Notice to New Zealand Users
Conexant RD01-D850 Data Fax PCI Modem -PTC 211/03/066
1. The grant of aTelepermit for any item of terminal equipment indicates only that Telecom has
accepted that the item complies with minimum conditions for connection to its network. It indicates
no endorsement of the product by Telecom, nor does it provide any sort of warranty. Above all, it
provides no assurance that any item will work correctly in all respects with another item of
Telepermitted equipment of adifferent make or model, nor does it imply that any product is
compatible with all of Telecom’s network services.
2. This equipment is not capable, under all operating conditions, of correct operation at the higher
speeds for which it is designed. Telecom will accept no responsibility should difficulties arise in such
circumstances. This condition typically applies to 56 kbit/s modems.
3. This equipment does not fully meet Telecom’s impedance requirements. Performance limitations may
occur when used in conjunction with some parts of the network. Telecom will accept no responsibility
should difficulties arise in such circumstances.
4. The equipment shall not be set up to make automatic calls to Telecom’s 111 Emergency Service.
5. This device may be subject to ringing or bell tinkle when certain other devices are connected to the
same line. If this occurs, the problem should not be referred to the Telecom Faults Service.
6. This equipment should not be used under any circumstances that may constitute anuisance to other
Telecom customers.
7. Some parameters required for compliance with Telecom’s Telepermit requirements are dependent on
the application software. The application software shall be set to operate within the following limits
for compliance with Telecom’s specifications:
vThe S0 register must contain avalue of 0for no auto-answer or avalue of 3to 8for auto answer.
The factory default is 3.
vThe S6 register must contain avalue of 4, 5, 6or 7. The factory default of 4is recommended.
vThe S7 register must contain avalue of less than 80. The factory default is 60.
vThe S10 register must contain avalue of less than 140. The factory default is 14.
vThe S11 register must contain avalue of greater than 60. The factory default is 85.
vThere shall be no more than 10 call attempts to the same number within any 30-minute period for
any single manual call initiation.
vThe equipment shall go on-hook for aperiod of not less than 30 seconds between the end of one
call attempt and the beginning of the next attempt to the same number.
vAutomatic calls to different numbers shall be not less than 2seconds apart.
vFailure to set these parameters correctly could negate the User Rights under the Telecom Terms of
Service.