Installations at Altitudes of 0 to 4500 feet -
Unitsaretestedandapprovedforelevations
of 0 to 4500 feet (0 to 1370 meters).
Installations at Altitudes above 4500 ft.-
For elevations above 4500 feet (1370
meters), install the unit according to the
regulations of the local authorities having
jurisdiction and, in the USA, the latest
editionof theNational FuelGas Code(ANSI
Z223.1) or, in Canada, the latest edition of
the CAN-B149.1 and CAN-B149.2 codes.
Table 4 shows the units' gas orifice size for
the elevations indicated:
LOCATION
In selecting the location, the aesthetic and
functional use of the appliance are primary
concerns. However, vent system routing to
the exterior and access to the fuel supply are
also important. Considerationshould be given
to traffic ways, furniture, draperies, etc., due
to elevated surface temperatures.
Considerations Should Include:
• Existing Chimneys
• Aesthetic Considerations
• Roof Design (Rafter Locations and Roof Pitch)
• Room Traffic
• Proximity to Combustibles
• Proximity for Optimum Heat Transfer
• Electrical Wiring (if optional blower is installed)
The installation of this stove will require some
research. Once your options are determined,
consult with your localbuilding department who
will be able to give youthe necessary installation
requirements for your area (Is a building permit
required?, Rooms where installation may not
be allowed?, etc.).
Tables 2 and 3 show the units' gas pressure
requirements:
Inlet Gas Supply Pressure
(all models)
Fuel # Minimum Maximum
Natural Gas 4.5" WC
(1.12 kPa)
10.5" WC
(2.61 kPa)
Propane 11.0" WC
(2.73 kPa)
13.0" WC
(3.23 kPa)
Table 2
Manifold Gas Supply Pressure
(millivolt models)
Fuel # Low High
Natural
Gas
(Lo) 1.6" WC
(.40 kPa)
(Hi) 3.5" WC
(.87 kPa)
Propane (Lo) 6.3" WC
(1.57 kPa)
(Hi) 10.0" WC
(2.49 kPa)
Table 3
Ne pas se servir de cet appareil s'il a été
plongé dans l'eau, complètement ou en
partie. Appeler un technicien qualifié pour
inspecter l'appareil et remplacer toute partie
du système de contrôle et toute commande
qui ont été plongés dans l'eau.
This appliance may be installed in an
aftermarket permanently located, manu-
factured home (USA only) or mobile
home, where not prohibited by local codes.
Cet appareil peut être installé dans un
maison préfabriquée (É.-U. seulement) ou
mobile déjà installée à demeure si les
réglements locaux le permettent.
Test gauge connections are provided on
the front of the millivolt gas control valve
(identified IN for the inlet and OUT for the
manifold side).
These appliances and their individual shut-off
valves must be disconnected from the gas
supply piping system during any pressure
testing of that system at pressures in excess
of 1/2 psig (3.5 kPa).
These appliances must be isolated from the
gas supply piping system (by closing their
individual manual shut-off valve) during any
pressure testing of the gas supply piping
system at test pressures equal to or less than
1/2 psig (3.5 kPa).
These appliances must not be connected to
a chimney or flue serving a separate solid
fuel burning appliance.
WARNING:Thisappliancemustbeproperly
connected to a venting system. Operation
ofthisgas appliancewhennotconnected to
aproperlyinstalledandmaintainedventing
system can result in carbon monoxide (CO)
poisoning and possible death.
Carbon Monoxide Poisoning: Early signs
of carbon monoxide poisoning are similar
to the flu with headaches, dizziness and/or
nausea.Ifyouhavethesesigns,obtainfresh
air immediately. Turn off the gas supply
to the appliance and have it serviced by
a qualified professional, as it may not be
operating correctly.
The millivolt appliances are manually con-
trolled and feature a spark igniter (piezo)
that allows the appliance's pilot gas to be
lit without the use of matches or batteries.
This system provides continued service in
the event of a power outage.
Do not use these appliances if any part
has been under water. Immediately call a
qualified,professionalservicetechnicianto
inspecttheapplianceandtoreplaceanyparts
of the control system and any gas controls
which have been under water.
Burner Orifice Sizes
Model
No.
Nat.
Gas
Prop.
Gas
Elevation
Feet
(meters)
CI1500DVF .104" .061" 0-4500
(0-1372)
CI2500DVF .121" .068" 0-4500
(0-1372)
Table 4
WARNING
Failuretocomplywiththeinstal-
lationandoperatinginstructions
provided in this document will
resultinan improperly installed
and operating appliance, void-
ing its warranty. Any change
to this appliance and/or its
operatingcontrolsisdangerous.
Improper installation or use of
thisappliancecancauseserious
injury or death from fire, burns,
explosion or carbon monoxide
poisoning.
WARNING
Do not place clothing or other
flammable materials on or near
this appliance.
WARNING
Children and adults should be
alerted to the hazards of high
surface temperatures. Use
caution around the appliance
to avoid burns or clothing igni-
tion. Young children should be
carefully supervised when they
are in the same room as the
appliance.
Note: An Optional Screen Panel
for the glass is available (see
HomeownersManualforordering
information).
AVERTISSEMENT
Surveiller les enfants. Garder les
vêtements,les meubles, l'essence
ou autres liquides à vapeur inflam-
mables lin de l'appareil.