Lite-Purter ECP-105T User manual

ECP-105T [EUM-C]
User Manual
ECP-105T
Touch Panel

ECP-105T [EUM-C]
INDEX
1. INTRODUCTION.......................................................................................................................................1
1-1 FEATURE ......................................................................................................................................................... 1
1-2 SPECIFICATION.................................................................................................................................................. 1
1-3 FUNCTION INTRODUCTION.................................................................................................................................. 1
1-4 OPEN THE UPPER COVER.................................................................................................................................... 3
1-5 SYSTEM DIAGRAM............................................................................................................................................. 3
2. OPERATION..............................................................................................................................................4
2-1 ZONE SETTING.................................................................................................................................................. 4
2-1-1 EDX SYSTEM ................................................................................................................................................ 4
2-1-2 PURPOSE OF ZONE SETTING............................................................................................................................. 4
2-1-3 ZONE SETTING MODE OF DIP .......................................................................................................................... 5
2-1-4 CANCEL ZONE SETTING MODE ......................................................................................................................... 5
2-2 SCENE RECALL .................................................................................................................................................. 5
2-3 KEY LOCK/UNLOCK FUNCTION............................................................................................................................. 6
2-4 IR REMOTE CONTROL ........................................................................................................................................ 6
2-5 BRIGHTNESS INDUCTION..................................................................................................................................... 6
2-6 DRY CONTACT INPUTS........................................................................................................................................ 7
APPENDIX: BINARY CODE PRINCIPAL.................................................................................................10
LIMITED WARRANTY................................................................................................................................11

ECP-105T [EUM-C]
1
1. Introduction
1-1 Feature
1. In multi-zone mode, one ECP-105T can control 1-8 zones at the same time.
2. Can recall 4 scenes.
3. 256 level dimming solutions enable more complicated lighting change.
4. Lock/unlock setting.
5. IR remote control
6. Two dry contacts input.
1-2 Specification
1. Protocol: EDX
2. Signal Connector: 4 pin green terminal
3. Dimension: 86(W)* 86(H)* 21(D)mm
4. Weight: 130g
1-3 Function Introduction
Front Side:

ECP-105T [EUM-C]
2
Rear Side:
1. Scene 1- 4
2. OFF button
3. Panel light window
4. IR window
5. DIP switch

ECP-105T [EUM-C]
3
1-4 Open the Upper Cover
:with screwdriver
1-5 System Diagram

ECP-105T [EUM-C]
4
2. Operation
2-1 Zone Setting
2-1-1 EDX System
EDX is designed for architecture and environmental lighting. EDX can save scene and each EDX/ECP
panel can set Zone. ECP panel can control EDX (same zone number).
For instance: ECP panel (Zone=1) can control EDX (Zone=1)
One ECP panel can control one EDX, shown as below:
2-1-2 Purpose of Zone Setting
One ECP-105T can control 1-8 zones at the same time in EDX, before using the
panels, be confirm the zone controlled by each panel.
ECP-105T has two control modes: single-zone mode and multi-zone mode.
DIP.9 (ON): multi-zone mode;
DIP.9 (OFF): single-zone mode.
EDX
(Zone 1)
Signal
ECP Panel
(Zone 1)

ECP-105T [EUM-C]
5
2-1-3 Zone Setting Mode of DIP
The Function of DIP is as above.
Single-zone mode (DIP.9/OFF): DIP.1---DIP.8 set zone with binary, can set 1-255
zones.
Multi-zone mode (DIP.9/ON): DIP.1---DIP.8 means 1st---8th zone.
2-1-4 Cancel Zone Setting Mode
The user can cancel the zone setting value if each of DIP is OFF.
2-2 Scene Recall
Press【1……4】to recall the scene.
For instance: press【1】to recall Scene 1, and【1】shows red back light.
In FADE state (by fault): press 【1……4】to show scene in FADE(in/out); Quick double click
【1……4】to recall scene.
Zone setting Code
Single / multi-zone Code
IR ON/OFF Code

ECP-105T [EUM-C]
6
2-3 Key Lock/Unlock Function
Hold any scene button for 5 seconds, then the buzzer rings twice (means key
lock), LED blinks;
In the case of being locked, hold any scene button for 5 seconds, then the buzzer
rings once (means key unlock), LED stops blinking.
2-4 IR Remote Control
ECP-105T can receive IR-0501 to recall scene
IR remote control functions setting (turn on/turn off):
DIP10/ON: turn on IR remote control function:
DIP10/OFF: turn off IR remote control function.
2-5 Brightness Induction
ECP-105T auto-induce environment brightness and adjust brightness of the panel
according to the brightness of surrounding environment.
The stronger the bright is, the brighter the panel instructor is, and vice versa.
DIP10/ON=turn on IR remote control function

ECP-105T [EUM-C]
7
2-6 Dry Contact Inputs
NOTE: if the panel is in SC (OFF), the dry contact is acted; if the panel recalls any
SC (not OFF), the dry contact is not acted;
In EDX:
The SC 5 will be recalled by actuating input 1; SC OFF will be recalled by
disconnecting input 1 for 30s;
The SC 6 will be recalled by actuating input 2; SC OFF will be recalled by
disconnecting input 2 for 30s.
In NEX:
1. Set ECP-105T single zone, the zone is 01
STEP1:Send command of SERVICE18 by actuating input 1; DP-E700
executes the command of SERVICE18:
80 01 55 01 00 12 00 00 05
STEP2:Send command of SERVICE19 by disconnecting input 1; DP-E700
executes the command of SERVICE19:
80 01 55 01 00 13 00 00 05
STEP3:Send command of SERVICE20 by actuating input 2; DP-E700
executes the command of SERVICE20:
80 01 55 01 00 14 00 00 05
STEP4:Send command of SERVICE21 by disconnecting input 2; DP-E700
executes the command of SERVICE21:

ECP-105T [EUM-C]
8
80 01 55 01 00 15 00 00 05
2. Set ECP-105T single zone, the zone is 02
STEP1:Send command of SERVICE22 by actuating input 1; DP-E700
executes the command of SERVICE22:
80 02 55 01 00 16 00 00 05
STEP2:Send command of SERVICE23 by disconnecting input 1; DP-E700
executes the command of SERVICE23:
80 02 55 01 00 17 00 00 05
STEP3:Send command of SERVICE24 by actuating input 2; DP-E700
executes the command of SERVICE24:
80 02 55 01 00 18 00 00 05
STEP4:Send command of SERVICE25 by disconnecting input 2; DP-E700
executes the command of SERVICE25:
80 02 55 01 00 19 00 00 05
3. Set ECP-105T single zone, the zone is 03
STEP1:Send command of SERVICE26 by actuating input 1; DP-E700
executes the command of SERVICE26:
80 03 55 01 00 1A 00 00 05
STEP2:Send command of SERVICE27 by disconnecting input 1; DP-E700
executes the command of SERVICE27:
80 03 55 01 00 1B 00 00 05
STEP3:Send command of SERVICE28 by actuating input 2; DP-E700
executes the command of SERVICE28:
80 03 55 01 00 1C 00 00 05
STEP4:Send command of SERVICE29 by disconnecting input 2; DP-E700
executes the command of SERVICE29:
80 3 55 01 00 1D 00 00 05
4. Set ECP-105T single zone, the zone is 04
STEP1:Send command of SERVICE30 by actuating input 1; DP-E700
executes the command of SERVICE30:
80 04 55 01 00 1E 00 00 05
STEP2:Send command of SERVICE31 by disconnecting input 1; DP-E700
executes the command of SERVICE31:
80 04 55 01 00 1F 00 00 05
STEP3:Send command of SERVICE32 by actuating input 2; DP-E700
executes the command of SERVICE32:
80 04 55 01 00 20 00 00 05
STEP4:Send command of SERVICE33 by disconnecting input 2; DP-E700

ECP-105T [EUM-C]
9
executes the command of SERVICE33:
80 04 55 01 00 21 00 00 05
5. Set ECP-105T single zone as 5-128 or multi-zone as 1-8:
Set zone of ECP-105T is 8(single/multi-zone)
STEP1:Send command of recalling SC5 by actuating input 1; DP-E700
executes SC5 of Zone 8;
STEP2:Send command of recalling SC OFF by disconnecting input 1;
DP-E700 executes SCOFF of Zone 8;
STEP3:Send command of recalling SC6 by actuating input 2; DP-E700
executes SC6 of Zone 8;
STEP4:Send command of recalling SC OFF by disconnecting input 2;
DP-E700 executes SCOFF of Zone 8;

ECP-105T [EUM-C]
10
Appendix: Binary Code Principal
ZONE
8 bit DIP
ZONE
8 bit DIP
ZONE
8 bit DIP
12345678
12345678
12345678
1
10000000
2
01000000
3
11000000
4
00100000
5
10100000
6
01100000
7
11100000
8
00010000
9
10010000
10
01010000
11
11010000
12
00110000
13
10110000
14
01110000
15
11110000
16
00001000
17
10001000
18
01001000
19
11001000
20
00101000
21
10101000
22
01101000
23
11010000
24
00011000
25
10011000
26
01011000
27
11011000
28
00111000
29
10111000
30
01111000
31
11111000
32
00000100
33
10000100
34
01000100
35
11000100
36
00100100
37
10100100
38
01100100
39
11100100
40
00010100
41
10010100
42
010101000
43
11010100
44
00110100
45
10110100
46
01110100
47
11110100
48
00001100
49
10001100
50
01001100
51
11001100
52
00101100
53
10101100
54
01101100
55
11101100
56
00011100
57
10011100
58
01011100
59
10011100
60
00111100
61
10111100
…
…
255
11111111
※0 = DIP/OFF; 1= DIP/ON.

ECP-105T [EUM-C]
11
Limited Warranty
1. Lite-Puter is only responsible for the product itself.
2. Lite-Puter guarantees to keep Lite-Puter’s from manufacturing defects within a year since the
distributing date.
3. Lite-Puter does not offer on-site service. If the defects appears in Lite-Puter’s product, please deliver
the product to local distributors or to Taipei headquarters.
4. The warranty does not cover:
a. Any fault caused by false usage, imprudence (collision, inadequate installation or adjustment,
insufficient ventilation, or improper repairs)
b. Force majeure factors (flooding, earthquake, thunder, volcanic eruption, tsunami or other factors
beyond Lite-Puter control).
c. The cost of installing, reinstalling, adjusting, repairing, or reprogramming the product.
d. Other products or devices which are offered by Lite-Puter or not by Lite-Puter.
5. Lite-Puter does not warrant the product will operate without interruption or being free of error.
World Headquarters:
Lite-Puter Enterprise Co., Ltd.
Address: 11F, No. 189, Gangqian Rd., Neihu Dist., Taipei City 11494, Taiwan.
Tel: +886-2-27998099
Fax: +886-2-27993828
Website: www.liteputer.com.tw
E-mail: sales@liteputer.com.tw
Shanghai Factory:
Lite-Puter Technology(Shanghai)Co.,Ltd.
Address: Building B5, No. 298, Lane 3509, Hongmei S. Road, Shanghai, China
Zip Code:201108
Tel: +86-21-54408210
Fax: +86-21-64978079
Website: www.liteputer.com.tw
E-mail: sales_china@liteputer.com.tw
Table of contents