logika 2 CPO White Manual

MOUNTING AND MAINTENANCE
INSTRUCTION
LOGIKA 2 ST_IM_ENG - Rev.09 of 16/09/16 Pag. 1 of 3
ST
Made in Italy
H
MOUNTING AND MAINTENANCE
The connection system, on pole/bracket or wall
mounting, allows to install the luminaire parallel
to the street. See related section for particular
fixing on pole, bracket or wall mounting.
To gain access to the electrical parts, unlock
and open the frame [Pic. 1]. The lower frame
will open, stopping in vertical position [Pic. 2].
To connect the luminaire to the electrical line,
insert the cable into the cable clamp and then
connect it to the on-load switch. Tighten the
cable clamp with an adjustable wrench of
25mm applying a twisting moment of 5Nm.
The feeding of the fitting must be done with a
bipolar cable with nominal diameter between 7
and 13 mm.
When it is necessary, you can take away the
gear tray, loosen the screws (A-B) and
disconnect the main and lamp connectors (C)
[see Pic. 3-4].
To reinsert the gear tray, put it right position
and then loosen the two screws and reinsert
the connectors.
The reflector has been designed to function
without fitting inclination. The lamp holder can
be placed in 6 different positions, to adapt the
photometrical solid to the width of the street
[Pic. 5]. See lamp holder plate drawing for
detailed position.
Pic. 3
Pic. 4
A
B
C
Pic. 5
Pic. 1
Pic. 2
A
This product complies with EU Directive 2002/95/EC.
The crossed-out wastebasket symbol on the appliance
means that at the end of its useful lifespan, the product
must be disposed of separately from ordinary
household wastes. The user is responsible for
delivering the appliance to an appropriate collection
facility at the end of its useful lifespan. Appropriate
separate collection to permit recycling, treatment and
environmentally compatible disposal helps prevent
negative impact on the environment and human health
and promotes recycling of the materials making up the
product. For more information on available collection
facilities, contact your local waste collection service.
INFORMATION TO THE CUSTOMERS
Directive 2002/96/EC (Waste Electrical and
Electronic Equipment - WEEE):
information for users.
Suggested height of installation
Model
Power [W]
H min [m]
H max [m]
70W
5
10
100W
7
12
150W
7
13
250W
7
14
Model
Wiring
Weight [gr]
Empty case
With control gear
70 W
7000
10400
100 W
10500
150 W
11500
250 W
12000

MOUNTING AND MAINTENANCE
INSTRUCTION
LOGIKA 2 ST_IM_ENG - Rev.09 of 16/09/16 Pag. 2 of 3
ST
Made in Italy
Post top mounting with MT bracket
Dimensions
Mounting
Mount the fixing support of LOGIKA 2 to the pole trough the four 8MA x 100 (A) screws. Tighten the four screws with a set
screw wrench of 6mm applying a twisting moment of 10Nm. Tighten the two screws 8MA x 14 with a set screw wrench of 5mm
applying a twisting moment of 10Nm to fix the fitting in horizontal position (B). See the MT mounting instruction for others
details.
Wall mounting
Dimensions
Mounting
Fix the LOGIKA 2 support to the plate trough the four 8MA x 100 screws (A). Tighten the four screws with a set screw wrench of
6mm applying a twisting moment of 10Nm. Tighten the two 8MA x 14 screws with a set screw wrench of 5mm applying a
twisting moment of 10Nm to fix the fitting in horizontal position (B). See the plate mounting instruction for others details.
Bracket mounting (MH - MI - MD)
Dimensions
Mounting
Put the LOGIKA 2 in position and fix it trough the 8MA x 14 screws (A). Tighten the screws with a set screw wrench of 5mm
applying a twisting moment of 10Nm (A). See the brackets mounting instruction for others details.
B
A
B
A
B
A
A
A

MOUNTING AND MAINTENANCE
INSTRUCTION
LOGIKA 2 ST_IM_ENG - Rev.09 of 16/09/16 Pag. 3 of 3
ST
Made in Italy
Ta = 30°C
CPO White
MHL
SHP
White Son
140W
70W
100W
150W
250W
70W
100W
150W
250W
50W
100W
Optic
Optic
Optic
Optic
Optic
Optic
Optic
Optic
Optic
Optic
Optic
E27
E40
G12
G22
PG12-1
PGX12-2
PGZ12
OPTIC
LAMP
HOLDER
LAMP TYPE
POS.
ST
E27
100W MHL-E
C rot
ST
E27
150W MHL-E
C rot
ST
E40
100W MHL-T
F
ST
E40
150W MHL-T
F
ST
E40
150W MHL-T
C1
ST
E40
250W MHL-T
E*
ST
E40
250W MHL-T
D**
ST
E40
100W SHP-T
F
ST
E40
150W SHP-T
F
ST
E40
250W SHP-T
D
ST
G12
150W MHL
C rot + spacer
ST
G12
250WMHL
C rot + spacer
ST
G22
250W MHL
C rot
ST
PG12-1
100W SHP-White
B rot
ST
PGX12-2
150W MHL
B rot
ST
PGZ12
140W CPO
B rot
ELECTRICAL LINE CONNECTION
< 25 mm
67mm
In order to insure double insulation
characteristic of the feeder cable, we
would advise that you first secure the
feeder cable to the internal cable
clamp, remove approximately 25mm of
external sheathing, and 6mm of
sheathing from the internal wires.
ATTENTION
a) The luminaire can be installed close to flammable surfaces.
b) Class II luminaires must be installed in such a way that it is impossible for any exposed metal part to come in contact with electrical components.
c) Luminaires for Metal Halide lamps must be always complete with its protective screen.
d) For luminaires with Metal Halide lamps, damaged protective shields can only be replaced with original AEC Illuminazione’s replacement shields.
e) On luminaires for Metal Halide lamps use only UV Stop protected lamps.
f) This luminaire has been designed and manufactured following all relevant standards. The installation must be done by experienced personnel and
following the instructions.
The present instruction paper has to be kept for any future maintenance operation on the luminaire.
Non compliance with the above will automatically release AEC Illuminazione Srl from any responsibility.
A- Ballast
L- Lamp
f–Fuse
(500V)
C- Capacitor
Z- Ignitor
WIRING SCHEME
SHP - White Son
MHL
WIRING SCHEME
Cosmopolis
Fluorescenti Compatte
L
N
L
Out
A
In
Form factor: 1,2
0.08 m2
Area exposed to the wind
0.21 m2
ST
Lamp holder plate support
Lamp holder plate
NORMAL position
ROTATED position
*: lamp with quartzitic burner
**: lamp with ceramic burner
This manual suits for next models
3
Popular Lantern manuals by other brands

Velleman
Velleman Perel CSOL06 user manual

Anslut
Anslut 420-069 User instructions

LUTEC
LUTEC TABLE CUBE 6908001331 user manual

Seto
Seto Aldebaran XLD Instructions for use

WE-EF
WE-EF ETC330-GB LED Installation and maintenance instructions

WHITECROFT LIGHTING
WHITECROFT LIGHTING Aerial Industry installation instructions

Home Decorators Collection
Home Decorators Collection HBWI9002S86A Use and care guide

HBI
HBI LEDOLOGY 110 CIRCUM manual

olympia electronics
olympia electronics GRL-29 WP manual

Wista
Wista AF100 installation guide

BEGA
BEGA 99 499 Installation and technical information

Gama Sonic
Gama Sonic BAYTOWN II instruction manual