General instrucons and regulaons
Installaon
To qualify for the guarantee, the Lobbe Compact must be installed by a qualied er employed by a
Leenders approved dealer. See leenders.nl for a current list of addresses of approved dealers or con-
tact the factory.
The stove is suscepble to scratching, cauon is recommended.
Stoke the stove aer ng with kindling to check the dra.
Use
• All local regulaons, including those referring to naonal and European standards must be
observed when ng the appliance.
• Ensure ample venlaon / air supply in the room where the stove is installed. Air extracon, such
as an extractor hood, can cause problems in the form of ue gases escaping from the stove into
the room.
• This appliance is not suitable for sharing a ue.
• The appliance must be ed to a wall that can easily support the load.
• Ensure there is ample access for cleaning the equipment, the ue gas connecon and the chimney.
Safety regulaons
• Glass is very fragile and broken glass is very sharp. Take sucient safety precauons.
• For maers of general safety, the appliance and locaon should meet naonal and local installaon
regulaons, local re brigade regulaons and required architectural provisions.
• Please note: that aer installaon no combusble and/or materials with a danger of exploding
should be placed in the stove, like spray cans, packaging materials and such like.
Safe distance for Lobbe Compact from combusble materials
• Rear wall; appliance must be mounted on a non-combusble wall.
• Side walls; 350mm. Temperature during safety test; 54°C
• Front; 1200mm. Temperature during safety test; 47°C
Specicaons Lobbe Compact
• Nominal capacity = 5.2 kWh
• Flue gas mass ow = 5.8 g/s
• Mass appliance = 108 kg
• Minimum chimney draught = 0.12 mbar
• Flue gas temperature directly above the stove = 211 °C
• Energy Eciency: 80.9%, Class A+, index 108.3
+