manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Lighthouse Worldwide Solutions
  6. •
  7. Respiratory Product
  8. •
  9. Lighthouse Worldwide Solutions H210 N95 User manual

Lighthouse Worldwide Solutions H210 N95 User manual

H210 N95
Particulate Respirator
User Instructions
IMPORTANT: Keep these user
instructions for reference.
248083502-1 R3
HOW TO WEAR:
1. Turn the respirator so that you are looking at the
back side.
2. Pull up on the nose piece and down on the chin
pieces to create an opening.
3. Place the respirator on your face so that the center
of the nose piece wire is against the bridge of your
nose and the chin piece is below your chin.
4. Pull both straps over your head. Move the lower
strap around your neck; pull the top strap onto your
head.
5. Using one hand, pinch the nose wire across the
bridge of your nose and along the sides.
6. Using both hands, press each side of the nose wire
strip to conform to your cheek bones on both sides.
7. With the respirator fitted to your face, place finger
and thumb on the ends of the Clear View Bar and
pinch towards the face to increase downward
visibility.
8. Seal Check:
a. Perform a seal check by covering the front of
the respirator with both hands, being careful not
to disturb the position of the respirator.
b. Exhale sharply. A positive pressure inside the
respirator means no leakage.
c. If leakage occurs, adjust the position and/or
tension of the straps and press down along the
nose piece as described in previous steps.
d. If you cannot achieve a proper seal, remove the
respirator and DO NOT enter the contaminated
area. See your supervisor.
-For a tighter fit, the bottom head strap can be pulled up
around your head.
-To remove respirator; grab the bottom corners with both
hands, pull away from your face and upwards so the
straps slip off your head.
WARNINGS:
1. Failure to follow all instructions and limitations on the
use of this product could reduce the effectiveness of
the respirator and result in sickness or death.
2. This respirator does not eliminate the risk of
contracting any disease or infection. Pathogens
could enter your body through your skin or eyes
unless you are wearing other PPE in addition to this
respirator.
3. Before occupational use of this respirator, a written
respiratory protection program must be
implemented, meeting all the local government
requirements. In the United States, employers must
comply with OSHA 29 CFR 1910.134; which
includes medical evaluation, training, and fit testing.
4. This product does not supply oxygen. Use only in
adequately ventilated areas containing sufficient
oxygen to support life.
5. Do not use when concentrations of contaminants are
immediately dangerous to health or life.
6. Evacuate area immediately if breathing becomes
difficult, you experience dizziness or other
respiratory distress occurs.
7. Mustaches, beards or other facial hair may reduce
the effectiveness of this respirator. Make sure that
nothing interferes with the seal when you are
wearing the respirator.
8. Do NOT alter or modify this respirator in any way.
9. Do NOT wash the respirator or get it wet. If
respirator gets wet, remove and discard.
10. If respirator becomes damaged, soiled or breathing
becomes difficult; dispose of the respirator and use a
new one.
11. Respirator may not be multi-use and must not be
worn in pathogenic, biological or chemical hazard
environments.
Contact Information:
Lighthouse Worldwide Solutions
1221 Disk Drive
Medford, OR 97501
Tel: +1 541-770-5905
www.golighthouse.com
Lighthouse Worldwide Solutions, Inc.
White City, OR, USA
1 (541) 770 5905
These respirators are approved only in the following configurations:
Protection1Hope 220 H210
Cautions
and
Limitations2
N95 X ABCJMNOP
N95 X ABCJMNOP
1. Protection
2. Cautions and Limitations
A
B
C
JFailure to properly use and maintain this product could result in injury or death.
M
N
O
P
Do not exceed maximum use concentrations established by regulatory standards.
All approved respirators shall be selected, fitted, used, and maintained in accordance with
MSHA, OSHA, and other applicable regulations.
Never substitute, modify, add, or omit parts. Use only exact replacement parts in the
configuration as specified by the manufacturer.
Refer to User Instructions, or maintenance manuals for information on use and
maintenance of these respirators.
NIOSH does not evaluate respirators for use as surgical masks.
Respirators
N95 – Particulate filter (95% filter efficiency level). Effective against
particulate aerosols free of oil; time use restrictions may apply.
Not for use in atmospheres containing less than 19.5 percent oxygen.
Not for use in atmospheres immediately dangerous to life or health.
TC-
84A-9268
84A-9376
414252905-1

Popular Respiratory Product manuals by other brands

John Bunn Neb-u-Lite LX2 user manual

John Bunn

John Bunn Neb-u-Lite LX2 user manual

Sundstrom SR562 How-to

Sundstrom

Sundstrom SR562 How-to

Vitalograph Asma-1 Healthcare Professional Manual

Vitalograph

Vitalograph Asma-1 Healthcare Professional Manual

NEMATEC FFP2 Instructions for use

NEMATEC

NEMATEC FFP2 Instructions for use

AccuMed NF100 user manual

AccuMed

AccuMed NF100 user manual

Gebol JC-1002 User information

Gebol

Gebol JC-1002 User information

CleanSpace CleanSpace2 User instructions

CleanSpace

CleanSpace CleanSpace2 User instructions

ResMed Flow Generator S8 Elite System Illustration manual

ResMed

ResMed Flow Generator S8 Elite System Illustration manual

Gentex PureFlo ESM+ Series Instructions for use

Gentex

Gentex PureFlo ESM+ Series Instructions for use

MABIS 40-369-000 Guide book

MABIS

MABIS 40-369-000 Guide book

Baynhams PeRSo 2.0 user manual

Baynhams

Baynhams PeRSo 2.0 user manual

ResMed Positive AirwAy Pressure Device S8 Auto 25 user guide

ResMed

ResMed Positive AirwAy Pressure Device S8 Auto 25 user guide

Datex-Ohmeda Engstrom Carestation Technical reference manual

Datex-Ohmeda

Datex-Ohmeda Engstrom Carestation Technical reference manual

Sleepnet Phantom User instructions

Sleepnet

Sleepnet Phantom User instructions

MSA PremAire Cadet 15M Maintenance procedures

MSA

MSA PremAire Cadet 15M Maintenance procedures

MPV Medical MicroDrop Family2 instruction manual

MPV Medical

MPV Medical MicroDrop Family2 instruction manual

Dräger X-plore 3300 quick start guide

Dräger

Dräger X-plore 3300 quick start guide

Bullard 88VX Series user manual

Bullard

Bullard 88VX Series user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.