3
CONGRATULATIONS ON THE PURCHASE OF YOUR NEW GAS APPLIANCE MANU-
FACTURED BY LENNOX HEARTH PRODUCTS.
When you purchased your new gas-fired fireplace, you joined the ranks of thousands of individuals
whose answer to their home heating needs reflects their concern for efficiency and our environment.
We extend our continued support to help you achieve the maximum benefit and enjoyment available
from your new gas-fired fireplace. It is our goal at Lennox Hearth Products to provide you, our
valued customer, with an appliance that will ensure years of trouble-free warmth and pleasure.
Thank you for selecting a Lennox Hearth Products gas-fired fireplace as the answer to your home
supplemental heating needs.
Sincerely, All of us at Lennox Hearth Products
It is imperative that the control compartment,
burners and circulating air passage ways of
appliance be kept clean. See Maintenance
instructions on Page 6.
S'assurer que le brùleur et le compartiment des
commandes sont propres. Voir les instructions
d'installation et d'utilisation qui accompagnent
l'appareil.
Provide adequate clearances around air open-
ings and adequate accessibility clearance for
service and proper operation. Never obstruct
the front openings of the appliance.
Duetohightemperaturestheapplianceshould
belocatedoutoftrafficandawayfromfurniture
and draperies. Locate furniture and window
coverings accordingly.
These fireplaces are designed as supplemental
heaters. Therefore, it is advisable to have
an alternate heat source when installed in a
dwelling.
These appliances are designed to operate on
natural or propane gas only.
Millivolt Models -
Input of millivolt models is shown in the fol-
lowing table:
Electronic Models -
Electronic models have a modulating gas valve.
Input of electronic models is shown in the fol-
lowing table:
INTRODUCTION
The fireplace models covered in this manual
are direct-vent sealed combustion gas fireplace
heaters designed for residential application.
Direct-vent appliances operate with the com-
bustion chamber completely isolated from the
indoor environment. All air for combustion is
brought in from the outside and exhaust gases
areventedthroughthesame directvent,co-axial
(intake/exhaust) vent system.
The millivolt appliances are designed to operate
on either natural or propane gas. A millivolt gas
controlvalvewithpiezoignitionsystemprovides
safe, efficient operation. If any optional acces-
sories which require electrical power are being
installed, the electrical power must be provided
at the time of appliance installation.
The electronic appliances are designed to op-
erate on either natural or propane gas (if field
converted). An electronic intermittent pilot
systemwhichprovidessafe,efficientoperation.
External electrical power is required to operate
these appliances.
These appliances comply with National Safety
Standards and are tested and listed by OMNI-
Test Laboratories (Report No. 116-F-48-5)
to ANSI Z21.88 (in Canada, CSA-2.33), and
CAN/CGA-2.17-M91 in both USA and Canada,
as vented gas fireplace heaters.
The Installation must conform to local codes or
in the absence of local codes, with the National
FuelGasCode,ANSIZ223.1/NFPA54-latestedi-
tion,or the NaturalGas andPropaneInstallation
Code,CSA B149.1-latestedition. Theappliance,
when installed, must be electrically grounded in
accordance with local codes or, in the absence
of local codes, the latest edition of the National
Electrical Code, ANSI/NFPA 70, or the Canadian
Electrical Code, CSA C22.1.
GENERAL INFORMATION
Note: Installation and repair should be per-
formed by a qualified service person. The
appliance should be inspected annually by a
qualified professional service technician. More
frequent inspections and cleanings may be
required due to excessive lint from carpeting,
bedding material, etc.
TABLE OF CONTENTS
Safety and Warning Information .......Page 2
Introduction ......................................Page 3
General Information ..........................Page 3
Operation/Care of Your Appliance .....Page 4
Gas Controls Access .........................Page 4
Variable Flame Adjustment................Page 5
Maintenance......................................Page 5
Front Glass Enclosure Panel,
Removal and Installation.................Page 7
Burner Flame Appearance & Sooting Page 8
Burner Flame Adjustments................Page 8
Install Embers & Logs.......................Page 9
Millivolt Appliance Checkout .............Page 11
Electronic Appliance Checkout..........Page 11
Accessory Components ....................Page 11
Wiring Diagrams...............................Page 14
Warranty ...........................................Page 14
Product Reference Information.........Page 14
Lighting Instructions – Millivolt ........Page 15
Lighting Instructions – Electronic .....Page 17
Troubleshooting Guide – Millivolt......Page 19
Troubleshooting Guide – Electronic ..Page 20
Replacement Parts List .....................Page 21
Input (BTU/HR) Manually-Modulated Gas
Valves (millivolt models)
Model NATURAL GAS
(BTU / HR)
PROPANE GAS
(BTU / HR)
ADAGIO-MN 13,000 high
10,000 low -------------
ADAGIO-MP ------------- 13,000 high
10,000 low
Table 1
Input (BTU/HR) Electronic Models
Model NATURAL GAS
(BTU / HR)
PROPANE GAS
(BTU / HR)
ADAGIO-EN 13,000 high
10,000 low -------------
ADAGIO-EP
if field converted ------------- 13,000 high
10,000 low
Table 2
Table 3 shows the units' gas orifice size for
the elevations indicated.
Model Orifice Size Elevation
Feet
Nat. Prop.
ADAGIO .067"
(#51)
.042"
(#58) 0-4500
(0-1372)
Table 3