
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
2
TABLE OF CONTENTS
Packaging .........................................Page 2
Introduction ......................................Page 2
General Information ..........................Page 2
Location............................................Page 4
Appliance Clearances ........................Page 4
Fireplace Specifications.....................Page 5
Gas Vent Rule ...................................Page 5
Framing Specifications......................Page 6
Typical Installation Sequence ............Page 6
Installing The Fireplace .....................Page 7
Vent System Installation ...................Page 8
Field Wiring.......................................Page 8
Connecting Gas Line .........................Page 10
Outside Air Kit Installation.................Page 10
Installing Logs .................................Page 11
Appliance Operation..........................Page 16
Millivolt Appliance Checkout .............Page 16
Electronic Appliance Checkout..........Page 16
Installing Glass Door.........................Page 16
Burner Adjustments ..........................Page 17
Spillage Test......................................Page 17
Manual Limit Switch .........................Page 17
Hood Installation...............................Page 17
Finishing Requirements ....................Page 18
Cold Climate Insulation .....................Page 18
Installation Accessories ....................Page 18
Gas Conversion Kits .................. Page 19
This installation manual will help you obtain a
safe, efficient, dependable installation for your
appliance and vent system.
Please read and understand these
instructions before beginning your
installation.
PACKAGING LIST
The assembled vented gas fireplace is pack-
aged with:
1 - One log set located in firebox area.
2 - One envelope containing the literature
package which consists ofthe homeowner's
manual, installation instructions, log set
supplement and warranty; envelope is
located in the control area.
3 - One hood located behind the top panel.
4 - One bag of decorative volcanic stone located
in the control area.
5 - One bag of glowing embers (rockwool)
located in the control area.
INTRODUCTION
These vented gas fireplaces are designed to
operate on either natrural or propane gas. They
must be installed with approved type-B, double
wall vent pipe systems routed to the outside
atmosphere.
The Millivolt appliances have a millivolt gas
control valve withpiezo ignition system provides
safe, efficient operation. If any optional acces-
sories which require electrical power are being
installed, the electrical power must be provided
at the time of appliance installation.
The Electronic appliances have an electronic
intermittent pilot ignition system provides safe,
efficient operation. External electrical power is
required to operate these units.
These appliances comply with National Safety
Standards and are tested and listed by OMNI-
Test Laboratories, Inc. (Report No. 116-F-36-5)
to ANSI Z21.50 (in Canada, CSA 2.22), and
CAN/CGA-2.17-M91 in both USA and Canada,
as vented gas fireplaces.
Misc. Codes / Standards -
The Installation must conform to local codes or,
in the absence of local codes, with the National
Fuel Gas Code, ANSI Z223.1/NFPA 54 - latest
edition, or the Natural Gas and Propane Instal-
lation Code, CSA B149.1 - latest edition.
The appliance, when installed, must be electri-
cally grounded inaccordance with local codesor,
in the absence of local codes, with the National
Electrical Code, ANSI/NFPA 70 - latest edition,
or the Canadian Electrical Code, CSA C22.1
- latest edition.
DO NOT ATTEMPT TO ALTER OR MODIFY
THECONSTRUCTION OF THEAPPLIANCE
OR ITS COMPONENTS. ANY MODIFICA-
TION OR ALTERATION MAY VOID THE
WARRANTY, CERTIFICATION AND LIST-
INGS OF THIS UNIT.
Massachusetts -
Installation of these fireplaces are approved for
installation in theUS state of Massachusettsif the
following additional requirements are met -
• Installation and repair must be done by a
plumber or gas fitter licensed in the Com-
monwealth of Massachusetts.
• The flexible gas line connector used shall not
exceed 36 inches (92 centimeters) in length.
• The individual manual shut-off must be a
T-handle type valve.
New York City, New York -
Installation of these fireplaces are approved for
installation in New York City in the US state of
New York (approval no. MEA 417-05-E), if the
following additional requirements are met -
• An outside air kit (FOAK-4 or FOAK-4LD)
must be installed. See Figure 1a and Page
18 for ordering information.
GENERAL INFORMATION
Note: Installation and repair should be per-
formed by a qualified service person. The
appliance should be inspected annually by a
qualified professional service technician. More
frequent inspections and cleanings may be
required due to excessive lint from carpeting,
bedding material, etc.
It is imperative that the control compartment,
burners and circulating air passageways of the
appliance be kept clean.
S'assurer que le brùleur et le compartiment des
commandes sont propres. Voir les instructions
d'installation et d'utilisation qui accompagnent
l'apareil.
Provide adequate clearances around air open-
ings and adequate accessibility clearance for
service and proper operation. Never obstruct
the front openings of the appliance.
Figure 1a
WARNING
Improper installation, adjustment,
alteration, service or maintenance
can cause injury or property
damage. Refer to this manual. For
assistanceoradditionalinformation
consultaqualifiedinstaller,service
agency or the gas supplier.
Vertical
Venting
Shown with Outside Air Kit
installed (model FOAK-4 or
FOAK-4LD)
NEW YORK CITY, NY AND MASSA-
CHUSETTS REQUIREMENTS
These appliances are approved for installation
in the following USA locations listed in the
following: