Electric Hi Lo Screen lift 750 - Trolley Mount 8960
- Max Capacity 100kg - Min Capacity 5kg - Screens upto 86”
Safety instructions
Use the following safety guidelines to help protect your lift from potential damage and to
ensure your own personal safety.
Read all the installation instructions before testing or installing your lift.
Read and follow all safety instructions.
Keep the optional remote control out of reach of children.
To prevent bodily injury, keep hands and clothing away from the lift while the lift is in
operation.
Before installing the lift or working with its connections, unplug the lift from the mains
power supply socket
Do not place the lift in places subject to extreme temperatures for example near a
radiator, or heating vent.
The Electric lift must only be mounted in a dry area and it must ensured before use that
the lift is safe or protected from liquid contact or spillage.
Unplug the lift IMMEDIATELY in the following conditions:
-When the power cord or plug is damaged or frayed.
-If liquid has spilled into the lift.
-If the lift has been exposed to rain or water.
-If the lift exhibits a distinct change in performance, indicating a need for
servicing.
MANUFACTURERS who build this Lift into other products or use it with other products,
MUST make sure to prevent bodily injury. The MANUFACTURER is responsible to give
the end user proper warnings and instructions for use.
When adding a TV or any other equipment the party adding this TV or equipment is
responsible for stability and security
The lift should only be used on a flat floor area
PAT Test Class 2 Equipment
WARNING ! THIS IS NOT A TOY !
WARNING ! CHILDREN SHOULD NOT OPERATE LIFT OR HAVE ACCESS TO THE
OPTIONAL REMOTE CONTROL !
WARNING ! THE LIFT MUST BE IN THE LOWEST POSITION WHEN MOVING IT
AROUND!

Loxit Limited, First Avenue, Poynton Industrial Estate, Poynton, Cheshire, UK. SK12 1YJ
www.loxit.com ꞁ [email protected]om ꞁ +44(0)1625 856 801
Materials and weight:
Steel, black power coated- Weight 48kg (approx)
Min load:
5kg central loading
Max load:
100kg central loading
Operation:
Rocker switch or optional remote
Voltage consumption:
110-240VAC/ 50-60HZ
80 watt max (at 100kg)
Standby ‹1 watt
750mm Height adjustment.
Specifications and dimensions
PLEASE ENSURE THE SCREEN IS MOUNTED BEFORE ATTEMPTING TO OPERATE THE
LIFT. IT IS DESIGNED TO BE OPERATED ONLY WITH WEIGHT ATTACHED.

Loxit Limited, First Avenue, Poynton Industrial Estate, Poynton, Cheshire, UK. SK12 1YJ
www.loxit.com ꞁ [email protected]om ꞁ +44(0)1625 856 801
1. Remove the back panel as shown.
2. Remove protective tape from shafts and micro switches on the columns and motor
box. Then slide the column shafts into the sockets in the motor box. Do this for
both columns.
3. Gently remove the transportation brackets from columns as shown, put the
bolts removed to aside for use later in the assembly process.
*If the shafts will not fit into the sockets
in the motor box it may be necessary to
remove the brackets as shown in step 3.
The shaft can then be rotated to engage
in the socket.

Loxit Limited, First Avenue, Poynton Industrial Estate, Poynton, Cheshire, UK. SK12 1YJ
www.loxit.com ꞁ [email protected]om ꞁ +44(0)1625 856 801
4. Using two M6 bolts to secure each column in place.
5. Plug the power cable into the transformer though the grommet indicated
and bolt the rear panel in place.
6. Attach the handle using the bolts you put aside in step 3 and the bolts already
fitted in column. Use the top set of holes. Add the 16 caps into the holes indicated
by the red arrows.

Loxit Limited, First Avenue, Poynton Industrial Estate, Poynton, Cheshire, UK. SK12 1YJ
www.loxit.com ꞁ [email protected]om ꞁ +44(0)1625 856 801
7. Bolt the base and casters in place using the M10 bolts and washers.
8. Use four M6 bolts to bolt the mount plate to the trolley.
9. Attach the hangers to the back of the screen, make sure the hangers are
as central as possible.

Loxit Limited, First Avenue, Poynton Industrial Estate, Poynton, Cheshire, UK. SK12 1YJ
www.loxit.com ꞁ [email protected]om ꞁ +44(0)1625 856 801
10. Make sure the casters on the base are locked,
then hook the screen onto the mount plate.
11. Secure the screen in place using the two clips and
two M6*50mm bolts with washers.
12. Use the switch indicated to raise and lower the screen when the power has
been connected, please read all the safety information and warnings before
operation. Check that there is sufficient clearance under the screen when in its
fully lowered position that a trap is not formed.

Loxit Limited, First Avenue, Poynton Industrial Estate, Poynton, Cheshire, UK. SK12 1YJ
www.loxit.com ꞁ [email protected]om ꞁ +44(0)1625 856 801
The Hi-Lo 750 trolley is an electrically powered height adjustable trolley for the mounting of
large format and touchscreen displays.
WARNING
The product is shipped fully assembled on a custom pallet to prevent movement during
transport. If the unit is being stored do not double stack. To unpack remove the banding and lift
the outer carton off the unit.
Release the inner banding, release the castor brakes. The unit is stable. Carefully manoeuver
the unit off the pallet. This is a two person operation. Retain all packaging until the unit has
been inspected for damage.
When moving the unit the screen must be lowered to its lowest position. Ensure that all
castors are released from their brakes and are running freely. This unit is not designed for
rough terrain. Please treat sympathetically avoiding kerbs or changes in level and being
especially careful when changing floor surfaces or crossing sloping areas. Take your time. If in
doubt ask a second person to assist you.
Maintenance Instructions
There are no user maintenance or adjustment points on this machine. Simply clean dust and
dirt from the outside of the unit and inspect for damage or breaks. Cleaners and disinfectants
must not be highly alkaline or acidic.
The user should visually check the equipment for signs of wear or misuse before each time of
using and for the security of the screen or any accessories. The condition of electrical cables
and plugs should be checked for wear or abrasion before use.
In addition, the equipment should be visually inspected in more detail every three months to
ensure that the unit is functioning properly and if it is not the user should report this to the
manufacturer for advice or for the return of the unit to base for repair.
Incidences of misuse must be reported immediately and the unit placed out of commission.
All repairs to the unit must only be carried out in Loxit’s workshops as special tools must be
used.
The warranty is only valid in so far as the equipment has been used and maintained correctly
and has not been tampered with.
Violent treatment will invalidate the warranty.
During operation if the unit makes any unusual noises or smells turn off the power supply at
the mains immediately.

Loxit Limited, First Avenue, Poynton Industrial Estate, Poynton, Cheshire, UK. SK12 1YJ
www.loxit.com ꞁ [email protected]om ꞁ +44(0)1625 856 801
Continuous use maximum period 2 minutes. Maximum use 10% (6 minutes in any hour).
Ambient temperature range +5deg C to +40 deg C.
The noise produced by the unit when static is silent which represents 99% of the time in use.
The noise produced by the unit when moving is consistent with other office equipment and
would by comparison be rated as low.
Screen Lift Kit Contents
Bracket Pack Contents (may already be installed)
Kit
Quantity
Instructions
1
Cable tie
3
5mm Allen Key
1
4mm Allen key
1
3mm Allen key
1
Security Allen key
1
M8*20mm button head
4
M8*40mm button head
4
M6*16mm button head
4
M6*25mm button head
4
M6 Washer
4
M8 Washer
4
M6*12mm button head (may already be
installed)
4
White caps/buttons
16
Kit
Quantity
Mount plate
1
Screen hangers
2
Security clips
2
M6*50 button head
2

Loxit Limited, First Avenue, Poynton Industrial Estate, Poynton, Cheshire, UK. SK12 1YJ
www.loxit.com ꞁ [email protected]om ꞁ +44(0)1625 856 801
Trouble shooting
If the electric lift will not operate up or down when pushing the manual rocker switch, please
complete the following checks in order to evaluate or solve the problem.
Check the AC mains supply
If the mains plug is fused check the fuse is ok. Check the wall socket is working by connecting
another appliance into the same socket to test that it works.
Check the AC mains transformer power supply
Disconnect from the AC mains socket and remove the back cover of the motor unit by removing
the small screws. Reconnect the AC mains and carefully look inside to see whether the red light
is showing on the power supply transformer.
If it is not then carefully unplug the connection between the transformer and AC mains cable.
Wait at least 10 seconds and then carefully reconnect the AC mains cable to the power supply
transformer, making sure you push the plug in firmly.
Check the remote receiver control box
With the back cover removed as above you will see that the manual rocker switch is connected
to this box. Check if there is a blue light showing on the box. If there is not then carefully
disconnect the manual rocker switch cable from the box and also disconnect the cable coming
from the mains transformer power supply. Then carefully reconnect both of these.
If the unit is still not working please report this to your dealer for advice.
If the electric lift will not operate down or is stopping intermittently when pushing the
manual rocker down switch, please complete the following checks in order to evaluate or
solve the problem.
Check the weight loading
Be sure that the weight of the mounted monitor/board or equipment is more than the
minimum 5 kilos but less than the maximum central loading of 100kg.
If it is more than 5kg but less than 25kg then add some pressure from your own body weight by
centrally pushing down on the lift motor unit housing while the ‘down’ rocker switch is
operated, if this works then run the lift up and down a few times with your hand pushing down
in the same way to add some extra weight.
If the lift is working with this extra weight then providing your added equipment is less than
25kg, slightly loosen all screws fixing the handle to the columns, then carefully retighten the
handle mounting screws as evenly as possible. Then repeat the first part again. The lift should
now operate without the need for you to apply extra downward pressure.
If your equipment is more than 25kg already on the lift or if after completing the above the lift
is still not operating correctly then contact your dealer for advice

Loxit Limited, First Avenue, Poynton Industrial Estate, Poynton, Cheshire, UK. SK12 1YJ
www.loxit.com ꞁ [email protected]om ꞁ +44(0)1625 856 801
Declaration of Conformity
The following product has been tested with the listed standards and found in compliance with the Council
Directives detailed below.
Manufacturer:
Loxit Limited. First Avenue, Poynton Industrial Estate, Poynton, Cheshire, SK12 1YJ, England.
Type of Equipment:
Description: TV Wall Lift
Trademark: Loxit
Model Name: Screen Lift 750 Trolley Mount
Model Number: 8960
Technical Data: Input 230V, 50Hz, 80 watts
Test Standards: Complies with the following standards and other normative documents:
2006/42/EC
The Machinery Directive
2006/95/EC
Low Voltage Directive (LVD) relating to electrical equipment designed for use within certain voltage limits
(codified version) according to the standard EN 60335-1:2006
2004/108/EC according to the standards EN 55014-1:2007, EN 55014-2:1997, EN 61000-3-2:2006,
EN 61000-3-3:2008
EMC Directive
After preparation of the necessary technical documentation as well as the conformity declaration the CE
marking as shown below can be affixed on the equipment and/or included in relevant documentation.
This declaration is issued under the sole responsibility of Loxit Ltd.
Table of contents
Other Loxit Rack & Stand manuals

Loxit
Loxit 8262 User manual

Loxit
Loxit WF750 User manual

Loxit
Loxit 8990 User manual

Loxit
Loxit 8996 User manual

Loxit
Loxit 500 Flip Top 8514 Hi-Lo User manual

Loxit
Loxit 8509 User manual

Loxit
Loxit Hi Lo Mono 500 User manual

Loxit
Loxit 8510 User manual

Loxit
Loxit 8423 User manual

Loxit
Loxit Hi Lo Mono 600 User manual