Menu
1 Important Information
1.1 Security
1.2 Warning
1.3 Disposal Of Old Products And Batteries
2 Install The Lock
2.1 Product List
2.2 Installation Three-dimensional Assembly Drawing
3 Understand The Lock
3.1 Appearance
2.3 Instructions Before Installation
2.4 Bolt Direction Reversing
4 Set Up The Lock
6 Other Functions
7 Basic Parameters
6.1 Restore Factory Settings
6.2 Battery Replacement
6.3 Emergency Power Supply Method
6.4 System Restart
8 Restricted Substances
5 Use The Lock
5.1 Outdoor Locking/Unlocking
5.2 Indoor Locking/Unlocking
4.2 Enter The Management Mode
4.3 Add Unlock Method
4.4 Delete Unlock Method
4.5 Management Settings
4.6 System Settings
4.1 Change Language Fastly
2.5 Installation Video
4.7 Other Settings

Copyright © 2023 Xiamen Leelen Technology Co.,Ltd.All Rights Reserved
Add: LEELEN Building, 780 Tieshan Rd., Jimei District, Xiamen
1019 Wanjiachun Rd., Xiang'an District, Xiamen
Tel : (0086) 592-6157677 E-mail: expo@leelen.com
Fax: (0086) 592-6157677 Web: www.global-leelen.com
LoT Indust Base:
1 Important Information
1.1 Security
Before using this smart lock, please read and understand all
instructions. Damage caused by failure to follow the instructions
is not covered by the warranty
Suggest using accessories specified by our company
Only use the lithium battery configured for this product
Do not disassemble the product forcibly, so as not to sound an
alarm or damage the product
Do not scratch the fingerprint sensor with sharp objects, or it
may cause permanent damage
Do not hang objects on the handle, so as not to affect the normal
use of the door lock
To clean the product, please wipe it with a soft cloth
Do not remove the battery while the device is in operation
Do not expose the product to corrosive substances, so as not to
damage the protective layer of the shell
Please choose a professional engineer to install the door lock, and
follow the company's installation standards, and do not disassemble
or assemble by yourself
After the door lock is installed and debugged, please modify the
default management password set at the factory as soon as possible
and keep the mechanical key properly, and do not disclose the
password information easily
After the door lock triggers the low battery alarm, please replace all
batteries in time and make sure the installation is correct
1.2 Warning
Do not put the battery near the fire, so as not to explode
Do not use an emergency power source that does not
comply with safety regulations to power this product
Do not short-circuit the pole connections of the battery
leads with metal as this may cause an explosion
Make sure to replace by LEELEN, LEELEN authorized
service centers or professionals
Using accessories or components produced by other
manufacturers or not specifically recommended by
LEELEN may invalidate your warranty
Please understand the local electronic product classification
collection system by yourself
Please follow local regulations and do not dispose of old
batteries in normal household waste
Batteries cannot be disposed of with normal household waste
Proper disposal of old products helps avoid potential negative
impacts on the environment and human health
1.3 Disposal Of Old Products And Batteries
T02 V
SMART LOCK

Copyright © 2023Xiamen Leelen Technology Co.,Ltd.All Rights Reserved
Add: LEELEN Building, 780 Tieshan Rd., Jimei District, Xiamen
1019 Wanjiachun Rd., Xiang'an District, Xiamen
Tel : (0086) 592-6157677 E-mail: expo@leelen.com
Fax: (0086) 592-6157677 Web: www.global-leelen.com
LoT Indust Base:
2 Install The Lock
2.1 Product List
This product list is for reference only, and everything is subject to the actual packaging content.
Front Panel
(with silicone pad)
x1
Opening Template
x1 Automatic
lock core
x1
Mechanical
Key
x2
IC Card
x2
Installation Kit
x1
User's Guide
x1
Rear Panel
(with silicone pad)
x1
Accessories
Manual
T02 V
SMART LOCK
4200mAh Battery
x1
(1)
(2)
(3)
(4)
(5)
(6)
(7)
(8)
(11)
(12)
(14)
(15)
(16)
(17)
(18)
(9)
(10)
(13)
2.2 Installation Three-dimensional Assembly Drawing
Knowing the three-dimensional assembly diagram of the installation is conducive to understanding the structure of the lock.
1.Door outer lock assembly (1 set)
2.Carriage screws (1 pcs)
3.Connecting studs (3 pcs)
4.Square pole(1)
5.Lock cylinder (1)
6.Lock cylinder fixing screw (1 pcs)
7.Lock body fixing screws (4 pcs)
8.Lock body(1 pcs)
9.Silicone Pad(1 pcs)
10.Rear cover plate (1 pcs)
11.Connecting screws(1 pcs)
12.Anti-loosening spring (1)
13.Anti-lock paddle (1 pcs)
14.Door lock assembly (1 set)
15.Lithium battery(1)
16.Battery Cover(1)
17.Door inner lock fixing screws (4 pcs)
18.Silicone stopper (2 pcs)

Copyright © 2023 Xiamen Leelen Technology Co.,Ltd.All Rights Reserved
Tel : (0086) 592-6157677 E-mail: expo@leelen.com
Fax: (0086) 592-6157677 Web: www.global-leelen.com
T02 V
SMART LOCK
2.3 Instructions Before Installation
2.3.1 Confirm the door opening direction before installation
Left Door Opening
Push The Door Left
Pull The Door Left
Indoor
Outdoor
Indoor
Outdoor
Right Door Opening
Push the door right
Pull the door right
Lock Body
Bolt Direction
Lock Body
Bolt Direction
Lock Body
Bolt Direction
Lock Body
Bolt Direction
2.3.2Corresponding lock body and bolt direction
Push the door left
Pull The Door Left
Push The Door Right
Pull The Door Right
Indoor
Indoor
Outdoor
Outdoor
Add: LEELEN Building, 780 Tieshan Rd., Jimei District, Xiamen
1019 Wanjiachun Rd., Xiang'an District, Xiamen
LoT Indust Base:
2.4 Bolt Direction Reversing
② Bolt Pops Out
③ Rotate The Bolt
④ Press In The Bolt
The lock body does not distinguish between push in and
pull out. If you need to change the direction (that is, push
in to pull out, or pull out to push in), please adjust the
direction of the bolt before installation. The specific method
is as follows:
① The main bolt remains locked
② Slightly lift outward, the bolt will automatically pop out of
the side panel
③ Rotate the latch 180°
④ Press the bolt into the side panel after swiveling into position
② Slightly Lift Outward
① The Main Bolt Remains Locked
2.5 Installation Video
During the door lock installation process, it is necessary to try
dangerous professional tools, so please be sure to hire a
professional to install it. Before installation, please scan the QR
code on the right, watch and follow the installation video to
complete the installation.

Copyright © 2023 Xiamen Leelen Technology Co.,Ltd.All Rights Reserved
Add: LEELEN Building, 780 Tieshan Rd., Jimei District, Xiamen
1019 Wanjiachun Rd., Xiang'an District, Xiamen
Tel : (0086) 592-6157677 E-mail: expo@leelen.com
Fax: (0086) 592-6157677 Web: www.global-leelen.com
LoT Indust Base:
T02 V
SMART LOCK
3 Lock Appearance
Bottom View Of The Front Panel Rear Panel
Battery Cover
Rear handle
Battery Cover Opening
Anti-lock Button
Front Panel
Password Input Area
Card Identification Area
Fingerprint
Keyhole Cover
Emergency Charging Hole
Confirm Key
Front Handle
Doorbell
Lock Key
Low battery indicator
Camera Module
Settings Button
Speaker Emergency
Power Supply
PIR Module
Unlock Key
Lock Key
4 Set Up The Lock
4.2 Enter Management Mode
4.3 Add Unlock Method
2.Press and hold the # key for 2 seconds,
enter the management password after
hearing the voice prompt, and press # to
confirm.(default password: 951058)
1.Touch the keyboard area with the back
of your hand, the keyboard light will light
up, and wake up the keyboard.
3.After hearing the menu prompt
it means that it has entered the
management mode.
Note: If the management password is the
default password, it is recommended to modify
the management password before performing
other operations.
In Admin Mode:
When adding a user, the door lock will automatically number the
user key, and the user only needs to enter fingerprints,
passwords or cards according to the prompts.
Press to add a user,Press the key to add fingerprints,
and follow the voice prompts to change different angles to enter
fingerprints until it prompts: the operation is successful.
Press to add a user,Press the key to enter to add
a password. After entering the 6-digit password, enter the password
again according to it prompts until the prompt: the operation is
successful.
Press to add a user,Press the key to enter the card
adding put the card in the card recognition area, until it prompts:
the operation is successful.
Long press the key for 10S, the device enters the state of rapid
language switching, at this time the voice will prompt "Language
switching Settings: English press 1, Vietnamese press 2, Thai please 3,
Indonesian press 4, Arabic press 5, hard to hear press #, return press *".
The user presses the corresponding numbers 1-5, and it prompts
:the operation is successful.
4.1 Change Language Fastly
Press the key to delete the unlocking method, enter the user
number according to the voice prompt, press # to confirm, until
it prompts: the operation is successful.
4.4 Delete Unlock Method
In Admin Mode:

Copyright © 2023 Xiamen Leelen Technology Co.,Ltd.All Rights Reserved
Add: LEELEN Building, 780 Tieshan Rd., Jimei District, Xiamen
1019 Wanjiachun Rd., Xiang'an District, Xiamen
Tel : (0086) 592-6157677 E-mail: expo@leelen.com
Fax: (0086) 592-6157677 Web: www.global-leelen.com
LoT Indust Base:
T02 V
SMART LOCK
4.5 Management Settings
4.5.1 Change
management
Password
In Admin Mode:
Press the key to enter the management settings, and then
press the key to modify the management password.
After entering a new 6-digit
management
password, follow the
voice prompts and enter the management password again until
it prompts: the operation is successful.
Press the key to enter the system settings, then press
key to enter the delay lock setting, press the key to enable it,
press the key to disable it, until it prompts: the operation is
successful. Delay lock is enabled by default.
When delayed locking is enabled, the lock tongue will be
automatically activated 15 seconds after the smart lock is
successfully unlocked.
4.5.2 Add
management
Fingerprint
In Admin Mode:
Press the key to enter the management settings, and then
press the keyto add management fingerprints, according to
the voice prompts, change the fingerprints from different angles
until it prompts: the operation is successful.
4.5.3 Delete
management
Fingerprint
In Admin Mode:
Press the key to enter the management settings, and then press
the key to delete the management fingerprint. According to it
prompts, press the # key to confirm until it prompts: the operation is
successful.
4.6 System Settings
4.6.1 Volume Settings
In Admin Mode:
Press the key to enter the system settings, and then press the
key to set the volume. According to the voice prompt, press
to set the treble, press to set the middle tone, press
to set the bass, and press to set the mute. Until the voice
prompt: the operation is successful.
Note: No matter which volume mode is set, the menu indicator
sound, alarm sound, and factory reset prompt sound will always
maintain a medium volume.
Press the key to enter the system settings, and then press the
key to enter the number of illegal unlocking settings.
According to it prompts, enter 5-9 unlocking times, press #
to confirm, until it prompt: the operation is successful.
Note: After the setting is completed, if the user fails to unlock for
more than the above times, an alarm will be triggered.
4.6.2 Number of Illegal Unlocking Settings
In Admin Mode:
4.6.4 Card Encryption Settings
In Admin Mode:
Press the key to enter the system settings, then press the
key to enter the card encryption setting, press the key to
enable it, press the key to disable it, until it prompts:
the operation is successful. Encryption is enabled by default.
4.6.3 Remote Unlocking Settings
In Admin Mode:
Press the key to enter the system settings, then press the
key to enter the demo mode setting, and press the key to
enable it, press the key to disable it, until it prompts:
the operation is successful.Demo mode is disabled by default.
After opening, the use and entry of the card can be more secure
and cannot be copied. After closing, the security level of the card
is reduced, but the applicability is enhanced, such as the door lock
can be opened by copying the card through the mobile phone.
4.6.5 Delay Lock Settings
In Admin Mode:
4.6.6 Residency Alarm Settings
In Admin Mode:
Press the key to enter the system settings, then press the
key to enter the residency alarm settings setting, and press the
key to enable it, press the key to disable it, until it
prompts: the operation is successful.Residency alarm is disabled
by default.
6
4.6.7 Double Verification Settings
In Admin Mode:
Press the key to enter the system settings, then press the
key to enter the double verification settings setting, and press the
key to enable it, press the key to disable it, until it
prompts: the operation is successful.Double verification is disabled
by default.
7

Copyright © 2023 Xiamen Leelen Technology Co.,Ltd.All Rights Reserved
Add: LEELEN Building, 780 Tieshan Rd., Jimei District, Xiamen
1019 Wanjiachun Rd., Xiang'an District, Xiamen
Tel : (0086) 592-6157677 E-mail: expo@leelen.com
Fax: (0086) 592-6157677 Web: www.global-leelen.com
LoT Indust Base:
T02 V
SMART LOCK
4.6.8 Change Language Settings
In Admin Mode:
Press the key to enter the system settings, then press the
key to enter the language change setting, and press the 1~5 key
to select it,it prompts: the operation is successful.Language is
English by default.
8
In Admin Mode:
4.6.9 Demo Mode Settings
4.7.1 Commutation Settings
8
1
2
4.7.2 Mute Mode Settings
To wake up the keyboard, press and hold the 0 key for 2
seconds to enter mute mode, so you can go home at night
without waking up your sleeping family members.
Note: Mute mode will be released when the door lock goes
to sleep or enters management settings. In mute mode, the
video call function is not affected.
Press the key to enter the system settings, then press the
key to enter the demo mode settings setting, and press the
key to enable it, press the key to disable it, until it
prompts: the operation is successful.Demo mode is disabled
by default.
Note: The demo mode option will only appear on the system after
no unlocking credentials are added to the door lock or the factory
settings are restored.
4.7 Other Settings
9
If no unlocking credentials are added to the door lock or after
the door lock is restored to factory settings, press the
key three times in succession, and then press the # key to
confirm. Can enter commutation settings.Then press the
key to switch the right door opening direction; press the
key to switch the left door opening direction.

5.1 Outdoor Locking/Unlocking
5 Use The Lock
Outdoor | Front Panel
Touch the touch area of the keyboard to
wake up the keyboard, enter the password
and press # to confirm. After the verification
is successful, Please push or pull the handle
to open the door within 3 seconds
Put the added card into the card identification
area. After the verification is successful, Please
push or pull the handle to open the door within
3 seconds
Put the added finger on the fingerprint collector.
After the verification is successful, , Please push
or pull the handle to open the door within 3 seconds
If the wrong unlocking credentials (password/card/fingerprint) are entered continuously within 5 minutes, the smart lock will be locked for 90 seconds.
After successful unlocking, if the door is not opened within 5 seconds, the smart lock will re-lock automatically.
Outdoor | Front Panel Outdoor | Front Panel
Push Or
Pull Door
Enter
password
Password Unlocking
Proximity Card Unlock Fingerprint Unlock
Push Or
Pull Door Push Or
Pull Door
Swipe area
Fingerprint
recognition
area
Copyright © 2023 Xiamen Leelen Technology Co.,Ltd.All Rights Reserved
Add: LEELEN Building, 780 Tieshan Rd., Jimei District, Xiamen
1019 Wanjiachun Rd., Xiang'an District, Xiamen
Tel : (0086) 592-6157677 E-mail: expo@leelen.com
Fax: (0086) 592-6157677 Web: www.global-leelen.com
LoT Indust Base:
T02 V
SMART LOCK
Do not leave emergency keys inside the
house. Keep them in a safe and accessible
place for use in extreme situations.
Press and hold the top of the inner key
cover, turn the battery cover left, insert
the key and turn to unlock, push/pull the
handle to open the door.
After closing the door, press the lock key
to lock the door. During this period, you
can click the illuminated 8 button to
activate the arming function.
Outdoor | Front Panel Outdoor | Front Panel
Key Unlock
Lock Key
Push Or
Pull Door Push Or
Pull Door
Key Cover
Lock Key

5.2 Indoor Locking/Unlocking
Copyright © 2023 Xiamen Leelen Technology Co.,Ltd.All Rights Reserved
Add: LEELEN Building, 780 Tieshan Rd., Jimei District, Xiamen
1019 Wanjiachun Rd., Xiang'an District, Xiamen
Tel : (0086) 592-6157677 E-mail: expo@leelen.com
Fax: (0086) 592-6157677 Web: www.global-leelen.com
LoT Indust Base:
T02 V
SMART LOCK
6 Other Functions
6.3 Emergency Power Supply Method
Emergency
Charging Port
Speaker
When the battery voltage is insufficient and cannot be opened
from the outside, you can open the rubber plug of the power
supply port at the bottom of the front panel, connect the power
bank to the emergency power supply port (Type-C), and then use
your fingerprint, password or card to unlock.
6.4 System Restart
If you need to restart the system, you can use a 5V power bank
as an emergency power supply and power on the door lock
through the Type-C interface to restart.
Outdoor
|Front Panel
6.1 Restore Factory Settings
6.2 Battery Replacement
As shown in the figure, after long pressing
the RESET button located on the inner lock
of the door for 5 seconds, according to the
voice prompt, short press the RESET button
within 10s until it prompts "operation is
successful", then the factory settings are
restored successfully.
When the system voice prompts "The battery is low,
please replace the battery", it is necessary to replace
the corresponding part of the battery in time.
Indoor | Rear Panel
RESET Key
Indoor | Rear Panel
Indoor Lock Indoor Unlock
①Click the unlock button, and after hearing
the unlock tone, within 3 seconds, push/pull
the quick release handle to open the door.
②According to the actual unlocking direction,
rotate the quick-open handle to open the door.
③After pressing the emergency door opening
knob, twist the knob to open the door.
Anti-lock knob Anti-lock knob
Unlock Key
Lock Key
①After closing the door, click the
lock button to lock it.
② According to the actual locking
direction, rotate the quick-open
handle to lock.
Rear Handle Rear Handle
Indoor | Rear Panel Indoor | Rear Panel

Copyright © 2023 Xiamen Leelen Technology Co.,Ltd.All Rights Reserved
Add: LEELEN Building, 780 Tieshan Rd., Jimei District, Xiamen
1019 Wanjiachun Rd., Xiang'an District, Xiamen
Tel : (0086) 592-6157677 E-mail: expo@leelen.com
Fax: (0086) 592-6157677 Web: www.global-leelen.com
LoT Indust Base:
T02 V
SMART LOCK
7 Basic parameters
Front panel (L*W*H): 413×79×70mm
Rear panel (L*W*H): 413×79×73mm
Shell Material: Aluminum Alloy + Glass Cover
Lock body type: 6068 standard lock body/Overlord lock body
Input power: 4200mAh Lithium Battery
Emergency power supply interface: Type-C 5V power supply port
Wifi Module:Wi-Fi IEEE 802.11b/g/n 2.4GHz
Working temperature: -25°C~+70°C
Working humidity: 0~93%±3%RH, non-condensing
Protection class: IP52
User capacity:
50 fingerprint (49+1 management)/
50 password groups (49+1 management)/
100 cards
Environmental adaptability level: Level II
Product safety level: Class B
Lock cylinder security level: C level
Suitable for door thickness: standard 50mm~130mm
8 Restricted substances
Toxic and hazardous substances or elements
Part
Name
metal
parts
plastic
parts
Board
Assembly*
Power Cord/
Connection
Cord
Pb Hg Cd Cr6+ PBB PBDE
O O O O O O
OO O O O O
X O O O O O
X O O O O O
This form is prepared according to the provisions of SJ/T 11364:
O: Indicates that the content of the hazardous substance in all
homogeneous materials of the part is below the limit requirement in
GB/T 26572
X: Indicates that the content of the hazardous substance in at least
one homogeneous material of the part exceeds the limit requirement
specified in GB/T 26572
*: Circuit board assembly includes printed circuit board and its
components, such as resistors, capacitors, integrated circuits, etc.
X O OOOO
Lithium
Battery
Table of contents
Other LeeLen Lock manuals