Page 4
General Information 
The CBA25UHE series air handler with  all-aluminum 
coil is designed for indoor installation in conditioned or 
unconditioned spaces. As shipped, the unit is ready for 
installation  in  either  upow,  horizontal  left-hand  or  right-
hand  air  discharge  applications.  Electric  heat,  downow 
air  discharge  kits,  air  lters  and  other  accessories  are 
available and listed in the CBA25UHE Product Specica-
tion bulletin for ordering.
This instruction is intended as a general guide and does 
not supersede local or national codes in any way. Consult 
authorities having jurisdiction before installation. 
 CAUTION
As with any mechanical equipment, contact with sharp 
sheet metal edges can result in personal injury. Take 
care while handling this equipment and wear gloves and 
protective clothing.
Requirements 
 WARNING
Excessive Weight Hazard - Use two or more people 
when moving and installing the unit. Failure to do so can 
result in back or other type of injury.
 IMPORTANT
CBA25UHE units include a factory-installed check/
expansion valve which will provide optimal refrigerant 
control and system performance with outdoor units of 
varying capacities. These units must be installed as a 
part of a matched system as outlined in the CBA25UHE 
Product Specication bulletin.
These instructions are intended as a general guide and do 
not supersede local or national codes in any way. Consult 
authorities having jurisdiction before installation. 
Compliance with all local, state, or national codes pertain-
ing to this type of equipment should be determined prior 
to installation. Read this instruction manual, as well as the 
instructions supplied in separate equipment, before start-
ing the installation. 
In addition to conforming to manufacturer’s installation in-
structions and local municipal building codes, installation 
of Lennox air handler units (with or without optional elec-
tric heat), MUST conform with National Fire Protection As-
sociation (NFPA) standards: “Standard for Installation of 
Air Conditioning and Ventilation Systems” (NFPA No. 90A) 
and “Standard for Installation of Residence Type Warm Air 
Heating and Air Conditioning Systems” (NFPA No. 90B). 
All models are designed for indoor installation only. The 
installation of the air handler, eld wiring, duct system, etc. 
must conform to the requirements of the National Electri-
cal Code, ANSI/NFPA No. 70 (latest edition) in the United 
States, and any state laws, and local ordinances (includ-
ing plumbing or waste water codes). 
Local authorities having jurisdiction should be consulted 
before installation is made. Such applicable regulations or 
requirements take precedence over the general instruc-
tions in this manual. 
Install  the  conditioned  air  plenum,  ducts  and  air  lters 
(provided) in accordance with NFPA 90B Standard for the 
Installation of Warm Air Heating and Air-Conditioning Sys-
tems (latest edition). 
The air handler is shipped from the factory completely as-
sembled. The unit is provided with anges for the connec-
tion of the duct system. 
Do not remove the cabinet knockouts until it has been de-
termined which knockouts will need to be removed for the 
installation. 
Select the air discharge position which best suits the site 
conditions. Consider required clearances, space, routing 
requirements for refrigerant line, condensate disposal, 
lters,  duct  system,  wiring,  and  accessibility  for  service. 
Refer to the rating plate on the air handler for specic in-
formation.
 WARNING
Danger  of  explosion.  Keep  ammable 
materials and vapors, such as gasoline, away 
from air handler. Place air handler so that 
heating elements are at least 18 inches (46 
cm) above the oor for a garage installation. 
Failure to follow these instructions can result 
in death, explosion, or re.
 IMPORTANT
Excessive condensation may occur if the unit is installed 
in a warm, humid place. When the unit is installed in 
an unconditioned space, apply sealant around electrical 
wires, refrigerant piping and condensate lines at the 
point where they enter the cabinet.
This will help prevent air leakage into, and condensation 
from forming inside of, the air handler, the control box, 
and on the electrical controls. 
 IMPORTANT
This unit is approved for installation clearance to 
combustible material as stated on the unit rating 
plate. Accessibility and service clearances must take 
precedence over combustible material clearances.
The air handler must be installed so that free access is 
allowed to the coil/lter compartment and blower/control 
compartment.