNING: Carbon Dioxide (CO2) is a colorless, noncombustible gas with a light pungent odor. High percentages of CO2may
displace oxygen in the blood.
• WARNING: Prolonged exposure to CO2can be harmful. Personnel exposed to high concentrations of CO2gas will experience
tremors which are followed by a loss of consciousness and suocation.
• WARNING: If a CO2gas leak is suspected, immediately ventilate the contaminated area before attempting to repair the leak.
• WARNING: Strict attention must be observed in the prevention of CO2gas leaks in the entire CO2and soft drink system.
5 Carbon Dioxide (CO2)

2
Provide an adequate potable water supply. Water pipe connections and xtures directly connected to a potable water supply must
be sized, installed, and maintained according to federal, state, and local laws. The water supply line must be at least a 3/8 inches
(9.525 mm) pipe with a minimum of 25 psi (0.172 MPa) line pressure, but not exceeding a maximum of 50 psi (0.345 MPa).
Water pressure exceeding 50 psi (0.345 MPa) must be reduced to 50 psi (0.345 MPa) with the provided pressure regulator. Use
a lter in the water line to avoid equipment damage and beverage o-taste. Check the water lter periodically, as required by local
conditions. The water supply must be protected by means of an air gap, a back-ow prevention device or another approved method
to comply with NSF standards. A leaking inlet water check valve will allow carbonated water to ow back through the pump when it
is shut o and contaminate the water supply. Ensure the back-ow prevention device complies with ASSE and local standards. It is
the responsibility of the installer to ensure compliance.
! Water Notice
SPECIFICATIONS
Your Service Agent:
Service Agent Telephone Number:
Serial Number:
Model Number:
INSTALLATION
This manual was developed by the Lancer Corporation as a reference for the owner/operator and installer of this
dispenser. Please read this guide before installation and operation of this dispenser. If service is required please call your
Lancer Service Agent or Lancer Customer Service. Always have your model and serial number available when you call.
READ THIS MANUAL
DIMENSIONS
Width: 23.0 inches (584 mm)
Depth: 23 inches (584 mm)
Height: 40.6 inches (1031.24 mm)
COUNTER CUT-OUT
Width: 23.25 inches (591 mm)
Depth: 23.25 inches (591 mm)
PLAIN WATER SUPPLY
Min Flowing Pressure: 20 psi (0.138 MPa)
Max Flowing Pressure: 50 psi (0.345 MPa)
CARBON DIOXIDE (CO2) SUPPLY
Min Pressure: 90 psi (0.621 MPa)
Max Pressure: 110 psi (0.758 MPa)
FITTINGS
Soda Water Inlet: 3/8 inch barb
Brand Syrup Inlets: 3/8 inch barb
WEIGHT
Shipping: 260 lbs (118 kg)
Operating (w/ Ice): 206 lbs (93 kg)
Ice Capacity: 100 lbs (45 kg)
ELECTRICAL
115 VAC / 60 Hz
This unit emits a sound pressure level below 70 dB
ICDI - 2300
Unpack the Dispenser
1. Set shipping carton upright on the oor then cut package
banding straps and remove.
2. Open top of carton and remove interior packaging.
3. Lift carton up and o of the unit.
4. Remove accessory kit and loose parts from ice compartment.
If unit is to be transported, it is advisable to leave the
unit secured to the plywood shipping base.
NOTE
To avoid personal injury or damage, do not attempt to
lift a unit without help. For heavier units, use of a
mechanical lift may be appropriate. Units are equipped
with automatic agitation. The unit may activate
unexpectedly. Do not place hands, or foreign objects
into the ice storage compartment. Unplug dispenser
from the power source, when unit is being serviced,
cleaned, or sanitized.
! WARNING

3
Dispenser Installation
The dispenser should only be installed in a location
where it can be overseen by trained personnel
NOTE
1. Select a level, well ventilated location that is in close
proximity to a properly grounded electrical outlet, within
ve (5) feet (1.5 m) of a drain, a water supply that meets
the requirements shown in the Specications section found
on pages 4-6, and away from direct sunlight or overhead
lighting
2. The selected location should be able to support the weight
of the dispenser and ice after the counter cut out is made.
Total weight (with ice) for this unit could exceed 400 pounds
(181.4 kg).
3. If installed directly on the counter, unit must be sealed to the
counter-top with an FDA approved sealant.
4. If installed using the free-standing conversion kit (Lancer PN:
84-0058), unit must use the legs provided.
5. Select a location for the remote carbonator, syrup pumps,
CO2 t a n k , s y r u p c o n t a i n e r s , a n d w a t e r l t e r ( r e c o m m e n d e d ) .
NSF listed units must be sealed to the counter or use
legs provided.
NOTE
Selecting Counter Location
The installation, and relocation if necessary, must
be carried out by qualied personnel with up-to-date
knowledge and practical experience, in accordance with
current regulations.
NOTE
1. Inspect the location where the unit is to be installed and if
necessary make counter cut-out, (See Specications section
on page 2 or Cut-out Diagrams on page 11 for counter cut-
out dimensions).
Counter cut-out must be accurate, according to unit
specications.
! ATTENTION
2. Once the counter cut-out is made, lower the unit into the
counter and seal the rim to the counter using an approved
silicone sealant.
3. If using freestanding conversion kit, install per kit instructions
then insert and seal unit to freestanding frame. Position
freestanding unit in designated location.
4. Route appropriate tubing from the water source to the soda
water inlets at the front of the unit.
5. Install tee tting to water line split water line between the left
and right side soda water inlets.
6. Install “U” tting to each soda water line to complete soda
water line manifold.
A
B
CA. “U” Fitting
B. Line to Tee Fitting
C. Line to Soda/Water Inlet
A
B
D
C
A. Tee Fitting
B. Line to Water Source
C. Line to Left Soda Inlets
D. Line to Right Soda Inlets

4
If necessary, shipping riser can be shifted to the center
of the bottom plate for ease of installation.
NOTE
9. Connect tubing to water source then ush water lines to
check for leaks.
10. Install water regulator and lter to water line and, if
necessary, install water booster (Lancer PN MC-163172)
between water supply and the unit.
11. Using tubing cutters, cut soda water line and install remote
carbonator per manufacturer’s specications.
12. Install a shut-o valve in the water line feeding the
carbonator pump deck.
A
BA. Tubing
B. Soda Water Inlet
7. Route the soda water line manifold through the shipping riser
legs in the back of the unit.
8. Connect tubing of soda water line manifold to appropriate
inlets, at the front of the unit, using oetiker pliers and ttings,
(see Plumbing Diagrams on the front of the unit or on pages
10-11 for reference).
13. Route appropriate tubing from the syrup pump location
through the shipping riser legs in the back of the unit (See
Step 7).
14. Connect each syrup line to appropriate syrup inlet in the front
of the unit (see Plumbing Diagrams on the front of the unit or
on pages 10-11 for reference).
If installing a 6-Valve unit, two of the syrup lines will be
capped. DO NOT remove the caps from the two syrup
lines. See plumbing diagram for reference.
! ATTENTION
15. Connect each syrup line to individual syrup pump outlet
tting.
16. Install BIB (bag in box) connectors to the syrup supply line
tubing.
A. Syrup Supply Line
B. BIB Connector
C. BIB Syrup Container
A B
C
Use proper connector for syrup manufacturer
! ATTENTION
A. Syrup Supply Line
B. BIB Connector
AB
17. Attach BIB connectors on syrup supply line to BIB. Repeat
for each syrup line/pump.

5
DO NOT PLUG UNIT INTO GROUNDED ELECTRICAL
OUTLET AT THIS TIME. Make sure that all water lines
are tight and unit is dry before making any electrical
connections
! WARNING
Drain line must be insulated with a closed cell
insulation. Insulation must cover the entire length of
the drain hose, including ttings. The drain should be
installed in such a manner that water does not collect
in sags or other low points, as condensation will form.
! CAUTION
Pouring hot water down the drain may cause the Drain
Tube to collapse. Allow only warm or cold water to
enter the Drain Tube. Pouring coee, tea, or other
similar substances down the drain may cause the
Drain Tube to become clogged.
! ATTENTION
19. Install PVC drain tting to back left ice bin drain line.
20. Install drain lines to both front and back drain ttings then tee
the two drain lines together at the back of the unit.
21. Route tee’d drain hose to designated open type drain.
22. Install power supply assembly to bottom plate of free
standing conversion kit or under counter.
23. Route the power supply cord to a grounded electrical outlet
of the proper voltage and amperage rating.
18. Install threaded drain tting (PN: 01-1612), included in
accessory kit, to front drain line. Installing CO2Supply
1. Connect high pressure CO2regulator assembly to CO2
cylinder or bulk system.
- Thread regulator nut on to tank, then
tighten nut with wrench
A. CO2Regulator
B. Outlet
C. Wrench
D. CO2 Supply
A
B
C
D
Before installing regulator, assure that a seal (washer
or o-ring) is present in regulator attachment nut.
! ATTENTION
A. CO2Regulator
B. Line to Syrup Pumps
& Remote Carbonator
A
B
A dedicated CO2regulator is required to supply the
carbonator as well as to all syrup pumps.
! ATTENTION
2. Connect appropriate CO2tubing to inlet on regulator then
route tubing from the CO2regulator to the remote
carbonator and CO2regulator at syrup pumps. Use a tee
tting if necessary.
DO NOT TURN ON CO2SUPPLY AT THIS TIME
! WARNING
3. Route appropriate tubing for CO2from CO2regulator at syrup
pumps to all syrup pump CO2inlets.

6
If regulator does not utilize a knob, use a wrench to
loosen the lock nut then a screwdriver to back out the
screw and close the regulators.
NOTE
A. CO2Regulator
B. Regulator Knob
A
B
4. Turn the knob on the CO2regulator, at the source, all the
way to the left (counterclockwise) to close the regulator.
Repeat for CO2regulator at the syrup pumps.
A. CO2Regulator
B. Screwdriver
C. Loosened Lock Nut
D. Regulator Adjustment
Screw
A
B
C
D
A. CO2Regulator
B. Wrench
C. Lock Nut
A
C
B
Dispenser Setup
1. Turn on water source.
2. Place enough ice in the ice bin to ll approximately 1/2 of the
bin before plugging in the unit.
3. Connect unit power cord to grounded electrical outlet.
Failure to disconnect the motor power supply will
damage the carbonator motor, the pump and void the
warranty.
! ATTENTION
The dispenser must be properly electrically grounded
to avoid serious injury or fatal electrical shock. The
power cord has a three-prong grounded plug. If a
three-hole grounded electrical outlet is not available,
use an approved method to ground the unit. Follow all
local electrical codes when making connections. Each
dispenser must have a separate electrical circuit. Do
not use extension cords. Do not connect multiple
electrical devices on the same outlet.
! WARNING
7. Turn on CO2at the source then turn the knob on the CO2
regulator at source to the right (clockwise) until regulator
reads 105 psi (0.724 MPa).
4. Open the pressure relief valve, located on the remote
carbonator, by ipping up on the valve cap lever. Hold open
until water ows from the relief valve then close (ip down)
the relief valve.
A. Pressure Relief Valve
A
5. Activate each valve to ensure a good ow of water is
achieved.
6. Ensure carbonator pump deck is turned OFF before turning
on CO2.
DO NOT ADJUST CO2REGULATOR AT SYRUP PUMPS
AT THIS TIME. Make sure carbonated water ow rate is
set before adjusting regulator at syrup pumps.
! ATTENTION
A. CO2Regulator
B. Regulator Knob
A
B

7
A. Regulator Adjustment Screw
B. Adjust to 105 psi (0.724 MPa)
C. Wrench
A
B
C
8. Activate each valve until gas-out.
9. Plug in the remote carbonator pump deck, if not already
done so, and turn the switch to the ON position.
10. Activate each valve until the carbonator pump comes on.
Release the button, allow carbonator to ll and stop. Repeat
this process until a steady ow of carbonated water is
achieved.
The pump deck has a 3 minute timeout feature. If the
timeout occurs, turn the deck OFF then ON by ipping
the switch on the control box.
NOTE
To check for CO2leaks, close the valve on the CO2cyl-
inder and observe if the pressure to the system drops
with the cylinder valve closed for ve minutes. Open
the cylinder valve after check.
NOTE
If regulator does not utilize a knob, use a screwdriver
to adjust regulator to 105 psi (0.724 MPa) then tighten
lock nut with wrench.
NOTE
Ensure there is ice on the cold plate and the lines are
cold before attempting to set the ow rates on the
valves. The drink temperature should be no higher than
40°F (4.4°C) when ow rates are set.
NOTE
AB
Increase Decrease
C
E
A. Flow Control, Water
B. Flow Control, Syrup
C. Nozzle (Diuser inside)
D. Retainer Clip
E. Soda Lever
D
11. Remove the Valve ID Panel for the rst valve.
A. Valve ID Panel
B. Valve Cover
A
B
12. Use a Lancer ratio cup to verify water ow rate (5 oz. in 4
sec.). Use a screwdriver to adjust if needed.
13. Repeat Step 12 until ow rate is correct.
14. Repeat Steps 11 - 13 for remaining valves.
Adjust Syrup/Water Ratio
1. Turn the knob on the CO2regulator at the syrup pumps to
the right (clockwise) until regulator reads 65 psi (0.448 MPa).
A
B
C
A. Nozzle
B. Diuser
C. Soda Lever
If regulator does not utilize a knob, use a screwdriver
to adjust regulator to 65 psi (0.448 MPa) then tighten
lock nut with wrench.
NOTE
A. CO2Regulator
B. Regulator Knob
C. Line to Syrup Pumps
D. Line from CO2Source
A
B
C
D
2. Remove nozzle on rst valve by twisting counter clockwise
and pulling down

8
AB
A. Syrup Separator
B. Soda Lever
A
B
C
A. Syrup Separator
B. Ratio Cup
C. Verify Soda/
Water Level
5. Using a Lancer ratio cup, activate the valve and capture a
sample. Verify that the syrup level is even with the water
level. Use a screwdriver to adjust if needed.
6. Remove syrup separator and reinstall nozzle. Replace valve
ID cover.
7. Repeat steps 2-6 for each valve.
3. Remove the diuser by pulling down.
4. Install Lancer (yellow) syrup separator (PN 54-0031) in place
of nozzle.
Lancer equipment (new or reconditioned) is shipped from the factory cleaned and sanitized in accordance with NSF
guidelines. The operator of the equipment must provide continuous maintenance as required by this manual and/or
state and local health department guidelines to ensure proper operation and sanitation requirements are maintained.
The cleaning procedures provided herein pertain to the Lancer equipment identied by this manual. If other equipment
is being cleaned, follow the guidelines established by the manufacturer for that equipment.
Cleaning should be accomplished only by trained personnel. Sanitary gloves are to be used during cleaning operations.
Applicable safety precautions must be observed. Instruction warnings on the product being used must be followed.
GENERAL INFORMATION
• Use sanitary gloves when cleaning the unit and observe all applicable safety precautions.
• DO NOT use a water jet to clean or sanitize the unit.
• DO NOT disconnect water lines when cleaning and sanitizing syrup lines, to avoid contamination.
• DO NOT use strong bleaches or detergents; These can discolor and corrode various materials.
• DO NOT use metal scrapers, sharp objects, steel wool, scouring pads, abrasives, or solvents on the dispenser.
• DO NOT use hot water above 140° F (60° C). This can damage the dispenser.
• DO NOT spill sanitizing solution on any circuit boards. Insure all sanitizing solution is removed from the system.
! ATTENTION
CLEANING AND SANITIZING
Cleaning Solution
Mix a mild, non-abrasive detergent (e.g. Sodium Laureth
Sulfate, dish soap) with clean, potable water at a temperature
of 90°F to 110°F (32°C to 43°C). The mixture ratio is one ounce
of cleaner to two gallons of water. Prepare a minimum of ve
gallons of cleaning solution. Do not use abrasive cleaners or
solvents because they can cause permanent damage to the unit.
Ensure rinsing is thorough, using clean, potable water at a
temperature of 90°F to 110°F. Extended lengths of product lines
may require additional cleaning solution.
Sanitizing Solution
Prepare the sanitizing solution in accordance with the
manufacturer’s written recommendations and safety guidelines.
The type and concentration of sanitizing agent recommended in
the instructions by the manufacturer shall comply with 40 CFR
§180.940. The solution must provide 100 parts per million (PPM)
chlorine (e.g. Sodium Hypochlorite or bleach) and a minimum of
ve gallons of sanitizing solution should be prepared.

9
If a powder sanitizer is used, dissolve it thoroughly with hot water prior to adding to the syrup system. Ensure
sanitizing solution is removed from the dispenser as instructed. Avoid getting sanitizing solution on circuit boards. Do
not use strong bleaches or detergents; these can discolor and corrode various materials. Do not use metal scrapers,
sharp objects, steel wool, scouring pads, abrasives, or solvents on the dispenser. Do not use hot water above 140° f
(60° c). This can damage the dispenser.
! WARNING
Following sanitation, rinse with end-use product until
there is no aftertaste. Do not use a fresh water rinse.
This is a NSF requirement. Residual sanitizing solution
left in the system creates a health hazard.
! CAUTION
Cleaning and Sanitizing Nozzles
1. Disconnect power, so as to not activate valve while cleaning.
2. Remove merchandiser to reveal valves.
3. Remove nozzle by twisting counter clockwise and pulling
down.
4. Remove diuser by pulling down.
5. Rinse nozzle and diuser with warm water.
6. Wash nozzle and diuser with cleaning solution then
immerse in sanitizing solution and let sit for fteen (15)
minutes.
7. Set nozzle and diuser aside and let air dry. DO NOT rinse
with water after sanitizing.
8. Reconnect diuser and nozzle.
9. Connect power.
10. Taste the drink to verify that there is no o-taste. If o-taste
is found, ush syrup system again.
A
B
C
A. Nozzle
B. Diuser
C. Soda Lever
Cleaning and Sanitizing Syrup Lines - Bag in Box
1. Disconnect syrup lines from BIB’s
2. Place syrup lines, with BIB connectors, in a bucket of warm
water.
3. Activate each valve to ll the lines with warm water and ush
out syrup remaining in the lines.
4. Prepare Cleaning Solution described on previous page.
Following sanitation, rinse with end-use product until
there is no aftertaste. Do not use a fresh water rinse.
This is a NSF requirement. Residual sanitizing
solution left in the system creates a health hazard.
! CAUTION
1. Prepare cleaning solution and sanitizing solution according
to the corresponding sections on the previous page.
2. Using the cleaning solution and a clean soft cloth, wash
down the sides of the ice bin and the surface of the
aluminum casting.
3. Using clean, potable water, thoroughly rinse away the
cleaning solution from the sides and surface of the casting.
4. Using plastic sanitary gloves, soak a white cotton gauze
cleaning rag in the sanitizing solution and wipe all surfaces
in the ice compartment.
The ice bin compartment of the dispenser should be
thoroughly cleaned and sanitized at least once every
month.
NOTE
5. Sanitizing of the ice compartment is complete. Rell with ice.
A fresh water rinse cannot follow sanitation of
equipment. Purge only with the end use product. This is
an NSF requirement.
! CAUTION
Cleaning and Sanitizing Ice Bin Compartment
5. Place syrup lines, with BIB connectors, into cleaning
solution.
6. Activate each valve until lines are lled with cleaning
solution then let stand for ten (10) minutes.
7. Flush out cleaning solution from the syrup lines using clean,
warm water.
8. Prepare Sanitizing Solution described on previous page.
9. Place syrup lines into sanitizing solution and activate each
valve to ll with sanitizer. Let sit for ten (10) minutes.
10. Reconnect syrup lines to BIB’s and draw drinks to ush
solution from the dispenser.
11. Taste the drink to verify that there is no o-taste. If o-taste
is found, ush syrup system again.

10
ILLUSTRATIONS & DIAGRAMS
2300, 6 Valve, Standard Plumbing Diagram
2300, 8 Valve, Standard Plumbing Diagram
2300, 10 Valve, Standard Plumbing Diagram

11
2300, 6 Valve, Standard Tower Plumbing Diagram 2300, 8 Valve, Standard Tower Plumbing Diagram
2300 Standard Wiring Diagram
L L L L L R R R R R
MARQUEE
OPTIONAL
Right Side
Bin Switch Right Side
Key Switch
LEFT BANK OF VALVES RIGHT BANK OF VALVESCENTER BANK OF VALVES
Right Side
Power Supply
Left On
Top
Right On
Bottom
Key Switch
Orientation
Wall
Outlet
1
2
3
45
67
8910
Left Side
Bin Switch
Left Side
Power Supply
Wall
Outlet
Left Side
Key Switch
MF
M
F
F M
M
F
MF
F
M
MF
M
F
M
F
Lancer PN: 06-4039

Lancer Corp.
800-729-1500
Technical Support/Warranty: 800-729-1550
lancercorp.com
(CUTOUT)
23 1/4" (591 mm)
25.25" (641 mm)
(CUTOUT)
23 1/4"
(591 mm)
25.5"
(648 mm)
2300 Counter Cutout Diagram
To prevent possible harm to the environment from improper disposal, recycle the unit
by locating an authorized recycler or contact the retailer where the product was
purchased. Comply with local regulations regarding disposal of the refrigerant and
insulation.
Dispenser Disposal