manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Lightolier
  6. •
  7. UPS
  8. •
  9. Lightolier LOT Series User manual

Lightolier LOT Series User manual

Other Lightolier UPS manuals

Lightolier LUPS Series User manual

Lightolier

Lightolier LUPS Series User manual

Lightolier L1PH Series User manual

Lightolier

Lightolier L1PH Series User manual

Popular UPS manuals by other brands

AEG Protect 3.M 2.0 manual

AEG

AEG Protect 3.M 2.0 manual

Alpha Novus FXM 650 Installation and operation manual

Alpha

Alpha Novus FXM 650 Installation and operation manual

CyberPower RB12120X2A user manual

CyberPower

CyberPower RB12120X2A user manual

Pylontech Victron & Pylontech US5000 manual

Pylontech

Pylontech Victron & Pylontech US5000 manual

BEL LDX-U20 user manual

BEL

BEL LDX-U20 user manual

Mustek PowerMust 530(B) Plus Startup manual

Mustek

Mustek PowerMust 530(B) Plus Startup manual

Emerson Liebert NXL series Operation and maintenance manual

Emerson

Emerson Liebert NXL series Operation and maintenance manual

MAKELSAN BOXER SERIES user manual

MAKELSAN

MAKELSAN BOXER SERIES user manual

Block PC-0524-400-0 manual

Block

Block PC-0524-400-0 manual

CyberPower CP585LCD user manual

CyberPower

CyberPower CP585LCD user manual

Eaton 3S Advanced user's guide

Eaton

Eaton 3S Advanced user's guide

CyberPower Office Tower Series UPS 1000 user manual

CyberPower

CyberPower Office Tower Series UPS 1000 user manual

CyberPower BM100 quick start guide

CyberPower

CyberPower BM100 quick start guide

Best Power 610 quick start guide

Best Power

Best Power 610 quick start guide

Best Power Unity/I UT3K user manual

Best Power

Best Power Unity/I UT3K user manual

Mustek PowerMust 400 Offline user manual

Mustek

Mustek PowerMust 400 Offline user manual

Xantrex Trace 512 UR-UPS owner's manual

Xantrex

Xantrex Trace 512 UR-UPS owner's manual

Forza SL-1501UL user manual

Forza

Forza SL-1501UL user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

LOT Series
5.0-10.0 KVA SINGLE PHASE UPS
Page 1 of 2
Job Information Type:
Job Name:
Cat. No.:
Notes:
LOT
D
C
Overall Characteristics
Features: 87% throughput
efficiency with 85% emergency
efficiency. Operating
temperature range 32ºF
(0ºC) to 104ºF (40ºC). Fault
current rating of 42 kAIC.
Audible noise less than 50 dB
at 3 ft on “A” weighted scale.
Automatic low battery voltage
disconnect. Double conversion
with no interruption. Solid
state pulse width modulated
inverter. Internal, make before
break maintenance by-pass.
Standard UL 924 compliant,
90 minute battery back up.
UL 924 auxiliary equipment
10 and 20 minute back up
available. Microprocessor
control and diagnostic system.
LED array system status panel.
Fault annunciating audible
alarm. Current limiting start
sequence. Optional output
circuit breakers (OCB) and
circuit breakers with trip alarm
(OCBA). Optional normally
off load (NOL) energizes only
during power outage, normally
off load with time delay (TDT)
also available. Free standing
NEMA 1 enclosure. Lockable
control access panel. Seismic
anchoring compatible.
Application: The solid state
pulse width modulated (PWM)
inverter offers enhanced load
compatibility. It operates
incandescent, magnetic, and
electronic ballast fluorescent,
high power factor compact
fluorescent and high intensity
discharge (HID) luminaries.
Provides conditioned,
uninterruptible power for
other types of critical loads.
Consult factory for non-lighting
load applications.
Input: Input power factor
correcting to 0.99. Frequency
range 60 Hz, ±2.5 Hz. Input
harmonic current distortion
< 5%THD. UL1449, ANSI/IEEE
C62.41 surge suppression.
Output: Sine wave output.
Voltage regulation ±2%.
Frequency regulation is
synchronized to utility and free
running 60 Hz, ±0.5%. Output
voltage distortion maximum
3% THD with linear load. Load
power factor capability 0.7 lead
to 0.7 lag. Overload capability
125% for 10 seconds.
Code Compliance
UL 924 and UL 924 auxiliary
equipment listed.
Warranty
Lightolier will provide parts
and on-site labor for the first
12 months following start-
up of the product, and parts
only for an additional 12
months. If factory start-up is
not executed within 120 days
of shipment, Lightolier will
provide a parts warranty for
12 months from the date of
shipment. Consult factory for
extended warranty and service
option.
B
5.0 kVA
36"
24"
80"
N/A
6.0-10.0 kVA
36"
24"
80"
29"
Width (A)
Depth (B)
Height (C)
Width (D)
A
Electronics
Cabinet
Battery
Cabinet
LOT Series
5.0-10.0 KVA SINGLE PHASE UPS
Page 2 of 2
Philips Lightolier
e: [email protected]
t: (508) 679-8131
w: www.lightolier.com
LOT Series - 5.0-10.0 September 12, 2011
Specifications are subject to change without notice.
© Koninklijke Philips Electronics N.V., 2011.All rights reserved.
Job Information Type:
Ordering Information
On Bus w/ Optional
Distribution
Optional Off/
Timed Off Bus w/
Distribution
DC
Fuse
Battery
Pack
Input
Circuit
Breaker
Inverter
Fuse
AC
Input
SS
System Rating (kW/kVA)
Input Volt. (V):Input Curr. (A)
Output Volt:Output Current*
OCB Pole Spaces Available
Without Trip Alarm
With Trip Alarm
Heat Rejection (btu/hr)
Weight (lbs) Electronics
Empty Batt Cab
90 Min Battery
20 Min Battery
10 Min Battery
5.0
120 : 54.6
120/240 : 27.3
277 : 23.7
120/208 : 31.5
120 : 41.6
120/240 : 41.6/20.8
277 : 18
120/208 : 41.6/24
120/277 : 41.6/18
20
10
2387
840
N/A
850
350
230
System Input/Output Ratings
SS
Bypass
Output
Hardwired
(Standard)
P
F
C
Series
LOT = Single
Phase UPS
System for
Emergency
Lighting
Applications
A= 120 V*
G= 120/240 V
J= 277 V
L= 120/208 V
Input Voltage
Q
ty Circuit
Breakers
00X = Hardwire
01X = 1 OCB
02X = 2 OCB
03X = 3 OCB
04X = 4 OCB
.
.
20X = 20 OCB
01A = 1 OCBA
02A = 2 OCBA
03A = 3 OCBA
.
.
10A = 10 OCBA
(max. pole spaces 20)
LOT
Unit Size
5.0 = 5.0 kVA
6.0 = 6.0 kVA
7.5 = 7.5 kVA
8.5 = 8.5 kVA
10.0 = 10.0 kVA
Battery Time
S= 90 Min
X= 10 Min**
Y= 20 Min
# Nol Circuit
Breakers
A= 1
B= 2
C= 3
D= 4
E= 5
F= 6
G= 7
H= 8
I= 9
J= 10
K= 11
L= 12
M= 13
N= 14
O= 15
P= 16
Q= 17
R= 18
S= 19
T= 20
Z= No Nol
Hardwired
System One-Line Diagram
A= 120 V*
G= 120/240 V
J= 277 V
L= 120/208 V
Y= 120/277 V
Output Voltage Nol
0= None
1= Yes
T= Nol w/
TDT
Breakers
O
n
2nd Voltage
00 = 2nd
Voltage
Hardwire
or No 2nd
Voltage
01
02
03
.
.
19
Nol Voltage
1= First
2= Second
3= Both
0= No Nol
Q
ty Nol 2nd
Voltage
A= 1
B= 2
C= 3
D= 4
E= 5
F= 6
G= 7
H= 8
I= 9
J= 10
K= 11
L= 12
M= 13
N= 14
O= 15
P= 16
Q= 17
R= 18
S= 19
Z= No Nol
6.0
120 : N/A
120/240 : 37.4
277 : 32.4
120/208 : 43.1
120 : N/A
120/240 : 50/25
277 : 21.7
120/208 : 50/28.8
120/277 : 50/21.7
20
10
2864
950
350
1325
350
N/A
7.5
120 : N/A
120/240 : 42.8
277 : 36.9
120/208 : 49.2
120 : N/A
120/240 : 62.5/31.2
277 : 27.0
120/208 : 62.5/36
120/277 : 62.5/27
20
10
3581
950
350
1500
550
350
8.5
120 : N/A
120/240 : 50.1
277 : 43.3
120/208 : 57.7
120 : N/A
120/240 : 70.8/35.4
277 : 30.7
120/208 : 70.8/40.9
120/277 : 70.8/30.7
20
10
4058
1000
400
1500
480
N/A
10.0
120 : N/A
120/240 : 54.6
277 : 47.3
120/208 : 63.0
120 : N/A
120/240 : 83.3/41.6
277 : 36.1
120/208 : 83.3/48
120/277 : 83.3/36.1
20
10
4774
950
350
1680
1000
900
Rectifier
Inverter
Output
Circuit
Breaker
* Multi-voltage total loads not to exceed system rating.
* Only available on 5.0 kVA.