Lite-Puter EDX-B02D User manual

EDX-B02D [EUM-B]
0
User Manual
EDX-B02D
2-Channel Curtain Controller

EDX-B02D [EUM-B]
1
INDEX
1. Introduction.................................................................................................................................................................. 2
1-1 Feature.............................................................................................................................................................. 2
1-2 Specification..................................................................................................................................................... 2
1-3 Dimension......................................................................................................................................................... 3
1-4 Panel Introduction........................................................................................................................................... 3
1-5 Wiring Diagram................................................................................................................................................ 4
2. Operation..................................................................................................................................................................... 5
2-1 Initialization....................................................................................................................................................... 5
2-2 DMX Address Setting..................................................................................................................................... 5
2-3 Motor Control................................................................................................................................................... 6
2-4 Accept/Refuse DMX Signal........................................................................................................................... 6
2-5 ID No. Setting................................................................................................................................................... 7
2-6 Zone Setting..................................................................................................................................................... 7
2-6-1 Single/Multi Zone Setting.................................................................................................................... 7
2-6-2 Single Zone Setting.............................................................................................................................. 7
2-6-3 Multi Zone Setting................................................................................................................................. 8
2-7 Scene Setting................................................................................................................................................... 8
2-8 Scene Save and Recall................................................................................................................................. 9
2-9 Scene Duration Setting.................................................................................................................................. 9
2-10 Motor Rotate Setting..................................................................................................................................10
2-11 Check Software Version............................................................................................................................10
LimitedWarranty...........................................................................................................................................................11

EDX-B02D [EUM-B]
2
1. Introduction
1-1 Feature
Standard DMX control. When the DMX value higher than 75%, curtain motor start
to rotate clockwise; when the DMX value lower than 25%, curtain motor start to
rotate counterclockwise; When the DMX value is in the range of 25%-75%, the
curtain motor stop rotating.
2 dry contacts output control the curtain motor rotate clockwise and
counterclockwise.
Accept ECP control panel.
Can save 6 scenes.
1-2 Specification
Power supply: AC 100-240V 50Hz-60Hz
Protocol: DMX-512/RS-485
Signal connector: 6P6C PHONE JACK(RJ11) *2, 4Pin green terminal
Installation: track-mounted
Dimension: 198 (W) x 90 (H) x 62 (D) mm
Weight: 650g

EDX-B02D [EUM-B]
3
1-3 Dimension
1-4 Panel Introduction
11
1
2
3
4
5
7
10
0
9
6
8

EDX-B02D [EUM-B]
4
1
Power supply:AC
100-240V
2
LED display
3
DMX: confirm button; FCN: function button; ▲▼◀▶direction
button
6
Power indicator
4、5、8
Signal input:
DMX-512/RS485
7
Communication indicator
9
Counterclockwise shortcut
button and indicator
10
clockwise shortcut button
and indicator
11
Control output
1-5 Wiring Diagram
AC Motor Wiring:
E N V F R N
N
V

EDX-B02D [EUM-B]
5
DC Motor Wiring:
E N V
F R G
2. Operation
2-1 Initialization
STEP-1: hold 【▲】and【▼】to power the device until LED displays:
STEP-2: Press【DMX】to initial:
STEP-3: then enter the main screen:
Press 【FCN】after STEP-2 can stop initialization.
2-2 DMX Address Setting
Standard DMX console can output 512 channels and EDX-B02D can use consecutive 2
channels out of them as the output channel. In these 2 channels, the first channel No. is start
channel address.
G
V +

EDX-B02D [EUM-B]
6
STEP-1: On the main page, press【DMX】+【▲】or【▼】to set the DMX address.
For example, change the DMX address from 001 to 003
When the DMX signal inputs, LED displays:
STEP-2: Release button to back.
2-3 Motor Control
On the main page , hold【▲】to start the motor rotate clockwise ; hold【▼】to start
the motor rotate counterclockwise; release【▲】or【▼】, the motor will stop rotating.
2-4 Accept/Refuse DMX Signal
STEP-1: On the main page, press【FCN】3 times to enter the screen:
STEP-2: Press【▲】or【▼】to select ON/OFF:
In which:
ON—— Refuse external DMX signal
OFF—— Accept external DMX signal
STEP-4: After setting, press【DMX】to save, press 【FCN】to exit.

EDX-B02D [EUM-B]
7
2-5 ID No. Setting
Each EDX series device must have a ID No..When one device is working alone, there is no
need to adjust the ID No., but when several devices are working together, each device must
have a different ID No.
STEP-1: On the main page, press【FCN】twice to enter ID NO. setting.
STEP-2: Press【▲】or【▼】to change ID NO.. (Up to 999)
STEP-3: After setting, press【DMX】to save, press 【FCN】to exit.
2-6 Zone Setting
Definition of zone: The device must set the Zone No. before using, which consists of two parts,
one is the zone no. and another is the start channel address.
2-6-1 Single/Multi Zone Setting
STEP-1:On the main page, press【FUNC】7 times to enter Zone setting.
STEP-2: Press 【▲】or【▼】to choose ON or OF
In which:
ON—Multi Zone state
OF—Single Zone state
STEP-3: After setting, press【DMX】to save, press 【FCN】to exit.
2-6-2 Single Zone Setting
STEP-1: On the main page, press【FCN】once to enter single zone setting. The cursor
will blink:
Blink
Blink
Blink, zone is 1
Blink, ID NO. is 1

EDX-B02D [EUM-B]
8
STEP-2: Press【▲】or【▼】to change the zone no. (Up to 99 Zones)
STEP-3: Press【◀】or【▶】to shift between zone and start channel option; press【◀】
to shift to startchannel option, and then press【▲】or【▼】can modify the zone
No. (Up to 99)
STEP-4: After setting, press【DMX】to save, press 【FCN】to exit.
2-6-3 Multi Zone Setting
STEP-1: On the main page, press【FCN】8 times to enter multi zone setting. Thecursor
will blink:
STEP-2: Press 【▲】or【▼】can modify channel;
STEP-3: Press 【◀】or【▶】to shift to zone select state. The cursor will blink:
STEP-4: Press 【▲】or【▼】can choose channel zone (Up to 99 Zones);
STEP-5: Press 【◀】or【▶】to shift to startchannel select. Thecursor will blink in the
start channel option:
STEP-6: Press 【▲】or【▼】can choose start channel (Up to 255)
STEP-7: After setting, press【DMX】to save, press 【FCN】to exit.
2-7 Scene Setting
STEP-1: On the main page, press【FCN】five times to enter channel edit status.
Blink, start channel is 1
Blink, channel is 1
Blink, zone is 1
Blink, start channel is 1
Blink, channel 1

EDX-B02D [EUM-B]
9
STEP-2: Press【▲】or【▼】to select channel
STEP-3: Press【◀】or【▶】to shift to LEVEL setting status of channel
STEP-4: Press【▲】or【▼】to modify LEVEL 0-FL of channel
2-8 Scene Save and Recall
STEP-1: According to 2-7, press 【DMX】to enter scene save screen:
STEP-2: Press【▲】 or【▼】to select the desired scene No., and save the current
channel status as any scene (SC1-6)
STEP-3: After setting, press【DMX】to save, press 【FCN】to exit.
2-9 Scene Duration Setting
STEP-1: On the main page, press【FCN】four times to enter Scene Duration Setting.
The cursor will blink:
STEP-2: Press【▲】 or【▼】to select scene No., and can select any scene (SC1-6)
STEP-3: Press【◀】or【▶】to shift to scene duration setting status:
STEP-4: Press【▲】 or【▼】to select scene duration(1-99s) or any one of infinity.
Blink, the current LEVEL is 50, the motor stops.
Blink, the current LEVEL is 75, the motor
rotates clockwise.
Blink, scene 1
Blink, scene duration scene is 10s

EDX-B02D [EUM-B]
10
2-10 Motor Rotate Setting
STEP-1: On the main page, press【FCN】six times to enter motor operation status
setting. The cursor will blink:
STEP-2: Press【▲】 or【▼】to select channel
STEP-3: Press【◀】or【▶】to shift to motor rotate setting status:
STEP-4: Press【▲】 or【▼】to select UP/DOWN
In which:
UP —motor rotates clockwise
DOWN—motor rotates counterclockwise
STEP-5: Press【◀】or【▶】to shift to motor operation setting screen:
STEP-6: Press【▲】 or【▼】to select motor rotate time(1-99s) or any one of infinity
STEP-7: After setting, press【DMX】to save, press 【FCN】to exit.
2-11 Check Software Version
On the main page, press【FUNC】nine times to check the current software version.
Blink, channel 1
Blink, UP means motor rotates clockwise
Blink, motor operating time is 10s

EDX-B02D [EUM-B]
11
Limited Warranty
1. Lite-Puter is only responsible for the product itself.
2. Lite-Puter warrants to repair any manufacturing defects within one year of distribution date.
3. Lite-Puter does not offer on-site service. Should a defect appear in Lite-Puter’s product, please deliver
the product to local distributors or Taiwan Headquarters.
4. This Limited Warranty does not cover:
a. Any fault caused by false usage or imprudence (collision, inadequate installation or adjustment,
insufficient ventilation, or improper repairs)
b. Force majeure factors (flooding, earthquake, volcanic eruption, or other factors beyond Lite-Puter’s
control).
c. Labor costs incurred in diagnosis of defects; installation, reinstallation, wiring, rewiring, repairing,
adjustment, or reprogramming of a product; or any other consequential expenses.
d. Other Lite-Puter or non-Lite-Puter products or devices offered, packaged, or sold with the product.
5. Lite-Puter does not warrant that the product will operate without interruption or free of error.
World Headquarters:
Lite-Puter Enterprise Co., Ltd.
Address: 11F, No. 189, Gangqian Rd., Neihu Dist., Taipei City 11494, Taiwan.
Tel: +886-2-27998099
Fax: +886-2-27993828
Website: www.liteputer.com.tw
E-mail: sales@liteputer.com.tw
Shanghai Factory:
Lite-Puter Technology(Shanghai)Co.,Ltd.
Address: No. 375, Xingmei Road, Minhang Dist., Shanghai, China
Zip Code: 200237
Tel: +86-21-54408210
Fax: +86-21-54403376
Website: www.liteputer.com.tw
E-mail: sales_china@liteputer.com.tw
Table of contents
Other Lite-Puter Controllers manuals
Popular Controllers manuals by other brands

Hitachi
Hitachi ATW-YCC-03 Installation and operation manual

DELTA DORE
DELTA DORE GP 40 Installation

RLE Technologies
RLE Technologies SeaHawk LD5200 quick start guide

Pinnacle Systems, Inc.
Pinnacle Systems, Inc. NSD-TR-01 Installation and operation manual

Xantrex
Xantrex LINK 2000-R owner's manual

MKS
MKS BEA AFA Series Operating and maintenance instruction

Oase
Oase InScenio operating instructions

Georges Renault
Georges Renault CVIS II Operator's manual

Gruppo Ferroli
Gruppo Ferroli FZ4B Use and Installation Instructions

RECO
RECO RM-BV4 Micro DP Documentation

Toptech
Toptech FCM II installation guide

Der Mann mit der Maschine
Der Mann mit der Maschine DROID MASTER user manual