Lindgren-Pitman LP-TIMER-3 User manual

8 9 11 12 13
LP-TIMER-3
LINDGREN-PITMAN, INC.
qInstallation: First locate your power source. The timer beeper should be powered using
only clean12-24 volt DC power. Power should always come from a breaker that does not
exceed its maximum ratedamperage. The timer beeper draws approximately 1 amp at full load.
1. Hook Counter
3. Seconds
Between Hooks
9. Brightness
14. Timer Start Button 15. Timer Stop
2. Buoy Counter
4. Seconds
Between Buoys
7. Adjustment Keys
for Hook Timer 10. Adjustment
Keys for Buoy
Timer
Button
16
16
16
16
5. Hook Count Reset 6. Buoy Count Reset
Hook and Buoy Timer/Counter
Installation and Instruction Sheet
qMounting: The enclosure is rated for a marine environment but care should be taken to place it
where it is not exposed to extreme weather or direct sunlight. It comes prewired so there should be no
need to openthe enclosure. Use the aluminum bracket attached to the back of the timer to preposition the
hole locations. Ifnecessary the bracket can be removed using a philips screwdriver. Once the holes are
located replace thebracket and mount the unit.
Only under extremely tight conditions should mounting without the bracket be attempted and extra
special attention will be required or the unit will not operate.Remove the face of the unit by removing
the four philips screws that hold the face to the body (16). Carefully unplug the 8-pin terminal that
connects the membrane touch panel to the circuit board (the blue connector). If you are not careful the
ribbon cable will tear and the unit will not function. Do so by wiggling the connector from side to side while
pushing it towards the display.Please note the wire that attaches the touch panel to the circuit board is
short and can be easily damaged, do not pry or pull on it. You can also use a small screwdriver to push the
blue connector towards the displays until it unplugs from its mount on the circuit board. With the face
removed the base can be mounted using the holes located underneath the four philips screws that hold
the cover on the box (16). Use water-resistant marine grade 16 gauge tinned copper two conductor wire
or similar to connect the timer beeper to the power source and speaker. Once the mounting is complete
reconnect the 8-pin terminal strip to the unit and reinstall the four cover screws.

Lindgren-Pitman, Inc. 2615 NE 5th Avenue, Pompano Beach, FL 33064
phone (954) 943-4243 q fax (954) 943-4243
email: [email protected]
http://www.lindgren-pitman.com
Part# LP-TIMER-3
Note: Be patient when pushing the buttons on the membrane switch. Several seconds may be
needed between each push of the button before the unit registers the change. Use only soap and water
to clean both the timer beeper and its cover. Cleaning agents or dirty rags will scratch its surface making
the display hard to read and could eventually ruin the switch pad.
q CONFIG MODE:
Holding down the “STOP” button for 3 seconds will toggle the beeper into “CONFIG MODE”
Exit out of config mode by holding “STOP” again for 3 seconds.
In the config mode there are 3 different settings that can be adjusted.
Setting 0 – Brightness Level 0-15 Default:8
Setting 1 – Hook buzzer tone 0-9 Default:9
Setting 2 – Buoy buzzer tone 0-9 Default:0
qSpeaker Installation:Connect the white/black wire from the speaker to the positive (red wire) coming
out of the box on the side marked speaker. Next connect the white speaker wire to the negative (black
wire)coming out of the box marked speaker. Run the appropriate type of water resistant copper tinned
16/2 wire so the speaker is as close to the baiting station as possible. Solder and seal all connections.
To ensure that everything is mounted and working, turn the unit on waiting for the displays to revert to zero.
Set the hook timer to 5 seconds by pushing on the up arrow on key (8) five times. The seconds between
hook timer will now display 5. Next set the buoy timer to 8seconds by pushing on the up arrow on key
(13) eight times. Pushthe start button (14) and the timer will begin a count down for both the hook and
buoy. When each of therespective count down timers reaches zero either the hook (a short high-pitched
beep) or a buoy (a longer lower pitched beep) will sound. At the same time as the beep, the counter
display will increase by one unit for whichever timer reached zero. This function allows the operator to keep
track of the number of hooks and buoys as the main line is being set.
qConnecting Power:Once the unit has been mounted route the power wire to its source voltage,
making sure power is turned off. Connect the black wire (-) to your ground source and the red wire (+)
to the positive. Should the supplied power cord be too short, a longer cord can be fabricated making sure
to use the same water resistant copper tinned 16/2 wire. Once the unit has been properly wired, turn the
breaker on and display will flash all display segments for approximately 2 seconds. It will then revert to a
single 0 digit in each of the display windows until the timers are set. Should the unit fail to power up
recheck all connections, double checking polarity. If it continues to be inoperable, carefully remove the
display panel and circuit board from the base enclosure. As a safety measure a 1-amp 250-volt
replaceable fuse is located on the backside of the circuitboard, check for continuity to ensure the unit is
receiving power (do not exceed 26 volts).
qUsing the Timer Beeper: Now that the unit is installed and is fully functional it can be set for
actual use. Set both the hook (7) and buoy (10) timer times by pushing the adjustment keys up or
down.The hook timercan be set for up to 99 seconds while the buoy timer can be set for up to 999
seconds. Once set push the start (14) key and the timers begin counting down. Changes to the
time interval between hooks and buoys can be made “while the unit is operating” but it will not be
reflected on the display until after the countdown timer reaches zero. At anytime during operation the
hook (1) and buoy(2) counters can be reset to zero by pushing the reset buttons (5) and (6)
respectively. Under normal circumstances the reset buttons are only used if the unit is not powered
down before starting a new set. When used in this manner the hook and buoy times will not change
unless the user either pushed the adjustment keys or powers down the timer beeper. It is
recommended that the unit be switched off through the breaker panel when the timer beeper is not
needed.
F:\WORK\TIMER-3\Timer_3_Instruction_Sheet_Ver_1.1.pdf
Table of contents
Popular Cash Counter manuals by other brands

Cassida
Cassida C-880 user manual

DEUTA Controls
DEUTA Controls enocean EnoSense AL-436-00-902 manual

Nautilus Hyosung
Nautilus Hyosung MS400A Hardware installation manual

Eaton
Eaton xComfort CIZE-02/01 Assembly instructions

Simex
Simex SLM-44 user manual

Agilent Technologies
Agilent Technologies 53131A Assembly Level Service Guide