manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Larson Electronics
  6. •
  7. Cables And Connectors
  8. •
  9. Larson Electronics XLE-PA-N4X-1686-1PH-30A-600V-2P3W-P User manual

Larson Electronics XLE-PA-N4X-1686-1PH-30A-600V-2P3W-P User manual

XLE-PA-N4X-1686-1PH-30A-600V-2P3W-P
Larson Electronics, LLC Phone: (800) 369-6671 Fax: (903) 498-3364 www.larsonelectronics.com
1of 2
30A Industrial Metal Plug - 600V AC - 2P3W - Pin/Sleeve,
Style II Ground - N4X
Instruction Manual
WARNING:
READ CAREFULLY BEFORE OPERATING. RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE.
CRITICAL SAFETY INSTRUCTIONS:
Lasers can be hazardous and have unique safety considerations. Permanent eye injury and blindness is possible if lasers
are used incorrectly. Pay close attention to each safety REMARK and WARNING statement in the user manual. Read all
instructions carefully BEFORE operating this device.
Avoid direct eye contact with laser light. Never intentionally expose your eyes or others to direct laser light.
This laser product can potentially cause instant eye injury or blindness if laser light directly strikes the eyes.
It is illegal and dangerous to shine this laser into crowded areas, where the crowd or other personnel could get
direct laser beams or bright reflections into their eyes.
There are no user serviceable parts inside the unit. Do not open the housing or attempt any repairs yourself. In
the unlikely event your unit may require service, please contact the manufacturer.
NEMA 4X RATED LINE OF METALLIC PLUGS.
The XLE-PA-N4X-1686-1PH-30A-600V-2P3W-P is an industrial grade plug that carries a NEMA 4X rating are designed for heavy
duty industrial use. These devices supply power to both fixed and portable electrical equipment including pumps, generators,
welders, vacuums, blowers and similar apparatus. This pin/sleeve unit is rated at single-phase 600V AC/250V DC @ 50-400Hz
and 30 amps. The 2-pole, 3-wire plug is constructed of copper-free aluminum, brass, beryllium copper and 316 stainless steel with
a baked powder epoxy/polyester finish. This power accessory features style II grounding and a 0.55-1.20 grommet range.
Suitable for indoor or outdoor use. Applications include the wet, cold, hosedown, hazardous or corrosive areas in such industrial
applications as:
•Pulp & Paper Mills
•Electrical Power Plants
•Petrochemical Plants
•Wastewater Treatment
•Marine, Docks, Ports
•Construction Sites
•Breweries
•Refineries
•Chemical Plants
•Grain Facilities
•Textile Manufacturing
•Food Processing
Facilities
Plugs:
Octagonal style (patented) for a firm and sure grip when connecting or disconnecting is featured on both plug and cable connector
bodies. Insulators have high mechanical and dielectric strength and “Low Arc Tracking.” “Increased Safety” type box terminals with
gripper ribs securely clamp around conductors. Funneled conductor entry chambers lead all properly stripped conductors into
terminals simultaneously. NEMA 4X rating when inserted into a receptacle and locking ring is tightened. Includes suitability for
Type P marine cable.
Larson Electronics, LLC Phone: (800) 369-6671 Fax: (903) 498-3364 www.larsonelectronics.com 1of 2
THESE INSTRUCTIONS MAY NOT COVER ALL DETAILS OR VARIATIONS OF THIS PRODUCT FOR YOUR EQUIPMENT OR INSTALLATION REQUIREMENTS.
SHOULD FURTHER INFORMATION NOT COVERED BY THESE INSTRUCTIONS BE REQUIRED, PLEASE CONTACT LARSON ELECTRONICS BY EMAIL AT
SALES@LARSONELECTRONICS.COM OR BY PHONE AT 1-800-369-6671 FOR FURTHER ASSISTANCE.
PLEASE VISIT LARSONELECTRONICS.COM FOR WARRANTY AND RETURN INFORMATION.
XLE-PA-N4X-1686-1PH-30A-600V-2P3W-P
Details of Safety Time Delay Feature
The key slot provided in the receptacle engages the key of the plug permitting
entrance of the plug in the receptacle in only one position. See steps 1-4.
The contacts are enclosed in long accurate insulating cavities. It is in these cavities
that the arcs are extinguished. All contacts are made through round tellurium copper
tubing which is extra heavy to withstand arcing as required on the various ampere
ratings.
Plugs are equipped with an extra long grounding pole which establishes grounding
before the power contacts are engaged. These grounding poles are also the last to
break contact. This assures bonding of the portable device to the electrical conduit
system.
Plug then can be moved completely in
and be energized
Plug can move in only to the first step of
the keyway until...
...key is moved up
Align Keyway on plug with receptacle.
Receptacle Keyway
Key Plug
1
2
3
4

Other Larson Electronics Cables And Connectors manuals

Larson Electronics CGB-C1D1-MCHL Series User manual

Larson Electronics

Larson Electronics CGB-C1D1-MCHL Series User manual

Larson Electronics EPP-30A-2P3W-1FT-L6.30 User manual

Larson Electronics

Larson Electronics EPP-30A-2P3W-1FT-L6.30 User manual

Larson Electronics EPP-30A-2P3W-1FT-L1430 User manual

Larson Electronics

Larson Electronics EPP-30A-2P3W-1FT-L1430 User manual

Larson Electronics EPCO-20A Series Instruction Manual

Larson Electronics

Larson Electronics EPCO-20A Series Instruction Manual

Larson Electronics 10-50C User manual

Larson Electronics

Larson Electronics 10-50C User manual

Larson Electronics EXC-EYM-12C-1523 User manual

Larson Electronics

Larson Electronics EXC-EYM-12C-1523 User manual

Larson Electronics DCP-1205 User manual

Larson Electronics

Larson Electronics DCP-1205 User manual

Larson Electronics GAU-CR-30 User manual

Larson Electronics

Larson Electronics GAU-CR-30 User manual

Popular Cables And Connectors manuals by other brands

PowerBox Systems P2-SERVOBRIDGE instruction manual

PowerBox Systems

PowerBox Systems P2-SERVOBRIDGE instruction manual

Trolex TX3706 user manual

Trolex

Trolex TX3706 user manual

Burndy Continental Industries thermOweld BX-1 instructions

Burndy

Burndy Continental Industries thermOweld BX-1 instructions

Appsys ProAudio ADS-8 user manual

Appsys ProAudio

Appsys ProAudio ADS-8 user manual

Marechal Electric MELTRIC DXN Series operating instructions

Marechal Electric

Marechal Electric MELTRIC DXN Series operating instructions

DOCKTECK Type-C to DisplayPort Cable with HBR3 user manual

DOCKTECK

DOCKTECK Type-C to DisplayPort Cable with HBR3 user manual

MCM Custom Audio 50-15020 manual

MCM Custom Audio

MCM Custom Audio 50-15020 manual

IDEAL APP Power Drawer Assembly instructions

IDEAL

IDEAL APP Power Drawer Assembly instructions

cable matters Mini DisplayPort manual

cable matters

cable matters Mini DisplayPort manual

Regin E-Cable-RS232 manual

Regin

Regin E-Cable-RS232 manual

Harwin M80-940 Series Assembly instructions

Harwin

Harwin M80-940 Series Assembly instructions

Cadenceberge CAD-HV-HCA19 user manual

Cadenceberge

Cadenceberge CAD-HV-HCA19 user manual

Staubli MA273 Assembly instructions

Staubli

Staubli MA273 Assembly instructions

SY Electronics SY-HDBT-131EC SET user manual

SY Electronics

SY Electronics SY-HDBT-131EC SET user manual

Tlian T6 installation manual

Tlian

Tlian T6 installation manual

Blumfeldt Greenwire Select manual

Blumfeldt

Blumfeldt Greenwire Select manual

PRO SIGNAL PSG03640 user manual

PRO SIGNAL

PRO SIGNAL PSG03640 user manual

Tripp Lite P450-006 Specification sheet

Tripp Lite

Tripp Lite P450-006 Specification sheet

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.