LEAGEND Battery Tester BA106 User Manual
1
BA106
1.1 Tool Description
Up / Down keys: Select upwards or downwards via white UP and DOWN keys.
● Exit key: Exit to previous menu via blue EXIT key.
● ENTER key: Confirm the selection via green ENTER key
● Mini-USB Socket (in the side of the product):
Connect to computer for print via USB cable.
1.2 Product Specifications
1). Display: large, 128*64 easy to read LCD, backlit
2). Operating Temperature: 0 to 50°C (32 to 122 F°)
3). Storage Temperature: -20 to 70°C (-4 to 158 F°)
4). Power—provided via vehicle battery(8-30V DC)
5). Dimensions:
Length Width Height
126 mm ( 4.9”) 76 mm ( 3”) 28mm (1.1”)
6). Weight: 200g
1.3 Cold Cranking Amps Measure Range:
Lithium Ion Battery: Regular Flooded ,AGM Gel battery, EFB battery:
2.3 Accessories Included
1) User Manual -- Instructions on tool operations
2) USB cable -- Provides link to tool and computer for print..
3). CD--- Print software inside.
Measure Standard
Measure Range
CCA
100-2000
BCI
100-2000
CA
100-2000
MCA
100-2000
JIS
26A17--245H52
DIN
100-1400
IEC
100-1400
EN
100-2000
SAE
100-2000
GB
30-220
Measure Standard
Measure Range
CCA
20-1000
BCI
20-1000
CA
20-1000
MCA
20-1000
JIS
26A17—150F51
DIN
20-700
IEC
20-700
EN
20-1000
SAE
20-1000
GB
2-120
LEAGEND Battery Tester BA106 User Manual
2
BA106
2.4 Product Setup
The tool allows you to make the following adjustments and settings:
1) Language: Selects desired language.
2) Contrast adjustment: Adjusts the contrast of the LCD display.
3) Tool information: The tool show the version.
To enter the system setup menu
From main menu, select the System Setup and press ENTER.
3.Operation and Test
After connect the tool to vehicle battery, tester displays the tester model , version and batter voltage.
Tester will display the following contents after press any key.
3.1 Battery test
Now the tester detects the surface charge has been eliminated, turn lights off as prompted, then press ENTER key. The tester will recover
automatic test
Select Battery Type
After the battery charge status selected, tester will prompt to select battery type, i.e. Regular Flooded, Lithium Ion ,AGM
Flat Plate or AGM Spiral, Gel and EFB battery. Press UP/DOWN key to select battery type, then press ENTER key to
confirm
1.Battery Test
2.Cranking Test
3.Charging Test
4.Review Data
5. Print
6.System Setup
Main Menu
1.Regular Flooded.
2. Lithium Ion
3. AGM Flat Plate.
4.AGM spiral
5.GEL
6.EFB
Battery Type
Language
Contrast
Tool Information
System Setup
Voltmeter:
12.40V
LEAGEND Battery Tester BA106 User Manual
3
BA106
Battery System Standard and Rating
BA106 battery tester will test each battery according to the selected system and rating.
Use UP/DOWN key to select according to the actual system standard and rating marked on the battery. Use UP/DOWN key to select
according to the actual system standard and rating marked on the battery. See in the below picture, the arrow indicated location.
CCA: Cold Cranking Amps, specified by SAE&BCI, most frequently used value for starting battery
at 0°F (-18°C).
BCI: Battery Council International standard
CA:Cranking Amps standard, effective starting current value at 0°C
MCA: Marine Cranking Amps standard, effective starting current value at 0°C.
JIS:Japan Industrial Standard, displayed on the battery as combination of the numbers and letters, e.g. 55D23,80D26.
DIN:German Auto Industry Committee Standard
IEC:Internal Electro technical Commission Standard
EN:European Automobile Industry Association Standard
SAE: Society of Automotive Engineers Standard
GB:China National Standard
It takes around 3 seconds to display the battery test result.
Battery Test Result
Battery test result includes 5 types as following:
1) Good Battery 2) Good, Recharge 3) Replace
4) Bad Cell, Replace 5) Charge, Retest
3.2. Cranking Test
Tester prompts as following:
CCA
Select Input
500
CCA
Setting Rate
Start Engine
Cranking Test
RPM Detected
Cranking Test
Time 780ms
Cranking Normal
10.13V
Cranking Test
Health:96% 490CCA
Charge:98% 12.64V
Internal R=6.1mΩ
Rated: 500A
GOOD BATTERY
Health:46% 490CCA
Charge:80% 12.68V
Internal R=18.1mΩ
Rated: 500A
REPLACE
Health:0% 0CCA
Charge:20% 10.64V
Internal R=45.2mΩ
Rated: 500A
BAD CELL,REPLACE
Health:78% 440CCA
Charge:30% 12.20V
Internal R=7.2mΩ
Rated: 500A
GOOD, RECHARGE
Health:39% 310CCA
Charge:20% 12.08V
Internal R=30.1mΩ
Rated: 500A
CHARGE-RETEST
LEAGEND Battery Tester BA106 User Manual
4
BA106
3.3 Charging System
Tester prompts as following:
3.4 Review Data
Choose the function of Review Data and review the history of battery testing result
3.5 Print Data
Choose the function of Print and press ENTER.
Before choose the print data function, it is necessary to connect the tool to the computer via USB cable.
Once all are available, please kindly insert the CD to the computer
1. Install the USB driver firstly.
2. Then open the Print software 3. Choose the COM Port NO.
If there are some data history in print software, please kindly clear them.
4.The Printer of computer will print the testing result via PC
Loaded Testing
****
Charging Test
Increasing RPM to 2500
r/min,keep it 5 seconds.
Press ENTER to continue.
Testing
****
Charging Test
Loaded 14.16V
Unloaded 14.39V
Replace 15mV
Charging Normal
Charging Test
Health:96% 490CCA
Charge:98% 12.64V
Internal R=6.1mΩ
Rated: 500A
GOOD BATTERY

Other Leagend Test Equipment manuals

Leagend BT1000 Technical manual

Leagend

Leagend BT1000 Technical manual

Leagend T86 User manual

Leagend

Leagend T86 User manual

Leagend BA102 User manual

Leagend

Leagend BA102 User manual

Popular Test Equipment manuals by other brands

Huazheng HZ1731 user manual

Huazheng

Huazheng HZ1731 user manual

marposs Testar Quick Read quick start guide

marposs

marposs Testar Quick Read quick start guide

Sanwa AP31 instruction manual

Sanwa

Sanwa AP31 instruction manual

Psiber PINGER PLUS+ user guide

Psiber

Psiber PINGER PLUS+ user guide

Siemens SENTRON 3WL operating instructions

Siemens

Siemens SENTRON 3WL operating instructions

HVTest HT2671 manual

HVTest

HVTest HT2671 manual

FSIP DisChargePlus operating instructions

FSIP

FSIP DisChargePlus operating instructions

LeCroy WaveRunner Xi-A Getting started manual

LeCroy

LeCroy WaveRunner Xi-A Getting started manual

Rohde & Schwarz RTE Series Getting started

Rohde & Schwarz

Rohde & Schwarz RTE Series Getting started

Sealey TA130.V2 instruction manual

Sealey

Sealey TA130.V2 instruction manual

Nex-tech DTW Series user manual

Nex-tech

Nex-tech DTW Series user manual

SybronEndo Vitality Scanner 2006 Instructions & guidelines

SybronEndo

SybronEndo Vitality Scanner 2006 Instructions & guidelines

BK TECHNOLOGIES KAA0608A user guide

BK TECHNOLOGIES

BK TECHNOLOGIES KAA0608A user guide

Tektronix PRISM MPI2-10 Assembly/installation instructions

Tektronix

Tektronix PRISM MPI2-10 Assembly/installation instructions

HC HC1200EB quick start guide

HC

HC HC1200EB quick start guide

Imada MX-500N Series instruction manual

Imada

Imada MX-500N Series instruction manual

Dycon D2330 user manual

Dycon

Dycon D2330 user manual

ETI UAL/CL2 Use and maintenance instructions

ETI

ETI UAL/CL2 Use and maintenance instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.