LOBSTER R1A1 User manual

AIR RIVETER
INSTRUCTION MANUAL
Professional model of air riveter to install blind rivets.
Thank you very much for purchasing “LOBSTER” air riveter.
To ensure correct operation, please read this instruction manual carefully, and keep it in a safe place
for later reference.
In
case
you
have
some
trouble
and
failure,
please
refer
“Troubleshooting”
in
the Instruction
Manual.
Lobtex Co.,Ltd. has the copyright of this manual. It is prohibited to publish, copy or translate to other
language without prior consent.
CONTENTS
IMPORTANT
SAFETY
INSTRUCTIONS.................................1
NOMENCLATURE .............................4
TECHNICAL
DATA ...........................5
PREPARATION
BEFORE
USE .......6
OPERATING
THE
AIR
RIVETER ....8
MAINTENANCE.................................9
EXPLODED VIEW............................17
TROUBLESHOOTING .....................16
STORAGE .......................................19
ORDERING
PARTS .........................19
PARTS
LIST .....................................18
International Marketing & Sales Division
12-8 Shijo-cho, Higashi-Osaka City
Osaka 579-8053, Japan
Telephone: +81(72)981-7466
Telefacs: +81(72)981-9420
URL http://www.lobtex.co.jp/
MANUFACTURER
PRINTED IN JAPAN
ⱥㄒ㸭(1*/,6+
BUILT-IN ON-DEMAND
VACUUM SYSTEM
R1A1(A)

IMPORTANT
SAFETY
INSTRUCTIONS
یBe sure to read the following Important Safety Instructions carefully and make sure that you
understand them thoroughly before using this tool.
یAlways wear eye-protection at all times during use. If this is not observed, the cut mandrels
may eject out when the rivets are cut and cause serious injury.
یThis is the safety alert symbol. It is used to alert you to potential personal injury hazards.
Obey all safety messages that follow this symbol to avoid possible injury or death.
یThe Important Safety Instructions are divided into and .
The differences between these two levels are described below.
CAUTION
WARNING
: Indicates a potentially hazardous situation which, if not avoided, could result in death
or serious injury to the operator.
Important note about the installation, handling and maintenance of this product.
:
:
Indicates a potentially hazardous situation which, if not avoided, may result in
moderate injury to the operator or physical damage.
Moreover, failure to follow the instructions marked with the symbol or cautions without
a symbol which appear in the text of this manual may also have serious results in some
cases. Always be sure to observe the instructions given in the Important Safety Instructions.
CAUTION
CAUTION
CAUTION
WARNING
1.
The
air
pressure
should
be
kept
within
the
range
of
0.5
to
0.6
MPa
(5
to
6
kgf/cm
2
,
71
to
85
psi).
࣭If an air pressure which is greater than this is used, the tool may become damaged, and injury or
ࠉdamage to property may result.
2.
Never
look
into
the
nosepiece
of
the
tool,
and
never
point
the
nosepiece
toward
other
persons.
࣭If the tool is used while the cut mandrels are still inside the tool not being ejected, these mandrels
may be ejected from the tool’s nosepiece during use and cause serious injury.
3. Always
attach
the
tank case
unit
before
use.
࣭If you work without attaching the tank case unit, there is a risk that the mandrel of rivet that has
been cut is not discharged, and will be clogged inside exhaust pipe,causing a fault of the equipment.
Also, these mandrels may be ejected from the tool’s nosepiece during use and cause serious injury.
4. Wear
protective
glasses
during
use.
࣭Failure to do so may result in an accident or personal injury in case that a rivet or a piece of
cut-mandrels jumps out toward you.
ࠉ5. Make
sure
that
the
tool
and
the
air
source
are
connected
securely.
࣭If the threads of the joints do not match or if the screws are not inserted far enough, the air hose
may become disconnected during use and injury may result.
࣭Use hose bands to securely connect the air hose joint and air hose. If they are not connected
securely enough, the air hose may become disconnected during use and injury may result.
6. Turn
off
the
air
supply
before
disconnecting
the
tool
from
the
air
source.
࣭Compressed air may cause the air hose to whip around, and injury may result.
7. Check
that
all
the
tool
parts
are
free
from
damage
before
use.
Any
damaged
parts
should
be
repaired
before
the
tool
is
used.
࣭If the tool is used while any parts are still damaged, injury may result.
࣭If the tool is damaged by objects being dropped onto it, for instance, the damaged part may break
and accident or injury may result.
࣭Don't pull and drag the tool by the air hose. It may trigger some damages on the tool body,
breakage of Rotary Joint or some other defects and lead serious troubles with injuries.
8. If
using
in
elevated
locations,
use
a
safety
harness,
and
take
care
to
avoid
dropping
rivets
or
the
tool
itself.
࣭Accident or injury may result if this practice is not followed.
یAfter reading this manual, keep it in a safe place where it is easily accessible to all users.
WARNING
ⱥㄒ㸭(1*/,6+
1
Note

1. Before
starting
maintenance
or
disassembling
the
unit
to
replace
parts,
be
sure
to
stop
air
supply.
࣭Performing maintenance or disassembly with air supplied may cause a part to jump out, oil to
squirt out, or the unit to perform unexpected behavior, and may result in an accident or personal
injury.
3.
2.
Do
not
operate
the
tool
with
the
Frame
Head
removed.
Tighten
the
Bleed
Plug
firmly
before
use.
࣭Items such as fingers may become caught in the mechanism.
࣭If the Bleed Plug is loose or coming off during use, oil may squirt out resulting in an accident or
personal injury.
4. Do
not
bring
your
face
close
to
the
exhaust ports.
࣭Pressurized air containing fine particles is discharged from the exhaust ports during use. Keep
eyes away from this area.
5. Avoid
skin
contact
with
substances
such
as
hydraulic
oil,
lubricating
oil
and
grease.
࣭Such substances may cause inflammation of the skin. If they come into contact with your skin,
wash the affected area thoroughly.
6. The
parts
to
be
used
must
be
those
supplied
from
us
or
recommended
by
us.
Select
and
attach
parts
applicable
to
your
rivet.
࣭Otherwise the unit may not produce maximum performance and may sometimes malfunction
resulting in an accident or personal injury.
7. Make
sure
that
the
workplace
is
safe,
clean
and
organized.
࣭Accidents can easily occur in untidy workplaces.
࣭If the cutmandrels are allowed to fall onto the floor, you may slip on them, and injury may result.
8. Avoid
uncomfortable
postures
while
working.
࣭You may fall down and injury may result.
9. Keep
people
who
are
not
involved
in
work
away
from
the
workplace.
࣭Accidents or injury may result.
10. Maintain
the
tool
with
proper
care.
࣭Refer to the Instruction Manual for details on replacing parts and attachments, otherwise injury may
occur.
11. Keep
the
handgrip
always
dry
and
clean,
and
avoid
adhesion
of
oil
and
grease.
࣭Otherwise the grip may slip from your hand resulting in falling of the unit.
12. Do
not
leave
the
floor
littered
with
cut mandrels.
࣭Cut mandrels are dangerous because their ends are sharp. Stepping on them is also dangerous
easily causing a slip and fall accident.
13. Use
the
tool
carefully
and
concentrate
on
correct
operation
at
all
times.
࣭Use the tool with proper care, paying full attention to methods of handling and operation and
ࠉsurrounding conditions. Accidents and injury may result if this practice is not followed.
࣭Use common sense at all times, otherwise accidents or injury may result.
࣭When you are tired, do not use the tool, otherwise accidents or injury may result.
14.
Ask
Lobtex
to
carry
out
any
repair
work
required.
࣭Repair work should only be carried out by a qualified technician. Please contact your nearestࠉࠉ“LOBSTER” distributor, representative, or direct to Lobtex Co., Ltd., Osaka. If the tool is repaired
by someone without the necessary qualifications and experience, the tool may not perform to
optimum standards, and accidents or injury may result.
15.
Do
not
attempt
to
modify
the
tool.
࣭Unauthorized modifications may cause malfunctions which can lead to accidents or injury.
16.
Only
for
EU
countries,
do
not
dispose
of
electric
tools
together
with
household
waste
material
!
࣭In observance of European Directive 2002/96/EC on waste electrical and electronic equipment
and its implementation in accordance with national law, electric tools that have reached the end
of their life must be collected separately and returned to an environmentally compatible recycling
facility.
17.
Important
information
and
clue
about
the
use
are
listed
in
main
body
label. When
contents
cannot
read
by
contamination
or
by
the
damage
of
the
label,
please
order
a
new
label
and
put
it.
࣭The new label could be ordered from us(Lobtex)via distributor.
CAUTION
ⱥㄒ㸭(1*/,6+
2

ⱥㄒ㸭(1*/,6+
3$%01.:7<82/=ЎЎN
CAUTION
࣭Wear protective goggles or safety glasses.
࣭When this product is damaged, please do not use.
20. This product is an exclusive tool for Blind Rivet fastening two boards by riveting.
We do not design, manufacture or sell intending to other applications.
21. For the maintenance of the main body, for every 30,000 installation of the fastener or
in one year.
22. Only qualified and trained operators should install, adjust or use the assembly power
tool for non-threaded mechanical fasteners.
23. Slips, trips and falls are major causes of workplace injury. Be aware of slippery surfaces
caused by use of the tool and also of trip hazards caused by the air line or hydraulic
hose.
24. Proceed with care in unfamiliar surroundings. There can be hidden hazards, such as
electricity or other utility lines.
25. This assembly power tool is not intended for use in potentially explosive atmospheres.
26. This assembly power tool is not insulated against contact with electric power.
27. Ensure that there are no electrical cables, gas pipes, etc.,which can cause a hazard if
damaged by use of the tool.
28. If you experience numbness, tingling, pain or whitening of the skin in your fingers or
hands, stop using the assembly power tool, tell your employer and consult a physician.
29. Air under pressure can cause severe injury.
30. Always check for damaged or loose hoses and fittings.
33. The regular preventative maintenance shall be carried out, for instance after a specilfied
time of operation, a specified number of cycles/operations or a stated number of times
per year.
34. When you handle hydraulic oil or grease, obtain the Safety Data Sheet (SDS) from the
supplier, and follow the described instructions.
35. When disposing this tool, please follow the regulations and the rules of the country and
autonomous community.
19. This product is a tool for exclusive use of the professional business. When you are
the one who uses this tools for the first time, please receive an instruction from the
one who have already used this tools before, also please read the Instruction Manual
carefully and understand the content.
18.
The
production
date
of
this
product
is
shown
brevity
code
below
the
tools.(on
page5)
How
to
check
manufactured
date
An English character
(Example) year: 2 0 1 4 month: 8 ЍN Y
A year/month of manufacture
࣭You may fall down and injury may result.
࣭Whipping hoses can cause severe injury.
31. Handle this product in a careful manner.
࣭Rough handling may cause an accident and failure of the tool. Do not throw, drop, nor give
shock to this product.
32. Do not carry nor trail this product by pulling a joint hose.
࣭It may cause a damage to the hose, a failure and an abnormal action of this product.
Then, an accident and injury may result.
࣭Always shut off air supply, drain hose of air pressure and disconnect tool from air supply when
not in use, before changing accessories or when making repairs.
࣭Never direct air at yourself or anyone else.
Y

ⱥㄒ㸭(1*/,6+
4
NOMENCLATURE
Tank Joint
Tank Case Unit
Bleed Plug Frame Head ‘CJM’
Trigger
Grip Cover
Vacuum Button
Cylinder Cap
Cylinder Cup
Jaw Pusher Spring
Rotary Joint
(Screw size: Parallel pipe thread G1/4)
Nosepiece
FRAME
HEAD
INTERNAL
PARTS
Jaw Pusher
O-ring P6
O-ring P9
O-ring S10
Guide Tube ‘SUS’
Jaw Case ‘CJM’
Ultra Jaws ‘M’
Jaw Case HeadFrame Head ‘CJM’Nosepiece
chamfered

ⱥㄒ㸭(1*/,6+
5
TECHNICAL DATA
Model
No.
Weight kg (lbs)
Operating
air
pressure
Dimensions
(LengthHeightWidth) mm
Air
consumption
per
minute
L(cu.ft.)
Tool
stroke mm (inch)
Traction
power
at
0.59
MPa
kN (kgf)
1.1 (2.43)
R1A1㸦$㸧297265106
68 (2.4) (on the occasion of vacuum is working.)
19 (3/4)
9.0 (917)
Air consumption calculation method
Use the following calculation method to obtain the required air consumption, and select the
compressor accordingly.
Make sure that this corresponds to the compressor discharge capacity (per minute).
Required
air
consumption Air
consumption
per
minute
Applicable
rivets ȭmm
(rivet
diameters) ȭinch
0.5 ~ 0.6 MPa (5 ~ 6 kgf/cm2, 71 ~ 85 psi.)
2.4, 3.2, 4.0, 4.8
3/32, 1/8, 5/32, 3/16
Operating
environment
Temperature
Relative humidity
Sound Pressure level (Lpa)
Vibration Emission value
The date of manufacture
Serial number
(Display example)
N Y 1 2 3 4
Warning Label
AF
22
mm
Air
intake
(Rotary
joint)
4Υto 35Υ80%RH max. (No condensation)
73 dB
Size of screw G1/4 (PF1/4)
Less than equal to 2.5m/sec2
ȭȭ
ȭەProduct specifications and design are subject to change for improvement without notice.
ەWeight and dimensions given are standard values. Actual products may differ slightly from
the values given.
ەThe warning lavel is located on the side of the main unic Cylinder Cup.
ەThe production date of this product is indicated on the top surface of Cylinder Cap with brevity
code. Please refer to the page 3 how to read its brevity code.
ەThe serial number of this product is indicated on the top surface of Cylinder Cap with numbers.
Note
Note

ⱥㄒ㸭(1*/,6+
6
Tank Joint
Tank Case Unit
Vacuum Button
Exhaust Port
Set
the
Tank
Case
Unit
to
the
Tank
Joint.
Push to fit the Tank Case Unit to the Tank Joint as shown in the figure, and turn the Tank Case
Unit to the right until it is firmly fixed.
Set
up
the
compressor,
and
be
sure
to
install
an
air
filter,
air
regulator
and
air
lubricator
(3-device
set)
between
the
compressor
and
the
tool.
PREPARATION
BEFORE
USE
1
2
Air regulator
Air filter
Air lubricator
Spool Cap
Rotary Joint
ەAlways
attach
the
tank
case
unit
before
use.
If you work without attaching the tank case unit, there is a risk that the mandrel of rivet that has been
cut is not discharged, and will be clogged inside exhaust pipe, causing a fault of the equipment.
Also,
these mandrels may be ejected from the tool’s nosepiece during use and cause serious injury.
WARNING
ەWhen you turn the Vacuum Button ON, air comes out of the Exhaust Port on the side of the
Tank Case Unit.
ەThe Exhaust Port can face to any of the 4 directions, so change the direction as your preference.
Note ەAdjust the drip-feed amount of the air lubricator to the minimum setting.
ەIf moisture enters inside of the unit, it may freeze in cold temperature or accelerate degradation
of O-rings and packings, resulting in malfunction of the unit. To avoid that, use an air dryer as
necessary in addition to an air filter, regulator and an air lubricator (3-device set).
ەIf you attach the Rotary Joint to the opposite side, remove the Spool Cap and exchange the
positions.
Note ձղ

ⱥㄒ㸭(1*/,6+
7
4
3
Replace
the
nosepiece
and
guide
tube
as
indicated
below
to
conform
to
the
size
of
the
rivet
being
used.
Body (flange)
Mandrel (shaft)
Rivet diameter
Use
the
air
regulator
to
adjust
the
operating
air
pressure
to
0.5
~
0.6MPa
(5
~
6kgf/cm2,
71
~
87psi).
Rivet
Dia. Nosepiece Guide
Tube
2.4 mm (3/32”)
3.2 mm (1/8”)
4.0 mm (5/32”)
4.8 mm (3/16”)
3.2
2.4
4.0
4.8
ە
The
air
pressure
should
be
kept
within
the
range
of
0.5
to
0.6
MPa
(5
to
6
kgf/cm
2
,
71
to
87
psi).
WARNING
If an air pressure which is greater than this is used, the tool may become damaged, and injury or
damage to property may result.
ەIf the diameter of your stainless rivet (NST, NSS) is 4.8mm(3/16"), set the air pressure to
ࠉ0.54 ~ 0.6 MPa (5.5 ~ 6.0 kgf/cm2, 78
~
87
psi).
ەIf the air pressure is too high, damage to parts may occur. If the pressure is too low, some
size of the rivet may not be correctly installed (cut).
Note ەRefer to “Jaw maintenance” on page 9 for details on replacing the guide tube.
Note ەShaded areas indicate parts which are installed in the tool as standard accessories.
ەConform the size to be used, and replace the nose piece with the corresponding one.
If you use the Nosepiece improperly, cut mandrels may not be ejected normally after fixing
and may clog inside or come up to the surface. That may also badly affect finishing of rivets.
To avoid that, be sure to use an appropriate Nosepiece.
ەApplicable rivet size is marked on the hexagon part of Nosepiece.
ەA Guide Tube is not necessary for 4.0mm and 4.8mm rivets. Be sure to remove the Guide
Tube before use.
Note
Guide Tube 'SUS'
(silver)
A Guide Tube is not
necessary for 4.0mm
and 4.8mm rivets.
Be sure to remove the
Guide Tube before use.
chamfered

ⱥㄒ㸭(1*/,6+
8
ەAlways attach the tank case unit before use.
There is a risk that the spent mandrel will be clogged inside, causing a fault of the equipment.
WARNING
㸺Operating
temperature㸼The ambient temperature for working is within the range of 4~35Υ(39.2~95°F). Although condensation may occur on the lower part of Grip Cover depending on
the number of rivets used, and the usage environment, that does not indicate a defect.
Wipe off around the part before using the unit.
Note ەMake sure that the cut mandrel has been completely removed before proceeding to
the next riveting.
Note ەAt the time and during activation of the trigger, a small amount of air
may leak from the trigger portion. This is not a malfunction.
Note
Select a suitable size of rivet for the workpiece to be riveted.
Replace the nosepiece with one which matches the size of the rivet to be used.
(Refer to item in “Preparation Before Use” on page 7.)
Drill a hole of appropriate size (0.1 to 0.2mm larger than the diameter
of the rivet) into the workpiece.
After inserting the mandrel (shaft) of the rivet into the nosepiece,
insert the head of the rivet into the hole.
Lightly fit the end of riveting tool to the base material. Make sure that
there is no space in the base material and other things, and then
activate the trigger.
The rivet will be installed into the workpiece.
4
Release the trigger. The cut mandrel (shaft) will then be drawn into the tank case
unit.
When
the
tank
is
about
half
full
with
cut
mandrels,
remove
the
Tank
Case
Unit
by
turning
it
to
the
left
after
stopping
vacuum
function,
and
discard
the
cut
mandrels
collected
inside.
1
2
3
5
4
6
7
8
9㸦1㸧Make sure that the Tank Case Unit is set, and press the Vacuum
Button fully from the "ON" marking side to start vacuuming.
㸦2㸧Insert the mandrel of rivet into the end of riveter.
ەSome rivets have mandrels with sharp ends. Be careful not to injure your
fingers on these ends.
ەIf the button is not fully pressed, vacuuming power will be lower.
Note ەIf the tank becomes over half full, cut mandrels may be
obstructed by those inside the tank and may not normally be
collected, causing them to be left in the ejection pathway.
That will result in clogging of cut mandrels and air leakage
from the Nosepiece making the unit to be unusable.
Note
OPERATING
THE
AIR
RIVETER
Tank Case Unit
ձղ

ⱥㄒ㸭(1*/,6+
9
MAINTENANCE
After long periods of use, debris from cut mandrels and other foreign materials tend to build up in various
parts of the tool, and the hydraulic oil level also drops, both of which can lead to operating problems.
The tool should be cleaned periodically.
Jaw
maintenance
Also
refer
to
this
section
when
replacing
parts.
1
2
3
Turn
off
the
air
supply.
Remove
the
Frame
Head
‘CJM’using
a
wrench
or
spanner
(AF22
mm).
Loosen
and
remove
the
Jaw
Case
Head
and
Jaw
Case
‘CJM’
using
spanners
(AF14
mm
and
AF15
mm)
or
other
tools.
The
following
parts
will
be
removed.
࣭Ultra Jaws ‘M’
࣭Jaw Pusher
(With two O-ring P6)
࣭Jaw Case ‘CJM’
(With O-ring S10)
࣭Guide Tube ‘SUS’
࣭Jaw Pusher Spring
4Wash
and
clean
the
parts
using
a
brush
and
kerosene
or
such
other
things.
DISASSEMBLY
CLEANING
RE-ASSEMBLY
5Assemble
the
parts
in
reverse
order
of
disassembly
and
fully
tighten
the
Jaw
Case
Head.
In
the
end,
attach
the
Frame
Head‘CJM’.
Jaw
Case
Head
(Cross
section)
Frame Head ‘CJM’
Jaw Case Head
(AF 14mm)
Jaw Case ‘CJM’
(AF 15mm)
Apply jaw lube
(lubricating oil)
Label of reminder to
securely tighten
Jaw Pusher Spring
Jaw Pusher
O-ring P6
O-ring P9
O-ring S10
Guide Tube ‘SUS’
Jaw Case ‘CJM’
Ultra Jaws ‘M’
Jaw Case Head
Frame Head ‘CJM’
Nosepiece
ەIn
case
you
have
some
trouble
and
failure,
please
refer
“Troubleshooting”
in
the Instruction
Manual.
Note ەIf debris builds up, the jaws will not move smoothly and normal operation will not be possible.
ەThe jaws should be cleaned on average once every 3,000 riveting operations.
Note ەApply LOBSTER lubricant oil JO-50 (separately sold: ISO VG150
containing molybdenum disulfide) to the back of Jaws or the
inside of Jaw Case Head.
ەAssembling the Guide Tube will be smoother if you turn and
insert the Guide Tube.
ەBe sure to assemble all of the parts and fasten the fastening
ࠉsections firmly.
ەJaw Case Head, Ultra Jaws ‘M’, Jaw Pusher, O-ring,
Jaw Case ‘CJM’, Guide Tube, and Jaw Pusher Spring
are consumable items. Replace them on a regular base.
ەPlease check periodically whether there is any slack of the
Frame Head 'CJM' during work. If you work after the Frame
Head 'CJM' is loosened , damage to the parts may occur.
ەR1A1 is installed highly durable Ultra Jaws ‘M’.
ࠉBe sure to specify Ultra jaws ‘M’ as replacement parts for this model.
Note
ەBefore
starting
maintenance
or
disassembling
the
unit
to
replace
parts,
be
sure
to
stop
air
supply.
Performing maintenance or disassembly with air supplied may cause a part to jump out, oil to squirt
out, or the unit to perform unexpected behavior, and may result in an accident or personal injury.
ەDo
not
operate
the
tool
with
the
Frame
Head
‘CJM’
removed.
Items such as fingers may become caught in the mechanism.
CAUTION
chamfered

ⱥㄒ㸭(1*/,6+
10
Replacement of the Nosepiece
1
2
Turn
off
air
supply.
Remove
the
Nosepiece
from
the
Frame
Head
‘CJM’
using
a
wrench
or
spanner.
DISASSEMBLY
3Firmly
set
a
Nosepiece
applicable
to
the
rivet
size
to
the
Frame
Head
‘CJM’.
RE-ASSEMBLY
Frame Head ‘CJM’
(AF 22mm)
Nosepiece
(AF 10mm)
Replacement of the Tank Case Sponge
1
2
Turn
off
air
supply.
Remove
the
Tank
Case
Unit
by
turning
it
in
a
counterclockwise
direction.
3Remove
the
Tank
Case
Sponge
in
the
direction
of
the
arrow.
DISASSEMBLY
4Assemble
the
tank
case
sponge
and
Tank
Case
Unit
in
reverse
order
of
disassembly.
RE-ASSEMBLY
Tank Case Unit
Tank Case Sponge
Cross-section
view
of
Tank
Case
Unit
ձղەBefore
starting
maintenance
or
disassembling
the
unit
to
replace
parts,
be
sure
to
stop
air
supply.
Performing maintenance or disassembly with air supplied may cause a part to jump out, oil to squirt
out, or the unit to perform unexpected behavior, and may result in an accident or personal injury.
CAUTION
ەBefore
starting
maintenance
or
disassembling
the
unit
to
replace
parts,
be
sure
to
stop
air
supply.
Performing maintenance or disassembly with air supplied may cause a part to jump out, oil to squirt
out, or the unit to perform unexpected behavior, and may result in an accident or personal injury.
CAUTION
ەIf the Nosepiece is damaged, replace it with a new one.
ەIf you change the rivet size, replace with an applicable Nosepiece.
Note ەIf power of vacuuming rivets becomes lower or the tank case sponge is damaged, replace with
a new tank case sponge.
Note ەPlease check periodically whether there is any slack of a nosepiece during work.
ەIf you work after the nosepiece is loosened, damage to the parts may occur.
Note ەTank case sponge is a consumable item. Replace it on a regular base.
Note


ⱥㄒ㸭(1*/,6+
12
RE-ASSEMBLY
9
Push
and
insert
the
Air
Piston
Unit
into
the
oil
supply
port
and
manually
perform
a
piston
motion
for
several
times.
Wipe
off
hydraulic
oil
spilling
out
of
the
oil
supply
port.
Attach
the
Cylinder
Cup
on
the
Air
Piston
Unit,
and
keeping
pressing
it
down
tighten
the
4
hex
socket
screws.
After
assembled
Frame Head with Frame A, turn
the unit
as the Bleed
Plug
(hex
socket
bolt)
comes
to
the
upper
side.
Then, loosen
it
using
a hex
key
wrench
(AF
4mm)
in
order
to
let
excessive hydraulic
oil
and
air
(bubble)
out.
After
making
sure
that
hydraulic
oil
no
longer
comes
out,
tighten
the
Bleed
Plug
again.
Wipe
off
hydraulic
oil
adhering
to
the
main
body
or
spilling
out
before
use.
10
11
12
Air Piston Unit
Oil supply port
Cylinder Cup
Bleed Plug
Hex key
wrench
(AF 4mm)
O-ring SS9.5 Hex socket screw
(x4)
O-ring
Hex key wrench
(AF 4mm)
8Apply
grease
to
the
O-Ring
and
rod
of
Air
Piston
Unit
and
to
the
inside
of
Cylinder
Cup
using
brush.
Cylinder Cup
Apply grease
Apply grease
Air Piston Unit
ەAvoid
skin
contact
with
substances
such
as
hydraulic
oil,
lubricating
oil
and
grease.
Such substances may cause inflammation of the skin. If they come into contact with your skin,
wash the affected area thoroughly.
ەMaintain
the
tool
with
due
care.
Refer to the Instruction Manual for details on replacing parts and attachments, otherwise injury may
occur.
CAUTION
ەBefore assembling, be sure to apply lubricant such as grease to each sliding section.
ەRecommended grease is GreaseJUDGH1~2.
Note ەAssemble in reverse order of disassembly.
ەMake sure the O-ring SS9.5 is surely set in the counterbore.
Note ەNote that hydraulic oil may squirt out when you loosen the
ࠉBleed Plug.
ەThe work should be done by necessity after feeding hydraulic
oil. Otherwise there may be detrimental to the tool in loading
rivet or breakage of Frame.
Note ەDuring disassembly/assembly, be careful to prevent cutting dusts of metal and
other objects from getting into the hydraulic oil and Air Cylinder.
Note

ⱥㄒ㸭(1*/,6+
13
Cleaning and Oil Supply of Air Valve
1
2
3
4
Air Valve Head
Lock Plate
Air Valve Head Lock Plate
Urethane Tube
Plier ձղەIf the Air Valve is clogged with cut swarf, it has adverse influence on smooth operation and
durability.
5Remove the Air Valve Head, and pass a wire that has been bent like a hook
through the exhaust port to raise the Air Valve to remove it.
6Apply grease to the O-ring of
the Air Valve.
ەRecommended grease is Grease grade 1~2.
ەWhen removing the Air Valve, be careful not to damage the O-ring with the wire.
ەAlso, if the Air Valve Head Lock Plate is mounted in the direction opposite to that in the
figure below, push the tube to move it aside in the same manner, and remove the plate
by using pliers, etc.
ەBefore starting maintenance or disassembling the unit to replace parts, be sure to stop air
supply.
Performing maintenance or disassembly with air supplied may cause a part to jump out, oil to squirt
out, or the unit to perform unexpected behavior, and may result in an accident or personal injury.
ەAvoid skin contact with substances such as hydraulic oil, lubricating oil and grease.
Such substances may cause inflammation of the skin. If they come into contact with your skin, wash
the affected area thoroughly.
CAUTION
Turn off the air supply.
Remove cross recessed pan head screws (2 pieces) and tapping screws (3 pieces)
on the side of the Grip Cover by using a Phillips screwdriver.
Remove the Grip Cover, Trigger, Switch, and Silencer Sponge in this sequence.
DISASSEMBLY
RE-ASSEMBLY
Apply grease
Wire
Exhaust port
Air Valve
Air Valve
Tapping screw
(x3)
Grip Cover
Cross recessed pan
head screw
(x2)
Switch
Trigger
Silencer
Sponge
While moving the Urethane Tube forward by pushing it with a finger, remove the Air
Valve Head Lock Plate by using pliers, etc.
Note
Note
Note
Note
Air Valve Head

ⱥㄒ㸭(1*/,6+
14
1
2
6Cleaning the Mandrel Shutter section
7Attach the Air Valve and the Air Valve Head, and mount the Air Valve Head
Lock Plate to the body by pinching it with pliers, etc.
Remove the Tank Case Unit by turning it in
a counterclockwise direction. ձղەIf the Mandrel Shutter is clogged with cut swarf, the mandrel cannot be discharged.
ەPush the Air Valve Head securely to the end.
ەWhen mounting the Air Valve Head Lock Plate, move the Urethane Tube aside by
pushing it with a finger.
8
Mount the parts to the frame by following the procedure of in reverse, and tighten the
cross recessed pan head screws and the tapping screws by using a Phillips screwdriver.
ەAttach the Grip Cover with the Silencer Sponge around the body.
Grip Cover
Plier
Air Valve Head
Lock Plate
Switch
Trigger
Silencer
Sponge
3
RE-ASSEMBLY
DISASSEMBLY
Note
Note
Note
ەBefore starting maintenance or disassembling the unit to replace parts, be sure to stop air
supply.
Performing maintenance or disassembly with air supplied may cause a part to jump out, oil to squirt
out, or the unit to perform unexpected behavior, and may result in an accident or personal injury.
ەAvoid skin contact with substances such as hydraulic oil, lubricating oil and grease.
Such substances may cause inflammation of the skin. If they come into contact with your skin, wash
the affected area thoroughly.
CAUTION
Turn off the air supply.
Exhaust port
Silencer Sponge
Silencer Sponge
Tapping screw
(x3) Cross recessed pan
head screw
(x2)

ⱥㄒ㸭(1*/,6+
15
Apply grease
Apply grease to sliding part of Frame
Cap ‘A’.
Clean each part using a wast cloth and brush.
Attach the parts to the Frame Cap ‘A’ by following the sequence of in reverse.
5
6
7ەWith the Ball Chain attached to the Shutter Lever, push the Shutter Lever into the
mounting hole. ەAttach the Shutter Unit and
the Helical torsion spring of
shutter
to the Frame Cap ‘A’
as shown left.
Tighten two hex socket bolts in the Tank Joint
8
Hex socket bolt
(x2)
Hex key wrench
(AF 2.5mm)
Helical torsion spring
of shutter
Shutter Lever
Shutter Lever
Shutter Lever
Shutter Unit
Frame Cap ‘A’
Frame Cap ‘A’
Frame Cap ‘A’
(Sectional View)
Frame Cap ‘A’
Shutter Body
Ball Chain
Outer shaft of frame cap
4
Tank Joint
Tank Joint
CLEANING
RE-ASSEMBLY
Note
Note
ەMake sure to push down the Shutter Lever and check whether it will come back to
original position.
Note ەRecommended grease is
Grease grade 1~2.
ەApply one drop of grease.
ࠉIf applied ample amounts,
ࠉit may cause swarf to be
ࠉclogged to the Mandrel Shutter.
Note
3Remove two hex socket bolts in the Tank Joint by using
a hex key wrench (AF 2.5mm).
Hex key wrench
(AF 2.5mm)
Hex socket bolt
(x2)
Helical Torsion Spring of Shutter
Frame Cap ‘A’
Shutter Lever
Shutter Unit
Outer shaft of frame cap
Tank Joint
Remove the Tank Joint, Outer shaft of frame cap, Helical torsion spring of shutter,
Shutter Unit, Shutter Lever in this sequence.
4
DISASSEMBLY

ⱥㄒ㸭(1*/,6+
If a problem occurs, check the followings. If the problem persists after checking the items in the table
below, contact your nearest “LOBSTER” dealer or direct to us.
In
making
any
enquiries
about
this
product
or
requests
for
repair
work,
first
check
the
trouble-
shooting
items
below,
and
then
make
a
note
of
the
model
number,
the
usage
conditions
and
the
trouble
symptoms
in
as
much
detail
as
possible.
If
you
can
provide
this
kind
of
information,
it
will
contribute
to
reducing
the
amount
of
time
required
for
delivery
or
repairs
to
be
completed.
The
rivet
does
not
go
in,
or
the
cut
mandrel
does
not
come
out
after
riveting.
Number
of
triggers
operations
increases
before
riveting
is
complete.
Rivet
can
not
be
pulled.
Piston
does
not
operate,
or
returns
very
slowly,
or
operation
is
not
smooth.
The
suction
power
is
weak
and
the
cut
mandrels
(shafts)
cannot
be
drawn
ࠉ
out.
Wrong type of Nosepiece or Guide
Tube.
Nosepiece or Frame Head ‘CJM’ is
loose.
Jaw Case is incorrectly assembled.
Contact surface between Jaws and
Jaw Case ‘Head’ are not smooth.
(friction).
The inside of the Cylinder Cup is dirty
so that the Air Piston cannot return to
its proper position.
Oil filling was not performed correctly,
so that there is excess hydraulic oil
inside the tool.
The rivet length is not correct for the
workpiece thickness.
Compressor air pressure is incorrect.
Jaw Case is incorrectly assembled.
Jaws are worn.
Insufficient hydraulic oil, causing a
shorter stroke.
Insufficient and excess pressure of
supplied air.
Malfunction of Air Piston due to dirt or
oil shortage inside the Cylinder Cup.
The Vacuum Button is not fully
pressed.
Too many cut mandrels in the tank.
Cut mandrels clog in the Guide Tube.
The Tank Case Sponge is clogging.
The Guide Tube is not applicable to
the size of rivet used.
Replace with the correct part which
matches the rivet size.
(Refer to pages 7 and 10.)
Use a spanner or similar to tighten
securely.
Check the assembly procedure of parts
inside the Jaw Case. (Refer to page 9.)
Clean the Jaws and the inside of Jaw
Case Head, and apply “LOBSTER” brand
lubricant oil to the back of Jaws.
(Refer to page 9.)
Clean inside the Cylinder Cup, and apply
grease inside the cylinder and to the
O-ring. (Refer to pages 11 and 12.)
Loosen the Bleed Plug to allow the
excess hydraulic oil to drain out. (Refer to
pages 11 and 12.)
Mandrels clog up the Jaw Pusher or
the Guide Tube.
Eliminate the mandrels clogging in the
Jaw Case or the Guide Tube.
(Refer to page 9.)
Use rivet which match the workpiece
thickness.
Check the air pressure.
Check the assembly procedure of parts
inside the Jaw Case. (Refer to page 9.)
Replace the Jaws. (Refer to page 9.)
Add hydraulic oil. (Refer to pages 11
and 12.)
Adjust to obtain an appropriate pressure of
supplied air. (Refer to page 6.)
Clean inside the Cylinder Cup and
apply grease to the inner surface and
the O-ring. (Refer to pages 11 and 12.)
Press the Vacuum Button fully from the
"ON" side.
Remove the Tank Case Unit and
discard the cut mandrels.
Remove the Guide Tube and discard
the cut mandrels. (Refer to page 9.)
Clean or replace the Tank Case Sponge.
(Refer to page 10.)
Replace with a Guide Tube applicable to
the rivet used. Remove the Guide Tube
if your rivet size is ȭ4.0 orȭ4.8.
(Refer to pages 7 and 9.)
1
2
3
4
5
6
7
1
2
3
4
5
1
1
2
3
4
5
2
Trouble Cause Countermeasure
TROUBLESHOOTING
16



ⱥㄒ㸭(1*/,6+
STORAGE
ەStore in a place which is well-ventilated and free from excessive dust and humidity, and where there
is no danger that the tool will fall.
ەIf not using the tool for an extended period of time, carry out a maintenance inspection before storing
it away. (Refer to “Maintenance” on pages 9 ~ 15.)
ەTo increase the working life of the tool, it is recommended that you give it periodic overhauls.
ࠉContact the place of purchase or your nearest “LOBSTER” dealer for any overhauls and repair work
ࠉrequired. (A charge will be made for this service.)
Viscosity ISOࠉࠉ
: VG46
Viscosity Indexࠉࠉ: 113
Viscosity at 40
Υࠉ: 46 c.s.t.
Viscosity at 100
Υ
ࠉ
: 7.06 c.s.t.
Flash Pointࠉࠉ
ࠉ
: 228
RECOMMENDED OILS are:
Shell Tellus No. 46
Esso Teresso No. 46
Mobil D.T.E. 25 Oil (Medium)
HYDRAULIC
OIL
REQUIREMENTS
Use only clean hydraulic oil, as the viscosity of the oil used will affect tool performance.
“LOBSTER” brand Hydraulic Oil is supplied in a plastic filler bottle with the tool, and can also be obtained
from your “LOBSTER” dealer or agent in your town. If this is not possible, a good quality mineral oil with
the following properties should also be used.
19
ORDERING
PARTS
Indicate the tool model, part name, code no. and quantity as shown below when ordering.
Model
R1A1
R1A1
Part Name
Ultra Jaws (pair) ‘M’
Frame Head ‘CJM’
Code No. Qty.
1
1
10281
64055
ەWhen parts are modified for improvement, the older parts are kept in stock for a period of five
years.
Note
This manual suits for next models
1
Table of contents