LOYTEC L-DALI User manual

L-DALI
DALI Light Controller
User Manual
LOYTEC electronics GmbH

Contact
LOYTEC
Blumengasse 35
A-1170 Vienna
AUSTRIA/EUROPE
http://www.loytec.com
Version 5.2
Document 88077110
LOYTEC MAKES AND YOU RECEIVE NO WARRANTIES OR CONDITIONS,
EXPRESS, IMPLIED, STATUTORY OR IN ANY COMMUNICATION WITH YOU,
AND
LOYTEC SPECIFICALLY DISCLAIMS ANY IMPLIED WARRANTY OF
MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. THIS
PRODUCT IS NOT DESIGNED OR INTENDED FOR USE IN EQUIPMENT
INTENDED FOR SURGICAL IMPLANT INTO THE BODY OR OTHER
APPLICATIONS INTENDED TO SUPPORT OR SUSTAIN LIFE, FOR USE IN
FLIGHT CONTROL OR ENGINE CONTROL EQUIPMENT WITHIN AN
AIRCRAFT, OR FOR ANY OTHER APPLICATION IN WHICH IN THE FAILURE
OF SUCH PRODUCT COULD CREATE A SITUATION IN WHICH PERSONAL
INJURY OR DEATH MAY OCCUR. LOYTEC MAKES NO REPRESENTATION
AND OFFERS NO WARRANTY OF ANY KIND REGARDING OF ANY
THIRDPARTY COMPONENTS MENTIONED IN THIS MANUAL.
No part of this publication may be reproduced, stored in a retrieval system, or transmitted,
in any form or by any means, electronic, mechanical, photocopying, recording, or otherwise,
without the prior written permission of LOYTEC.
LC3020, L-Chip, L-Core, L-DALI, L-GATE, L-INX, L-IOB,
LIOB-Connect, LIOB-FT, L-IP, LPA, L-Proxy, L-Switch, L-Term,
L-VIS, L-WEB, L-ZIBI, ORION™ stack and Smart Auto-Connect™ are
trademarks of LOYTEC electronics GmbH.
LonTalk®, LONWORKS®, Neuron®, LONMARK®, LonMaker®, i.LON®, and LNS®are
trademarks of Echelon Corporation registered in the United States and other countries.

L-DALI User’s Manual 3 LOYTEC
Version 5.2 LOYTEC electronics GmbH
Contents
1Introduction ................................................................................................15
1.1 Overview ............................................................................................................15
1.2 L-DALI Models .................................................................................................19
1.3 Scope...................................................................................................................19
2What’s New in L-DALI..............................................................................20
2.1 New in L-DALI 5.2............................................................................................20
2.2 New in L-DALI 3.2............................................................................................23
3Quick-Start Guide......................................................................................25
3.1 Hardware Installation.......................................................................................25
3.1.1 Models without built-in DALI Bus Power Supply...................................25
3.1.2 Models with built-in DALI Bus Power Supply........................................26
3.2 Device configuration .........................................................................................28
3.3 Configuration of IP Address ............................................................................28
3.3.1 IP Configuration via Console...................................................................28
3.3.2 IP Configuration via the Web Interface ...................................................29
3.3.3 IP Configuration via the LCD Display.....................................................31
3.4 Configuration with PC Software .....................................................................31
3.4.1 Connect to Device in Stand-Alone Mode.................................................32
3.4.2 Scan DALI Channel.................................................................................33
3.4.3 Assign Lamps, Sensor and Button to LONMARK/BACnet Objects..........34
3.4.4 Grouping Lamps ......................................................................................35
3.4.5 Parameterize the Constant Light Controller.............................................35
3.4.6 Parameterize the DALI button .................................................................36
3.4.7 Download Configuration..........................................................................36
3.4.8 Calibrate Light Sensor .............................................................................37
3.5 Configuration using Web Interface.................................................................38
3.5.1 Scan DALI Channel.................................................................................39
3.5.2 Assign Lamps, Sensor and Button to LONMARK/BACnet Objects..........40
3.5.3 Grouping Lamps ......................................................................................40
3.5.4 Calibrate Light Sensor .............................................................................41
3.5.5 Parameterize the DALI button .................................................................42
3.5.6 Parameterize the Constant Light Controller.............................................42
3.6 Configuration of BACnet Interface (LDALI-20X only) ................................43
3.6.1 Configure BACnet Interface ....................................................................43
4Hardware Installation................................................................................45

L-DALI User’s Manual 4 LOYTEC
Version 5.2 LOYTEC electronics GmbH
4.1 Enclosure........................................................................................................... 45
4.1.1 LDALI-3E10X and LDALI-ME204........................................................ 45
4.1.2 LDALI-E101-U, LDALI-3101-U and LDALI-E101-U........................... 45
4.2 Product Label.................................................................................................... 46
4.3 Mounting........................................................................................................... 46
4.4 LED signals ....................................................................................................... 47
4.4.1 LDALI-3E10X and LDALI-ME204........................................................ 47
4.4.2 LDALI-E101-U, LDALI-3101-U and LDALI-E101-U........................... 49
4.4.3 Wink Action ............................................................................................ 49
4.5 Buttons............................................................................................................... 49
4.5.1 Status Button ........................................................................................... 49
4.5.2 DALI Mode Button ................................................................................. 50
4.5.3 DALI Channel Button ............................................................................. 50
4.5.4 DALI Program Button............................................................................. 50
4.6 LCD Display and Jog Dial ............................................................................... 50
4.7 DIP Switch Settings .......................................................................................... 52
4.8 Terminal Layout and Power Supply............................................................... 52
4.8.1 LDALI-3E10X ........................................................................................ 53
4.8.2 LDALI-ME204........................................................................................ 53
4.8.3 LDALI-E101-U and LDALI-E201-U...................................................... 54
4.8.4 LDALI-3101-U........................................................................................ 54
4.9 Wiring................................................................................................................ 54
4.9.1 LDALI-ME20X....................................................................................... 54
4.9.2 LDALI-3E10X and LDALI-3101-U ....................................................... 55
5Web Interface .............................................................................................56
5.1 Device Information and Account Management ............................................. 56
5.2 Device Configuration........................................................................................ 58
5.2.1 Port Configuration................................................................................... 59
5.2.2 IP Configuration...................................................................................... 59
5.2.3 IP Host Configuration.............................................................................. 60
5.2.4 CEA-852 Device Configuration (LDALI-10X only)............................... 61
5.2.5 Global Connections Configuration.......................................................... 63
5.2.6 BACnet/IP Configuration (LDALI-20X only)......................................... 63
5.2.7 VNC Configuration ................................................................................. 64
5.2.8 CEA-709 Configuration (LDALI-10X only)........................................... 64
5.2.9 MS/TP Configuration (LDALI-ME204 only) ......................................... 65
5.2.10 E-Mail Configuration .............................................................................. 65
5.2.11 System Configuration.............................................................................. 66
5.2.12 BACnet Configuration (LDALI-20X only)............................................. 67

L-DALI User’s Manual 5 LOYTEC
Version 5.2 LOYTEC electronics GmbH
5.2.13 BACnet Recipients (LDALI-20X only)...................................................68
5.2.14 BACnet Time Master (LDALI-20X only) ...............................................68
5.2.15 BACnet Restart Notifications (LDALI-20X only)...................................69
5.2.16 BACnet ACL (Access Control List, LDALI-20X only)...........................69
5.2.17 Backup and Restore .................................................................................70
5.2.18 Debug.......................................................................................................71
5.2.19 Firmware..................................................................................................72
5.2.20 Documentation.........................................................................................73
5.3 Commission........................................................................................................73
5.3.1 BACnet (LDALI-20X only).....................................................................73
5.3.2 Constant Light Controller Bindings.........................................................74
5.3.3 DALI Groups...........................................................................................76
5.3.4 DALI Installation.....................................................................................76
5.3.5 DALI Scene .............................................................................................89
5.4 Data Management.............................................................................................90
5.4.1 Data Points...............................................................................................90
5.4.2 Trend........................................................................................................92
5.4.3 Scheduler .................................................................................................94
5.4.4 Calendar...................................................................................................96
5.4.5 Alarm.......................................................................................................97
5.5 Device Statistics.................................................................................................97
5.5.1 System Log ..............................................................................................97
5.5.2 BACnet Bindings Statistics (LDALI-20X only) ......................................98
5.5.3 BACnet MS/TP Statistics (LDALI-ME204 only)....................................98
5.5.4 CEA-709 Statistics (LDALI-10X only) .................................................100
5.5.5 CEA-852 Statistics.................................................................................101
5.5.6 Enhanced Communications Test............................................................102
5.5.7 Global Connections Statistics ................................................................103
5.5.8 OPC XML-DA Server Statistics Page....................................................104
5.5.9 IP Statistics ............................................................................................105
5.5.10 E-mail.....................................................................................................105
5.5.11 Packet Capture.......................................................................................106
5.5.12 DALI Statistics.......................................................................................106
5.5.13 Emergency Logs.....................................................................................107
5.5.14 Alarm Log Page.....................................................................................107
5.5.15 Scheduler Statistics Page .......................................................................108
5.6 Documentation.................................................................................................108
5.7 Reset, Contact, Logout....................................................................................109
6Concepts ....................................................................................................110

L-DALI User’s Manual 6 LOYTEC
Version 5.2 LOYTEC electronics GmbH
6.1 Data Points ...................................................................................................... 110
6.1.1 Overview............................................................................................... 110
6.1.2 Timing Parameters................................................................................. 111
6.1.3 Default Values....................................................................................... 111
6.1.4 Persistency............................................................................................. 111
6.1.5 Parameters............................................................................................. 112
6.1.6 Behavior on Value Changes .................................................................. 112
6.1.7 Custom Scaling...................................................................................... 113
6.1.8 Protected Data Points ............................................................................ 113
6.1.9 System Registers.................................................................................... 113
6.1.10 User Registers........................................................................................ 115
6.1.11 Structures............................................................................................... 115
6.1.12 Property Relations................................................................................. 116
6.1.13 Convertible Engineering Units .............................................................. 117
6.2 Math Objects................................................................................................... 118
6.2.1 General Properties................................................................................. 118
6.2.2 Usage Hints ........................................................................................... 118
6.2.3 Function List.......................................................................................... 119
6.3 Connections..................................................................................................... 121
6.3.1 Local Connections................................................................................. 121
6.3.2 Multi-Slot Connections.......................................................................... 122
6.3.3 Automatic Generation and Templates ................................................... 123
6.3.4 Global Connections ............................................................................... 124
6.4 AST Features................................................................................................... 125
6.4.1 Alarming................................................................................................ 125
6.4.2 Historical Alarm Log............................................................................. 126
6.4.3 Scheduling............................................................................................. 127
6.4.4 Trending................................................................................................ 129
6.4.5 E-mail.................................................................................................... 130
6.4.6 Historic Filters....................................................................................... 131
6.5 CEA-709 Technology...................................................................................... 132
6.5.1 Limitations for Local CEA-709 Schedulers........................................... 132
6.5.2 Limitations for CEA-709 Alarm Servers............................................... 132
6.5.3 Limitations for Local CEA-709 Trends................................................. 132
6.6 BACnet Technology........................................................................................ 133
6.6.1 BACnet Data Points .............................................................................. 133
6.6.2 BACnet Alarming.................................................................................. 133
6.6.3 BACnet Schedulers and Calendars........................................................ 134
6.6.4 BACnet Trend Logs .............................................................................. 134

L-DALI User’s Manual 7 LOYTEC
Version 5.2 LOYTEC electronics GmbH
6.6.5 Dynamic Polling in BACnet...................................................................135
6.6.6 BACnet Data Points in Connections......................................................135
6.7 Regular Expressions........................................................................................136
7The LINX Configurator...........................................................................139
7.1 Installation.......................................................................................................139
7.1.1 Software Installation ..............................................................................139
7.1.2 Registration as a Plug-In........................................................................139
7.1.3 Operating Modes....................................................................................141
7.2 Workflows for the L-DALI.............................................................................141
7.2.1 Involved Configuration Files .................................................................142
7.2.2 On-Line..................................................................................................142
7.2.3 Off-Line .................................................................................................143
7.2.4 Replace an L-DALI................................................................................144
7.3 CEA-709 Network Management/LNS Tools (LDALI-10X only) ................144
7.3.1 Adding an L-DALI.................................................................................144
7.3.2 Replacing an L-DALI ............................................................................147
7.3.3 Working with Configuration Properties.................................................150
7.3.4 Enable Legacy NM Mode......................................................................152
7.4 Using the LINX Configurator........................................................................152
7.4.1 Starting as an LNS Plug-In (LDALI-10X only).....................................152
7.4.2 Starting Stand-Alone..............................................................................153
7.4.3 Uploading the Configuration..................................................................154
7.4.4 Configuration Download........................................................................155
7.4.5 Upload the System Log..........................................................................158
7.4.6 Backup and Restore ...............................................................................159
7.5 DALI Installation ............................................................................................160
7.5.1 DALI Installation Tab............................................................................160
7.5.2 DALI Groups Tab..................................................................................163
7.5.3 DALI Channels Tab...............................................................................163
7.6 Parameter Configuration ...............................................................................164
7.6.1 Reset Run Hours and Energy Count.......................................................166
7.6.2 Calibrate Light Sensor ...........................................................................166
7.6.3 Calibrate Constant Light Controller.......................................................167
7.6.4 Modify Sunblind Controller Event Priorities .........................................168
7.6.5 Link Sunblind Controller to Constant Light Controller .........................169
7.6.6 Configure Emergency Light Auto-Test Calendar...................................169
7.7 Data Point Manager........................................................................................170
7.7.1 Folder List..............................................................................................170
7.7.2 Network Port Folders.............................................................................172

L-DALI User’s Manual 8 LOYTEC
Version 5.2 LOYTEC electronics GmbH
7.7.3 Data Point List....................................................................................... 172
7.7.4 Property View........................................................................................ 173
7.7.5 Tracking Data Point Usage.................................................................... 175
7.7.6 Managing Multistate Maps.................................................................... 176
7.7.7 Organizing Favorites ............................................................................. 177
7.7.8 Managing Property Relations ................................................................ 178
7.7.9 CEA-709 Properties .............................................................................. 178
7.7.10 BACnet Properties................................................................................. 179
7.7.11 User Registers........................................................................................ 180
7.7.12 Build XIF for CEA-709 Interface.......................................................... 181
7.8 BACnet Configuration (LDALI-20X only)................................................... 182
7.8.1 Scan for BACnet Objects ...................................................................... 182
7.8.2 Import from EDE File ........................................................................... 183
7.8.3 Use Imported BACnet Objects.............................................................. 184
7.8.4 Create a Client Mapping........................................................................ 184
7.8.5 Create Server Object ............................................................................. 185
7.8.6 Export Server Objects to an EDE File................................................... 186
7.8.7 Import Server Objects from an EDE File .............................................. 187
7.8.8 Map other Properties than Present_Value ............................................. 187
7.8.9 Enable International Character Support................................................. 188
7.8.10 Read the Active Priority........................................................................ 188
7.8.11 Write and Read with Priority................................................................. 189
7.8.12 Duplicate BACnet Devices with Data Points ........................................ 189
7.9 Connections..................................................................................................... 191
7.9.1 Create a New Connection...................................................................... 191
7.9.2 Create Connections from a CSV File .................................................... 194
7.9.3 Modify Connections.............................................................................. 194
7.9.4 Create a Multi-Slot Connection............................................................. 195
7.9.5 Create a Math Block Adaptor................................................................ 197
7.9.6 Connection Overview............................................................................ 198
7.9.7 Create a Global Connection................................................................... 199
7.9.8 Automatic Generation of Connections................................................... 200
7.9.9 Create an Auto-Generate Template ....................................................... 201
7.9.10 Create a Complex Auto-Generate Template.......................................... 202
7.9.11 Managing Connection Resources .......................................................... 204
7.10 E-mail Templates............................................................................................ 204
7.10.1 Create an E-mail Template.................................................................... 204
7.10.2 Trigger E-mails...................................................................................... 205
7.10.3 Attachments........................................................................................... 206

L-DALI User’s Manual 9 LOYTEC
Version 5.2 LOYTEC electronics GmbH
7.10.4 Limit E-mail Send Rate..........................................................................206
7.11 Local Schedule and Calendar.........................................................................207
7.11.1 Create Calendar Patterns........................................................................207
7.11.2 Create a Local Scheduler .......................................................................207
7.11.3 Configure Scheduled Data Points ..........................................................208
7.11.4 Configure Scheduled Events..................................................................209
7.11.5 Configure Exception Days.....................................................................211
7.11.6 Configure Control Data Points...............................................................212
7.11.7 Using the Local Scheduler .....................................................................213
7.12 Local Alarming................................................................................................213
7.12.1 Create an Alarm Server..........................................................................213
7.12.2 Create an Alarm Condition ....................................................................214
7.12.3 Deliver Alarms via E-mail .....................................................................216
7.12.4 Create an Alarm Log..............................................................................217
7.12.5 Multi-Edit Alarm Conditions .................................................................218
7.13 Local Trending ................................................................................................219
7.13.1 Create a Local Trend..............................................................................219
7.13.2 Configure Trended Data Points..............................................................220
7.13.3 Trend Triggers .......................................................................................221
7.13.4 Download Trend Data in CSV Format...................................................222
7.13.5 Deliver Trend Data via E-mail...............................................................222
7.13.6 Technology Trends ................................................................................223
7.14 Math Objects ...................................................................................................223
7.14.1 Create a Math Object.............................................................................223
7.14.2 Editing a Math Object............................................................................224
7.15 Historic Filters.................................................................................................225
7.15.1 Create Historic Filters............................................................................225
7.15.2 Managing Historic Filter Resources.......................................................226
7.16 Project Settings................................................................................................226
7.16.1 General...................................................................................................226
7.16.2 System Settings......................................................................................227
7.16.3 CEA-709 Settings (LDALI-10X only)...................................................228
7.16.4 CEA-709 AST Settings (LDALI-10X only) ..........................................229
7.16.5 BACnet Settings (LDALI-20X only).....................................................230
7.16.6 Project Information................................................................................232
8Operating Interfaces ................................................................................233
8.1 Common Interface...........................................................................................233
8.1.1 Schedule and Calendar XML Files ........................................................233
8.1.2 Trend Log CSV File...............................................................................233

L-DALI User’s Manual 10 LOYTEC
Version 5.2 LOYTEC electronics GmbH
8.1.3 Alarm Log CSV File.............................................................................. 235
8.1.4 Emergency Light Test Log CSV File .................................................... 235
8.2 CEA-709 Interface (LDALI-10X only) ......................................................... 235
8.2.1 Node Object #0000 ............................................................................... 236
8.2.2 Real-Time Keeper Object #3300........................................................... 236
8.2.3 Calendar Object #0006.......................................................................... 236
8.2.4 Scheduler Object #0007 ........................................................................ 237
8.2.5 Lamp actuator Object #3040 ................................................................. 237
8.2.6 Light Sensor Object #1010.................................................................... 258
8.2.7 Occupancy Sensor Object #1060........................................................... 260
8.2.8 Constant Light Controller Object #3050 ............................................... 262
8.2.9 Sunblind Controller Object #6111......................................................... 280
8.2.10 Globals #0005 ....................................................................................... 298
8.2.11 Button #0001......................................................................................... 305
8.3 BACnet Interface (LDALI-20X only) ........................................................... 307
8.3.1 Interface Version................................................................................... 308
8.3.2 Device Object........................................................................................ 308
8.3.3 Light Output Objects............................................................................. 314
8.3.4 Sensor Objects....................................................................................... 335
8.3.5 Constant Light Controller...................................................................... 339
8.3.6 Button Objects....................................................................................... 349
8.3.7 Alarming, Scheduling and Trending Objects (AST) ............................. 349
8.3.8 Client Mapping CSV File...................................................................... 349
8.3.9 EDE Export of BACnet Objects............................................................ 350
8.4 DALI Interface................................................................................................ 350
8.4.1 DALI Wiring......................................................................................... 351
8.4.2 DALI Channel Limitations.................................................................... 351
8.4.3 Multi-Master Operation......................................................................... 352
8.4.4 DALI Device Types .............................................................................. 352
8.4.5 Power Failure Recovery ........................................................................ 358
8.4.6 DALI Channel Bridging........................................................................ 358
8.4.7 Reducing ballast standby energy consumption...................................... 358
8.5 XML-DA OPC Server.................................................................................... 360
8.5.1 Access Methods..................................................................................... 360
8.5.2 Data Points ............................................................................................ 361
8.5.3 AST Objects.......................................................................................... 364
9Network Media.........................................................................................367
9.1 FT (LDALI-10X only) .................................................................................... 367
9.2 MS/TP (LDALI-ME204 only)........................................................................ 368

L-DALI User’s Manual 11 LOYTEC
Version 5.2 LOYTEC electronics GmbH
9.3 Redundant Ethernet (LDALI-E101-U/LDALI-E201-U only) .....................368
9.3.1 Ethernet Cabling Options.......................................................................368
9.3.2 Upstream Options ..................................................................................369
9.3.3 Preconditions .........................................................................................370
9.3.4 Switch Settings.......................................................................................370
9.3.5 Testing ...................................................................................................371
9.3.6 Example switch configuration................................................................372
10Firmware Update......................................................................................373
10.1 Firmware Update via the LINX Configurator (LDALI-10X only).............373
10.2 Firmware Update via the Web Interface.......................................................375
10.3 Firmware Update via FTP..............................................................................375
10.4 Firmware Update via the Console .................................................................376
11Troubleshooting........................................................................................378
11.1 Technical Support...........................................................................................378
11.2 Statistics on the Console .................................................................................379
11.2.1 Connecting to the Console .....................................................................379
11.2.2 Reset configuration (load factory defaults)............................................379
11.2.3 Device Statistics Menu...........................................................................379
11.3 DALI Troubleshooting....................................................................................381
11.4 DALI Error Codes ..........................................................................................382
11.5 DALI Protocol Analyzer.................................................................................382
11.5.1 Starting DALI PA via Console...............................................................382
11.5.2 Starting DALI PA via Telnet .................................................................383
11.5.3 DALI PA Information............................................................................383
11.6 Packet Capture................................................................................................384
11.6.1 Configure Remote Packet Capture.........................................................384
11.6.2 Run Wireshark Remote Capture ............................................................384
12Security Hardening Guide.......................................................................388
12.1 Installation Instructions..................................................................................388
12.2 Firmware..........................................................................................................388
12.3 Ports .................................................................................................................388
12.4 Services.............................................................................................................389
12.5 Logging and Auditing .....................................................................................389
13Specifications ............................................................................................390
13.1 Physical Specifications....................................................................................390
13.1.1 LDALI-3E10X/LDALI-ME204.............................................................390
13.1.2 LDALI-3101-U/LDALI-E101-U/LDALI-E201-U.................................390
13.2 Resource Limits...............................................................................................391
14References .................................................................................................392

L-DALI User Manual 13 LOYTEC
Version 5.2 LOYTEC electronics GmbH
Abbreviations
100BaseT ............................100 Mbps Ethernet network with RJ-45 plug
Aggregation.........................Collection of several CEA-709 packets into a single CEA-852
packet
AST.....................................Alarming, Scheduling, Trending
BACnet ...............................Building Automation and Control Network
BBMD.................................BACnet Broadcast Management Device
BDT ....................................Broadcast Distribution Table
CA.......................................Certification Authority
CC.......................................Configuration Client, also known as CN/IP Device
CEA-709.............................Protocol standard for LONWORKS networks
CEA-852.............................Protocol standard for tunneling CEA-709 packets over IP
channels
CN.......................................Control Network
CN/IP ..................................Control Network over IP
CN/IP Channel....................logical IP channels that tunnels CEA-709 packets according
CEA-852
CN/IP packet.......................IP packet that tunnels one or multiple CEA-709 packet(s)
COV....................................change-of-value
CR.......................................Channel Routing
CS........................................Configuration Server that manages CEA-852 IP devices
DA.......................................Data Access
DALI...................................Digital Addressable Lighting Interface, see IEC 62386
DHCP..................................Dynamic Host Configuration Protocol, RFC 2131, RFC 2132
DL.......................................Data Logger, Datenlogger (Webservice)
DNS ....................................Domain Name Server, RFC 1034
DST.....................................Daylight Saving Time
GMT....................................Greenwich Mean Time
IP.........................................Internet Protocol
LSD Tool ............................LOYTEC System Diagnostics Tool
IP-852..................................Logical IP-Channel, for tunneling CEA-709 packets according
to CEA-852
LAN ....................................Local Area Network
LSD Tool ............................LOYTEC System Diagnostics Tool
MAC ...................................Media Access Control
MD5....................................Message Digest 5, a secure hash function, see Internet RFC
1321
MS/TP.................................Master/Slave Token Passing (this is a BACnet data link layer)
NAT ....................................Network Address Translation, see Internet RFC 1631
NV.......................................Network Variable
OPC.....................................Open Process Control
OPC UA..............................OPC Unified Architecture
PEM ....................................Privacy Enhanced Mail
RNI......................................Remote Network Interface

L-DALI User Manual 14 LOYTEC
Version 5.2 LOYTEC electronics GmbH
RTT .................................... Round-Trip Time
RTU....................................Remote Terminal Unit
SL .......................................Send List
SMTP ................................. Simple Mail Transfer Protocol
SNTP..................................Simple Network Time Protocol
SNVT .................................Standard Network Variable Type
SSH.....................................Secure Shell
SSL.....................................Secure Socket Layer
TLS..................................... Transport Layer Security
UI........................................ User Interface
UNVT.................................User-Defined Network Variable Type
UTC....................................Universal Time Coordinated
WLAN................................ Wireless LAN
XML...................................eXtensible Markup Language

L-DALI User Manual 15 LOYTEC
Version 5.2 LOYTEC electronics GmbH
1 Introduction
1.1 Overview
The L-DALI controllers for LONMARK and BACnet systems are DALI gateways with built-
in light controller functionality.
DALI (Digital Addressable Lighting Interface) is defined in the international standard IEC
60929 Annex E and the newer IEC 62386. It is used to dim and switch luminaries from
most leading manufacturers. DALI also supports devices like multi-sensors (e.g. for
brightness, occupancy, etc.) and intelligent switches.
Figure 1: L-DALI supports up to four DALI channels.
The L-DALI lineup features 1, 2, or 4 independent DALI channels. Up to 64 DALI-based
luminaries per DALI channel can be controlled individually or via 16 groups. All luminaries
are monitored for lamp defect. L-DALI can provide this information to the Building
Management System (BMS) through its NV or BACnet interface respectively. For
CEA-709 communication IP-852 (Ethernet/IP) and TP/FT-10 are supported, for BACnet
communication BACnet/IP and BACnet MS/TP are supported.

L-DALI User Manual 16 LOYTEC
Version 5.2 LOYTEC electronics GmbH
LDALI-3101-U, LDALI-E101-U, LDALI-3E101, LDALI-3E102, and LDALI-3E104 are
gateways connecting a DALI network to a CEA-709 network, LDALI-ME204 and
LDALI-E201-U are gateways connecting a DALI network to a BACnet network. On the
DALI network the L-DALI controller represents a DALI master controller. On the
CEA-709 or BACnet network the L-DALI controller offers a NV interface or a BACnet
server objects respectively to control the ballasts and the sensors connected for the DALI
network.
The constant light controller (LONMARK functional profile #3050, BACnet Loop object)
allows controlling DALI ballasts with lighting nodes on the CEA-709 or BACnet network.
Occupancy and lux-level sensors for constant light control and buttons for manual operation
can be integrated via the CEA-709/BACnet interface or directly on the DALI side.
On the LONMARK version a built-in sunblind controller (LONMARK functional profile
#6111) interacts with other nodes on the CEA-709 network. Interaction between the
sunblind and constant light controller applications allows adjusting sunblinds depending on
the constant light controller output, e.g. for energy saving concepts.
L-DALI supports automation functions such as alarming, scheduling, and trending. The
L-DALI controllers offer local scheduling services including the possibility to configure
several local and remote 24 hour schedulers through the Web UI. Alarming includes the
functionality to generate, deliver, acknowledge, and display alarm conditions and logs
regardless whether the condition comes from the DALI or the CEA-709/BACnet network.
The trending capability includes periodic and event triggered data logging of values and
time stamps. Alarms and trend data are stored on the device accessible via an FTP
connection as CSV files.
Figure 2: Using L-DALI together with the L-WEB product family.
L-DALI devices can be integrated with LWEB-802/803 visualization and LWEB-900 using
OPC XML-DA. LWEB-802/803 and LWEB-900 can be used for visualization of an
L-DALI based lighting control system. LWEB-900 offers additional functionality like
saving trend and log files for long term storage, easy managing of remote schedulers and
calendars, data analysis and report generation. L-DALI supports event-driven e-mail
notification as a result of a predefined action triggered by a specific status or an exceeded
high limit. e-mail notification can also be used to forward trend and log files to central SQL
databases for long term storage (see LWEB-900 for details).

L-DALI User Manual 17 LOYTEC
Version 5.2 LOYTEC electronics GmbH
L-DALI supports common mathematical operations and functions, as well as Boolean
expressions.
Some lighting controller applications do not need a connection to the CEA-709 or BACnet
network. Therefore the L-DALI controller can control a DALI network as a standalone
device with the aid of the supported automation functions (alarming, scheduling, and
trending). Connected to an IP network, remote access allows to set parameters and to read
the system status.
The complete configuration can be done through the built-in Web server. The
commissioning and maintenance of the DALI system can be done using a standard Web
browser on a PC. The configuration can also be done via an PC based configuration
software (LONMARK/CEA-709 models only).
The L-DALI offers the following features:
DALI gateway and controller
Supports 1, 2, or 4 DALI channels (dependent on model)
Direct control of up to 64 DALI devices per DALI channel
Direct control of up to 16 DALI groups per DALI channel
Scene control for up to 16 groups and one broadcast scene per DALI channel
Detect lamp and ballast failure on DALI luminaries and signals
Simple replacement of (broken) DALI devices (no configuration tool required)
DALI Multi-Master capable
Support for DALI sensors and buttons
Built-in DALI protocol analyzer
Supports Alarming, Scheduling, and Trending (AST™)
Supports common mathematical operations and functions as well as Boolean
expressions
Supports event-driven e-mail notification
Supports periodic testing of emergency lights
Supports lamp burn-in mode
Support calculation of energy consumption and run-hours
OPC XML/DA (LWEB integration)
Configuration via Web interface
Firmware update via serial, CEA-709, or Ethernet port
Operating Voltage: 12-35 V DC or 12-24 V AC
157 x 86 x 60 (L x B x H in mm) or 9 TE

L-DALI User Manual 18 LOYTEC
Version 5.2 LOYTEC electronics GmbH
DIN rail mountable
LONMARK/CEA-709 models only:
Fully compliant with CEA-709, CEA-852, and EN 14908 standard
Supports LONMARK TP/FT-10 or CEA-852 Ethernet (IP-852) channels (selectable)
Control of DALI capable ballasts via NVs
Retrieve information from DALI capable sensors via NVs
Supports LONMARK Functional Profiles:
oLamp Actuator #3040
oLight Sensor #1010
oOccupancy Sensor #1060
oConstant Light Controller #3050
oSunblind Controller #6111
oScheduler #0007
oCalendar #0006
BACnet models only:
Fully compliant with BACnet standard ANSI/ASHRAE 135-2008
Supports BACnet/IP or BACnet MS/TP (selectable)
Control of DALI capable ballasts and sensors via BACnet server objects
Retrieve information from DALI capable sensors via BACnet server objects
BACnet client functionality (configurable)
Supports the following BACnet server objects:
oAnalog Output objects to control DALI ballasts, groups, and channels
oMulti-State Output objects for scene control of DALI groups and channels
oAnalog Input objects providing feedback from DALI ballast, groups, and
channels
oAnalog Input objects providing status information from DALI groups and
channels
oAccumulator objects providing estimated energy usage of DALI groups and
channels

L-DALI User Manual 19 LOYTEC
Version 5.2 LOYTEC electronics GmbH
oAnalog Input object providing lux level information from supported DALI
sensors
oBinary Input objects providing occupancy information from supported DALI
sensors
oLoop objects providing constant light controller functionality
1.2 L-DALI Models
This Section provides an overview of the different L-DALI models in Table 1. This table
identifies the different features of the L-DALI models. Models that possess a certain feature
have a check mark ()in the respective column. If a feature is not available in the particular
model, the column is left blank.
Model
Feature
3E101
3E102
3E104
3101-U
E101-U
ME204
E201-U
DALI Power Supply
DALI Channels
1
2
4
1
1
4
1
DALI Emergency Lights Test
Constant Light Controller
Sunblind Controller
Display with Jog Dial
LON TP/FT-10
LON IP-852 (Ethernet/IP)
BACnet MS/TP
BACnet/IP (Ethernet/IP)
Configuration via WEB UI
Configuration via Software
Console connector
Table 1: Available features in different L-DALI models.
Important: In the following text models with BACnet interface are referred to as LDALI-20X and
models with LONMARK/CEA-709 interface are referred to as LDALI-10X.
1.3 Scope
This document covers L-DALI devices with firmware version 5.2 and the L-INX
Configuration Software version 5.2.

L-DALI User Manual 20 LOYTEC
Version 5.2 LOYTEC electronics GmbH
2 What’s New in L-DALI
2.1 New in L-DALI 5.2
LINX Configurator replaces LDALI Configurator
The L-DALI models are now supported by the LINX Configurator PC software. The
LDALI Configurator software therefore is no longer available.
LINX Configurator support for LDALI-20X models
The LINX Configurator now supports LDALI-20X models, including DALI offline
configuration workflow and the configuration of alarming, scheduling and trend log objects,
e-mail templates, math objects, data point connections etc. Custom user registers and
BACnet objects can be created and data points belonging to the static L-DALI application
interface can be OPC exposed. Further, the BACnet network can be scanned and client
maps can be created from local BACnet objects to remote BACnet objects.
Support for LOYTEC LDALI-MS1, LDALI-BM1 and LDALI-RM1
The L-DALI now supports the LDALI-MS1 multi-sensor, the LDALI-BM1 push-button
coupler and the LDALI-RM1 relay module. These devices are an optimal addition to the
L-DALI controller and allow designing cost effective and flexible DALI lighting systems.
For more information on these devices see the corresponding datasheet and Section 8.4.4.
DALI Button Functions
For DALI button devices supporting configurable button functions these functions can be
configured using the Web-UI (online) and the LINX Configurator (online and offline). The
following functions are available to control DALI groups (see Section 5.3.4.7 and 7.6):
Dim up, dim down,
Off,
On with last dimming value,
Scene recall: 1–15,
Dim to a specified value in %,
Color temperature warmer/colder.
On LDALI-10X models the state of a button device input can be forwarded to a network
variable as an alternative to directly control DALI lights (see Section 8.2.11.1).
Table of contents
Other LOYTEC Controllers manuals
Popular Controllers manuals by other brands

Emerson
Emerson EIM E796 M2CP Installation and maintenance manual

Extron electronics
Extron electronics MLC 206 Backlight Replacement Guide

Copley Controls
Copley Controls Xenus XSL-230-36 Regeneration Guide

3Ware
3Ware 9590SE Series Quick install guide

Siemens
Siemens simatic ET 200MP manual

FASTRON.
FASTRON. Meridian MEC-110 operating instructions