Lucent Technologies SLC-2000 Access System Central Office... Troubleshooting guide

363-208-001
Issue 9
April 1998
SLC®-2000 Access System
User/Service Manual

Copyright © 1998 Lucent Technologies. All Rights Reserved.
This material is protected by the copyright and trade secret laws of the United States and other countries. It
may not be reproduced, distributed, or altered in any fashion by any entity, including other Lucent
Technologies Business Units orDivisions without the expressed written consent of the Customer Training and
Information Products Organization.
For permission to reproduce or distribute, please contact:
SLC®-2000 Access System Product Development Manager 1-888-LTINFO6
Notice
Every effort was made to ensure that the information in this document was complete and accurate at the time
of printing. However, the information, the products, and product availability are subject to change.
Mandatory Customer Information
Federal Communications Commission (FCC) Notification and Repair Information
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to
Part 15 of FCC Rules. These limits are designed to provide reasonable protection against harmful
interference when the equipment is operated in a commercial environment. This equipment generates, uses,
and can radiate radio frequency energy, and, if not installed and used in accordance with the instruction
manual, may cause harmful interference to radio communications. Operation of this equipment in a residence
is likely to cause harmful interference in which case the user will be required to correct the interference at his
own expense.
Security Statement
In rare instances, unauthorized individuals make connections to the telecommunications network through the
use of remote access features. In such event, applicable tariffs require that the customer pay all network
charges for traffic. Lucent Technologies cannot be responsible for such charges and will not make any
allowance or give any credit for charges that result from unauthorized access.
Trademarks
5ESS, BDJ, BDK, LGX, SLC, SPOTS, SPQ, and ST are registered trademarks of Lucent Technologies.
ACORN and Safari are registered trademarks of AT&T.
ANSI is a registered trademark of American National Standards Institute, Inc.
CLASS is a service mark of Bell Communications Research, Inc.
COMMON LANGUAGE is a registered trademark and CLEI, CLLI, CLCI, and CLFI are trademarks of Bell
Communications Research, Inc.
DANTEL is a registered trademark of Dantel, Inc.
DATAPATH is a trademark of CAE Industries Ltd.
DEC and VT100 are registered trademarks of Digital Equipment Corporation.
DMS-100 is a registered trademark of Northern Telecom, Ltd.
EWSD is a registered trademark of Siemens Aktiengesellschaft.
GTD-5 is a registered trademark of GTE Corporation.
HP is a registered trademark of Hewlett-Packard Company.
IBM and XT are registered trademarks of the International Business Machines Corporation.
MCU and PGM are registered trademarks of Tollgrade Communications, Inc.
MS-DOS is a registered trademark of Microsoft Corporation.
PROCOMM is a registered trademark of Datastorm Technologies, Inc.
Styrofoam is a registered trademark of The Dow Chemical Company.
TOSHIBA is a registered trademark of Toshiba Corporation.
UNIX is a registered trademark in the United States and other countries, licensed exclusively through X/Open
Company Limited.
Documentation Ordering Information
The ordering number for this document is 363-208-001. To order this document call the Lucent Technologies
Customer Information Center in Indianapolis, Indiana, on 1-888-LUCENT-8 (1-888-582-3688). RBOC/BOC
customers should process document orders or standing order requests through their Company
Documentation Coordinator. For more ordering information, refer to “How to Order Documents” in the chapter
“About This Document.”
Customer Assistance and Technical Support
Follow local procedures for obtaining technical assistance. Lucent Technologies also provides in-hours or
emergency out-of-hours help for the
SLC
®-2000 Access System. Call the Lucent Technologies Regional
Technical Assistance Center at 1-800-225-RTAC.
Developed by Lucent Technologies Network Systems Customer Training and Information Products.

How Are We Doing?
Title:
Identification No.: Issue No.: Date:
Lucent Technologies welcomes your feedback on this Customer Information Product (CIP). Your
comments can be of great value in helping us improve our CIPs.
1. Please rate the effectiveness of this CIP in the following areas:
2. Please check the ways you feel we could improve this CIP.
❒Improve the overview/introduction ❒Make it more concise/brief
❒Improve the table of contents ❒Add more step-by-step procedures/tutorials
❒Improve the organization ❒Add more troubleshooting information
❒Include more figures ❒Make it less technical
❒Add more examples ❒Add more/better quick reference aids
❒Add more detail ❒Improve the index
Please provide details for the suggested improvement.
3. What did you like most about this CIP?
4. Feel free to write any comments below or on an attached sheet.
If we may contact you concerning your comments, please complete the following:
Name: Telephone Number:
Company/Organization: Date:
Address:
When you have completed this form, please fold, tape and return to address on back
or Fax to: 910 727-3043.
Excellent Good Fair
Poor Not
Applicable
Ease of Use //////////////////
Clarity //////////////////
Completeness //////////////////
Accuracy //////////////////
Organization //////////////////
Appearance //////////////////
Examples
Illustrations
Overall Satisifaction //////////////////
SLC®-2000 Access System, User/Service Manual
363-208-001 9 April 1998

BUSINESS REPLY MAIL
FIRST CLASS PERMIT NO. 1999 GREENSBORO, NC
POSTAGE WILL BE PAID BY ADDRESSEE
NO POSTAGE
NECESSARY
IF MAILED
IN THE
UNITED STATES
-
--------------------------------------------------------------- Do Not Cut — Fold Here And Tape ------------------------------------------------------------------------
-
DOCUMENTATION SERVICES
2400 Reynolda Road
Winston-Salem, NC 27199-2029

How Are We Doing?
Title:
Identification No.: Issue No.: Date:
Lucent Technologies welcomes your feedback on this Customer Information Product (CIP). Your
comments can be of great value in helping us improve our CIPs.
1. Please rate the effectiveness of this CIP in the following areas:
2. Please check the ways you feel we could improve this CIP.
❒Improve the overview/introduction ❒Make it more concise/brief
❒Improve the table of contents ❒Add more step-by-step procedures/tutorials
❒Improve the organization ❒Add more troubleshooting information
❒Include more figures ❒Make it less technical
❒Add more examples ❒Add more/better quick reference aids
❒Add more detail ❒Improve the index
Please provide details for the suggested improvement.
3. What did you like most about this CIP?
4. Feel free to write any comments below or on an attached sheet.
If we may contact you concerning your comments, please complete the following:
Name: Telephone Number:
Company/Organization: Date:
Address:
When you have completed this form, please fold, tape and return to address on back
or Fax to: 910 727-3043.
Excellent Good Fair
Poor Not
Applicable
Ease of Use //////////////////
Clarity //////////////////
Completeness //////////////////
Accuracy //////////////////
Organization //////////////////
Appearance //////////////////
Examples
Illustrations
Overall Satisifaction //////////////////
SLC®-2000 Access System, User/Service Manual
363-208-001 9 April 1998

BUSINESS REPLY MAIL
FIRST CLASS PERMIT NO. 1999 GREENSBORO, NC
POSTAGE WILL BE PAID BY ADDRESSEE
NO POSTAGE
NECESSARY
IF MAILED
IN THE
UNITED STATES
-
--------------------------------------------------------------- Do Not Cut — Fold Here And Tape ------------------------------------------------------------------------
-
DOCUMENTATION SERVICES
2400 Reynolda Road
Winston-Salem, NC 27199-2029

Issue 9 April 1998 iii
Contents
About This Document xxi
■Purpose xxi
■Scope xxi
■Intended Audience xxii
■Reason for Reissue xxii
■How to Use This Document xxiii
■Conventions Used xxv
■Product Safety xxvi
■Customer Assistance and Technical Support xxix
■Related Documentation/Training xxx
■Electronic Documentation xxxviii
■How to Order Documents xxxviii
■How to Comment on This Document xxxix
1 System Overview 1-1
■Introduction 1-1
■
SLC
-2000 Access System Description 1-1
■Related Systems 1-9
2 Product Description 2-1
■Introduction 2-1
■Access Resource Manager (ARM) Shelf 2-3
■User Interface Panel (UIP) 2-26
■Alarm Test Unit (ATU) Panel (COT Only) 2-27
■MDS Assembly 2-28
■High Density Optics Shelf (HDOS) 2-43
■Fan Unit 2-45
■Software Release Compatibility and ARM Shelf
Common Unit Configurations 2-46

iv Issue 9 April 1998
Contents
■MDS Assembly Common/Channel Unit Configurations 2-53
■COT Cable Assemblies 2-53
■RT Cable Assemblies 2-53
3 Operations Interfaces 3-1
■Introduction 3-1
■Craft Interface Terminal (CIT) 3-2
■User Interface Panel (UIP) 3-3
■Equipment Indicators 3-8
■Office Alarms 3-9
■TL1/X.25 Interface 3-11
■Serial Telemetry Byte-Oriented Serial (TBOS) 3-12
■Parallel Telemetry 3-13
■Miscellaneous Discrete Environmental Alarms
and Controls (User-Definable) 3-16
■Other Alarms 3-21
■Order Wire 3-21
■Circuit Maintenance 3-22
4 Operations and Maintenance Procedures (TOP) 4-1
■Introduction 4-1
■How to Use Task-Oriented Practice (TOP) Procedures 4-4
■Safety Labels and Notes 4-6
■UIP and CIT Input Command Conventions 4-6
■Equipment and User Considerations 4-7
■Tools 4-8
■Cabling, Wiring, Assembly, and Application
Schematic Diagrams 4-9
■Turnup Philosophy 4-9
■Numerical List of TOP Procedures 4-16

Issue 9 April 1998 v
Contents
5 Administration and Provisioning 5-1
■Introduction 5-1
■Administration — SONET and Digital Loop Carrier
(DLC) Subsystems 5-2
■Administration — Multiplexing and Mapping 5-13
■Administration — Integral Test Head (ITH) 5-20
■Provisioning — SONET Subsystem 5-22
■Provisioning — DLC Subsystem 5-48
6 Plug-In Data Sheets 6-1
7 Software Release Descriptions 7-1
8 Technical Reference(s) 8-1
A Fiber Service Module (FSM) A-1
■Introduction A-1
■Functional Description A-2
■Physical Description A-6
■FSM Installation and Acceptance A-19
GL Glossary GL-1

Issue 9 April 1998 vii
Figures
About This Document
1. Static Control Wrist Strap xxviii
1 System Overview
1-1
SLC
®-2000 Access System Remote Terminal
Bays 1-6
1-2 The
SLC
-2000 Access System Equipped for
COT Applications 1-7
2 Product Description
2-1 Access Resource Manager (ARM) Shelf Slots 2-5
2-2 PDC Complex 2-6
2-3 SONET Feeder Section 2-8
2-4 DS1 Low-Speed Interface Section 2-18
2-5 DS1/VT Feeder Interface Section 2-20
2-6 Bandwidth Management Section 2-23
2-7 Integral Test Head Location 2-24
2-8 User Interface Panel (UIP) 2-26
2-9 Alarm Test Unit (ATU) Panel 2-27
2-10 MDS Assembly — Metallic Configuration 2-28
2-11 MDS Assembly — 12- and 24-Line FITL
Configuration (R4.0 to R4.4) 2-29
2-12 MDS Assembly — 12- and 24-Line FITL
Configuration (R4.5 or Later With
SPQ
810
Servers) 2-30
2-13 MDS Assembly — 12- and 24-Line FITL
Configuration (R4.5 or Later With
SPQ
811
Servers) 2-31
2-14 High Density Optics Shelf (HDOS) 2-44
2-15 Fan Unit 2-45
2-16 COT Bay Cable Assemblies 2-54

viii Issue 9 April 1998
Figures
2-17 RT/HDT Bay Cable Assembly — Bay Cables 2-55
2-18 RT/HDT Bay Cable Assembly — Standard
Shelf Danglers 2-56
2-19 RT/HDT Bay Cable Assembly — Optional
Shelf Danglers 2-57
2-20 RT/HDT Bay Cable Assembly — Backplane
or Intrashelf Connections 2-58
2-21 RT/HDT Bay Cable Assembly — Customer
Interface 2-59
2-22 MDS/DSX-1 Cabling Connections 2-60
2-23 DSX-1 Panel Cabling Connections 2-61
3 Operations Interfaces
3-1 User Interface Panel (UIP) — Maintenance
Section 3-3
3-2 User Interface Panel (UIP) — Display and
Control Section 3-5
3-3 Miscellaneous Discrete Environmental
Alarms and Controls (TBOS or TL1/X.25 at
Central Office) 3-18
3-4 Miscellaneous Discrete Environmental
Alarms and Controls (Parallel Telemetry at
Central Office) 3-19
5 Administration and Provisioning
5-1 Drop and Continue Nodes 5-38
A Fiber Service Module (FSM)
A-1 Block Diagram of the Fiber Service Module
(FSM) in a Typical HDT-to-MSDT
Arrangement A-4

Issue 9 April 1998 ix
Figures
A-2 Block Diagram of the Fiber Service Module
(FSM) in a Typical HDT-to-NBS
Arrangement A-5
A-3 FSM with Circuit Packs A-7
A-4 Recommended FSM Arrangement in the HDT A-9
A-5 FSM DSX-1 Wiring Diagram at HDT A-10
A-6 FSM Wiring Diagram at HDT A-11
A-7 FSM Equipment in the 841 MSDT Cabinet A-13
A-8 FSM Protectors, Wiring Blocks, and
Feeder/Distribution Panel in the 841 Cabinet A-14
A-9 841/MSDT/FSM Cabinet Wiring Diagram A-15
A-10 841/MSDT/FSM Repeater Shelf Assembly
Wiring Diagram A-16

Tables
Issue 9 April 1998 xi
1 System Overview
1-1 COT/RT DLC Software Release Compatibility 1-8
2 Product Description
2-1 Optical Line Interface (OLIU) Comparison 2-12
2-2
SLC
®-2000 Access System Channel Units 2-35
2-3
SLC
®-2000 Access System Software Package
Compatibilities 2-47
4 Operations and Maintenance Procedures (TOP)
4-1 DS1 Line Coding and Format 4-12
4-2 VTU/LIU Slot to MDS Standard DS1 System
Map (TR-08) 4-13
4-3 VTU/LIU and Corresponding INA System 4-14
4-4 Numerical List of TOP Procedures 4-14
5 Administration and Provisioning
5-1 SONET Subsystem In-Service Upgrade
Compatibility 5-6
5-2 DLC Subsystem Installation Times 5-9
5-3 Default DS1 to VT1.5 Mapping 5-16
5-4 SONET Subsystem OC-3 Default STS-1
Cross-Connections (Termination) 5-27
5-5 SONET Subsystem OC-3 Manual STS-1
Cross-Connections (Termination/Drop) 5-29
5-6 SONET Subsystem OC-3 Manual STS-1
Cross-Connections (Hub/Drop) 5-29
5-7 SONET Subsystem OC-3 Manual STS-1
Cross-Connections (Add) 5-29

Tables
xii Issue 9 April 1998
5-8 SONET Subsystem OC-3 Manual STS-1
Cross-Connections (Rings Pass Through) 5-29
5-9 SONET Subsystem OC-3 Manual STS-1
Cross-Connections (Rings Drop and Continue) 5-30
5-10 SONET Subsystem OC-3 Manual VT1.5
Cross-Connections (Termination/Drop) 5-30
5-11 SONET Subsystem OC-3 Manual VT1.5
Cross-Connections (Hub/Drop) 5-31
5-12 SONET Subsystem OC-3 Manual VT1.5
Cross-Connections (Add) 5-31
5-13 SONET Subsystem OC-3 Manual VT1.5
Cross-Connections (Pass Through) 5-31
5-14 SONET Subsystem OC-3 Manual VT1.5
Cross-Connections (Rings Drop and Continue) 5-32
5-15 Parameters Provisionable Using Hardware
Switches (SONET Software Release 7.X
and Earlier) 5-40
5-16 Parameters Provisionable Using Hardware
Switches (SONET Software Release 9.0
and Later) 5-41
5-17 SONET Subsystem Parameters Provisioned
Using the CIT 5-42
5-18 Performance-Monitoring Parameters
Provisionable Using the CIT 5-46
5-19 Parameters Provisionable Using the CIT (DLC
Subsystem) 5-50
5-20 EOC Provisionable Parameters (TR-303 VRT) 5-51
5-21 DS1 Framed Path Termination Parameters
(EOC Provisionable) 5-52
5-22 ISDN Framed Path Termination Parameters
(EOC Provisionable) 5-53
5-23 Channel Unit Options, Software Release, and
Provisioning Method 5-56
5-24 RT Channel Unit/MSDT Server Options
Provisionable Using Switches 5-59
5-25 R3.1 and R3.2 BRI Function Code Provisioning 5-62
5-26 R3.1 and R3.2 DFLT Function Code Provisioning 5-62
5-27 R3.1 and R3.2 DPO Function Code Provisioning 5-63
5-28 R3.1 and R3.2 DPT Function Code Provisioning 5-63

Tables
Issue 9 April 1998 xiii
5-29 R3.1 and R3.2 DS0A Function Code
Provisioning (AUA34) 5-64
5-30 R3.1 and R3.2 DS0A Function Code
Provisioning (AUA34B) 5-64
5-31 R3.1 and R3.2 DS0B Function Code
Provisioning (AUA34) 5-64
5-32 R3.1 and R3.2 DS0B Function Code
Provisioning (AUA34B) 5-65
5-33 R3.1 and R3.2 DX4 Function Code Provisioning 5-65
5-34 R3.1 and R3.2 EM4C/H Function Code
Provisioning 5-65
5-35 R3.1 and R3.2 ETO4 Function Code Provisioning 5-66
5-36 R3.1 and R3.2 FXO Function Code Provisioning 5-66
5-37 R3.1 and R3.2 FXO/P Function Code Provisioning 5-67
5-38 R3.1 and R3.2 FXS Function Code Provisioning 5-67
5-39 R3.1 and R3.2 FXS/T Function Code Provisioning 5-68
5-40 R3.1 and R3.2 OCU Function Code
Provisioning (AUA52) 5-68
5-41 R3.1 and R3.2 OCU Function Code
Provisioning (AUA52B) 5-69
5-42 R3.1 and R3.2 PLR1/2 Function Code
Provisioning 5-69
5-43 R3.1 and R3.2 TDO Function Code Provisioning 5-69
5-44 R3.1 and R3.2 TDS Function Code Provisioning 5-70
5-45 R3.1 and R3.2 TO Function Code Provisioning 5-70
5-46 R3.1 and R3.2 TO4 Function Code Provisioning 5-70
5-47 R3.3 BRI Function Code Provisioning 5-71
5-48 R3.3 DFLT Function Code Provisioning 5-71
5-49 R3.3 DPO Function Code Provisioning 5-71
5-50 R3.3 DPT Function Code Provisioning 5-72
5-51 R3.3 DS0A Function Code Provisioning (AUA34) 5-72
5-52 R3.3 DS0A Function Code Provisioning
(AUA34B) 5-72
5-53 R3.3 DS0A Function Code Provisioning
(
SPQ
®334) 5-73
5-54 R3.3 DS0B Function Code Provisioning
(AUA34) 5-73

Tables
xiv Issue 9 April 1998
5-55 R3.3 DS0B Function Code Provisioning
(AUA34B) 5-74
5-56 R3.3 DS0B Function Code Provisioning
(
SPQ
334) 5-74
5-57 R3.3 DX4 Function Code Provisioning 5-75
5-58 R3.3 EBS Function Code Provisioning 5-75
5-59 R3.3 EM4C/H Function Code Provisioning 5-76
5-60 R3.3 ETO4 Function Code Provisioning 5-76
5-61 R3.3 FXO Function Code Provisioning 5-77
5-62 R3.3 FXO/P Function Code Provisioning 5-77
5-63 R3.3 FXS Function Code Provisioning 5-78
5-64 R3.3 FXS/T Function Code Provisioning 5-78
5-65 R3.3 OCU Function Code Provisioning (AUA52) 5-79
5-66 R3.3 OCU Function Code Provisioning (AUA52B) 5-79
5-67 R3.3 OCU Function Code Provisioning (
SPQ
452) 5-80
5-68 R3.3 PLR1/2 Function Code Provisioning
(
SPQ
454) 5-80
5-69 R3.3 SW56 Function Code Provisioning
(
SPQ
334) 5-80
5-70 R3.3 TDO Function Code Provisioning 5-81
5-71 R3.3 TDS Function Code Provisioning 5-81
5-72 R3.3 TO Function Code Provisioning 5-81
5-73 R3.3 TO4 Function Code Provisioning 5-82
5-74 R4.0 AC Function Code Provisioning 5-83
5-75 R4.0 BRI Function Code Provisioning 5-83
5-76 R4.0 DATA Function Code Provisioning 5-83
5-77 R4.0 DFLT Function Code Provisioning 5-84
5-78 R4.0 DPO Function Code Provisioning 5-84
5-79 R4.0 DPT Function Code Provisioning 5-84
5-80 R4.0 DX4 Function Code Provisioning 5-85
5-81 R4.0 EM4C/H Function Code Provisioning 5-85
5-82 R4.0 ETO4 Function Code Provisioning 5-86
5-83 R4.0 FXO Function Code Provisioning 5-86
5-84 R4.0 FXO/P Function Code Provisioning 5-87
5-85 R4.0 FXS Function Code Provisioning 5-87

Tables
Issue 9 April 1998 xv
5-86 R4.0 FXS/T Function Code Provisioning 5-88
5-87 R4.0 GO Function Code Provisioning 5-88
5-88 R4.0 GS Function Code Provisioning 5-88
5-89 R4.0 LO Function Code Provisioning 5-89
5-90 R4.0 LR Function Code Provisioning 5-89
5-91 R4.0 LS Function Code Provisioning 5-89
5-92 R4.0 NO Function Code Provisioning 5-89
5-93 R4.0 OCU Function Code Provisioning
(AUA52/AUA152) 5-90
5-94 R4.0 OCU Function Code Provisioning (AUA52B) 5-90
5-95 R4.0 PLR1/2 Function Code Provisioning 5-91
5-96 R4.0 RVT Function Code Provisioning 5-91
5-97 R4.0 TDO Function Code Provisioning 5-91
5-98 R4.0 TDS Function Code Provisioning 5-92
5-99 R4.0 TO Function Code Provisioning 5-92
5-100 R4.0 TO4 Function Code Provisioning 5-92
5-101 R4.2 AC Function Code Provisioning 5-93
5-102 R4.2 BRI Function Code Provisioning 5-93
5-103 R4.2 DATA Function Code Provisioning 5-93
5-104 R4.2 DFLT Function Code Provisioning 5-94
5-105 R4.2 DFLT Function Code Provisioning
(
SPQ
456) 5-94
5-106 R4.2 DPO Function Code Provisioning 5-94
5-107 R4.2 DPT Function Code Provisioning 5-95
5-108 R4.2 DX4 Function Code Provisioning 5-95
5-109 R4.2 EBS Function Code Provisioning 5-95
5-110 R4.2 EM4C/H Function Code Provisioning 5-96
5-111 R4.2 ETO4 Function Code Provisioning 5-96
5-112 R4.2 FXO Function Code Provisioning 5-97
5-113 R4.2 FXO/P Function Code Provisioning 5-97
5-114 R4.2 FXS Function Code Provisioning 5-98
5-115 R4.2 FXS/T Function Code Provisioning 5-98
5-116 R4.2 GO Function Code Provisioning 5-98
5-117 R4.2 GS Function Code Provisioning 5-99
5-118 R4.2 LO Function Code Provisioning 5-99

Tables
xvi Issue 9 April 1998
5-119 R4.2 LR Function Code Provisioning 5-99
5-120 R4.2 LS Function Code Provisioning 5-99
5-121 R4.2 NO Function Code Provisioning 5-100
5-122 R4.2 OCU Function Code Provisioning
(AUA52/AUA152) 5-100
5-123 R4.2 OCU Function Code Provisioning (AUA52B) 5-101
5-124 R4.2 OCU Function Code Provisioning (
SPQ
452) 5-101
5-125 R4.2 PG5, PG8, PG15, and PG20 Function
Code Provisioning 5-102
5-126 R4.2 PLR1/2 Function Code Provisioning 5-102
5-127 R4.2 RVT Function Code Provisioning
(AUA56 and AUA56B) 5-102
5-128 R4.2 RVT Function Code Provisioning (
SPQ
456) 5-102
5-129 R4.2 SW56 Function Code Provisioning 5-103
5-130 R4.2 TDO Function Code Provisioning 5-103
5-131 R4.2 TDS Function Code Provisioning 5-103
5-132 R4.2 TO Function Code Provisioning 5-104
5-133 R4.2 TO4 Function Code Provisioning 5-104
5-134 R4.4 AC Function Code Provisioning 5-105
5-135 R4.4 BRI Function Code Provisioning 5-105
5-136 R4.4 DATA Function Code Provisioning 5-105
5-137 R4.4 DFLT Function Code Provisioning 5-106
5-138 R4.4 DFLT Function Code Provisioning
(
SPQ
456) 5-106
5-139 R4.4 DPO Function Code Provisioning 5-106
5-140 R4.4 DPT Function Code Provisioning 5-107
5-141 R4.4 DX4 Function Code Provisioning 5-107
5-142 R4.4 EBS Function Code Provisioning 5-107
5-143 R4.4 EM4C/H Function Code Provisioning 5-108
5-144 R4.4 ETO4 Function Code Provisioning 5-108
5-145 R4.4 FXO Function Code Provisioning 5-109
5-146 R4.4 FXO/P Function Code Provisioning 5-109
5-147 R4.4 FXS Function Code Provisioning 5-110
5-148 R4.4 FXS/T Function Code Provisioning 5-110
5-149 R4.4 GO Function Code Provisioning 5-110

Tables
Issue 9 April 1998 xvii
5-150 R4.4 GS Function Code Provisioning 5-111
5-151 R4.4 LO Function Code Provisioning 5-111
5-152 R4.4 LR Function Code Provisioning 5-111
5-153 R4.4 LS Function Code Provisioning 5-111
5-154 R4.4 NO Function Code Provisioning 5-112
5-155 R4.4 OCU Function Code Provisioning
(AUA52/AUA152) 5-112
5-156 R4.4 OCU Function Code Provisioning (AUA52B) 5-113
5-157 R4.4 OCU Function Code Provisioning
(
SPQ
452) 5-113
5-158 R4.4 PG5, PG8, PG15, and PG20
Function Code Provisioning 5-114
5-159 R4.4 PLR1/2 Function Code Provisioning 5-114
5-160 R4.4 RVT Function Code Provisioning
(AUA56) 5-114
5-161 R4.4 RVT Function Code Provisioning
(
SPQ
456) 5-114
5-162 R4.4 SW56 Function Code Provisioning 5-115
5-163 R4.4 TDO Function Code Provisioning 5-115
5-164 R4.4 TDS Function Code Provisioning 5-115
5-165 R4.4 TO Function Code Provisioning 5-116
5-166 R4.4 TO4 Function Code Provisioning 5-116
5-167 R4.5 AC Function Code Provisioning 5-117
5-168 R4.5 BRI Function Code Provisioning 5-117
5-169 R4.5 DATA Function Code Provisioning 5-117
5-170 R4.5 DFLT Function Code Provisioning 5-118
5-171 R4.5 DFLT Function Code Provisioning
(
SPQ
456) 5-118
5-172 R4.5 DPO Function Code Provisioning 5-118
5-173 R4.5 DPT Function Code Provisioning 5-119
5-174 R4.5 DX4 Function Code Provisioning 5-119
5-175 R4.5 EBS Function Code Provisioning 5-119
5-176 R4.5 EM4C/H Function Code Provisioning 5-120
5-177 R4.5 ETO4 Function Code Provisioning 5-120
5-178 R4.5 FXO Function Code Provisioning 5-121
5-179 R4.5 FXO/P Function Code Provisioning 5-121
Other manuals for SLC-2000 Access System Central Office...
2
Table of contents
Other Lucent Technologies Wireless Access Point manuals

Lucent Technologies
Lucent Technologies AP-1 Instruction Manual

Lucent Technologies
Lucent Technologies AP-3 User manual

Lucent Technologies
Lucent Technologies WavePoint-II User manual

Lucent Technologies
Lucent Technologies Orinoco WavePOINT II User manual

Lucent Technologies
Lucent Technologies WaveACCESS NET MDR232 User manual