For additional information, declaration of confirmity,
visit www.loxone.com/help/miniserver-go
About the product
The Miniserver Go is a device for the automatic control and
management of home automation and similar non safety
critical applications. The Loxone Miniserver Go has a fully
integrated Air Base Extension and is perfect for retrofitting
Loxone in existing homes.
Installation & electrical connection
If the unit is used in a non conform manner as specified by
the manufacturer the product included safeguards will be
impaired.
Information
Contains FCC ID: COR-ZWIR4512AC1
This device complies with part 15 of the FCC Rules. Operation
is subject to the following two conditions:
1. This device may not cause harmful interference
2. This device must accept any interference received,
including interference that may cause undesired operation
GND
Status
LED
Micro
SD
LAN
Connector
Power via
Micro USB
Link
Specifications
Miniserver Go
GND Link
24VDC
Power Supply
N L
Connect Extension
This folder is a part of the product!
Loxone Link Connection
Temperature resistance -40 … 105°C / -40 … 221°F
Wire cross-section 0.2 ... 1.5 mm² / AWG24 ... 16
Striping length 8mm / 0.31”
EXT
+ 24V
GND
BU
WH
Loxone
Link
Micro USB Connector
Connector type Micro USB 2.0 Type B
Keep in mind that GND
needs to be connected
to the ground of
the 24V Power.
Please use the 120 Ohm
resistor at the last Extension
which is connected to the