LINDR VK 15 User manual

LINDR MINI
COMPRESSOR
Number 013-2020 REV00 Valid 2020-06-01
INSTRUCTION MANUAL
ENGLISH
VK 15, vk 30 MINI COMPRESSOR

2
IMPORTANT
This manual contains instructions for installation, use and operation of the ap-
pliance. This manual is an integral part of the device. It must be stored in the
vicinity of the device for the entirety of its service life and must be made avail-
able to the user any time the device is installed, moved, used or maintained.
Read this manual carefully before installing and using the device. It contains
important information necessary to ensure that all operations are done prop-
erly and safely.
WARNING:
Not following instructions may cause injury or
damage the device.
SYMBOLS AND MARKINGS USED IN THE MANUAL:
DANGER:
Risk of injury by electrical current.
NOTE:
This symbol indicates information and recom-
mendations for the user.
LINDR.CZ s.r.o.
Sadová 132
503 15 Nechanice, Czech Republic
mobile: + 420 775 715 494
tel.:+420 495 447 239
e-mail: info@lindr.cz
web: www.lindr.cz,www.lindr.eu
is manual is a translation of the original Czech manual.

MINI COMPRESSOR
3
Contents:
1. Introduction
2. Device description
3. Machine plate
4. General instructions, measures and safety instructions
5. Installation and placement
6. Electrical connection
7. Testing
8. Warranty
9. Device description
10. Connection and pressurisation
11. How to work with speed ttings
12. AIR connection
13. Air pressure adjustment
14. Putting into operation
15. Table of malfunctions
16. Spare parts
17. Inspection before every use
18. Periodic checks
19. Environmental protection
20. Technical specications
..................................
..................................
..................................
..................................
..................................
..................................
..................................
..................................
..................................
..................................
..................................
..................................
..................................
..................................
..................................
..................................
..................................
..................................
..................................
..................................
4
4
4
4
5
5
5
5
6
7
8
8
8
9
9
10
10
10
10
11

4
1. INTRODUCTION:
Thank you for purchasing this LINDR product.
2. DEVICE DESCRIPTION
The VK LINDR mini-compressor is primarily de-
signed as an accessory for ow-through cool-
ers and beverage keg pressurisation.
VK models allow smooth regulation of pres-
sure in 1.0-3.4 bar range (VK LINDR 15) and 1.0-
4.2 bar range (VK LINDR 30). The set pressure is
displayed in bars on the pressure gauge. The
compressor can be turned o separately with
a switch. The air outlet from the compressor
terminates with a 5/16" (8 mm) speed tting.
The air compressor is zero-maintenance, tted
with a molecule lter for the drawn-in air.
This manual is designed for the following
models:
VK LINDR 15/ for dispensing rate: 40 l/h
VK LINDR 30/ for dispensing rate: 120 l/h
3. MACHINE PLATE
4. GENERAL INSTRUCTIONS, MEASURES
AND SAFETY INSTRUCTIONS
Follow basic safety instructions stated by the
manufacturer when using the device. Any oth-
er use is considered impermissible and there-
fore dangerous. The supplier is not liable for
damage caused by incorrect use.
DO NOT USE THE DEVICE FOR PURPOSES
OTHER THAN THOSE STATED BY THE MANU-
FACTURER!
General safety principles. Observe the fol-
lowing safety instructions.
The supplier is not liable for damage caused
by activities carried out on this device without
observing the following instructions!
WARNING: Children aged 15 or more and
persons with reduced physical, sensory or
mental capabilities or insucient experience
and knowledge may only use the device when
supervised or instructed in safe use of the ap-
pliance and familiarised with potential dan-
gers.
WARNING: Children must not be allowed
to play with the appliance. Store all packaging
material out of reach of children (comes with a
plastic bag – suocation hazard).
WARNING: Cleaning and maintenance of
the appliance on the part of the user must not
be done by unsupervised children.
WARNING: Before connecting to main elec-
trical supply, check that the voltage and fre-
quency in the mains corresponds to the data
stated on the device.
WARNING: Always make sure that the sock-
et you intend to plug the device into meets
the specications on the machine plate (volt-
age, frequency, input power).
WARNING: Never touch electrical compo-
nents with wet or damp hands.
WARNING: Always make sure the power
socket you intend to plug the device into is ac-
cessible, so that the appliance can be immedi-
ately unplugged in case of emergency.
WARNING: When unplugging the device
from the socket, grab the plug and pull it out.
Do not under any circumstances pull at the ca-
ble; risk of damage.
WARNING: To turn the device o complete-
ly, unplug the appliance from the power sock-
et.
WARNING: In the event the electrical wiring
of the product becomes damaged, summon a
trained service technician. Do not under any
circumstances repair the device yourself.

MINI COMPRESSOR
5
WARNING: Emergency maintenance and
repair of the device must be done by trained,
authorised technicians familiar with cooling
and electrical systems. Follow basic regula-
tions and safety measures regarding service
and repair!
5. INSTALLATION AND PLACEMENT
Place the compressor onto a stable, level sur-
face (maximum permitted inclination: 2 de-
grees). The appliance requires unobstructed
air circulation.
• Ensure sucient free space for air circulation
and heat dissipation.
• Ensure sucient supply of fresh air.
• The device must not be placed in an enclosed
space.
• The device must not be placed in the vicinity
of heat sources or exposed to direct sunlight.
Minimum distance of vents from an obstacle
that would limit air circulation must be 30 cm.
Minimum distance for sections with no air
vents is 7 cm. Ideally, use the device in a cool
and well ventilated room. The device is de-
signed for use at ambient temperature of at
least 16 °C and at most 32°C.
WARNING: The device is designed for use
in a normal environment, always under a roof,
protected from rain or sunlight. Climate class
N.
DANGER: Protect the device and electrical
connection from rain and spraying water!
6. ELECTRICAL CONNECTION
Connect the device to a power socket in ac-
cordance with specications on the machine
plate of the device. Electrical wiring is subject
to local regulations. If the power leads (ca-
bles) are damaged, they must be replaced by
the manufacturer, their service technician or
a similarly qualied person to prevent risk of
hazardous situations.
DANGER: Do not use or turn on the device
if the power lead (cable) is damaged!
7. TESTING
The product is delivered ready for immediate
use.
8. WARRANTY
The device comes with a warranty in accord-
ance with general legal regulations of the
Czech Republic or in accordance with the
trade agreement. During the validity period
of the warranty, we will remove any defects on
the product free of charge, provided these de-
fects were not caused by excess wear, improp-
er handling, incorrect storage or by using the
product in a way that is counter to the instruc-
tion manual or the product's design as dened
by the manufacturer. Materials replaced dur-
ing the validity period of the warranty are our
property. The legitimacy of the warranty claim
is always decided by an authorised service
centre. Warranty provided by a retailer outside
of the territory of the Czech Republic is gov-
erned by the agreement between the retail-
er and the buyer in their mutual relationship;
this agreement is not directly linked to the
manufacturer. The agreement does not give
the buyer the right to submit warranty claims
to the manufacturer. Transport expenses or
other costs are not covered by the warranty.
NOTE: In order for the device to work
correctly and at maximum output, it is im-
portant to not cover up any of the device's
vents and ensure sucient air circulation.
ATTENTION:
Electrical devices and appliances must be
checked/inspected at a time stipulated by
valid legislation of the country the device
is operated in. Inspection of wiring may
only be done by a person with valid au-
thorisation for this activity. Service work,
provision of spare parts and inspection is
done by the manufacturer or an author-
ised service centre.

6
9. DEVICE DESCRIPTION
1. Air outlet 4. Pressure gauge
2. Switch 5. Power cable
3. Adjusting screw
NOTE: The VK LINDR mini-compressor is primarily designed as an accessory for
ow-through coolers and beverage keg pressurisation.

MINI COMPRESSOR
7
10. CONNECTION AND PRESSURISATION
gure 7 A
gure 7 b
10.1 Connection and Pressurisation by VK LINDR 15/30 Mini-Compressor (One-Tap Device)
1. Beverage inlet
2. Keg coupler (S-system, A-system, M-system)
3. F 5/8 x 9.5 mm speed tting
4. F 5/8 x 8 mm speed tting
5. VK LINDR mini compressor
6. Beverage
10.2 Connection and Pressurisation by VK LINDR 30 Mini Compressor (Two-Tap Device)
1. Beverage inlet
2. Keg coupler (S-system, A-system, M-system)
3. F 5/8 x 9.5 mm speed tting
4. F 5/8 x 8 mm speed tting
5. Y 8 x 8 x 8 mm speed tting
6. VK LINDR mini compressor
7. Beverage

8
11. HOW TO WORK WITH SPEED FITTINGS
11.1 Speed Fitting Installation
Grasp the speed tting and insert the hose all
the way inside the speed tting body (ca. 20
mm). The end of the hose must be straight so
that it plugs fully into the coupling. If the hose
will not go in, moisten the end of the hose.
gure 8 A
11.2 Speed Fitting Removal
Hold the grey ring tight against the body of
the speed tting and pull out the hose.
gure 8 B
WARNING: If you do not hold the grey ring but pull at the hose, the speed tting will cut
even deeper into the hose.
WARNING: Hoses must not be pressurised during removal.
12. AIR CONNECTION
Connect the VK LINDR mini compressor to a keg coupler. Plug
a 5/16” air hose into the speed tting on the front of the com-
pressor - Air outlet (1.).
13. AIR PRESSURE ADJUSTMENT
Pressure is adjusted mechanically using the adjustment screw
(3.) located on the front of the compressor. Set the pressure to
the desired value according to the pressure gauge.
gure 8 C
gure 8 D

MINI COMPRESSOR
9
NOTE: If the defect persists even after the above steps are taken, contact a service centre.
15. TABLE OF MALFUNCTIONS
Malfunction Cause Removal
compressor does not run switch is in the o position check the switch (2.)
regulation set to minimum adjust pressure setting using the adjusting screw (3.)
power cable is not plugged
in the socket properly unplug the cable from the socket and replug it
issue with the socket try connecting a dierent device to the socket
compressor runs but
does not achieve the set
pressure
leaky joints, air hose con-
nected incorrectly unplug and replug the air hose in accordance with
point 11. (How to Work with Speed Fittings)
Do not forget to specify the following:
• type of defect
• product type
• production year
• product's serial number (found on the machine plate)
14. PUTTING INTO OPERATION
1. Interconnect the air supply and beverage supply.
2. Connect the mini compressor to the power mains.
3. Check that all the joints and connections are suciently tight.
4. Turn on the air compressor using the switch and pressurise to the desired pressure.
WARNING: Use the device only as an accessory to ow-through coolers. Follow the safety
instructions and do not overload the device.
LINDR 15 for pressurising a single beverage line with maximum ow rate of 40 l/h.
LINDR 30 for pressurising two beverage lines with maximum ow rate of 120 l/h.

10
16. SPARE PARTS
When ordering spare parts, always provide the following:
• product type
• production year
• product's serial number
• full name of the spare part and its number
Ordering Components
ALWAYS USE ORIGINAL COMPONENTS. The manufacturer or supplier bear no responsibility
for non-original components or components not recommended by the manufacturer.
17. INSPECTION BEFORE EVERY USE
1. Visual check.
2. Lead-in cable check.
WARNING: Do not use the device if defects or malfunctions are found.
18. PERIODIC CHECKS
1x a week: check that the lead-in cable is
undamaged and that the plug is rmly in the
socket.
1x a week: check that the device is not ex-
posed to radiant heat.
1x a week: check that air circulation is not
obstructed.
1x a year: have an engineering inspector
check the electrical safety of the device.
19. ENVIRONMENTAL PROTECTION
Waste Sorting
This product must not be disposed of in communal waste. Electrical waste in the Czech
Republic is disposed of within the Rema System (www.remasystem.cz).
In countries other than the Czech Republic, waste sorting is subject to local regulations.
Sorting waste allows recycling and reusing used products and packaging materials. Reuse
of recycled material helps protect the environment from pollution and reduces resource
consumption. Local regulations may regulate the method of disposing of household ap-
pliances at local collection points or at the point of sale.

MINI COMPRESSOR
11
20. TECHNICAL SPECIFICATIONS
Name LINDR 15 LINDR 30
Maximum output (l/hour) 40 120
Voltage (V/ Hz~1) 220 – 240 V 50Hz~1 220 – 240 V 50Hz~1
Input power (W) (W) 92 115
Current (A) (A) 0.4 0.5
Frame dimensions (WxDxH mm) 150x240x250 150x240x250
Net weight (kg) 4.5 4.5

This manual suits for next models
1
Table of contents
Popular Compressor manuals by other brands

Danfoss
Danfoss Maneurop NTZ048 Selection and Application Guidelines

Boge
Boge S Series operating instructions

Gardner Denver
Gardner Denver DRUM D9000 Installation operating & maintenance manual

Comprag
Comprag ARD1510-500 manual

Porter-Cable
Porter-Cable CFBN125N instruction manual

EINHELL
EINHELL TC-AC 190 OF Set Original operating instructions