Breastmilk Expression Set Item Number
aDiaphragm Cap P53410
bDiaphragm P53402
cComfortFit® Breast Cushion (25mm) P54103
dBreast Cushion Body P53454
eWhite Valve P53401
f160ml (5oz) Bottle P53451
gSealing Cap P53461
Breast Pump Parts and Accessories Item Number
hSilicone Tube (800mm) P54100
iPump Connector P54106
jTeat Cover P53462
kNaturalWave® Slow Flow Teat P75900
lTeat Collar P53463
mAC Adapter P53470
2.2 Cleaning Instructions
Unless otherwise instructed by your health
care provider, follow these instructions.
DO NOT wash tubing or connector.
Before First Use
•Always wash and dry hands thoroughly with soap and
water before handling the Breastmilk Expression Set.
•Disassemble the Breastmilk Expression Set and place
parts in a large pot.
•Cover the parts in water making sure there is room for
all of the parts to float freely in the pot.
•Bring the water to the boil and allow the parts to a
boil for 5 minutes.
•After boiling remove the parts from the pot with tongs
and place the pieces neatly on a clean paper towel or
in a clean drying rack and allow them to air dry.
•Allow the parts to dry completely before assembly and
use. Partially dried parts may aect the operation of
the pump.
•Once parts are dry they can be stored in a clean plastic
tub with a lid or in a clean plastic zipper bag.
Before Each Pumping Session
•Always wash and dry hands thoroughly with soap and
water before handling the Breastmilk Expression Set.
•Before assembling the Breastmilk Expression Set, be
sure that all of the parts are completely dry.
•Visually inspect the individual components for cracks,
chips, tears, discoloration or deterioration. These may
aect the functionality of the pump.
•Should you have any questions or concerns about
your parts please visit www.lansinoh.co.uk, call
+44(0)113205 4201 in the UK, or contact your
country distributor for guidance.
Cleaning After Each Pumping Session
•Disassemble the Breastmilk Expression Set, setting
aside tubing and connector.
•Rinse all parts with cold water immediately after use.
Place pump parts in a clean wash basin used only for
washing infant feeding equipment. Do not place pump
parts directly in the sink because germs in sinks or
drains could contaminate the pump.
•Hand wash all parts of the Breastmilk Expression Set
using warm soapy water. A teat brush may be used
to scrub the hard plastic pieces of the Breastmilk
Expression Set, but should not be used on the white
valve or diaphragm.
•Rinse parts with running clean, warm water, or by
submerging in fresh water in a separate basin that is
only used for cleaning infant feeding equipment.
•Place parts in a pot and cover with water making sure
there is room for all of the parts to float freely in the pot.
•Bring the water to a boil and allow to boil for 5 minutes.
•After boiling remove the parts from the pot with tongs
and place the pieces neatly on a clean paper towel or
in a clean drying rack and allow them to air dry.Do not
use a dish towel to rub or pat items dry because doing
so may transfer germs to the items.
•Allow the parts to dry completely before assembly and
use. Partially dried parts may aect the operation of
the pump.
•Once parts are dry they can be stored in a clean plastic
tub with a lid or in a clean plastic zipper bag.
•Clean your wash basin and bottle and/or teat brush
after each use.
•
The pump unit should be wiped down with a clean paper
towel or soft cloth after use. The pump unit should never be
put into water or other liquids for cleaning.
Parts can be cleaned in a steam or microwave steriliser.
Besure to follow the manufacturer’s instructions.
f
e
d
c
g
m
b
a
k
l
j
h
i