LCJ CAPTEURS CV7 User manual

Copyright © 2016 LCJ CAPTEURS CV7 manual 2016 / English 1
USERS MANUAL
CV7
CV7 Standard
CV7-V
CV7-C
CV7SF
LCJ CAPTEURS
29 Allée des Cinq Continents
ZA le Chêne Ferré
44120 VERTOU – France
Tél : 33(0)2 40 05 08 55
Email : info@lcjcapteurs.com
www.lcjcapteurs.com
SIRET : 42493307500022 / RCS Nantes
VAT : FR17424933075
EN 55022 EN55024

2Copyright © 2016 LCJ CAPTEURS
CONTENT:
1GENERAL INFORMATION AND SAFETY GUIDELINE ................................................................................................. 4
1.1 GENERAL RECOMMENDATIONS....................................................................................................................4
1.2 MAINTENANCE AND REPAIR .......................................................................................................................... 4
1.3 DISPOSAL .........................................................................................................................................................4
1.4 USE OF THIS MANUAL.....................................................................................................................................4
1.5 VALIDITY OF THIS MANUAL ............................................................................................................................4
1.6 LIMITED WARRANTY........................................................................................................................................4
1.7 RESPONSABILITY ............................................................................................................................................4
2INSTALLATION OF A CV7 WIND SENSOR................................................................................................................... 5
2.1 TYPICAL INSTALLATION OVERVIEW.............................................................................................................. 5
2.2 SENSOR ALIGNEMENT....................................................................................................................................5
2.3 CONNECTIONS.................................................................................................................................................5
3CV7 Standard.................................................................................................................................................................. 6
3.1 CONTENT OF DELIVERY ................................................................................................................................. 6
3.2 SENSOR ALIGNEMENT....................................................................................................................................6
3.3 DIMENSIONS.....................................................................................................................................................6
4CV7-V............................................................................................................................................................................... 7
4.1 CONTENT OF DELIVERY ................................................................................................................................. 7
4.2 SENSOR ALIGNEMENT....................................................................................................................................7
4.3 DIMENSIONS.....................................................................................................................................................7
5CV7-C............................................................................................................................................................................... 8
5.1 CONTENT OF DELIVERY ................................................................................................................................. 8
5.2 SENSOR ALIGNEMENT....................................................................................................................................8
5.3 DIMENSIONS.....................................................................................................................................................8
6WindyPlug: connecting a CV7 to a NMEA2000 network............................................................................................. 9
6.1 TYPICAL INSTALLATION OVERVIEW.............................................................................................................. 9
6.2 RECOMMENDATIONS......................................................................................................................................9
6.3 INSTALLATION.................................................................................................................................................. 9
6.4 CONNECTIONS.................................................................................................................................................9
6.5 DATA SOURCES...............................................................................................................................................9
6.6 TECHNICAL SPECIFICATIONS........................................................................................................................9
7OPTION CANBUS-RM................................................................................................................................................... 10
7.1 TYPICAL INSTALLATION OVERVIEW............................................................................................................ 10
7.2 CONNECTIONS............................................................................................................................................... 10
7.3 INTERFACE..................................................................................................................................................... 10
7.4 COMMISSIONING ........................................................................................................................................... 10
7.5 CALIBRATING THE MAST ANGLE SENSOR: MID-SHIP AND MAST ANGLE ENDS.................................... 10
7.6 WIND SENSOR ALIGNEMENT ....................................................................................................................... 10
7.7 CALIBRATION OF THE BAROMETER............................................................................................................ 10
7.8 DIMENSIONS OF THE CANBUS JUNCTION BOX......................................................................................... 10
8ST OPTION (V3) ............................................................................................................................................................ 11
8.1 TYPICAL INSTALLATION OVERVIEW............................................................................................................ 11
8.2 CONNECTIONS............................................................................................................................................... 11
8.3 COMMISSIONING ........................................................................................................................................... 11
8.4 DIMENSIONS................................................................................................................................................... 11
9BG OPTION (V2)............................................................................................................................................................ 11
9.1 TYPICAL INSTALLATION OVERVIEW............................................................................................................ 11
9.2 CONNECTIONS............................................................................................................................................... 11
9.3 COMMISSIONING ........................................................................................................................................... 11
9.4 DIMENSIONS................................................................................................................................................... 11

Copyright © 2016 LCJ CAPTEURS 3
10 SIL OPTION (NEXUS NX2, SILVA and FI30) ............................................................................................................... 12
10.1 DIMENSIONS................................................................................................................................................... 12
11 BARO OPTION.............................................................................................................................................................. 12
11.1 DIMENSIONS................................................................................................................................................... 12
12 USB OPTION................................................................................................................................................................. 13
12.1 CONNECTIONS............................................................................................................................................... 13
12.2 SPECIFICATIONS ........................................................................................................................................... 13
13 MOUNT ADAPTERS...................................................................................................................................................... 13
13.1 1”ADAPTOR..................................................................................................................................................... 13
13.2 MOUNT ON VERTICAL SURFACE ................................................................................................................. 13
14 SPECIFICATIONS ......................................................................................................................................................... 14
15.2 NMEA2000 INTERFACES ............................................................................................................................... 15
15 ADDENDUM .................................................................................................................................................................. 15
15.1 NMEA0183 INTERFACES ............................................................................................................................... 15
15.2 NMEA2000 INTERFACES ............................................................................................................................... 15
15.3 MOUNTING TEMPLATE.................................................................................................................................. 16
16 CV7SF............................................................................................................................................................................ 18
16.1 CONTENT OF DELIVERY ............................................................................................................................... 18
16.2 INSTALLATION................................................................................................................................................ 18
16.3 SENSOR ALIGNEMENT.................................................................................................................................. 18
16.4 CONNECTIONS............................................................................................................................................... 18
16.5 DIMENSIONS................................................................................................................................................... 18
17 CV7SF-USB................................................................................................................................................................... 19
17.1 CONTENT OF DELIVERY ............................................................................................................................... 19
17.2 INSTALLATION................................................................................................................................................ 19
17.3 SENSOR ALIGNEMENT.................................................................................................................................. 19
17.4 USB CONNECTION......................................................................................................................................... 19
17.5 DIMENSIONS................................................................................................................................................... 19

4Copyright © 2016 LCJ CAPTEURS
1 GENERAL INFORMATION AND SAFETY GUIDELINE
1.1 GENERAL RECOMMENDATIONS
The LCJ Capteurs sensors are Ultrasonic wind
vanes/anemometers with accurate factory calibration.
Install the sensor in a location free from wind perturbation,
usually on the mast head.
Prepare the mast head for the mechanical installation.
Align the North mark of the bracket in order to have the
CV7 sensor heading to the bow.
The sensor’s fine alignment will be obtained with the
calibration functions of your instrumentation. Should it be
needed LCJ Capteurs can provide a’ software calibration
application upon request.
When necessary, install the interface junction boxes in a
protected and dry location.
Run the cable down to the display’s interface, avoiding
locations where other cables or equipment may produce
electromagnetic interferences (pilot’s ram, radio...) and cut
it to the right length. The cable’s length can be adjusted as
required providing junctions are made in the state of the
art.
Turn the power supply off before processing to any wiring
work. You can turn power on again only once all
installation and wiring is completed.
We recommend lightly tinning the wires before connecting
them to the screw terminals.
Use only genuine accessories supplied by LCJ Capteurs.
Do not attempt any modification to the unit.
Never paint any part of the unit or alter its surface in any
way.
Warranty is void in case of non-following the
instructions of use, repair or maintenance without
written authorisation.
1.2 MAINTENANCE AND REPAIR
The CV7 sensors do not require any maintenance. Check
the connections on a regular basis and make sure the
junction boxes are dry and protected.
If the Wind pages of your instruments do not display the
wind data correctly, refer to the manufacturer’s manual
and check the connections before asking for service to
your LCJ Capteurs dealer.
1.3 DISPOSAL
Equipments marked with the recycling symbol should be
processed via a recognized recycling agency. By
agreement, they may be returned to the manufacturer. Do
not mix electronic disposal with domestic or industrial
refuse.
1.4 USE OF THIS MANUAL
This manual serves as a guideline for the safe and
effective installation, operation and maintenance of the
Ultrasonic Wind Sensors of the CV7 range from LCJ
Capteurs. It is recommended to follow carefully the
instructions contained herein.
Keep this manual in a safe place!
1.5 VALIDITY OF THIS MANUAL
All of the specifications, provisions and instructions
contained in this manual apply solely to the following
products:
Part
Description
CV7
CV7 standard Ultrasonic Wind Sensor
CV7-V
CV7 Ultrasonic Wind Sensor / Vertical
CV7-C CV7 high speed Ultrasonic Wind Sensor/
long carbon vertical arm
CV7SF CV7 / Wireless Ultrasonic Wind Sensor /
NMEA0183 receiver
CV7SF USB CV7 / Wireless Ultrasonic Wind Sensor /
receiver for USB
WindyPlug
CV7 to NMEA2000 interface (inc. baro.)
Canbus-RM CanBus interface for rotating mast
(NMEA2000)
Option ST
Interface for Raymarine ST
Option BG
Interface for B&G
Option baro
Junction box with baro sensor
Option USB
Junction box with USB connector
Support
Vertical
Bracket for installation on a vertical
surface
Adapt 1’’
1’’standard adapter ( VHF or GPS type)
1.6 LIMITED WARRANTY
The LCJ Capteurs are guaranteed against manufacturing
defects for a period of two years from the date of
purchase. It is limited to the repair and/or replacement of
the product. It does not cover installation costs and
shipping costs of faulty units. A proof of purchase may be
asked when filling the warranty request which must be
received by writing. Once the warranty request is accepted
by LCJ Capteurs, the unit must be sent to LCJ Capteurs’
address in France. LCJ Capteurs guarantees that each of
their ultrasonic wind sensors are tested and calibrated
before despatch. Operations not in compliance with the
instructions described in the present manual may result to
damage the unit or alter its performances. In such cases,
the warranty is void.
1.7 RESPONSABILITY
LCJ Capteurs do not accept responsibility for:
•Consequential damage to the use of a CV7 sensor
•Possible errors in the manuals and their results

Copyright © 2016 LCJ CAPTEURS 5
2 INSTALLATION OF A CV7 WIND SENSOR
2.1 TYPICAL INSTALLATION OVERVIEW
This diagram features a CV7 Standard. The typical
installation is the same for CV7-V and CV7-C
2.2 SENSOR ALIGNEMENT
The CV7 sensor must be installed with the “Nord” mark on
the bracket aligned to the geographical North for a fix
installation on shore and to the bow on a vessel.
Fine alignment can be performed with the application
“configuration CV7” available upon request.
2.3 CONNECTIONS
Red wire + Power
Blue wire - Power
Yellow wire NMEA TX +
Green wire NMEA RX -
Connect to 12 V power supply (8 - 33 VDC).
Connect the yellow and green wires to the NMEA input of
the instrument.

6Copyright © 2016 LCJ CAPTEURS
.
3 CV7 Standard
3.1 CONTENT OF DELIVERY
3.2 SENSOR ALIGNEMENT
CV7 sensor view from below
3.3 DIMENSIONS
The oblique bracket is meant to be mounted on a
horizontal surface. It is usually fixed on the mast head of a
sailing boat. The arm points to the bow.
CV7 with oblique arm
25 m cable
User manual
Oblique bracket

Copyright © 2016 LCJ CAPTEURS 7
4 CV7-V
4.1 CONTENT OF DELIVERY
4.2 SENSOR ALIGNEMENT
A mark below the sensor indicates the alignment. The
vertical bracket is designed for mounting on a horizontal
surface, usually the mast head on a sailing boat. For
mounting on the side of the mast, an additional bracket is
available separately (see section 13.2).
The CV7-V sensor must be installed with the “Nord” mark
on the bracket aligned to the geographical North for a fix
installation on shore.
4.3 DIMENSIONS
CV7 sensor
With vertical arm
25 m cable
User manual
Bracket

8Copyright © 2016 LCJ CAPTEURS
5 CV7-C
5.1 CONTENT OF DELIVERY
5.2 SENSOR ALIGNEMENT
A mark below the sensor indicates the alignment. The
vertical bracket is designed for mounting on a horizontal
surface, usually the mast head on a sailing boat. For
mounting on the side of the mast, an additional bracket is
available separately (see section 13.2).
The CV7-C sensor must be installed with the “Nord” mark
on the bracket aligned to the geographical North for a fix
installation on shore.
5.3 DIMENSIONS
Weight: 200 gr (sensor + arm + bracket)
CV7 sensor
With vertical
carbon arm
25 m cable
User manual
Bracket
760 mm

Copyright © 2016 LCJ CAPTEURS 9
6 WindyPlug: connecting a CV7
to a NMEA2000 network
6.1 TYPICAL INSTALLATION OVERVIEW
The WindyPlug option is compatible with all CV7 sensors.
6.2 RECOMMENDATIONS
The WindyPlug must be located in a protected area and
subject to atmospheric pressure.
Do not attempt any modification to the unit.
Never paint any part of the unit or alter its surface in any
way.
Warranty is void in case of non-following the instructions of
use, repair or maintenance without written authorisation.
6.3 INSTALLATION
WindyPlug allows connecting a CV7 to NMEA2000
system. It features also an atmospheric pressure and
ambient temperature sensor.
Its MICRO C male plug connects directly to the NMEA
2000 backbone.
You may need to add a T connector (not supplied).
6.4 CONNECTIONS
The CV7 comes with a 25 metres cable featuring crimp
terminals. If the cable is cut to shorten the length, it is
strongly recommended to use new terminals for a proper
connection. The CV7 must be connected to the WindyPlug
prior to plugging the device to the NMEA2000 backbone.
Open the protective cap and slide the 4 wires through it
one after another, and then, the cable’s cover.
Insert the wires terminals in the connectors, colour for
colour. Just push them, they will be trapped in place.
Blue
0V - power supply
Red
12V + power supply
Green
NMEA -
Yellow
NMEA +
Push the protective cap back in place. The hole in the cap
must be aligned to the Led indicator.
Once the CV7 connection is completed you can plug the
WindyPlug to the NMEA2000 backbone.
6.5 DATA SOURCES
Select the data sources on a multifunction display of your
NMEA2000 system. You will be given the choice between
V2 and V3 depending of your NMEA2000 system’s
version.
6.6 TECHNICAL SPECIFICATIONS
L 81 mm X Ø 17.5 mm
Weight: 35 g
Connector: MICRO C male NMEA2000
Protection: IP66 (WindyPlug connected)
Power supply: via NMEA2000 network. 8V / 28VDC
Consumption: 1 LEN / < 40mA with sensor.
Operation indicator: 1 flashing LED
Pressure sensor: Hydrophobic membrane
Pressure’s measure range: 850 hPa / 1150 hPa
Resolution*: 1 hPa with NMEA2000 Version 2 systems
0.1 hPa with NMEA2000 Version 3 systems
Relative accuracy*: +/- 0.5 hPa @ 20°C
Absolute accuracy*: +/- 1.5 hPa @ 20°C
If it happens that you need to
disconnect the CV7 wires, simply
press on the push-
button for
easy release.
*1 hPa = 1 mBar = 0.003 inHg / 0 °C = 32 °F

10 Copyright © 2016 LCJ CAPTEURS
7 OPTION CANBUS-RM
7.1 TYPICAL INSTALLATION OVERVIEW
The CanBus-RM option is compatible with all CV7 sensors.
Connectors and mast angle sensor are not supplied.
7.2 CONNECTIONS
Open the junction box to access the connectors
The CanBus-RM junction box features connection
terminals for the mast angle sensor (potentiometer), the
CV7 and the NMEA2000 network.
7.3 INTERFACE
TX PGNs: 59392, 60928, 126464, 126996, 130306,
130311, 130314
RX PGNs: 59392, 59904; 60928
Consumption: 2 LEN
7.4 COMMISSIONING
Refer to the connected instruments’ manual for pages
setup and all functions related to wind and atmospheric
pressure functions. Once all wiring and connections are
completed, turn the power on and check the alignment. It
may be adjusted from your instrument’s setup menu.
Alternatively, this can be done directly from the CanBus.
7.5 CALIBRATING THE MAST ANGLE SENSOR:
MID-SHIP AND MAST ANGLE ENDS
Use the «- » and « +» keys to change a value that is
previously selected with the switch button “S1”.
In positions 3 to 6, the values read on the wind displays
are the mast angles measures, used for calibration of the
mast angle sensor.
The calibration process is done in the following order:
Position 7: + “S1”, reset to factory settings
Position 6: identification of the potentiometer’s polarity
(port-starboard values)
Position 5: mid-ship. Place mast in mid-ship position and
set the angle to 0°
Position 4: port-end. Place the mast in port-end position
and set the angle to the relevant value (theoretical or
measured)
Position 3: starboard-end. Place the mast in starboard-
end position and set the angle to the relevant value
(theoretical or measured)
7.6 WIND SENSOR ALIGNEMENT
Fine alignment of the mast sensor can be achieved at sea.
Sail on starboard and port to note the correction that
needs to be applied from a tack to another.
Place the rotary button (S1) in position 1 and use the “+”
and “-“ keys to change the value read on the display.
Adjust the value accordingly to the difference measured
from a tack to another during sea trials.
The wind angle will correctly read on the display.
7.7 CALIBRATION OF THE BAROMETER
The atmospheric pressure sensor is calibrated against the
nearest reference located on the shore level, such as a
weather station.
The rotary button (S1) placed on position 2 allows
calibrating the atmospheric pressure. Once the button is in
position 2, the value on the display can be adjusted using
the “+” and “-“ keys to match the reference. Make sure
your display is set to “mb” unit.
These values are automatically stored in the device’s
memory. They can be fine adjusted after sea trials.
7.8 DIMENSIONS OF THE CANBUS JUNCTION BOX
130x80x30 mm / 150gr

Copyright © 2016 LCJ CAPTEURS 11
8 ST OPTION (V3)
8.1 TYPICAL INSTALLATION OVERVIEW
8.2 CONNECTIONS
This option allows the connection of a CV7 directly to the
ROTAVECTA© input on your Raymarine instrument (ST40
Wind or ST60 Wind).
Power the junction box and the CV7 sensor as indicated
below.
Connect the data wires (yellow and green) colour for
colour. The power supply is connected to Red for + 12V
and Blue for – 0V.
Open the box to access the terminals:
8.3 COMMISSIONING
Once all connections are completed, refer to the
Raymarine manual for the sensor’s alignment.
8.4 DIMENSIONS
Dimensions : 131 x 58 x 37 mm
9 BG OPTION (V2)
9.1 TYPICAL INSTALLATION OVERVIEW
9.2 CONNECTIONS
This option allows the connection of a CV7 directly to the
MHU input on your B&G.
Power the junction box and the CV7 sensor as indicated
below.
Connect the data wires (yellow and green) colour for
colour. The power supply is connected to Red for + 12V
and Blue for – 0V.
Open the box to access the terminals:
9.3 COMMISSIONING
Once all connections are completed, refer to the B&G
manual for the sensor’s alignment.
9.4 DIMENSIONS
Dimensions : 131 x 58 x 37 mm

12 Copyright © 2016 LCJ CAPTEURS
10 SIL OPTION
(NEXUS NX2, SILVA and FI30)
CV7-Sil is a standard CV7 with a specific configuration
Simply connect your CV7 to the serial port of a PC and
use our configuration software.
.
10.1 DIMENSIONS
Dimensions : 131 x 58 x 37 mm
11 BARO OPTION
The BARO OPTION is a junction box that adds the
atmospheric pressure to the NMEA0183 CV7 data.
Connect as follow:
11.1 DIMENSIONS
Dimensions : 68 x 58 x 22 mm
+ NMEA OUT
- NMEA OUT
0V NMEA
CV7- Green
CV7- Yellow
CV7- Blue
CV7- Red
0V
+ 12 VDC

Copyright © 2016 LCJ CAPTEURS 13
12 USB OPTION
12.1 CONNECTIONS
The junction box features a screw terminal and a standard
USB cable. Open the box to complete the connections.
The USB junction box is powered by the USB connection
to the PC.
Connect the wire coming from the CV7 as indicated on the
diagram above.
Plug the USB cable to the PC. The driver will automatically
be installed by the Windows®system (Windows 7®and
above). Alternatively, the latest version of the driver can be
downloaded from the technical support section of the
website (www.lcjcapteurs.com). It is an executable file.
Double-click on the file to launch the installation.
Once the CV7 is connected to the USB port, your relevant
software will immediately identify the
NMEA0183®sentences via an emulated COM port.
12.2 SPECIFICATIONS
Dimensions: 57 x 43 x 24 mm
Weight: 20 g (without cable and connector)
Cable length: 1.50 m
Standard USB type A connector
Screw terminal
13 MOUNT ADAPTERS
13.1 1”ADAPTOR
This optional accessory allows mounting a CV7 sensor on
any standard antenna mounting bracket.
External diameter: 40 mm
Height: 50 mm
13.2 MOUNT ON VERTICAL SURFACE
CV7-V base is compatible with standard brackets available
on the market, such as the GLOMEX featured on the
picture below.
.

14 Copyright © 2016 LCJ CAPTEURS
14 SPECIFICATIONS
CV7 CV7-V CV7-C CV7SF
Output data signal
NMEA
©
or NEXUS
©
NMEA
©
or NEXUS
©
NMEA
©
or NEXUS
©
NMEA
©
Output update
2 per second
2 per second
4 per second
1 per sec. In day-
light1 every 3
seconds at sunrise
and sunset,
Wind module sensitivity
0.25 Kt
0.25 Kt
0.25 Kt
0.25 Kt
Wind module resolution
0.1 Kt
0.1 Kt
0.1 Kt
0.1 Kt
Wind module dynamic
0.25 to 80 Kts
0.25 to 80 Kts
0.25 to 80 Kts
0.25 to 80 Kts
Direction sensitivity
+
/- 1°
+
/- 1°
+
/- 1°
+
/- 1°
Direction resolution
1°
1°
1°
1°
Power supply
8 to 33 VDC
8 to 33 VDC
8 to 33 VDC
photovoltaic cells
for transmitter 6.5 to
27 VDC for receiver
Electrical consumption
9.5 mA
9.5 mA
9.5 mA
autonomous for
transmitter
5.8 mA for receiver
Operating temperature range
without iceing
-15°C/55°C
-15°C/55°C
-15°C/55°C
-10°C/55°C
Connection line
25 m of cable
4 x 0,22 mm
2
25 m of cable
4 x 0,22 mm
2
25 m of cable
4 x 0,22 mm
2
Radio transmitter
433 mHz
Tx power : 10 dbm
Message time :
25 ms
Interconnection
Direct +12 V
0 V
NMEA
©
+
NMEA
©
-
Direct +12 V 0 V
NMEA
©
+
NMEA
©
-
Direct +12 V 0 V
NMEA
©
+
NMEA
©
-
Receiver
Superheterodyne
ASK 433 MHz
Sensitivity: -110
dbm
Outputs via screw
terminal
Weight of the head
100 g
100 g
100 g
100 g
Arm
Oblique 30 cm arm
Alu Ø 12 mm
Vertical 30 cm
arm
Alu Ø 16 mm
Vertical 75 cm
carbon arm Ø 16
mm
Vertical 30 cm arm
Alu Ø 16 mm
Mounting base
Bracket
Bracket
Bracket
Bracket
Total weight including arm and
bracket
200 g
200 g
200 g
200 g

Copyright © 2016 LCJ CAPTEURS 15
15 ADDENDUM
15.1 NMEA0183 INTERFACES
NMEA0183 :
Output on a 4mA current loop.
4800 Bauds, no parity, 1 stop Bit
Constant flow at 500 milliseconds
(except CV7-C, at 266 milliseconds)
Variable fields lengths, comma separator.
Sentence prefix:$
End of sentence: CR,LF
Typical sentences output by CV7, CV7-V, CV7-C :
$IIMWV,225.0,R,000.0,N,A*38
$WIXDR,C,022.0,C,,*52
$PLCJ,5801,5F01,AA,4253,3341
$PLCJEA870,6D98,C500,0056,AC,
« Wind » sentence:
$IIMWV,226.0,R,000.0,N,A *0B CheckSum
CV7 status.A :
correct measure
V : incorrect measure
Wind speed unit. N = knots
Wind speed
Reference
Wind direction in degrees
« Wind temperature » sentence:
$WIXDR,C,022.0,C,,*52 CheckSum
Unit°C
Value with one decimal
Sentences added by the Baro3 option:
$IIVWR,014.0,R,02.40,N,01.23,M,004.44,K*7E
$WIMDA,,I,1.0200,B,021.5,C
Sentences for LCJ CAPTEURS technical use only:
$PLCJ,AAAA,BBBB,CC,,,,DDDD,EEEE
$PLCJEFFFF,GGGG,HHHH,IIII,JJ
15.2 NMEA2000 INTERFACES
15.2 NMEA2000 INTERFACES
NMEA 2000 manufacturer ID: 499
WindyPlug:
NMEA2000 V2 PGNs:
- TX: 59392; 60928; 126464; 126996; 130306; 130311
- RX: 59392, 59904; 60928; 130315
Product ID:
- LCJ Capteurs CV7_Ultrasonic_Wind_SensorV2
NMEA2000 V3 PGNs:
- TX: 59904; 60928; 126464; 126996; 130306; 130312; 130314
- RX: 59392; 59904; 60928; 130315
Product ID:
- LCJ Capteurs CV7_Ultrasonic_Wind_SensorV3
Logging two minutes of NMEA sentences flow allows making a proper diagnostic.

16 Copyright © 2016 LCJ CAPTEURS
15.3 MOUNTING TEMPLATE
WARNING! Check the scale when printing this document. Measure indications are in millimetres.
Vertical bracket:

Copyright © 2016 LCJ CAPTEURS 17
Oblique bracket:

18 Copyright © 2016 LCJ CAPTEURS
16 CV7SF
16.1 CONTENT OF DELIVERY
16.2 INSTALLATION
The CV7SF wind sensor is designed for operation outdoor,
exposed to natural light. It must be installed in an area free
from any air flow perturbation. Choose a location free from
any obstacle and situated at least 150 cm from the ground.
The radio signal maximum range is 200 meters. Best
results are obtained in a 50 meters distance between the
sensor and its receiver. The signal can be perturbated by
materials such as carbon, aluminium, steel...
A minimum distance of 10 meters between the arm and
any conductive material is recommended. Specific
environments may cause bad reception. Please contact
our technical support in that case.
16.3 SENSOR ALIGNEMENT
A mark below the sensor indicates the alignment. The
vertical bracket is designed for mounting on a horizontal
surface, usually the mast head on a sailing boat. For
mounting on the side of the mast, an additional bracket is
available separately (see section 13.2). The CV7 sensor
must be installed with the “Nord” mark on the bracket
aligned to the geographical North for a fix installation on
shore. Use a compass, taking the deviation in account.
16.4 CONNECTIONS
Open the receiver to access the connection terminal. The
NMEA0183 data output is connected as shown below:
16.5 DIMENSIONS
CV7SF sensor
With vertical arm
User manual
Receiver
The CV7SF is compatible with the Directive 1999/5/CE "R&TTE"

Copyright © 2016 LCJ CAPTEURS 19
17 CV7SF-USB
17.1 CONTENT OF DELIVERY
17.2 INSTALLATION
The CV7SF wind sensor is designed for operation outdoor,
exposed to natural light. It must be installed in an area free
from any air flow perturbation. Choose a location free from
any obstacle and situated at least 150 cm from the ground.
The radio signal maximum range is 200 meters. Best
results are obtained in a 50 meters distance between the
sensor and its receiver. The signal can be perturbated by
materials such as carbon, aluminium, steel...
A minimum distance of 10 meters between the arm and
any conductive material is recommended. Specific
environments may cause bad reception. Please contact
our technical support in that case.
17.3 SENSOR ALIGNEMENT
A mark below the sensor indicates the alignment. The
vertical bracket is designed for mounting on a horizontal
surface, usually the mast head on a sailing boat. For
mounting on the side of the mast, an additional bracket is
available separately (see section 13.2). The CV7 sensor
must be installed with the “Nord” mark on the bracket
aligned to the geographical North for a fix installation on
shore. Use a compass, taking the deviation in account.
17.4 USB CONNECTION
Plug the USB cable to the PC. The driver will automatically
be installed by the Windows®system (Windows 7®and
above). Alternatively, the latest version of the driver can be
downloaded from the technical support section of the
website (www.lcjcapteurs.com). It is an executable file.
Double-click on the file to launch the installation.
Once the CV7 is connected to the USB port, your relevant
software will immediately identify the
NMEA0183®sentences via an emulated COM port.
17.5 DIMENSIONS
CV7SF sensor
With vertical arm
User manual
Receiver with cable and
USB connector
The CV7SF is compatible with the Directive 1999/5/CE "R&TTE"
Other manuals for CV7
2
This manual suits for next models
4
Table of contents
Other LCJ CAPTEURS Accessories manuals