LOOPER SYSTEMS RaMaLoop User manual



Contents
Contents ........................................................................................................................... 3
Thanks (acknowledgement) .............................................................................................. 4
Important instructions ...................................................................................................... 4
Introduction ...................................................................................................................... 5
Use of magnetic impulses ................................................................................................. 5
Package contents ..............................................................................................................
Optional accessories .........................................................................................................
Examples of use of contactless disposal of microorganisms ............................................ 7
Commissioning ................................................................................................................ 8
Description of connectors connection .............................................................................. 8
Description of indicators on LCD .................................................................................... 9
Device menu description ................................................................................................ 10
1 Frequencies generator - Frequencies generator settings ......................................... 10
2 LightLoop - antenna lighting settings ..................................................................... 12
3 Language - User Interface Language selection ....................................................... 13
4 Info - Listing of Diagnostic Data ............................................................................ 13
5 Return - return from the menu ................................................................................ 13
Control description ......................................................................................................... 15
Buttons functions ........................................................................................................... 15
1 Button function when displaying indicators on LCD ............................................. 15
2 Button function in menu ......................................................................................... 15
Basic controls ................................................................................................................. 17
LightLoop settings .......................................................................................................... 17
Frequency generator settings .......................................................................................... 18
1 How to run one program: ....................................................................................... 18
2 How to run 5 programs: .......................................................................................... 19
3 Generator settings for use with application coil ...................................................... 19
Language setting ............................................................................................................ 19
Service information ........................................................................................................ 20
Charging ......................................................................................................................... 20
Technical specifications .................................................................................................. 21
Safety and Ecology ......................................................................................................... 22
1 Applied electrical equipment .................................................................................. 22
2 Disposing of the battery ......................................................................................... 22
Notes .............................................................................................................................. 22

Thanks (acknowledgement)
Thank you for buying RaMaLoop device. We appreciate your confidence and
will be pleased if you will share with us your experience and observation during
RaMaLoop device usage.
www.Ramaloop.cz
Important instructions
ease, read this device manual carefully.
Never use the LightLoop antenna as a handle for manipulation with the
device. Magnetic holder has not been constructed to keep whole device
weight.
Do not use the device while driving a car.
RaMaLoop may affect the function of peacemakers and others implanted
devices – consult with your doctor about its use.
Do not use the device in airplane.
Do not use RaMaLoop near gas station, always turn it off near flamable
material.
Use only original batteries provided by manufacturer. There is a danger
of the device being destroyed or even an explosion.
Do not through of the battery in a fire or expose it to temperatures above
+ 60 ° C as there is a risk of explosion or fire.
Handle the device and accessories with care, protect it from falling,
mechanical damage, dirt and excessive temperatures. Never
disassemble it!
Do not expose this device to rain or moisture.

Introduction
RaMaLoop has been designed for contactless and convenient disposal of
microorganisms (viruses, fungi, bacteria).
RaMaLoop is a revolutionary innovative device that is freely usable as a
frequency generator. If necessary, it can be also connected to other frequency
generators. RaMaLoop significantly increasing the utility value of these devices
by expanding the possibility of contactless disposal of microorganisms (viruses,
fungi, bacteria) on the basis of the frequency method. RaMaLoop creates a
pulsed alternating magnetic field around its frame coil ("antenna") in the order of
several meters.
The frequency range of the RaMaLoop is from 1 Hz to 999 kHz.
Use of magnetic impulses
The magnetic field penetrates in all directions, even there where the impulse
direct current does not reach, for example in a non-conductive environment.
This opens wide scope for future use in many advanced industries like food,
agriculture. In case of medical certification can be used in low and high
frequency magneto-therapy or in veterinary practice.
It also has the potential to become an exciting tool for students interested in
science studies.

Package contents
RaMaLoop – 1pcs
LightLoop antenna – 1pcs
Cable RCA-RCA black/silver – 1pcs
Cable 3.5mm Jack-Jack black or silver – 1pcs
Cable USB A-microUSB B black – 1pcs
Power adapter 5V/1A with USB connector – 1pcs
Optional accessories
Power adapter 12V/2A with DC Jack 5.5/2.1mm connector
Application coil
Large frame antenna
Cable USB A-microUSB B with moving light

Examples of use of contactless disposal of
microorganisms
in fabrics (seat covers, car seats, carpets, clothing)
in public areas (schools, kindergartens, clinics)
in households with pets
in foods and other products where micro-organisms can be expected
in feed mixtures and in silage pits (selective disposal of fungi and toxins)
- using a larger antenna
in hives (bee mite, bee plague)
in building industry (wormwood, mushrooms and mold)
Warning: Some applications need to more test and respect the hygienic and
legal standards of the industry.
For these reasons mentioned above, the RaMaLoop has the potential to
become a laboratory aid in science and research.
Currently, RaMaLoop is most likely to appreciate existing owners of zapper and
F-Scan generators, who have only been till now able to use their device in a
contacting manner.
Our practical findings from the long-term testing of the first series indicate that
generating of alternate magnetic field has similar effect to that of the plasma
generator. The main effect and benefits of RaMaLoop, compared to the
conventional Zapper and F-Scan generators, is that the magnetic field
penetrates to a greater depth than where the impulse direct current can
penetrate.
On top of that, the influence of conductivity of the environment, such as the use
of metal or rubber electrodes, does not play a role here.

Commissioning
When the device is delivered by the manufacturer, it must be connected to the
power adapter or USB before use for the first time so that the device is
automatically turned on and ready for use.
Description of connectors connection
1. Power supply input – Adaptor (10 – 28V DC, 24W max., )
2. Power supply input – microUSB (5V DC, 2,5W max.)
3. Frame antenna output
4. Signal input 0-1MHz (recommended for Zapper)
5. Signal input 0-1MHz ( recommended for F-Scan) / Audio signal input 0-20kHz
Figure 1: Connectors connection.
1 2 3 4 5

Description of indicators on CD
1. ulse Output Indication - ulse flashing frequency is for illustration only,
it is used as an indication of active output.
2. Battery charge status indicator - With charge status in percent and
remaining time in minutes to discharge. Discharging time is not displayed
in case the device is powered from an external power source.
3. Output power indication.
4. Number of triggered generator (1-5), currently generated frequencies
and remaining calculated duration.
5. Remaining time to shut down, only displayed when the automatic
shutdown timer is active.
6. ower / charging indication from the power adapter.
7. ower / charging indication from USB.
Figure 2: Description of indicators on LCD.

Device menu description
1 Freq encies generator - Freq encies generator settings
1. rogram 1 – selection of preset program number 1.
1.1. Hz => kHz> - List of preset frequencies in Hz.
1.2. kHz => Hz> - List of preset frequencies in kHz.
2. Start - Initial Frequency of rogram nr. 1.
3. Start unit - The order of the set start frequency of program number 1 in
Hz or kHz.
4. Stop – the final frequency of the program 1, if it is identical with the first
frequency, a constant frequency will be generated.
5. Stop unit - The order of the set final frequency of program number 1 in
Hz or kHz.
6. Length - Duration of generating the set frequency of program number 1
or the time of tuning of the entire set frequency range.
7. Launch generator - Starts the program generator number 1 and then
continues to other programs (number 2,3,4,5) if they have set
frequencies.
8. rogram 2 - Selection of preset program number 2.
8.1. Hz => kHz> - List of preset frequencies in Hz.
8.2. kHz => Hz> - List of preset frequencies in kHz.
9. Start - Initial Frequency of rogram nr. 2.
10.Start unit - The order of the set start frequency of program number 2 in
Hz or kHz.
11.Stop – the final frequency of the program 2, if it is identical with the first
frequency, a constant frequency will be generated.
12.Stop unit - The order of the set final frequency of program number 2 in
Hz or kHz.
13.Duration – Duration of generating the set frequency of program number
2 or the time of tuning of the entire set frequency range.

14.Start generator – Starts the program generator number 2 and then
continues to other programs (number 3,4,5) if they have set frequencies.
15. rogram 3 - Selection of preset program number 3.
15.1. Hz => kHz> - List of preset frequencies in Hz.
15.2. kHz => Hz> - List of preset frequencies in kHz.
16.Start - Initial Frequency of rogram Number 3.
17.Start unit - The order of the set start frequency of program number 3 in
Hz or kHz.
18.Stop – the final frequency of the program 3, if it is identical with the first
frequency, a constant frequency will be generated.
19.Stop unit - The order of the set final frequency of program number 3 in
Hz or kHz.
20.Duration - Duration of generating the set frequency of program number 3
or the time of tuning of the entire set frequency range.
21.Start generator - Starts the program generator number 3 and then
continues to other programs (number 4,5) if they have set frequencies..
22. rogram 4 – selection of preset program number 4.
22.1. Hz => kHz> - List of preset frequencies in Hz.
22.2. kHz => Hz> - List of preset frequencies in kHz.
23.Start - Initial Frequency of rogram nr. 4.
24.Start unit - The order of the set start frequency of program number 4 in
Hz or kHz.
25.Stop – the final frequency of the program 4, if it is identical with the first
frequency, a constant frequency will be generated.
26.Stop unit - The order of the set final frequency of program number 4 in
Hz or kHz.
27.Duration - Duration of generating the set frequency of program number 4
or the time of tuning of the entire set frequency range.
28.Start generator - Starts the program generator number 4 and then
continues to other programs (number 5) if they have set frequencies.
29. rogram 5 – selection of preset program number 5.

29.1. Hz => kHz> - List of preset frequencies in Hz.
29.2. kHz => Hz> - List of preset frequencies in kHz.
30.Start - Initial Frequency of rogram nr. 5.
31.Start unit - The order of the set start frequency of program number 5 in
Hz or kHz.
32.Stop – the final frequency of the program 5, if it is identical with the first
frequency, a constant frequency will be generated.
33.Stop unit - The order of the set final frequency of program number 5 in
Hz or kHz.
34.Duration - Duration of generating the set frequency of program number 5
or the time of tuning of the entire set frequency range.
35.Start generator - Starts the program generator number 5 and then ends.
36.Direction - "Ascending" - Frequencies move from START to the
frequency set at STO , "Descending" - Frequencies are generated from
the upper frequency value set for "STO " to the lower frequency for
"START" (for all START and STO frequencies).
37.Repeat - if "YES" is selected, the programs are repeated over and over
again.
38.Sleep timer - timer setting for automatic shutdown. When setting 0h0min,
automatic shutdown is inactive.
39.Application Coil - activation of awakening for application coil. Do not turn
on this option unless you have a special application coil attached.
40. owerBoost - Activates higher performance, this option is forbidden to
use in EU territory due to regulatory standards.
41.Back - return to the previous menu without saving the parameters.
2 LightLoop - antenna lighting settings
1. Off - turns off the lights
2. RGB - Lighting with automatic light color change
1. Change speed - Speed of color change
2. Modulation - light flashes according to the output frequency (over
50Hz is permanently lit)

3. Back - Save the settings and return to the previous menu
3. Optional color - Lighting with user-adjustable light color
1. Red level - setting the intensity of the red color
2. Green level - setting the intensity of the green color
3. Blue level - setting the intensity of the blue color
4. Modulation - light flashes according to the output frequency (over
50Hz is permanently lit)
5. Back - Save the settings and return to the previous menu
4. Back - return to the previous menu
3 Lang age - User Interface Lang age selection
1. English
2. Cestina
3. Deutch
4. Espanol
5. olski
6. Back - return to the previous menu
4 Info - Listing of Diagnostic Data
1. SW version
2. Serial number
3. Charging cycles number
4. Battery condition
5. Battery temperature
6. Diagnostic information for service needs
5 Ret rn - ret rn from the men

Control description
Device is controlled by 5 buttons.
U
OK and
RIGHT
DOWN
LEFT
Buttons functions
Button functions differ according to the current LCD display.
1 Button function when displaying indicators on CD
U - increase output power.
DOWN - decrease output power.
LEFT - decrease LCD brightness.
RIGHT - Increase LCD brightness.
OK - displays the menu, while pressing OK for 5 seconds, the
machine is switched off / on.
LEFT + RIGHT - stop of the generating.
U + DOWN - ause of the generating.
DOWN + OK - when you press both buttons for 5 seconds, the
device will reset and restart (used in case of nonstandard behavior
or jamming).

2 Button function in menu
U - move up / increase the value of the selected item.
DOWN - Move down / decrease the value of the selected item.
LEFT - returns, returns to the previous menu / main view of the
indicators.
RIGHT - no function.
OK - confirms the current selection / switches between changing
the value of the item and selecting it.

Basic controls
In the main view (the LCD shows the indicators), the power setting device
can be adjusted in five steps using the up / down arrows and seven-level
LCD brightness control, using the left / right arrows. At the lowest level,
only a dash appears in the display, the individual indicators are gradually
displayed up to full brightness. At the very highest level, the frame itself
(Lightloop) lights up if it is set in the menu.
When you press the OK buttons in the main view, the Configuration menu
appears. Here you can set the frequency generator, LightLoop, language
and display service device information.
The device has an auto-off function. If it is not operated by the keypad,
generating is not running, or if there is no signal from the external
generator, it is automatically switched off after 15 minutes.
If you need to reset the factory settings or if the device is behaving
contrary to the instructions, you can reset it by holding the OK + Down
arrow buttons until the RaMaLoop logo appears on the display.
ight oop settings
LighLoop has three basic settings: Off, RGB, and Optional Color.
The "Off" setting switches off the lights.
The "RGB" setting starts the automatic color change. The rate of change can be
set using the "Change Speed" item in the RGB setting. The "Modulation" option
allows you to set the flashing of the illumination in the rhythm of the input
pulses, the blinking is only visible up to 50Hz, it is permanently lit at higher
frequencies.
The "Optional Color" setting starts the user-adjustable color illumination. The
resulting color is given by "Red Level", "Green Level", and "Blue Level".
Setting the LighLoop antenna lighting has no effect on electromagnetic field
generating. When the generator is switched on or an external generator is
connected, the electromagnetic field is emitted by the antenna without being
switched on or off by LighLoop lighting.

Frequency generator settings
RaMaLoop includes a frequency generator function that allows you to generate
frequencies in the range 0 - 5kHz, higher frequencies are generated as higher
harmonics of this range. At the same time, this menu also contains a timer to
turn off the device after the selected time.
After activating the generator or the shutdown timer, the time and frequency
information are displayed continuously on the main screen. The remaining time
information is updated whenever the displayed frequency is updated, not every
second. Frequencies up to 1000Hz are displayed in Hz, higher frequencies are
displayed in kHz, rounding of higher frequencies is only for imaging, generating
takes place in 1Hz.
You can set up successively up to 5 consecutive programs. Individual programs
allow you to select from preset frequencies in the order of Hz and kHz. For each
selected program, you can manually adjust the desired initial / final frequency
with the START and STO values, where START is the initial frequency and the
STO is the final frequency. If the values are the same it is so-called fixed
frequency. Each program also allows you to set the duration.
In addition, the generator allows you to change the direction of startup of the set
programs, turn them on again and set the time for automatic shutdown of the
device.
The preset programs are selected by pressing the OK button on " rogram 1"
and gradually down to " rogram 5". Use the U , DOWN, and RIGHT arrows to
select the desired program and confirm with OK. If you have multiple programs
set up, they will automatically start running consecutively from the program that
was first.
1 How to run one program:
1. Enter the "Generator Frequency"
2. Select " rogram 1", press OK and select the desired program, the other
items " rogram 2-5" set the same way to program number 0
3. If no program meets your requirements, set the desired initial and final
frequency manually using the "Start" and "Stop"
4. Set "Unit start" and "Unit stop" to order, Hz, or kHz, according to your
request for initial and final frequency.
5. Set the length of the program using "Length".

6. Set the frequency generation direction (descending or ascending)
7. Set the repeat or shutdown timer to suit your needs.
8. Start the generator by confirming "Spust generator" on the same screen
as " rogram 1"
2 How to run 5 programs:
1. Enter the "Generator Frequency"
2. Select " rogram 1" and select the desired program.
3. If no program meets your requirements, set the desired initial and final
frequency manually using the "Start" and "Stop"
4. Set "Unit start" and "Unit stop" to order, Hz, or kHz, according to your
request for initial and final frequency.
5. Set the length of the program using "Length".
6. Repeat steps 2 through 5 for other programs.
7. Set the frequency generation direction (descending or ascending)
8. Set the repeat or shutdown timer to suit your needs.
9. Start the generator by confirming "Spust generator" on the same screen
as " rogram 1"
3 Generator settings for use with application coil
The application coil is a coil designed to apply a locally homogeneous magnetic
field for stimulation. This is not the standard antenna supplied with the device.
For more information on this accessory, please contact your distributor.
Activating of the generator for the application coil is to switch the "Application
Cylinder" item in the frequency generator menu to YES. Do not turn this option
on if you are not using the application coil.
For application coil, the frequencies are primarily 0 - 100Hz.
anguage setting
The "Language" item in the configuration menu allows you to select the
language of the labels in the main view and menu items.

Service information
Item "Info" allows you to view service information about the device: program
version, serial number, number of battery charging cycles, battery status /
condition, battery temperature and other service information.
Charging
You can use any microUSB charger (5V and at least 0.5A) to charge, or you can
use a second input for a standard adapter with a DC jack 5.5 / 2.1mm (12-28V
and at least 1.5A) to charge.
When the adapter is connected, the device is identified and, if it meets the
requirements, charging is started and the charging indicator appears on the
display. Once the charging is complete, the indicator disappears and the device
goes into power mode from the adapter.
Recharging the battery is triggered when the charge level falls below 90%. For
example, when the battery is fully discharged after 95%, it cannot be charged
again at 100%. This feature prevents frequent cycling of the battery and thus
significantly increases its service life.

Technical specifications
ower supply
Supply voltage – microUSB 5 V DC
Supply voltage – Adaptér 10-28 V DC
Supply power - microUSB 2.5W
Supply power - Adaptér 24W
Compatible battery A606164 2500mAh/3.6V
L 655165 2400mAh/3.7V
L 654365 2300mAh/3.7V
General
Device type ortable enclosure with
removable frame antenna
Dimensions without antenna 12 x 8 x 3 cm
Dimensions with antenna 25 x 8 x 20 cm
Weight 400g
Operation temperature 0 – 40 ºC
Maximal operation humidity 90% non-condensating
Length of any connected cable is not
larger than 3m.
Input signals
Digital input (Cinch/Jack tip) 4 – 15V DC
Audio input (Jack ring) 150mV (4Hz - 20kHz)
Table of contents
Popular Medical Equipment manuals by other brands

Getinge
Getinge Arjohuntleigh Nimbus 3 Professional Instructions for use

Mettler Electronics
Mettler Electronics Sonicator 730 Maintenance manual

Pressalit Care
Pressalit Care R1100 Mounting instruction

Denas MS
Denas MS DENAS-T operating manual

bort medical
bort medical ActiveColor quick guide

AccuVein
AccuVein AV400 user manual