4Copyright © 2016 LCJ CAPTEURS
1 GENERAL INFORMATION AND SAFETY GUIDELINE
1.1 GENERAL RECOMMENDATIONS
The LCJ Capteurs sensors are Ultrasonic wind
vanes/anemometers with accurate factory calibration.
Install the sensor in a location free from wind perturbation,
usually on the mast head.
Prepare the mast head for the mechanical installation.
Align the North mark of the bracket in order to have the
CV7 sensor heading to the bow.
The sensor’s fine alignment will be obtained with the
calibration functions of your instrumentation. Should it be
needed LCJ Capteurs can provide a’ software calibration
application upon request.
When necessary, install the interface junction boxes in a
protected and dry location.
Run the cable down to the display’s interface, avoiding
locations where other cables or equipment may produce
electromagnetic interferences (pilot’s ram, radio...) and cut
it to the right length. The cable’s length can be adjusted as
required providing junctions are made in the state of the
art.
Turn the power supply off before processing to any wiring
work. You can turn power on again only once all
installation and wiring is completed.
We recommend lightly tinning the wires before connecting
them to the screw terminals.
Use only genuine accessories supplied by LCJ Capteurs.
Do not attempt any modification to the unit.
Never paint any part of the unit or alter its surface in any
way.
Warranty is void in case of non-following the
instructions of use, repair or maintenance without
written authorisation.
1.2 MAINTENANCE AND REPAIR
The CV7 sensors do not require any maintenance. Check
the connections on a regular basis and make sure the
junction boxes are dry and protected.
If the Wind pages of your instruments do not display the
wind data correctly, refer to the manufacturer’s manual
and check the connections before asking for service to
your LCJ Capteurs dealer.
1.3 DISPOSAL
Equipments marked with the recycling symbol should be
processed via a recognized recycling agency. By
agreement, they may be returned to the manufacturer. Do
not mix electronic disposal with domestic or industrial
refuse.
1.4 USE OF THIS MANUAL
This manual serves as a guideline for the safe and
effective installation, operation and maintenance of the
Ultrasonic Wind Sensors of the CV7 range from LCJ
Capteurs. It is recommended to follow carefully the
instructions contained herein.
Keep this manual in a safe place!
1.5 VALIDITY OF THIS MANUAL
All of the specifications, provisions and instructions
contained in this manual apply solely to the following
products:
CV7 standard Ultrasonic Wind Sensor
CV7 Ultrasonic Wind Sensor / Vertical
CV7-C CV7 high speed Ultrasonic Wind Sensor/
CV7SF CV7 / Wireless Ultrasonic Wind Sensor /
CV7SF USB CV7 / Wireless Ultrasonic Wind Sensor /
CV7 to NMEA2000 interface (inc. baro.)
Canbus-RM CanBus interface for rotating mast
Interface for Raymarine ST
Junction box with baro sensor
Junction box with USB connector
Support
Bracket for installation on a vertical
surface
1’’standard adapter ( VHF or GPS type)
1.6 LIMITED WARRANTY
The LCJ Capteurs are guaranteed against manufacturing
defects for a period of two years from the date of
purchase. It is limited to the repair and/or replacement of
the product. It does not cover installation costs and
shipping costs of faulty units. A proof of purchase may be
asked when filling the warranty request which must be
received by writing. Once the warranty request is accepted
by LCJ Capteurs, the unit must be sent to LCJ Capteurs’
address in France. LCJ Capteurs guarantees that each of
their ultrasonic wind sensors are tested and calibrated
before despatch. Operations not in compliance with the
instructions described in the present manual may result to
damage the unit or alter its performances. In such cases,
the warranty is void.
1.7 RESPONSABILITY
LCJ Capteurs do not accept responsibility for:
•Consequential damage to the use of a CV7 sensor
•Possible errors in the manuals and their results