Leader Evaporator PATRIOT MAX User manual

Leader Evaporator Co., Inc.
49 Jonergin Drive
Swanton, VT 05488
Tel: 802-868-5444
www.leaderevaporator.com
PATRIOT MAX AND STANDARD PAN SETS

PATRIOT MAX & STANDARD EVAPORATOR PAN SET 2019 Page:
2
CONTENTS
Contents.............................................................................................................................................................. 2
INTRODUCTION: THEORY OF OPERATION ............................................................................................................. 3
FORMING THE GRADIENT ................................................................................................................................... 3
Firing (if using a wood fired arch) ................................................................................................................... 3
Defoamer ........................................................................................................................................................ 4
Minimize Reversal Effects............................................................................................................................... 4
EQUIPMENT DESCRIPTION...................................................................................................................................... 5
INCLUDED PARTS: ............................................................................................................................................... 5
OPTIONAL SETUP ITEMS AND REPLACEMENT PARTS......................................................................................... 7
DIAGRAM OF THE PATRIOT EVAPORATOR PAN SET............................................................................................... 8
SETUP OF THE PATRIOT EVAPORATOR PAN SET..................................................................................................... 8
RECEIVING YOUR EVAPORATOR: ........................................................................................................................ 8
SUGAR HOUSE SETUP: ........................................................................................................................................ 8
SETTING UP THE PANS: ....................................................................................................................................... 9
OPERATING THE EVAPORATOR............................................................................................................................. 18
SYRUP PAN REVERSAL....................................................................................................................................... 18
MAKING SYRUP ................................................................................................................................................. 20
DAILY SHUTDOWN ............................................................................................................................................ 21
MAINTENANCE...................................................................................................................................................... 22
Daily .................................................................................................................................................................. 22
Periodic ............................................................................................................................................................. 22
End Of Season ................................................................................................................................................... 22
Beginning Of Season Startup ............................................................................................................................ 23
FEEDBACK.............................................................................................................................................................. 23
NOTES.................................................................................................................................................................... 23
ATTACHMENT #1: HYDROMETERS....................................................................................................................... 24
HYDROMETER FUNCTION ..................................................................................................................................... 24
USE OF A HYDROMETER ....................................................................................................................................... 24
Preparing A New Hydrometer For Use ............................................................................................................. 24
Using The Hydrometer...................................................................................................................................... 24

PATRIOT MAX & STANDARD EVAPORATOR PAN SET 2019 Page:
3
INTRODUCTION: THEORY OF OPERATION
A maple syrup evaporator works under the principal of a gradient. As the sap boils, it concentrates. As it concentrates,
the volume is reduced and the solids (sugar concentration) increase. As the volume is reduced the liquid works to
maintain the levels across the evaporator so less concentrated sap flows into areas where there is more concentrated
sap. During the evaporation process the percent of sugar will change from the incoming (approximately 2%) to the draw
off (approximately 66%).
FORMING THE GRADIENT
When the evaporator is first filled, the concentration of the sap is the same throughout. The gradient is formed as the
water is evaporated from the sap in the syrup pan and the flue pan, and as the new sap enters the flue pan.
As the sap boils it loses moisture and becomes denser / more concentrated. As it is becoming concentrated it loses
volume. As it loses volume additional sap will try to keep the levels constant and at the same concentration. This is
occurring in both the flue pan and the syrup pan.
In the flue pan less concentrated sap enters through the float box into the first flue pan compartment and begins to
concentrate. As it concentrates it moves toward the second compartment of the flue pan. Early in the boil the second
compartment will become denser as the “fresh” sap entering the first compartment from the float box keeps pushing
the denser sap around.
As the syrup pan boils, the sap continues to become denser. The flue pan sap is pushed into the syrup pan making sap in
the first syrup pan compartment less dense. The sap from the first syrup pan compartment is pushed to the next
compartment where the sap is denser and then to the densest compartment, the “syrup” compartment. The syrup is
drawn off the evaporator from this compartment and more sap flows across all the compartments of the evaporator to
replace the volume of syrup drawn off.
With a good gradient in place there will be a measureable difference in the liquid levels between one side of the syrup
pan and the other. You may note a difference of ½”.
PROPER OPERATIONS TO MAINTAIN GRADIENT:
Firing
Defoamer
Minimize Reversal Effects
During operations you will be working to maintain a consistent gradient. This is done through firing level, control of
foaming, and minimizing the effects of reversal.
Firing (if using a wood fired arch)
During firing you are seeking to maintain the same boil all the time. By doing so, the liquid “push” in the pans will
remain consistent. If the boil reduces, liquid depths in both pans will start to equalize, losing the gradient. In order to
maintain the boil the following should be of concern:
1. Wood to use
a. Mix of hardwood (longer lasting, more BTUs) and softwood (quicker, intense heat).
b. Avoid slabs as they do not allow heat to evenly reach the pan
c. Split wood to the diameter and sized in length to match the length of the grates in use
Width of Evaporator
Diameter to Split Wood
24”
2” to 3”
30” and 36”
2” to 4”
40”and 48”
2” to 5”
60”and 72”
3” to 6”
2. Loading wood into the arch

PATRIOT MAX & STANDARD EVAPORATOR PAN SET 2019 Page:
4
a. Wood should stay on the grates and a minimum of 2” to 5” inside from the door so wood fire does not
heat the arch face
b. Criss-cross the wood as best possible so oxygen can reach all wood efficiently
c. Do not hit the flues when loading wood
3. When to fire
a. Keep a consistent stack temperature with less than 150°F range
b. Maintain the arch ½ to ⅔full
c. Fire consistently with small amounts of wood to maintain level of heat
d. Use timer to stay on schedule with firings
e. Adjust firing intervals as needed to maintain an even boil
Defoamer
The purpose of defoamer is to prevent foam build up in the pans. Foam build up will prevent proper evaporation of the
water from the sap. It will give a false liquid level to the float not allowing the incoming sap to flow in a consistent
manner. Inconsistent defoamer usage will create large volume adds of sap into the pans as the foam is reduced (when
you do add defoamer) and the float seeks to replace the level with incoming sap. The following items should be of
concern in the use of defoamer:
1. Use defoamer on a regular basis. It is suggested you add defoamer to the flue pan each time you fire the
evaporator or every 5 to 10 minutes.
2. Add defoamer primarily to the flue pan. Modify this only under certain conditions.
3. The estimated usage is as follows: NOTE: This is based on the use of ATMOS 300 Defoamer
Pan Set Width (Inches)
Drops of Defoamer
24
3
30
4
36
4 to 5
40
5 to 6
48
6 to 8
60
7 to 9
72
8 to 11
If using sap that has been concentrated by an RO, use an additional drop for each foot of pan width
4. NEVER add defoamer to the center compartment of the syrup pan. Use one drop at a time in the syrup (draw-
off) compartment only.
Minimize Reversal Effects
Reversal occurs when the boil in the pans is reduced (when firing is inconsistent, end of day, change pan flow direction):
1. Maintain a consistent boil
2. After the last syrup draw of the day, draw “sweet” from the syrup pan into a clean container. This will be added to
the boiling syrup pan at the beginning of the next boil and aid in setting up the gradient. The guideline for the
amount of “sweet” to draw is as follows:
Pan Set Width (Inches)
Gallons of “Sweet”
24
1 to 1 ½
30
1 ½ to 2
36
2 to 2 ½
40
2 ½ to 3 ½
48
3 ½ to 5
60
4 to 7
72
6 to 9

PATRIOT MAX & STANDARD EVAPORATOR PAN SET 2019 Page:
5
EQUIPMENT DESCRIPTION
The PATRIOT set of evaporator pans have dual level controls allowing a deeper level in the syrup pan and a shallower
level in the flue pan. The PATRIOT also offers a flow reversing system comprised of two valves and a single plug. The
pans are constructed of 20 gauge stainless steel.
The LEADER MAX flue pan has an 11-½”flue giving 50% more surface area for more fuel efficient performance with a
higher evaporation rate. It is available as a raised flue or a combination raised and drop flue pan. The LEADER standard
flue pan offers 7 ½”raised flues. Both styles allow for expansion with a parallel flow preheater, a Steam-Away or reverse
osmosis unit.
NOTE: Pictures, sketches and drawings presented in this document are not to scale.
A left feed evaporator is defined, as the regulator float box assembly will be on the left side of the flue pan when
standing facing the firing door. A right feed evaporator is defined, as the regulator float box assembly will be on the
right side of the flue pan when standing facing the firing door.
INCLUDED PARTS:
The Leader PATRIOT Evaporator pan set consists are the following parts:
ITEM
LEADER
ORDER #
DESCRIPTION / PHOTO
ITEM
LEADER
ORDER #
DESCRIPTION / PHOTO
Standard or
MAX Flue Pan
Available
from 2’X4’ to
6’X10’
Syrup Pan
Available in
2’X2’ to 6’X6’
Regulator Box
59078 (For
Right Feed)
59079 (For
Left Feed)
Regulator Packing
(included with
regulator arm)
59065
Float (10-¾” X
5 ½” X 2”)
59025
Hot Sap Float (4” x
8 ½”)
59028
Regulator Z-
arm
59051
Stainless Steel Plug
2”
59013
Flue Brush (for
standard flue
pan)
60061
Flue Brush (for
MAX style flue
pans)
60056
Stainless Steel
Machine Screw
RH ¼-20 X 3”
(qty.: 2)
72454
Stainless Steel Hex
Nut ¼-20 (qty.: 6)
72551
2-3/4” #36 SS
Band Clamps
(qty.: 6)
60049
2” X 2-1/4” Hose
Connection (qty.:
3)
60004
4” X 24”
Ceramic Pan
Gasket
65158
Distribution Pipes
(may already be
installed in flue
pan)

PATRIOT MAX & STANDARD EVAPORATOR PAN SET 2019 Page:
6
ITEM
LEADER
ORDER #
DESCRIPTION / PHOTO
ITEM
LEADER
ORDER #
DESCRIPTION / PHOTO
Distribution
Box (qty.: 2 –
may already be
installed at the
end of the
distribution
pipes))
¾” Stainless Steel
Ball Valve
60104
2’ Wide Pan set:
Qty.: 3
30” Wide and 36”
Wide pan set: Qty.:
1
¾” Close
Stainless Steel
Nipple
72106
2’ Wide Pan
set: Qty.: 3
30” Wide and
36 Wide” pan
set: Qty.: 1
1” Stainless
Steel Ball Valve
60106
1” Close Stainless
Steel Nipple
72111
30” Wide and
above pan set:
Qty.: 2
30” Wide and
above pan set:
Qty.: 2
1 ¼” Stainless
Steel Ball Valve
60108
1 ¼” Close
Stainless Steel
Nipple
72340
40” Wide and
above pan set:
Qty.: 1
40” Wide and
above pan set:
Qty.: 1
There are two angle valve assemblies supplies with the pan set. The following listing of parts are the components for each
1” Stainless
Steel Street
Elbow
72126
1” X 2 ½” Running
Thread Nipple
72118
1” Close
Stainless Steel
Nipple
72111
1” Stainless Steel
Ball Valve
60106
1” Stainless
Steel Special
Street Elbows
72234
1 3/8” Rubber
Washer
760045
1 3/8” Stainless
Steel Washer
760055
1” Stainless Steel
Hex Nut (qty:2)
760065

PATRIOT MAX & STANDARD EVAPORATOR PAN SET 2019 Page:
7
OPTIONAL SETUP ITEMS AND REPLACEMENT PARTS
ITEM
LEADER
ORDER #
DESCRIPTION / PHOTO
ITEM
LEADER
ORDER #
DESCRIPTION / PHOTO
Pan Gasket
Holder
59210
1 ¼” Stainless
Steel Ball Valve
60108
1 ¼”
Stainless
Steel Close
Nipple QTY: 2
72340
1 ¼” Stainless
Steel Tee
72316
½” Stainless
Steel Ball
Valve
60100
½” Stainless
Steel Close
Nipple
72101
1 ¼” to ½”
Stainless
Steel Close
Adapter
72344
Sight Level
60156
Hot Sap Float
(4” x 8 ½”)
59028
Regulator Z-
arm
59051
Thermomete
r 3” or 5”
face, 6” stem
61022
3” Face/6”
Stem
61028
5” Face/6”
Stem
Rail Gasket
65154
(1/2” X 2” X
25’)
65157
(1” X 2” X 25’)
65156 Woven
¼” X 1 ½” X
50’

PATRIOT MAX & STANDARD EVAPORATOR PAN SET 2019 Page:
8
DIAGRAM OF THE PATRIOT EVAPORATOR PAN SET
SETUP OF THE PATRIOT EVAPORATOR PAN SET
NOTE: The following information pertaining to setup of an evaporator is to be considered one suggested method.
Installations should meet all applicable governmental regulations and standards.
RECEIVING YOUR EVAPORATOR:
Upon receipt of the evaporator, it is recommended the following tasks be performed:
1. Protect all incoming materials from damage and the environment. If possible place the evaporator at the
location where it will be setup (See section titled SUGAR HOUSE SETUP).
2. Unpack all materials and check the received materials against the Equipment Description list provided
above.
3. Immediately notify Leader Evaporator or your local dealer if there are questions on the received equipment.
SUGAR HOUSE SETUP:
Prior to setup of the sugar house, it is suggested future needs be considered. The requirements for the setup of the
PATRIOT evaporator may not be adequate if in the future additional or larger equipment will be needed. If assistance is
needed in determining possible future requirements please contact Leader Evaporator Sales or your local dealer.
The following are minimum clearances recommended around the evaporator. When determining the clearances, keep
in mind any additional items/equipment (ex. packaging supplies, canner, table(s), chairs) and where they will be located
in the sugar house:
1. Front of the arch: six (6) feet
a. Allows room for firing and cleaning out of ashes
2. Back of the arch: three (3) feet
a. Allows for cleaning and removal of the stack
3. Sides of the arch: four (4) feet
a. Allows for draw off and movement

PATRIOT MAX & STANDARD EVAPORATOR PAN SET 2019 Page:
9
SETTING UP THE PANS:
NOTES:
All arch side directions are as if you were facing the fire door of the arch.
Prior to setting up the pans, level the arch.
Prior to setting up the pans, insulate the arch per the instructions provided for that arch.
1. Prior to placing the pans on the arch, line the rails and
the top of the baffle(s) with ceramic rail gasket (not
included). Use a utility knife to cut the gasket to make a
square fit with no gaps.
2. Place the flue pan onto the lined baffle and arch rails.
Slide the pan tight to the back collar.
3. Install the drain valve on the right rear corner of the
flue pan:
a. For a 24” to a 36” wide evaporator - Teflon tape
both ends of the ¾” stainless steel close nipple.
Thread a ¾” stainless steel ball valve onto one end
of the nipple. Thread the other end of the nipple
onto the drain coupling of the flue pan. Tighten.
b. For an evaporator over 36” side - Teflon tape both
ends of the 1 ¼” stainless steel close nipple.
Thread a 1 ¼” stainless steel ball valve onto one
end of the nipple. Thread the other end of the
nipple onto the drain coupling of the flue pan.
Tighten.
4. Put two #36 band clamps loosely onto each of three 2” x 2
¼” hose connectors.
5. Place the rubber connectors onto the three regulator
connection pipes on the flue pan with the clamp screws
facing down.
6. Push each of the rubber connectors tight to the flue pan.
Make sure the band clamp closest to the flue pan is over
the flue pan regulator connector pipe and tighten the
band clamp.

PATRIOT MAX & STANDARD EVAPORATOR PAN SET 2019 Page:
10
7. Insert a supplied ¼ - 20 X 3” stainless steel machine screw RH
through each of the mounting holes in the flue pan located
above the regulator box connection pipes. The head of the
screw will be inside the flue pan.
8. Thread a supplied ¼ - 20 stainless steel nut onto each of the
machine screws. Turn the nut towards the flue pan until the
screw is held into position –do NOT tighten the nut.
9. Thread a second supplied ¼ - 20 nut onto each screw and
turn the nut until it is approximately 1 ½” down on the
machine screw.
10. Align the regulator box connections with the rubber
connectors on the flue pan.
11. Tilt the regulator box top slightly away from the flue
pan and while straightening the regulator box, slide the
regulator box connectors into the rubbers connectors
on the flue pan and the machine screws in the flue pan
into the mounts on each side of the regulator box.
12. Thread a supplied ¼ - 20 nut onto each of the machine
screws and finger tighten against the nut on the
machine screw. This will hold the regulator box in
place.
13. Press the regulator box into the rubber connectors.
Ensure the band clamps on each connector are located
over the connector pipe on the regulator box and face
screw down then tighten the clamps.

PATRIOT MAX & STANDARD EVAPORATOR PAN SET 2019 Page:
11
16. Place the pan gasket against the front of the flue pan. If
necessary secure it with tape or optionally use a
LEADER pan gasket holder (Order #59210).
17. Install an angle valve assembly into the couplers located
on the front sides of the flue pan. Thread tape all
stainless steel threads. Make sure the handles open
away from the syrup pan.
18. Thread a 1” hex nut onto the exposed end of each angle
valve assembly. Turn down until the front of the nuts
are lined up approximately with the center of the pan
gasket.
19. Slide the holes in the hot sap float boxes of the
syrup pan over the angle valve assemblies. Push
on the pan in order to compress the pan gasket
in order to install the rail gasket at the front of
the syrup pan.
20. Place a piece of 1” rail gasket cut 4” wider than
the flue pan, in front of the syrup pan to cover
the opening between the syrup pan and the
arch.
14. Tighten the ¼ X 20 nut closest to the flue pan on each
of the machine screws.
15. Move the outside pairs of ¼ X 20 nuts in and out until
the regulator box is level along the narrow edge.
When it is level tighten the outer nut of each pair
against the inner nut.

PATRIOT MAX & STANDARD EVAPORATOR PAN SET 2019 Page:
12
25. Insert the regulator float into the regulator float box. Do not force the regulator arm. The following is one
method of inserting the float:
23. Install a thermometer (not supplied)on each side of the syrup
pan. The thermometers are mounted in the ¼” threaded fittings
near the draw off boxes. Remove the plugs from the fittings in
the pan. Teflon tape the threads on the thermometer and
thread into the fittings. Tighten and rotate the “7” so it is
straight down for easier viewing standing next to the evaporator.
24. Install the draw-off valves so when the valve is open the handle is
away from the pan:
a. For a 2’ wide evaporator - Teflon tape the threads of the fitting
on the bottom of the draw off box located on each side of the
syrup pan. Thread on a ¾” stainless steel ball valve and tighten.
Ensure the final position of the handle allows for easy use.
b. For an evaporator 30” wide or larger - Teflon tape the threads of
the fitting on the bottom of the draw off box located on each
side of the syrup pan. Thread on a 1” stainless steel ball valve
and tighten. Ensure the final position of the handle allows for
easy use
21. While pressing on the front of the syrup pan, slide the 1 –
3/8” rubber washer, 1- 3/8” stainless steel washer over
the exposed end of the stainless steel nipple in the hot sap
float box. Thread a 1” stainless steel hex nut onto the
stainless steel nipple and tighten. In order to square the
pan you may need to turn the stainless steel nut on the
back of the hot sap float box.
22. Thread the special stainless steel elbow onto the end of
the stainless steel nipple in front of the stainless steel nut.
Turn it until the open end is pointed straight down into the
float box. The elbow does not need to be tight but should
be snugged.

PATRIOT MAX & STANDARD EVAPORATOR PAN SET 2019 Page:
13
NOTE: The float should always be positioned so the stem is facing the fork of the regulator arm and the
threaded adjustment rod is at the open end of the fork. When the float stem has been positioned under the
regulator fork, ensure the adjustment collar is under the fork and the threaded rod is seated in the bracket on
the float.
26. Connect the raw sap feed to the flue pan regulator box. The bottom of the feed source should be 6 inches
above the top of the regulator box. It is recommended a shutoff valve be installed between the sap source and
the regulator box. The following is a recommended method of attaching the sap source to the regulator box.
The items for this connection as shown are not included with the evaporator.
a. Turn the float level adjuster until the collar is about
halfway on the rod.
b. Begin inserting the float into the float box while
holding up the regulator arm. The float should be
angled slightly toward the outside of the float box
(away from the flue pan) and lengthwise on end to
be able to slide under the regulator arm. The
regulator arm will be on the flue pan side of the
float stem.
c. Continue to rotate the float downward and under the
regulator arm until the float is resting on the bottom
of the float box. The regulator arm will be on the side
of the float stem.
d. Rotate the float toward the rear of the float box until the regulator
fork will slide around the float stem over the adjustment ring.
Lower the float back to the bottom of the float box.

PATRIOT MAX & STANDARD EVAPORATOR PAN SET 2019 Page:
14
a. Teflon tape:
i. two 1 ¼” stainless steel close nipples
ii. ½” stainless steel close nipple
iii. threaded end of the 1 ¼” stainless steel half nipple
iv. 1 ¼” to ½” stainless steel reducing bushing threads
d. Thread a 1 ¼”to ½” stainless steel reducing bushing into the bottom
of the tee.
e. Thread the ½” stainless steel close nipple into the ½” stainless steel
ball valve.
b. Thread one end of a 1 ¼” close nipple into the threaded coupler on
the end of the regulator box.
c. Thread the 1 ¼” stainless steel “tee” onto the stainless steel nipple
and tighten until the open ends are straight up and down.

PATRIOT MAX & STANDARD EVAPORATOR PAN SET 2019 Page:
15
g. Thread the 1 ¼” stainless steel ball valve onto the end of the close nipple.
h. Thread the 1 ¼” stainless steel half nipple into the other end of the 1 ¼”
stainless steel ball valve.
i. Thread the taped end of the 1 ¼” stainless steel nipple (on the stainless
steel ball valve) into the top of the stainless steel tee.
j. Tighten the parts (half nipple, ball valve, close nipple) into the tee. Make
sure the handle of the ball valve can operate without interference.
NOTE: The half nipple on the top stainless steel ball valve is optional.
k. Connect the sap source tank to the upper ball valve. The bottom of the sap
source tank needs to be a minimum of 6” above the top of the evaporator.
Additional height will be needed if a Steam-Away or a preheater are installed.
Connections can be made between the sap source tank and the evaporator
using PVC or other plumbing approved for potable water.
f. Thread the ½” stainless steel ball valve and nipple
assembly into the adapter in the bottom of the tee and
tighten all parts into the tee (adapter, nipple and ball
valve). . Make sure the handle of the ball valve can
operate without interference.
27. Install the Z-arm into the hot sap float box (See the section on
reversing the flow to determine which box to use). Make sure the
packing is in place in the Z-arm cup. The mounting bracket for the Z-
arm is located under the angle valve assembly in the hot sap float box.
Prior to placing the Z-arm into the bracket, hold it into the installed
position and determine if the end of the elbow will be centered on the
Z-arm. If not then adjust the 1” nuts and the pan gasket compression.

PATRIOT MAX & STANDARD EVAPORATOR PAN SET 2019 Page:
16
30. `All parts have now been installed for the pans. Check to ensure the following connections are properly installed
and tight.
a. 3 hose connectors between the flue pan and the regulator box
b. 2 angle valve assemblies between the flue pan and the syrup pan
c. 2 draw off valves on the syrup pan
d. Drain valve on the flue pan
e. Thermometers
NOTE: Plugs and draw off box float should be set for Left Draw Off (See the Operating the Evaporator section)
28. Place the hot sap float into the hot sap box positioned so the
adjustment finger on the side of the float stem are on the side of the
angle valve assembly.
29. Turn the adjuster handle until the fingers are close to the top of
the float. Place the Z-arm fork so the sides of the fork on either
side of the stem and over the adjustment fingers. Slide the hook
on the other end of the Z-arm into the mounting bracket.

PATRIOT MAX & STANDARD EVAPORATOR PAN SET 2019 Page:
17
NEW PAN CLEAN
The first boil is done to remove any residual materials from the pans and to “season” the bricking and insulation.
NOTE: When using chemicals be sure to read and follow all precautions.
1. Fill the flue pan and syrup pan with a baking soda : water mix (1 pound:200 gallons) to a level of 2 to 3 inches.
2. Check all fittings for leakage. If there is no leakage, insulate around the flue drain with rail gasket material.
3. To season the bricking, start by building a small fire in the fire box and very gradually build to a normal fire.
4. Boil the solution for approximately 30 minutes. Watch the boil carefully and replenish the solution as needed to
ensure the solution in the pans remains at the 2 to 3 inch level using the float.
5. Check all equipment:
a. No leaks at connections and valves
b. Pans are boiling evenly
c. Valves work properly
d. Draft is correct
Draft is correct when:
The boil is the same in the syrup pan front-to-back and side-to-side
The fire door is open the flame, sparks, etc. are drawn toward the rear of the arch.
6. Drain the solution after the evaporator has cooled. CAUTION –ensure the equipment is cool enough to be
safely handled for draining.
7. Check the interior of the arch to ensure insulation and bricking are in place.
8. Refill the pans to the 2 to 3 inch level with clean unsoftened, non chlorinated well or spring water.
9. Boil for 30 minutes during which time adjust the floats down to operating levels. NOTE: if may take 10 to 15
minutes for level adjustments to have full effect. After the evaporator has cooled, drain the pans. CAUTION –
ensure the equipment is cool enough to be safely handled for draining.

PATRIOT MAX & STANDARD EVAPORATOR PAN SET 2019 Page:
18
OPERATING THE EVAPORATOR
NOTE: When operating the evaporator be cautious of hazards such as hot surfaces, hot liquids, sparks, and exposed
flames.
NOTE: You must be aware at all times of the level of sap in all compartments of the pans. If the level drops too low you
can and will damage your pans. If there is too much foam you risk damaging your pans.
NOTE: If you have purchased a scoop or skimmer, do NOT use them to push sap through the evaporator. Doing so will
change the gradient in the evaporator.
1. Check the evaporator
a. Make sure all sap sources are flowing freely i.e. not frozen.
b. Ensure defoamer is usable.
c. Ensure all fittings are tight.
d. Make sure all valves are working properly and the floats are properly positioned.
e. Clean the flues with the flue brush every 8 to 12 hours of boiling.
f. If using a wood fired arch, ensure the open area in the grates is clean and free of material. If necessary,
remove ashes from below the grates.
g. Open stack covers, cupolas and thimbles.
h. Open condensate drains.
2. If this startup is for a new evaporator or for the first time of the season, go to the Section titled MAKING SYRUP.
It is recommended in order to minimize the sugar sand and niter, the flow in the syrup pan be reversed daily or when it
is noted the bubbles from boiling are drawn back down into the compartment as they break (appear like boiling mud).
The following are the instructions for reversing the flow in an PATRIOT evaporator:
SYRUP PAN REVERSAL
Flow reversal in a PATRIOT evaporator is done by changing the position of a stainless steel plug, two valves, the Z-arm
and hot sap float. These plugs control which side of the flue pan the fresh sap enters and which side of the syrup pan
will be the finishing side. The diagrams below illustrate the two possible flows in the pan set.
RIGHT DRAW OFF

PATRIOT MAX & STANDARD EVAPORATOR PAN SET 2019 Page:
19
LEFT DRAW OFF
NOTE: Sap should enter the same side of the flue pan as the syrup is drawn off the syrup pan. Example –if the sap
enters the flue pan on the left side, the syrup draw off will be on the left side.
Plug Position 1
Plug Position 2
Ball Valve 1
Ball Valve 2
Z-Arm and Hot
Sap Float
Draw Off Side
Plugged
Open
Open
Closed
Left
Right
Open
Plugged
Closed
Open
Right
Left
1. Draw off “sweet” from the syrup pan and set aside.
a. “Sweet” is drawn from the draw off side of the syrup pan into a clean container
b. The suggested quantity of “sweet” in the following table. The amount of “sweet” drawn should be
adjusted with experience and the concentration of sap used.
c. Set the “sweet” aside in a covered container
2. Identify which positions your plugs and valves are in as illustrated above and change their locations.
3. Make sure the plugs are seated into the holes and the valves are fully closed/opened.
4. When cool enough to safely handle, move the Z-arm and hot sap float to the hot sap box on the opposite side of
the “new” draw off side of the syrup pan.
Pan Set Width (Inches)
Gallons of “Sweet”
24
1 to 1 ½
30
1 ½ to 2
36
2 to 2 ½
40
2 ½ to 3 ½
48
3 ½ to 5
60
4 to 7
72
6 to 9

PATRIOT MAX & STANDARD EVAPORATOR PAN SET 2019 Page:
20
5. Fire the evaporator and bring the syrup pan to a boil then slowly pour the “sweet” into the “new” draw off side of
the syrup pan.
MAKING SYRUP
1. Open the valve between the sap source and the regulator float box.
Adjust the flue pan regulator box and the syrup pan regulator box floats to set
the sap levels as in the guidelines in the following table.. To set the depth using
the float, turn the adjustment handle on the threaded rod counterclockwise to
raise the sap level and clockwise to lower the sap level.
ARCH
Standard Draft
Forced air or Oil fired
Steam-Away or
Preheater with hood
Reverse Osmosis
Evaporator
Width
Flue Pan
Depth
(inches)
Syrup Pan
Depth
(inches)
Flue Pan
Depth
(inches)
Syrup Pan
Depth
(inches
Flue Pan
Depth
(inches)
Syrup Pan
Depth
(inches
Flue Pan
Depth
(inches)
Syrup Pan
Depth
(inches
2X6 to 3X10
¾
1 ½
No
change
Add ¼
Add ¼
Add ¼
Add ¼
Add ½
3X12 to 4X14
1
1 ¾
No
Change
Add ¼
Add ¼
Add ¼
Add ¼
Add ½
5X14 to 6X16
1 ¼
2
No
Change
Add ¼
Add ¼
Add ¼
Add ¼
Add ½
Note –if you combine evaporator enhancements add the changes together as stated in the table above for the
enhancements added.
2. If this is a new pan set startup or the first startup of the season, put the plug in position 2, close ball valve 1 and
open ball valve 2. Put the Z-arm and float into the right hot sap box. Otherwise change the plug positions as
outlined in the paragraph describing reversal of the syrup pan.
3. Fire the evaporator.
4. As the flue pan starts to boil, add defoamer (based on ATMOS 300) into the flue pan on the float box side.
Recommended quantities to add are in the table that follows. Defoamer should be added close to the inlet from
the float box .Remember the inlet side of the flue pan changes with the reversal of the flow. During boiling add
defoamer every 5 to 10 minutes or each time the arch is fired. Adjust the time as necessary to control the foam.
Pan Set Width (Inches)
Drops of Defoamer
24
3
30
4
36
4 to 5
40
5 to 6
48
6 to 8
60
7 to 9
72
8 to 11
5. If this is the first boil of the season or “sweet” was not saved from a previous boil, skip to the next section.
Table of contents
Other Leader Evaporator Industrial Equipment manuals
Popular Industrial Equipment manuals by other brands

Siemens
Siemens 3VL9400-3M.00 operating instructions

Tyco Electronics
Tyco Electronics KILOVAC EV200 Series quick start guide

REGATRON
REGATRON TopCon TC.LAE Preliminary manual

Armstrong
Armstrong 21 Series quick guide

Eaton
Eaton SL4-PIB Series Instruction leaflet

GESTRA
GESTRA RHOMBUSline MK 45-1 Original Installation Instructions

Vahle
Vahle SMGM-BCC System manual

Klimawent
Klimawent RAK-1000 Use and maintenance manual

Nidec
Nidec LEROY-SOMER LSA 49.1 IC 06 Installation and Maintenance

Unitary products group
Unitary products group P XU-V/G9V-UP Series installation manual

nystrom
nystrom EJ-FLF140 Installation, operation and maintenance manual

Jäger
Jäger Z62-K360.12 S5AM manual