Lemania Energy LE25.0 User manual


INTRODUCTION
Thank you for purchasing this LEM1224250 Smart Battery Charger. This charger is
compatible with most SLA batteries with capacities ranging from 50Ah-450Ah in 12V
or 25Ah-320Ah in 24V, it may also be used with some WET, GEL and AGM etc. batteries.
Before charging a battery, please refer to your batteries user manual or the manufacturers
charging guidelines. Using a 7 step microprocessor controlled charging program, batteries
can be recharged to almost 100% of their capacity and the charger can be left connected
to the battery in maintenance mode for extended periods. The 16V boost ‘recondition’ mode
can restore life into ‘dead’ batteries and help to break up the sulphate inside increasing
their performance and capacity. The processor controls both the charging programs as
well as the safety of the device as it waits for the battery to be correctly connected before
charging.
FEATURES
01

02EN
WARNING
PLEASE READ AND UNDERSTAND THESE
INSTRUCTIONS BEFORE USING THE SMART CHARGER
WARNING! DO NOT ATTEMPT TO CHARGE A NON-
RECHARGEABLE BATTERY
CAUTION:
-These battery chargers must be used on the horizontal floor or table IN WARNING.
-Never attempt charge batteries that are not compatible with the charger.
-Do not attempt to use the charger to recharge dry or primary cells or batteries that are
not intended for recharging. Doing so could result in fire or explosions that may cause
personal injury or property damage.
-Always ensure that the output voltage and current specifications match the appropriate
battery type.
-Never use the charger under reverse polarity conditions.
-Suitable for indoor use only.
-The manufacturer assumes no liability for damage resulting from unauthorized or
incorrect use.
-Do not attempt to charge more than one battery at a time in 12V.
-Do not attempt to charge frozen batteries, doing so can be extremely dangerous.
-Do not attempt to charge batteries that show signs of damage as this may cause fires or
explosions.
-Do not attempt to use the charger in damp conditions, submerge or expose the device to
running water or rain.
-Only use the charger in a well-ventilated environment, do not attempt to charge
batteries in sealed or pressurized areas.
-Never attempt to use the charger near volatile or flammable substances or while it is
placed on a battery as gasses released during charging may cause explosions or damage
to the charger.
-Do not place the charger on warm surfaces or cover the charger or battery during
charging and ensure that all ventilation slots are clear during operation.
-Do not attempt to start a vehicle while the charger is connected.
-Before carrying out maintenance or work when you are not using the charger ensure
that it is disconnected.
-Prevent short circuits and make sure not to bridge terminal connections while
connecting the charger to the battery.
-Connect the charger to the battery terminals only in accordance with the instructions.
Never connect the charger in a different or reverse order and make sure to use
appropriate tools when loosening or removing terminal connectors.
-Do not touch the battery terminals, clamps, or ring terminals when the charger is
connected to a power source.

03
-Before connecting the charger to a vehicle ensure that the battery has been
disconnected. Removing the battery during charging is recommended.
-If the battery is not removed from the vehicle or disconnected then:
The battery terminal not connected to the chassis has to be connected first. The other
connection is to be made to the chassis, remote from the battery and fuel lines. The
battery charger is then to be connected to the mains supply.
After charging, disconnect the battery charger from the mains supply. Then remove the
chassis connection and then the battery connection.
-Do not attempt to use the charger if it has suffered a hard knock or fall, if it appears to
be damaged or malfunctioning in any way. Contact your distributor for further assistance.
-Do not under any circumstances attempt to disassemble or repair the charger yourself
and contact your distributor if any assistance is required. Do not insert foreign objects
into the charger
-Before using the charger ensure that it is in good condition and has not been damaged
in any way.
-Do not lift or carry the device by pulling on the power cables and keep the power cables
away from sources of heat, oil or sharp edges during charging and storage.
-If a power cable is damaged, do not use the charger and contact your distributor for
further assistance.
-When using or storing the charger, keep the charger out of reach of children or pets.
-The charger can be used by children aged from 8 years and above and by persons with
reduced physical sensory or mental capabilities or lack of experience and knowledge if
they have been given supervision or instruction concerning the use of the charger in a
safe way and understand the hazards involved.
-Children shall not play with the appliance. Cleaning and user maintenance shall not be
made by children without supervision.
-Store the charger in a dry, clean, well-ventilated environment and ensure cables are
stored safely and correctly.
-If possible do not use extension cables. Improper use of extension cables can result in
fire or electrical shocks. If use of an extension cable is absolutely necessary ensure that
the connectors are of the same shape, size and number of pins as the charger. Ensure
that the cable is in good condition, is not frayed or has exposed wiring and is of good
quality. -Batteries contain lead and acid that can be dangerous in contact with skin or
eyes causing burns or blindness. Lead is dangerous during pregnancy.
-In case of contact with skin rinse the area immediately with water and neutralize the
acid with a mild alkaline solution such as milk. If exposed to electrolyte, rinse the area
with a strong stream of water. In all circumstances seek the assistance of a medical
professional.
-In case of contact with the eyes, rinse with clean water for at least 10 minutes while
waiting for the assistance of a medical professional.
-To prevent electrostatic discharges do not use the charger while wearing clothing made
of synthetic materials.
WARNING

04EN
SPECIFICATIONS
Input Voltage 220-240VAC, 50/60Hz.
Power Consumption 135W
Input Current 1.2A RMS. Max
Cut off Voltage 28.8V±2% or 29.4V±2% or 14.4V±0.25V or 14.7±0.25V or
13.6V±0.25Vor 16.5V±0.5V
Charging Current 25A±10% or 12.5A±10% or 5.0A±10% or 1.5A±0.5A
Trickle Current 1.5A±0.5A, interval ±1second
Ripple 150mV Max.
Battery Type (Lead Acid) 12V Lead acid battery: 50Ah~450Ah;
24V Lead acid battery: 25Ah~230Ah.
IP Rating IPX4
Audible Noise <50dB (Test from 500mm distance)
Operating Temperature 0oc to +40oc
Fuse 10A
LED ON POWER ON/STANDBY MODE
LED ON MODE 1 - CHARGING 24V
LED ON MODE 1.1 - COLD/AGM 24V
LED ON MODE 2 - CHARGING 12V
LED ON MODE 2.1 - COLD/AGM 12V
LED ON MODE 3 - SUPPLY
LED FLASHING
FAST MODE 4 - BOOST
LED FLASHING
SLOW MODE 4 - BOOST IN PROGRESS
LED ON MODE 4 - BOOST COMPLETED

05
Charging Function:
All modes are intended to charge or recondition batteries with a capacities ranging from
50-450Ah (12V battery) 25-230Ah (24V battery) under normal conditions
Charge LED – These four LEDs are labeled left to right 25%, 50%, 75%, 100%. These LEDs
indicate the state of charge once the battery is charged and the 100% LED is illuminated
the charger will go into maintenance mode automatically.
1. STAND BY
When connected to the mains power the charger stays in standby mode until a battery is
connected or a program is selected by the user.
1.1 Battery Voltage Detection
•Once the charger is connected to both the battery and the AC power input it will run an
initial test to determine the voltage of the connected battery.
•12V batteries are compatible with Mode 2, Mode 2.1 and mode 3. The Mode button can be
used to cycle between these programs.
•24V batteries are compatible with Mode 1 and Mode 1.1. The Mode button can be used to
cycle between these programs.
2. MODE 1 (28.8V/12.5A) 24V Battery
Connect the positive and negative clamps to the terminals of the battery, ensure that the
polarity is correct, then connect the AC power and press the MODE button to select .
If no other action is taken the charger will start the charging process at 12.5A±10%.
The 100% LED will illuminate when the battery is fully charged to 28.8V±0.58% and the
charger will go into maintenance mode automatically and keep the battery fully charged
using a <1.0A trickle current and 1.5A maintenance charge. Under sub zero temperatures,
the built in temperature sensor will automatically change the charging program to
apply a higher voltage (29.4V 12.5A) to the battery. In this phase the and LEDs will
illuminate. Once the battery is fully charged to 28.8V±0.58V the 100% LED will illuminate
and the charger will go into maintenance mode automatically and keep the battery fully
charged using a <1.0A trickle current and 1.5A maintenance charge.
2.1 MODE 1.1 (28.8V/12.5A) 24V AGM Battery
Charging AGM Batteries: AGM batteries must be charged at a higher voltage during
normal conditions. To charge an AGM battery connect the positive and negative clamps
to the terminals of the battery, ensure that the polarity is correct, then press the MODE
button until both and are illuminated. If no further action is taken the charger will
automatically start to charge with a current of 12.5A±10%.at 29.4V. Once the battery is
fully charged to 29.4V±0.59V the charger will go into maintenance mode automatically
and keep the battery fully charged using a <1.0A trickle current and 1.5A maintenance
charge.
MODES

06EN
MODES
3. MODE 2 (14.4V/25A) 12V Battery
Connect the positive and negative clamps to the terminals of the battery, ensure that the
polarity is correct, then connect the AC power and press the MODE button to select .
If no other action is taken the charger will start the charging process at 25A±10% The
100% LED will illuminate when the battery is fully charged to 14.4V±0.25V and the charger
will go into maintenance mode automatically and keep the battery fully charged using a
<1.0A trickle current and 1.5A maintenance charge. Under sub zero temperatures, the built
in temperature sensor will automatically change the charging program to apply a higher
voltage (14.7V 25A) to the battery. In this phase the and LEDs will illuminate. Once
the battery is fully charged to 14.7V±0.29V the 100% LED will illuminate and the charger will
go into maintenance mode automatically and keep the battery fully charged using a <1.0A
trickle current and 1.5A maintenance charge
3.1 MODE 2.1 (14.4V/25A) 12V AGM Battery
Charging AGM Batteries: AGM batteries must be charged at a higher voltage during
normal conditions. To charge an AGM battery connect the positive and negative clamps
to the terminals of the battery, ensure that the polarity is correct, then press the MODE
button until both and are illuminated. If no further action is taken the charger will
automatically start to charge with a current of 25A±10%.at 14.7V. Once the battery is fully
charged to 14.7V±0.29V the charger will go into maintenance mode automatically and keep
the battery fully charged using a <1.0A trickle current and 1.5A maintenance charge.
4. MODE 3 13.6V SUPPLY (13.6V/5.0A)
Connect the positive and negative clamps to the terminals of the battery, ensure that the
polarity is correct, then connect the AC power and hold the MODE button for more than
3 seconds. The LED will illuminate, and the charger will start the supply program at
13.6V±0.5V constant voltage and 5A±10% constant current. If the voltage drops to 12.0V or
below, the charger will automatically cut off and return to standby mode.
5. MODE 4 16V boost (16V/1.5A) 12V battery only
This mode is used to recondition batteries with a capacity from 50-450Ah under normal
conditions. Warning! The high voltage applied in this mode may cause some water loss, for
optimal results the battery must be disconnected from the vehicle. Connect the positive
and negative clamps to the terminals of the battery, ensure that the polarity is correct,
then connect the AC power and press the MODE button to select . If no other action
is taken the charger will then start the reconditioning program at 16.5V±0.5V and 1.5A±0.5A.
If the battery is deeply discharged and sulphated the reconditioning program may continue
for up to 4 hours at which point if the battery is not able to reach 13.6V the process will
terminate. If the battery reaches 13.6V then the charger will automatically switch to the
12V charging mode.

07
6. Pulse Rescue Dead Battery
At the start of the charging program the charger detects the battery voltage and
automatically starts the pulse charging program if the voltage is between 4.5V±0.29V to
10.5V±0.29V (12V battery) or 15V±0.5V to 21V±0.42V (24V battery).This process will continue
until the battery voltage reaches 10.5V±0.29V (12V battery) or 21V±0.42V (24V battery), once
the battery reaches these levels the charger will continue according to the selected
program.
7. Abnormality Protection
The charger will automatically protect itself if it detects abnormal conditions such as,
short circuit, 12V battery voltage below 4.5±0.5V, 24V battery voltage below 15V±0.25V,
open circuit or reverse polarity connection. When any of these conditions are detected
the charger will return to standby mode . In addition to this will illuminate if the
connections to the battery are reversed.
9. Changing between modes.
To change mode, press the MODE button until the desired. Once the mode button is
pressed, after 0.5 seconds the charger will change its mode.
a. 12V batteries are compatible with the following modes: Standby, Mode 2, Mode 2.1, Mode
3 and Mode 4. The charger will cycle in this order. Please note that to access model 3 the
charger must be powered, not connected to the battery and the mode button must be
pressed for 3 seconds. Once this is complete the charger can be connected to the battery,
ensuring that the connections are correct as polarity protection is disabled.
b. 24V batteries are compatible with the following modes: Standby, Mode1. Mode 1.1. The
Charger will cycle in this order.
If a battery is not disconnected from the charger once fully charged, the charger will
remain in the trickle charging mode even if the user attempts to change the mode
manually. This protects fully charged batteries from damage.
10. Charging status indication
MODES
LED 25% LED 50% LED 75% LED 100% Charging Status
Flashing OFF OFF OFF Under 25%
ON Flashing OFF OFF Under 50%
ON ON Flashing OFF Under 75%
ON ON ON Flashing Under 100%
ON ON ON ON Fully Charged
11. Memory function
This Smart Battery charger has a unique memory function (not applicable to the 13.6V
Supply and 16V boost mode). The charger returns to last selected mode automatically
when power is switched on after a cut in AC power.

08EN
OPERATING INSTRUCTIONS
Please read these instructions carefully before using the smart charger.
1. Before attempting to charge a battery, ensure that the terminals are clean. Remove any
corrosion if present and make sure that any of the removed materiel does not contact the
eyes.
2. Ensure that the area around the battery is well ventilated as explosive gasses may
be released during charging. There must be no sources of ignition, sparking wires, open
flames or other anywhere near the battery.
3. If the battery is of the AutoFill type, manufactured by Dagenite or Exide for example, the
glass halls and long filler cap must be left in place during charging.
4. Connect the clamps in the following order
a. First connect the positive clamp (red color) to the positive terminal post.
b. Second connect the negative clamp (black color) to the negative terminal post or to the
chassis remote from the battery and fuel line.
5. Connect the charger to the mains supply, it will turn on, detect the battery voltage, and
start the charging process automatically. If the clamps are incorrectly connected the fault
indicator will illuminate, repeat step 4 correctly.
6. If a mode other than charging is required, press the mode button until the desired mode
is selected. Note: to select the 13.6V continuous supply mode the mode button must be
held for more than 3 seconds when the clamps are not connected to the battery Warning!
Reverse polarity protection is disabled in this mode.
7. If a battery is not fully charged after a maximum of 75 hours, the charger must be
disconnected manually.
8. When the charger is no longer needed disconnect the battery charger from the mains
supply then remove the chassis or negative post connection and finally the positive post
connection. Store the charger safely.
ABNORMALITY PROTECTION FEATURE
If the charger remains in bulk mode for more than 41 hours (416Ah cut-off) then the fault
indicator will illuminate. As with other failure conditions, all other LDS will flash at a 5hz
interval and the charger will output no current. This prevents any damage to the battery.
HSF requirement –RoHS, REACH, 16PAHs<200ppm
Safety requirement –EN60335-2-29, EN60335-1, EN62233 standard for Safety, EN55014-1,
EN55014-2, EN61000-3-2, EN61000-3-3 Standard for EMC test without loading terminal
test.
WARRANTY INFORMATION:
The warranty of this unit depends on the conditions granted by your retailer. The
manufacturer shall have no liability whatsoever at any time for any warranty, personal
injury or property damage. Transport is never included.
Please dispose of the packaging in a responsible manner. It should be recycled by
your local amenity or placed in appropriate recycling bins. Never dispose of electrical
equipment or batteries in your domestic waste. Have them recycled by your retailer or
your local amenity. WWW.LEMANIA-ENERGY.COM

09
ADVANCED DIAGNOSTICS
The Smart Charger will indicate error conditions to the user by a series of blinking LED
lights. Based on the order and frequency the user will be able to ascertain the potential
reason for the error condition. The table below describes the charger’s diagnostic and
error conditions.
SEQUENCE MESSAGE
Error LED, 25%, 50%, 75%
& 100% LEDs: All LEDs
will flash on and off at a
5hz interval.
Battery will not hold charge:
1.The battery may have been damaged, deeply discharged
or drained
2.The batteries actual capacity is too low (nominal
capacity<50Ah 12V or 25Ah 24V)
3.Nominal capacity of battery meets with the specified
range, but the actual capacity is far below the specified
capacity range
4.Internal resistance of the battery is too high.
Bulk charge timeout
1.The batteries capacity is too high, actual capaci-
ty>>450Ah 12V or 230Ah 24V
2.Battery carry high power load during charging, battery
can’t be fully charged by bulk charge timeout charging,
3.Possible Battery plate short circuit.
Failure LED is “on” solid;
no blinking
Reverse polarity
Standby Mode The battery is under 4.5±0.1V in any mode (except for
Supply Mode)
Abnormality protection
In the case of a short circuit, open circuit, reversed polarity connection or battery
voltage below 4.5V±0.10V (for 12V battery), or 15V±0.5V (for 24V battery), the charger will
automatically turn off the charge or supply program and will immediately reset the
system back to standby mode to avoid damage to the battery or charger. Under reverse
polarity connection conditions, the LED will illuminate to indicate an error.
Temperature protection
During the charging program, if the charger is too hot, it will reduce the output power or
cut off the power automatically to protect itself from damage.

10EN
ADVANCED DIAGNOSTICS
Q: If the battery does not reach a voltage of 13,6V after 4 hours of BOOST CHARGE, the LED
keeps blinking. Why?
A: If the LED keeps blinking it is to notify the user of an abnormal battery state. The battery
cannot be recovered even after Boost Charge.
Q: After 4 hours of BOOST CHARGE, if the battery can reach 13,6V. Does the charger
automatically switch to the NORMAL CHARGE mode? Or should it be done manually?
A: If the battery is recovered after the BOOST CHARGE, it will automatically continue to
charge following a Normal Charge program.
Q: Can the charger be connected to a small capacity 12V battery of 25- 40Ah? What will
happen, can the charger be used to recharge smaller batteries?
A: As the max output of the charge is 25A, if it is connected to a small capacity battery,
the battery voltage will rise quickly due to the fast absorption and internal resistance. The
charger may indicate that the battery is fully charged or abnormal even if not fully charged.
The 7A charger would be more suited for these smaller batteries.
Q: After connecting the charger to the battery, after a few seconds or minutes the charger
indicates that it is fully charged, and all LEDs are ON. Is the battery already fully charged?
A: If such a battery has normal characteristics however the actual capacity is very low,
the charger will indicate it is fully charged in a short period of time shortly even the actual
capacity is still very low. Try the Boost mode for 4 hours.
Q: If the charger is connected to a large battery (120-250Ah) and is recharging correctly,
the 20%, 50%, 75% LEDs are ON, and the 100% is blinking. The Charger has even been left
overnight. What might be the problem? Is the charger not charging the battery or is the
battery not able to be charged to 100%?
A: If the light 100% is blinking, the charger is on the absorption step. The charging current
in absorption step drops to ~1.5A. As such if the battery capacity is large / has a high self-
discharge rate / the battery is loaded, the absorption step can take a long time. In effect the
battery is already charged to more than 80% and can be used normally.
Q: If the charger is connected to a large 24V battery and starts recharging automatically but
recognizes the battery as 12V. Why does it start in 12V?
A: The charger has an inbuilt ability to detect 12V or 24V batteries. It will make sure that
12V batteries are not charged in 24V, to prevent damage from occurring. Under special
conditions, a 24V battery may mislead the charger to recognize it as a 12V battery: if it is
overly discharged between 5V-14.7V, The battery voltage remains at 12V and increases by
less than 2V during the 2-minute analysis period. This abnormal condition will not cause any
safety issues or result in damage to the battery or charger however the charger will not be
able to fully charge the battery.
Q: Is the temperature sensor used to detect the temperature of the Charger or the Battery?
A: The temperature sensor used to detect the battery and environment temperature, the
charger will use the battery temperature to adjust the charging program.

11
CHARGING CURVES
12V Battery Charging Curve
*For Cold/AGM mode the voltage will be 14.7V instead of 14.4V
24V Battery Charging Curve
*For Cold/AGM mode the voltage will be 29.4V instead of 28.8V

10FR
INTRODUCTION
Merci pour l’achat de ce chargeur intelligent LEM1224250. Ce chargeur est compatible
avec la plupart des batteries SLA avec des capacités allant de 50Ah-450Ah en 12V ou
25Ah-320Ah en 24V, il peut également être utilisé avec certaines batteries WET, GEL ,AGM
etc. Avant de charger une batterie, merci de vous référer au manuel d’utilisation de votre
batterie ou aux instructions de charge du fabricant. En utilisant un programme de charge
en 7 étapes contrôlé par microprocesseur, les batteries peuvent être rechargées jusqu’à
quasiment 100% de leur capacité et le chargeur peut rester connecté à la batterie en
mode maintenance pendant de longues périodes. Le mode reconditionnement 16V permet
de restaurer les batteries à plat et aider à décomposer le sulfate à l’intérieur, augmentant
ainsi leurs performances et capacités. Le processeur contrôle à la fois les programmes de
charge et la sécurité de l’appareil car il attend que la batterie soit correctement connectée
avant de charger.
CARACTÉRISTIQUES
12FR

ATTENTION
13
VEUILLEZ VOUS ASSUREZ DE LIRE ET COMPRENDRE
CES INSTRUCTIONS AVANT D’UTILISER LE
CHARGEUR INTELLIGENT.
ATTENTION! N’ESSAYEZ PAS DE CHARGER UNE
BATTERIE NON RECHARGEABLE
MISE EN GARDE:
-Ces chargeurs de batterie doivent être utilisés sur le sol à l’horizontal ou sur une table
AVEC ATTENTION.
-Ne tentez jamais de charger des batteries qui ne sont pas compatibles avec le chargeur.
-Ne tentez jamais d’utiliser le chargeur pour recharger des cellules sèches ou primaires ou des
batteries qui ne sont pas destinées à être rechargées. Cela pourrait créer un incendie ou des
explosions susceptibles de causer des blessures corporelles ou des dommages matériels.
-Assurez-vous toujours que la tension de sortie et les spécifications du courant
correspondent au type de batterie.
-N’utilisez jamais le chargeur dans des conditions de polarités inversées.
-Convient pour une utilisation à l’intérieur uniquement.
-Le fabricant ne peut être tenu pour responsable concernant les dommages résultant
d’une utilisation non autorisée ou incorrecte.
-N’essayez pas de charger plus d’une batterie à la fois en 12V.
-N’essayez pas de charger des batteries gelées, cela pourrait être extrêmement dangereux.
-N’essayez pas de charger des batteries présentant des signes d’altération car cela
pourrait causer des incendies ou explosions.
-N’essayez pas d’utiliser le chargeur dans des conditions humides, de l’immerger ou
d’exposer l’appareil à l’eau courante ou la pluie.
- Utilisez uniquement le chargeur dans un environnement bien ventilé, n’essayez pas de
charger des batteries dans un endroit clos ou pressurisé.
-Ne tentez jamais d’utiliser le chargeur à proximité de substances volatiles ou
inflammables ou lorsqu’il est placé sur une batterie car les gaz libérés pendant la charge
peuvent provoquer des explosions ou endommager le chargeur.
-Ne placez pas le chargeur sur des surfaces chaudes, ne couvrez pas le chargeur ou la batterie
pendant la charge et assurez vous que toutes les fentes de ventilations soient dégagées.
-N’essayez pas de démarrer un véhicule lorsque le chargeur est connecté.
-Avant d’effectuer des travaux de maintenance sur le chargeur, assurez vous qu’il soit
déconnecté.
-Evitez les courts-circuits et veillez à ne pas établir de liaison entre les bornes de la
batterie lorsque vous connectez le chargeur à la batterie.
-Connectez le chargeur aux bornes de la batterie uniquement conformément aux
instructions. Ne connectez jamais le chargeur dans un ordre différent ou inverse et assurez
vous d’utiliser les outils appropriés lorsque vous desserrez ou retirez les bornes de la batterie.
-Ne touchez pas les bornes de la batterie, les pinces ou les cosses lorsque le chargeur

14FR
ATTENTION
est connecté à une source de courant.
- Avant de connecter le chargeur à un véhicule, assurez vous que la batterie ait été
déconnectée. Il est recommandé de retirer la batterie pendant la charge.
-Si la batterie n’est pas retirée du véhicule ou déconnectée alors :
La borne qui n’est pas connectée au châssis doit être connectée en premier. L’autre
connexion doit être faite au châssis, à distance de la batterie et des conduites de carburant.
Le chargeur doit ensuite être branché au secteur.
Après la charge, débranchez le chargeur du secteur. Puis retirez la connexion au châssis
puis la connexion à la batterie.
-N’essayez pas d’utiliser le chargeur s’il a subit un choc ou une chute, s’il parait endommagé
ou s’il présente un dysfonctionnement quel qu’il soit. Contactez votre distributeur pour plus
d’assistance.
-N’essayez en aucun cas de démonter ou réparer le chargeur vous-même et contactez votre
distributeur si vous avez besoin d’assistance. N’insérez pas d’objets étrangers dans le chargeur.
-Avant d’utiliser le chargeur, assurez vous qu’il soit en bon état et n’a pas été endommagé
de quelque manière que ce soit.
-Ne soulevez pas et ne transporter pas l’appareil en tirant sur les câbles d’alimentation et
gardez les câbles d’alimentation loin de toute source de chaleur, d’huile ou bords tranchant
lors de la charge et du stockage.
-Si un câble d’alimentation est endommagé, n’utilisez pas le chargeur et contactez votre
distributeur pour plus d’assistance.
-Gardez le chargeur hors de la portée des enfants et des animaux lors de l’utilisation ou du stockage.
-Le chargeur peut être utilisé par des enfants âgés de 8 ans et plus et par des personnes avec
des capacités physiques sensorielles ou mentales réduites ou avec un manque d’expérience
et de connaissances si ils sont sous surveillance ou ont reçu des instructions concernant
l’utilisation du chargeur de manière sûre et comprennent les dangers impliqués.
-Les enfants ne doivent pas jouer avec l’appareil. Le nettoyage et l’entretien ne doivent pas
être faits par des enfants sans surveillance.
-Stockez le chargeur dans un environnement sec, propre et bien ventilé et veillez à ce
que les câbles soient rangés correctement et en sécurité.
-Si possible, n’utilisez pas de rallonge. Une mauvaise utilisation des rallonges peut
provoquer un incendie ou des chocs électriques. Si l’utilisation d’une rallonge est
absolument nécessaire, assurez vous que les connecteurs aient la
même forme, la même taille et le même nombre de fiches que le chargeur. Veillez à ce
que le câble soit en bon état, ne soit pas effiloché ou dénudé et soit de bonne qualité.
-Les batteries contiennent du plomb et de l’acide qui peuvent être dangereux au contact de la
peau et des yeux causant des brûlures ou la cécité. L’acide est dangereux durant la grossesse.
-En cas de contact avec la peau, rincez immédiatement la zone avec de l’eau et
neutralisez l’acide avec une solution alcaline douce telle que le lait. En cas d’exposition à
l’électrolyte, rincez la zone avec un jet d’eau puissant. Dans tous les cas, demandez l’aide
d’un professionnel de santé.
-En cas de contact avec les yeux, rincez avec à l’eau claire pendant au moins 10 minutes
en attendant l’aide d’un professionnel de santé.
-Afin d’éviter toute décharge électrostatique n’utilisez pas le chargeur si vous portez des
vêtements en matière synthétique

15
SPECIFICATIONS
Tension d’entrée 220-240VAC, 50/60Hz.
Consommation d’énergie 135W
Courant d’entrée 1.2A RMS. Max
Tension de coupure 28.8V±2% ou 29.4V±2% ou 14.4V±0.25V ou 14.7±0.25V ou
13.6V±0.25V ou 16.5V±0.5V
Courant de charge 25A±10% ou 12.5A±10% ou 5.0A±10% ou 1.5A±0.5A
Courant de maintien de
charge
1.5A±0.5A, intervalle ±1seconde
Ondulation 150mV Max.
Type de batterie 12V batterie plomb/acide: 50Ah~450Ah;
24V batterie plomb/acide: 25Ah~230Ah.
Degré de résistance à la
poussière et à l’eau (IP)
IPX4
Bruit audible <50dB (Test à 500mm de distance)
Temperature de
fonctionnement
0oc to +40oc
Fusible 10A
LED ALLUMÉE EN MARCHE/MODE STANDBY
LED ALLUMÉE MODE 1 - CHARGE 24V
LED ALLUMÉE MODE 1.1 - FROID/AGM 24V
LED ALLUMÉE MODE 2 - CHARGE 12V
LED ALLUMÉE MODE 2.1 - FROID/AGM 12V
LED ALLUMÉE MODE 3 - ALIMENTATION
LED CLIGNOTANT
RAPIDEMENT MODE 4 - BOOST
LED CLIGNOTANT
LENTEMENT MODE 4 - BOOST EN COURS
LED ALLUMÉE MODE 4 - BOOST COMPLET

16FR
MODES
Fonction de charge:
Tous les modes sont conçus pour charger ou reconditionner les batteries avec des
capacités de 50-450Ah (batterie 12V) 25-230Ah (batterie 24V) dans des conditions
normales.
Témoins de charge lumineux – Ces quatre LED sont étiquetées de gauche à droite
de 25%, 50%, 75% à 100%. Ces LED indiquent l’état de charge. Une fois que la
batterie est chargée et que le témoin lumineux 100% s’allume, le chargeur se mettra
automatiquement en mode maintien de charge.
1. VEILLE
Lorsqu’il est connecté au secteur, le chargeur reste en mode veille jusqu’à ce qu’une
batterie soit connectée ou qu’un programme soit sélectionné par l’utilisateur.
1.1 Détection du voltage de la batterie
•Une fois le chargeur connecté à la fois à la batterie et au secteur il démarrera un test
initial afin de déterminer le voltage de la batterie à laquelle il est connecté.
•Les batteries 12V sont compatibles avec le Mode 2, le Mode 2.1 et le Mode 3. Utilisez le
bouton Mode pour naviguer entre ces programmes.
•Les batteries 24V sont compatibles avec le Mode 1 et le Mode 1.1. Utilisez le bouton Mode
pour naviguer entre ces programmes.
2. MODE 1 (28.8V/12.5A) Batterie 24V
Connectez la pince positive et la pince négative aux bornes de la batterie, assurez vous
que la polarité soit correcte, puis branchez l’alimentation et appuyez sur le bouton MODE
pour sélectionner . Si aucune autre action n’est menée, le chargeur démarrera le
processus de charge à 12.5A±10%. Le témoin lumineux 100% s’allumera lorsque la batterie
sera complètement chargée à 28.8V±0.58% et le chargeur passera automatiquement
en mode maintien de charge et gardera la batterie complètement chargée en utilisant
un courant de maintien <1,0 A et une charge de maintien de 1,5 A. Par une température
en dessous de zéro, le capteur de température intégré changera automatiquement
le programme de charge afin d’appliquer une tension plus élevée (29.4V 12.5A) à la
batterie. Dans cette phase, les témoins lumineux et s’allumeront. Une fois la
batterie complètement chargée à 28.8V±0.58V, le témoin lumineux 100% s’allumera et le
chargeur passera automatiquement en mode maintien de charge et gardera la batterie
complètement chargée en utilisant un courant de maintien <1,0 A et une charge de
maintien de 1,5 A.
2.1 MODE 1.1 (28.8V/12.5A) Batterie AGM 24V
Charger des batteries AGM: les batteries AGM doivent être chargées à une tension plus
élevée dans des conditions normales. Pour charger une batterie AGM, connectez les
pinces positive et négatives aux bornes de la batterie, assurez vous que la polarité soit
correcte, puis appuyez sur le bouton MODE jusqu’à ce que et soient allumés. Si

17
aucune autre action n’est menée, le chargeur démarrera automatiquement la charge avec
un courant de 12.5A±10%.à 29.4V. Une fois la batterie complètement chargée à 29.4V±0.59V,
le chargeur passera automatiquement en mode maintien de charge et gardera la batterie
complètement chargée en utilisant un courant de maintien <1,0 A et une charge de
maintien de 1,5 A.
3. MODE 2 (14.4V/25A) Batterie 12V
Connectez les pinces positive et négative aux bornes de la batterie, assurez vous
que la polarité soit correcte, puis branchez l’alimentation et appuyez sur le bouton
MODE afin de sélectionner . Si aucune autre action n’est menée, le chargeur
démarrera le processus de charge à 25A±10%. Le témoin lumineux 100% s’allumera
lorsque la batterie sera complètement chargée à 14.4V±0.25V et le chargeur passera
automatiquement en mode maintien de charge et gardera la batterie complètement
chargée en utilisant un courant de maintien <1.0A et une charge de de maintien à 1.5A.
Par une température en dessous de zéro, le capteur de température intégré changera
automatiquement le programme de charge afin d’appliquer un voltage plus élevé (14.7V
25A) à la batterie. Dans cette phase les témoins lumineux et s’allumeront. Une
fois la batterie complètement chargée à 14.7V±0.29V le témoin lumineux s’allumera et le
chargeur passera automatiquement en mode maintien de charge et gardera la batterie
complètement chargée en utilisant un courant de maintien <1.0A et une charge de de
maintien à 1.5A.
3.1 MODE 2.1 (14.4V/25A) Batterie AGM 12V
Charger des batteries AGM: les batteries AGM doivent être chargées à une tension plus
élevée dans des conditions normales. Pour charger une batterie AGM, connectez les
pinces positive et négatives aux bornes de la batterie, assurez vous que la polarité soit
correcte, puis appuyez sur le bouton MODE jusqu’à ce que et soient allumés. Si
aucune autre action n’est menée, le chargeur démarrera automatiquement la charge avec
un courant de 25A±10%.at 14.7V. Une fois la batterie complètement chargée à 14.7V±0.29V,
le chargeur passera automatiquement en mode maintien de charge et gardera la batterie
complètement chargée en utilisant un courant de maintien <1.0A et une charge de de
maintien à 1.5A.
4. MODE 3 13.6V ALIMENTATION (13.6V/5.0A)
Connectez les pinces positives et négative aux bornes de la batterie, assurez vous que
la polarité soit correcte, puis branchez l’alimentation et maintenez le bouton MODE
enfoncé pendant plus de 3 secondes. Le témoin lumineux s’allumera et le chargeur
démarrera le programme d’alimentation avec une tension constante de 13.6V±0.5V et un
courant constant de 5A±10% . Si la tension retombe à 12V ou en dessous, le chargeur se
coupera automatiquement et se remettra en mode veille.
5. MODE 4 16V boost (16V/1.5A) batterie 12V uniquement
Ce mode est utilisé pour reconditionner les batteries avec une capacité de 50-450Ah dans
MODES

18FR
MODES
des conditions normales. Attention ! La tension élevée appliquée dans ce mode peut
causer des pertes d’eau, pour des résultats optimaux la batterie doit être déconnectée
du véhicule. Connectez les pinces positive et négative aux bornes de la batterie, assurez
vous que la polarité soit correcte, puis branchez l’alimentation et appuyez sur le bouton
MODE afin de sélectionner . Si aucune autre action n’est menée, le chargeur
démarrera alors le programme de reconditionnement à 16.5V±0.5V et 1.5A±0.5A. Si la
batterie est profondément déchargée et sulfatée le programme de reconditionnement
pourra continuer jusqu’à 4 heures, stade auquel si la batterie n’a pas réussi à
atteindre 13.6V le processus s’achèvera. Si la batterie atteint 13.6V alors le chargeur va
automatiquement basculer vers le mode de charge
6. Récupération par impulsions des batteries déchargées
Au démarrage du programme de charge, le chargeur détecte le voltage de la batterie et
démarre automatiquement le programme de charge par impulsions si la tension se situe
entre 4.5V±0.29V et 10.5V±0.29V (batterie 12V) ou 15V±0.5V et 21V±0.42V (batterie 24V).
Ce processus continuera jusqu’à ce que la tension de la batterie atteigne 10.5V±0.29V
(batterie 12V) ou 21V±0.42V (batterie 24V). Une fois que la batterie a atteint ce niveau, le
chargeur poursuivra selon le programme sélectionné.
7. Protection contre les anomalies
Le chargeur s’auto-protègera automatiquement s’il détecte des conditions anormales
telles que courts-circuits, une tension de batterie 12V en dessous de 4.5±0.5V, une tension
de batterie 24V en dessous de 15V±0.25V, un circuit ouvert ou une inversion de polarité.
Lorsque l’une de ces conditions est détectée, le chargeur se remettra alors en mode
veille . De plus, s’allumera si les connexions à la batterie sont inversées.
8. Protection contre la surchauffe
Si le chargeur devient trop chaud lorsque l’un des modes est actif, il réduira sa puissance
de sortie afin de se protéger des dommages.
9. Changer de mode
Pour changer de mode, appuyez sur le bouton MODE jusqu’au mode souhaité. Une fois le
bouton pressé, le chargeur changera de mode après 0.5 secondes.
a.Les batteries 12V sont compatibles avec les modes suivants : Veille, Mode 2, Mode 2.1,
Mode 3 et Mode 4. Le chargeur effectuera un cycle dans cet ordre. Veuillez noter que
pour accéder au mode 3 le chargeur doit être sous tension, non connecté à la batterie
et le bouton mode doit être maintenu enfoncé pendant 3 secondes. Une fois ces
étapes effectuées, le chargeur peut être connecté à la batterie, en vous assurant que
les connexions soient correctes car la protection contre les inversions de polarité est
désactivée dans ce mode.
b.Les batteries 24V sont compatibles avec les modes suivants : Veille, Mode1. Mode 1.1. Le
chargeur effectuera un cycle dans cet ordre.
Si une batterie n’est pas déconnectée du chargeur une fois qu’elle est complètement

19
MODES
11. Fonction mémoire
Ce chargeur de batterie intelligent a une fonction de mémoire unique (non applicable
aux modes alimentation 13.6V et boost 16V). Le chargeur retournera automatiquement au
dernier mode sélectionné lorsque l’alimentation électrique est rétablie après une coupure
de courant
chargée, le chargeur restera en mode maintien de charge même si l’utilisateur tente de
changer le mode manuellement. Cela protège la batterie chargée des dommages.
10. Indication des status de charge
LED 25% LED 50% LED 75% LED 100% statut de charge
Clignotant Eteinte Eteinte Eteinte en dessous de 25%
Allumée Clignotant Eteinte Eteinte en dessous de 50%
Allumée Allumée Clignotant Eteinte en dessous de 75%
Allumée Allumée Allumée Clignotant en dessous de 100%
Allumée Allumée Allumée Allumée complètement chargé
Merci de lire ces instructions avec attention avant d’utiliser le chargeur intelligent.
1.Avant d’essayer de charger une batterie, veillez à ce que les bornes soient propres.
Retirez toute corrosion et assurez vous que la matière retirée n’entre pas en contact avec
les yeux.
2.Veillez à ce que la zone autour de la batterie soit bien ventilée car des gaz explosifs sont
susceptibles d’être libérés pendant la charge. Veillez à maintenir la batterie à l’écart de
toute flamme ou étincelles.
3.Si la batterie est de type Autofill, fabriquée par Dagenite ou Exide par exemple, les
bouchons des conduits de remplissage doivent être maintenus en place pendant la
charge.
4.Connectez les pinces dans cet ordre :
a.Connectez d’abord la pince positive (couleur rouge) à la borne positive.
b.Ensuite connectez la pince négative (couleur noire) à la borne négative ou au châssis, à
distance de la batterie et de la conduite de carburant..
5.Connectez le chargeur au secteur. Il va s’allumer, détecter le voltage de la batterie, et
démarrer le processus de charge automatiquement. Si les pinces ne sont pas connectées
correctement, le voyant de panne va s’allumer. Répétez alors l’étape 4 correctement.
INSTRUCTIONS D’UTILISATION
Table of contents
Languages:
Other Lemania Energy Automobile Accessories manuals