Lucent PacketStar PSAX User manual

Doc. No.: 255-700-714R11.0
PacketStar®
PSAX 1-Port Channelized OC-3/STM-1 CES
Module
User Guide
Model 23N13 (Single-Mode) and 23N12 (Multimode)
for the PacketStar®PSAX Multiservice Media Gateways
Issue 1, July 2005
System Software Release 11.0.0
Top of Guide

Copyright © 2005 by Lucent Technologies. All rights reserved.
For trademark, regulatory compliance, and related legal information, see
the "Legal Notices, Safety, and Regulatory Information" section.

PacketStar®PSAX 1-Port Channelized OC-3/STM-1 CES Module User Guide, Issue 1 Release 11.0.0
255-700-714R11.0 iii
Legal Notices, Safety, and Regulatory
Information
Copyright
Copyright © 2005 by Lucent Technologies. All rights reserved.
This material is protected by the copyright laws of the United States and
other countries. It may not be reproduced, distributed, or altered in any fash-
ion by any entity (either internal or external to Lucent Technologies), except
in accordance with applicable agreements, contracts or licensing, without the
express written consent of the originating organization and the business
management owner of the material.
Trademarks
PacketStar, Lucent, Lucent Technologies, and the Lucent Technologies logo are
registered trademarks of Lucent Technologies in the USA. Other product and
brand names mentioned in this guide are trademarks or registered trade-
marks of their respective owners. APX-8000,CellPipe, and ConnectStar are
trademarks; and 7R/E, ConnectReach, STINGER, PacketStar, Navis, Lucent,
Lucent Technologies, and the Lucent Technologies logo are registered trade-
marks of Lucent Technologies in the USA. Other product and brand names
mentioned in this guide are trademarks or registered trademarks of their
respective owners.
Notices
The information in this document is for informational use only, is subject to
change without notice, and should not be construed as a commitment by
Lucent Technologies, Inc. This document is without warranty of any kind,
either expressed or implied. Lucent Technologies, Inc. assumes no responsi-
bility for any errors, inaccuracies, or omissions. Neither is any liability
assumed for damages resulting from the use of the information or instruc-
tions contained herein. Lucent Technologies, Inc. is not responsible for any
damage or loss to your data or equipment resulting either directly or indi-
rectly from use of this document.
Warranty Information
Lucent Technologies provides a 90-day limited software warranty, and a one-
year limited hardware warranty on this product. Refer to the Software License
and Limited Warranty Agreement and the Lucent Technologies InterNetworking Sys-
tems Global Warranty that accompanied your package for more information.

Legal Notices, Safety, and Regulatory Information
Safety Information
iv 255-700-714R11.0
PacketStar®PSAX 1-Port Channelized OC-3/STM-1 CES Module User Guide, Issue 1 Release 11.0.0
Safety Information
When installing and operating the 1-Port Channelized OC-3/STM-1 CES, fol-
low the safety guidelines provided in the PacketStar®PSAX Multiservice Media
Gateway Safety Guidelines, which accompanies this product, to help prevent
serious personal injury and damage to the 1-Port Channelized OC-3/STM-1
CES. Please read all warnings and instructions supplied before beginning
installation or configuration of this module. In addition to the general safety
information provided, you should also refer to the appropriate PSAX installa-
tion guide for other important safety information and procedures.
When installing and operating the modules, follow the safety guidelines pro-
vided in the PacketStar®PSAX Multiservice Media Gateway Safety Guidelines,
which accompanies this product, to help prevent serious personal injury and
damage to the modules. Please read all warnings and instructions supplied
before beginning installation or configuration of this module.
Regulatory Standards Compliance
The following PacketStar PSAX systems are compliant with applicable safety
and EMC standards when configured with both the 23N12 (MM)/23N13
(SM) modules, respectively:
•PSAX 1000 system
•PSAX 1250 system
•PSAX 2300 system
•PSAX 4500 system
Refer to the PacketStar PSAX 1000, PSAX 1250, PSAX 2300, or PSAX 4500
installation guide for details on safety and EMC standards compliance.

255-700-714R11.0 v
PacketStar®PSAX 1-Port Channelized OC-3/STM-1 CES Module User Guide, Issue 1 Release 11.0.0
Table of Contents
Legal Notices, Safety, and Regulatory Information . . . . . . . . . . . . . . . . . . iii
Copyright . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . iii
Trademarks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . iii
Notices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . iii
Warranty Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . iii
Safety Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .iv
Regulatory Standards Compliance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . iv
List of Figures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ix
List of Tables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xi
1Getting Started . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1
Purpose of This Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-1
Audience for This Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-1
What You Should Know . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-1
Related Reading . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-2
Product Information Library . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-2
Printed Documents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-2
Other Publications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-2
About Lucent Technologies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-2
About the PacketStar PSAX Product Family . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-2
PSAX 1000 Multiservice Media Gateway. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-3
PSAX 1250 Multiservice Media Gateway. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-3
PSAX 2300 Multiservice Media Gateway. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-3
PSAX 4500 Multiservice Media Gateway. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-4
Document Conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-4
Text Types Used in This Document. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-4
Icons and Symbols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-5
Use of Command Description Tables. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-5
Use of Field Description Tables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-6
General Document Navigational Guidelines. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-6
Selecting Options, Fields, and Commands Using the Console Interface . . . . . . . . . . . .1-6
Help Information. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-8
1-8
.1-6
.1-6
.1-6
.1-5
.1-5
.1-4
.1-4
.1-4
.1-3
.1-3
.1-3
.1-2
.1-2
.1-2
.1-2
.1-2
.1-2
.1-1
.1-1
.1-1
1-1
xi
ix
iv
iv
iii
iii
iii
iii
iii

Table of Contents
vi 255-700-714R11.0
PacketStar®PSAX 1-Port Channelized OC-3/STM-1 CES Module User Guide, Issue 1 Release 11.0.0
Technical Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-9
Before You Begin. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-9
Comments on This Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-10
2Module Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-1
Overview of This Chapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1
Functional Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1
Software Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2
Automatic Protection Switching (APS) Feature. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-3
SPVC Prioritization Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-3
Module Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-3
Hardware Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-3
Optical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-4
Power Consumption and Memory Allocation Specificaions . . . . . . . . . . . . . . . . . . . . 2-5
Module Status Indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-5
3Configuring the OC-3 Mode Ports and Channels Using the Console . . . . .3-1
Overview of This Chapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-1
Preparatory Steps Before Configuring the Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-1
Setting Up the Working and Protection Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-1
Loopback Option. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-4
Obtaining General Module Data and Accessing Ports and Channels. . . . . . . . . . . . . . . . . 3-6
Configuring All Channels on an OC-3 Port . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-10
Accessing the Channelized OC3 STS1 Port Configuration Window . . . . . . . . . . . . . . . . 3-16
Configuring All Channels on a Virtual DS1 Port on the Channelized OC-3
CES Module (No Strapping) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-17
Configuring the Channelized OC-3 Virtual DS1 Channels . . . . . . . . . . . . . . . . . . . . . . . 3-22
Configuring One or More Channels On A Port (Strapping). . . . . . . . . . . . . . . . . . . . . . . 3-26
Configuring a Port with One or More Channels, (Accessing the Channelized OC-3
Virtual DS1 Channel Configuration Window) (Strapping) . . . . . . . . . . . . . . . . . . . . . . 3-27
Configuring the OC-3 Working and Standby Module Pair . . . . . . . . . . . . . . . . . . . . . . . 3-29
Configuring J1 Trace . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-35
Configuring J2 Trace . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-41
Saving the Equipment Configuration and Logging Off . . . . . . . . . . . . . . . . . . . . . . . . . . 3-48
Viewing the Channelized OC-3 Statistics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-50
Viewing the Port Statistics. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-50
Viewing the Channelized OC-3 Virtual DS1 Port Statistics . . . . . . . . . . . . . . . . . . . . 3-53
Viewing the Channelized OC-3 STS1 Port Statistics . . . . . . . . . . . . . . . . . . . . . . . . . 3-56
Provisioning Interfaces and Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-58
3-58
3-56
3-53
3-50
3-50
3-48
3-41
3-35
3-29
3-27
3-26
3-22
3-17
3-16
3-10
3-6
3-4
3-1
3-1
3-1
3-1
2-5
2-5
2-4
2-3
2-3
2-3
2-3
2-2
2-1
2-1
2-1
1-10
1-9
1-9

Table of Contents
255-700-714R11.0 vii
PacketStar®PSAX 1-Port Channelized OC-3/STM-1 CES Module User Guide, Issue 1 Release 11.0.0
4Configuring the STM-1 Mode Ports and Channels Using the Console . . . 4-1
Overview of This Chapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-1
Preparatory Steps Before Configuring the Module. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-1
Loopback Option . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-4
Obtaining General Module Data and Accessing Ports and Channels . . . . . . . . . . . . . . . . .4-6
Configuring All Channels on a Port (Channelization Disabled) . . . . . . . . . . . . . . . . . . . . .4-10
Configuring All Channels on a Port . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-16
Configuring All Virtual E1 Port and Channels on a Port . . . . . . . . . . . . . . . . . . . . . . . . . .4-18
Configuring All Virtual E1 Channels on a Port (Without Strapping) . . . . . . . . . . . . . . . . .4-23
Configuring a Virtual Port with One or More E1 Channels. . . . . . . . . . . . . . . . . . . . . . . .4-27
Strapping One or More Channels on A Virtual Port . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-32
Configuring the 1+1 Protection Parameters. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-35
Configuring J1 Trace . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-40
Configuring J2 Trace . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-46
Saving the Equipment Configuration and Logging Off. . . . . . . . . . . . . . . . . . . . . . . . . . .4-53
Viewing the Channelized STM-1 Statistics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-55
Viewing the Channelized STM-1 Port Statistics . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-55
Viewing the Channelized STM-1 AU-3 Port Statistics . . . . . . . . . . . . . . . . . . . . . . . .4-58
Viewing the Channelized STM-1 Virtual E1 Port Statistics . . . . . . . . . . . . . . . . . . . . .4-60
Provisioning Interfaces and Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-63
AReference Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-1
Overview of This Appendix . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-1
Avoiding Common Errors When Configuring Interfaces. . . . . . . . . . . . . . . . . . . . . . . . . . A-1
Optimizing SVC Call Performance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-1
Connection Type by Interface Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-2
Interface Type by I/O Module Type. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-3
Module Alarm Status Descriptions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-7
Minimum AAL2 Trunk Size Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-8
Standard AAL2 Calculation Example . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-8
Fax Relay Using AAL2 Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-9
ATM Service Categories in the PSAX System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-9
ATM Service Category Descriptions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-9
Priority of ATM Service Categories in the PSAX System . . . . . . . . . . . . . . . . . . . . . . A-10
ATM TS, UPC, and VI Configuration Compatibilities . . . . . . . . . . . . . . . . . . . . . . . . . . . A-11
BLaser Safety Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-1
Overview of this Appendix . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .B-1
General Laser Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .B-1
Lasers and Eye Damage. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .B-1
Classification of Lasers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .B-2
B-2
B-1
B-1
B-1
B-1
A-11
A-10
A-9
A-9
A-9
A-8
A-8
A-7
A-3
A-2
A-1
A-1
A-1
A-1
4-63
4-60
4-58
4-55
4-55
4-53
4-46
4-40
4-35
4-32
4-27
4-23
4-18
4-16
4-10
4-6
4-4
4-1
4-1
4-1

Table of Contents
viii 255-700-714R11.0
PacketStar®PSAX 1-Port Channelized OC-3/STM-1 CES Module User Guide, Issue 1 Release 11.0.0
Lightwave Safety Precautions for Optical Fiber Telecommunication Systems . . . . . . . . . . . B-2
Laser Safety Precautions for Enclosed Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-3
Laser Safety Precautions for Unenclosed Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-3
Module Transceiver Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-4
B-4
B-3
B-3
B-2

255-700-714R11.0 ix
PacketStar®PSAX 1-Port Channelized OC-3/STM-1 CES Module User Guide, Issue 1 Release 11.0.0
List of Figures
1-1 Field Description Table Example . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-6
1-2 Main Menu Help Window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-9
2-1 1-Port Channelized OC-3/STM-1 CES Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-2
3-1 Working and Protection Modules in a PSAX 1250 Chassis . . . . . . . . . . . . . . . . . . . . . . . . . . .3-2
3-2 Working and Protection Module Pairs in a PSAX 2300 Chassis . . . . . . . . . . . . . . . . . . . . . . . .3-3
3-3 Fiber Optic Links Between Working and Protection Modules on a PSAX 1250
and a PSAX 2300 Chassis . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-4
3-4 Loopback Configuration Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-5
3-5 Console Interface Main Menu (Equipment Configuration Selected) . . . . . . . . . . . . . . . . . . . . .3-6
3-6 Sample Equipment Configuration Window on a PSAX 4500 System (Page 1) . . . . . . . . . . . . .3-7
3-7 Sample Equipment Configuration Window on a PSAX 1000, PSAX 2300, or PSAX 4500
System (Page 2) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-7
3-8 Channelized OC-3 Port Configuration Window (Before Configuration) . . . . . . . . . . . . . . . . .3-11
3-9 Channelized OC-3 Port Configuration Window (After Configuration) . . . . . . . . . . . . . . . . . .3-12
3-10 Channelized OC-3 STS1 Port Configuration Window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-16
3-11 Channelized OC-3 Virtual DS1 Port Configuration Window . . . . . . . . . . . . . . . . . . . . . . . . .3-18
3-12 Channelized OC-3 Virtual DS1 Channel Configuration Window for Channelization
Disabled Default . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-24
3-13 Strapped Channels 1 Through 5 Displaying After Apply Configuration Command Has
Been Applied . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-28
3-14 Displays Strapping on the Channelized OC-3 Virtual DS1 DS0s Strap
Display Window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-28
3-15 Module Configured for 1+1 Protection (Working Module) . . . . . . . . . . . . . . . . . . . . . . . . . .3-31
3-16 Channelized OC-3 APS Configuration Window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-31
3-17 Channelized OC-3 SM STS-1 Port Configuration Window . . . . . . . . . . . . . . . . . . . . . . . . . . .3-40
3-18 Higher Order Path Trace - J1 Byte Configuration Window . . . . . . . . . . . . . . . . . . . . . . . . . . .3-40
3-19 Channelized OC-3 SM STS-1 Port Configuration Window . . . . . . . . . . . . . . . . . . . . . . . . . . .3-46
3-20 Channelized OC-3 SM Virtual Ds1 Port Configuration Window . . . . . . . . . . . . . . . . . . . . . . .3-46
3-21 Lower Order Path Trace - J2 Byte Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-47
3-22 Save Configuration [Modified] (Before Saving) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-49
3-23 Channelized OC-3 Port Statistics Window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-51
3-24 Channelized OC-3 STS1 Port Configuration Window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-54
3-25 Channelized OC-3 STS1 Port Statistics Window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-57
4-1 Working and Protection Modules in a PSAX 1250 Chassis . . . . . . . . . . . . . . . . . . . . . . . . . . .4-2
4-2 Working and Protection Module Pairs in a PSAX 2300 Chassis . . . . . . . . . . . . . . . . . . . . . . . .4-3
4-3 Fiber Optic Links Between Working and Protection Modules on a PSAX 1250
and a PSAX 2300 Chassis . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-4
4-4
4-3
4-2
.3-57
.3-54
.3-51
.3-49
.3-47
.3-46
.3-46
.3-40
.3-40
.3-31
.3-31
3-28
.3-28
.3-24
.3-18
.3-16
.3-12
.3-11
3-7
3-7
3-6
3-5
3-4
3-3
3-2
2-2
1-9
1-6

List of Figures
x255-700-714R11.0
PacketStar®PSAX 1-Port Channelized OC-3/STM-1 CES Module User Guide, Issue 1 Release 11.0.0
4-4 Loopback Configuration Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-5
4-5 Console Interface Main Menu (Equipment Configuration Selected) . . . . . . . . . . . . . . . . . . . . 4-6
4-6 Sample Equipment Configuration Window on a PSAX 4500 System (Page 1) . . . . . . . . . . . . 4-7
4-7 Sample Equipment Configuration Window on a PSAX 1000, PSAX 2300, or PSAX 4500
System (Page 2) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-7
4-8 Channelized OC-3 SM Port Configuration Window (Before Configuration) . . . . . . . . . . . . . 4-12
4-9 Channelized STM-1 Port Configuration Window (After the Apply
Port Configuration Command Is Applied) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-12
4-10 Channelized STM-1 SM AU-3 Port Configuration Window . . . . . . . . . . . . . . . . . . . . . . . . . 4-17
4-11 Channelized STM-1 SM Virtual E1 Port and Channel Configuration Window . . . . . . . . . . . . 4-19
4-12 Channelized STM1 Virtual E1 Channel Configuration Window - the Channelization Disabled by
Default . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-24
4-13 Channelized STM-1 SM Virtual E1 Port and Channel Configuration
Window (Channelization Enabled) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-28
4-14 Strapped Channels 1 Through 5 Displaying After Apply Configuration Command Has
Been Applied . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-33
4-15 Displays Strapped E1 DS0 Channels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-34
4-16 Module Configured for 1+1 Protection (Working Module) . . . . . . . . . . . . . . . . . . . . . . . . . 4-36
4-17 Channelized STM-1 SM MSP Configuration Window (Before Configuration) . . . . . . . . . . . . 4-36
4-18 Channelized STM-1 SM AU-3 Port Configuration Window . . . . . . . . . . . . . . . . . . . . . . . . . 4-45
4-19 Higher Order Path Trace - J1 Byte Configuration Window . . . . . . . . . . . . . . . . . . . . . . . . . . 4-45
4-20 Channelized STM-1 SM AU-3 Port Configuration Window . . . . . . . . . . . . . . . . . . . . . . . . . 4-51
4-21 Channelized STM-1 SM Virtual E1 Port Configuration Window . . . . . . . . . . . . . . . . . . . . . . 4-51
4-22 Save Configuration [Modified] (Before Saving) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-54
4-23 Channelized STM-1 Port Statistics Window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-56
4-24 Channelized STM-1 SM AU-3 Port Statistics Window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-59
4-25 Channelized OC-3 STS1 Port Configuration Window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-61
A-1 Combining the UPC Feature and Either the TS or VI Feature on a Connection . . . . . . . . . . . A-12
A-12
4-61
4-59
4-56
4-54
4-51
4-51
4-45
4-45
4-36
4-36
4-34
4-33
4-28
4-24
4-19
4-17
4-12
4-12
4-7
4-7
4-6
4-5

255-700-714R11.0 xi
PacketStar®PSAX 1-Port Channelized OC-3/STM-1 CES Module User Guide, Issue 1 Release 11.0.0
List of Tables
1-1 Text Conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-5
1-2 Command Description Table Example . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-6
1-3 System Responses to Selecting Options, Fields, or Commands . . . . . . . . . . . . . . . . . . . . . . . .1-7
1-4 Shortcut Keys for Navigating Console Interface Windows . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-7
2-1 Physical Hardware Specifications for the PSAX I/O Module . . . . . . . . . . . . . . . . . . . . . . . . . . .2-3
2-2 1-Port Channelized OC-3/STM-1 CES Module Optical Specifications . . . . . . . . . . . . . . . . . . . .2-4
2-3 Performance and Power Specifications for the Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-5
2-4 LED Indicators for the 1-Port Channelized OC-3/STM-1 CES Modules . . . . . . . . . . . . . . . . . . .2-6
3-1 Equipment Configuration Window Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-8
3-2 Equipment Configuration Window Field Descriptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-8
3-3 Alarm Status Descriptions for Modules on the Equipment Configuration Window . . . . . . . . .3-9
3-4 Channelized OC-3 Port Configuration Window Commands . . . . . . . . . . . . . . . . . . . . . . . . .3-12
3-5 Channelized OC-3 or STM-1 CES Port Configuration Window Field Descriptions . . . . . . . . . .3-13
3-6 Channelized OC-3 STS-1/STM-1 AU-3 Port Configuration Window Commands . . . . . . . . . .3-17
3-7 Channelized OC-3/STM-1 STS-1/AU-3 Port Configuration Window Field Descriptions . . . . . .3-17
3-8 Channelized OC-3 Virtual DS1 Port Configuration Window Commands . . . . . . . . . . . . . . . .3-18
3-9 Channelized OC-3 SM Virtual DS1 Port Configuration Window
Field Descriptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-19
3-10 Channelized OC-3/STM-1 Virtual DS1/E1 Channel Configuration Window Commands . . . . .3-24
3-11 Channelized OC-3/STM-1 Virtual DS1/E1 Channel Configuration Window
Field Descriptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-25
3-12 Channelized OC-3/STM-1 Virtual DS1/E1 DS0s Strap Display Window Commands . . . . . . . .3-29
3-13 Channelized OC-3/STM-1 Virtual DS1/E1 DS0s Strap Display Window
Field Descriptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-29
3-14 Channelized OC-3STM-1 APS/MSP Configuration Window Commands . . . . . . . . . . . . . . . .3-31
3-15 Channelized OC-3 MM APS Configuration Window Field Descriptions . . . . . . . . . . . . . . . . .3-32
3-16 Channelized OC-3 or STM-1 CES Port Configuration Window Field Descriptions . . . . . . . . . .3-36
3-17 Higher Order Path Trace - J1 Byte Configuration Window Commands . . . . . . . . . . . . . . . . .3-40
3-18 Higher Order Path Trace - J1 Byte Configuration Window Field Descriptions . . . . . . . . . . . .3-41
3-19 Channelized OC-3 or STM-1 CES Port Configuration Window Field Descriptions . . . . . . . . . .3-42
3-20 Lower Order Path Trace -J2 Byte Configuration Window Commands . . . . . . . . . . . . . . . . . .3-47
3-21 Lower Order Path Trace - J2 Byte Configuration Window
Field Descriptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-47
3-22 Messages Generated after the Save Configuration Process . . . . . . . . . . . . . . . . . . . . . . . . . .3-49
3-23 Channelized OC-3/STM-1 Port Statistics Window Commands . . . . . . . . . . . . . . . . . . . . . . . .3-51
3-24 1-Port Channelized OC-3/STM-1 CES Port Statistics Window Field Descriptions . . . . . . . . . . .3-51
3-25 Channelized OC-3/STM-1 Virtual DS1/E1 Port Statistics Window Commands . . . . . . . . . . . .3-54
.3-54
.3-51
.3-51
.3-49
.3-47
.3-47
.3-42
.3-41
.3-40
.3-36
.3-32
.3-31
.3-29
.3-29
.3-25
.3-24
.3-19
.3-18
.3-17
.3-17
.3-13
.3-12
3-9
3-8
3-8
2-6
2-5
2-4
2-3
1-7
1-7
1-6
1-5

List of Tables
xii 255-700-714R11.0
PacketStar®PSAX 1-Port Channelized OC-3/STM-1 CES Module User Guide, Issue 1 Release 11.0.0
3-26 Channelized OC-3 Virtual DS1 Port Statistics Window Field Descriptions . . . . . . . . . . . . . . . 3-55
3-27 Channelized OC-3/STM-1 STS1/AU-3 Port Statistics Window Commands . . . . . . . . . . . . . . 3-57
3-28 Channelized OC-3/STM-1 STS1/AU-3 Port Statistics Window Field Descriptions . . . . . . . . . . 3-57
4-1 Equipment Configuration Window Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-8
4-2 Equipment Configuration Window Field Descriptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-8
4-3 Module Alarm Status Descriptions on the Equipment Configuration Window . . . . . . . . . . . . 4-9
4-4 Channelized OC-3 Port Configuration Window Commands . . . . . . . . . . . . . . . . . . . . . . . . 4-13
4-5 Channelized OC-3 or STM-1 CES Port Configuration Window Field Descriptions . . . . . . . . . 4-13
4-6 Channelized OC-3 STS-1/STM-1 AU-3 Port Configuration Window Commands . . . . . . . . . . 4-17
4-7 Channelized OC-3/STM-1 STS-1/AU-3 Port Configuration Window Field Descriptions . . . . . 4-18
4-8 Channelized STM-1 SM Virtual E1 Port and Channel Configuration
Window Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-19
4-9 Channelized STM-1 SM Virtual E1 Port and Channel Configuration Window
Field Descriptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-20
4-10 Channelized OC-3/STM-1 Virtual DS1/E1 Channel Configuration Window Commands . . . . 4-24
4-11 Channelized OC-3/STM-1 Virtual DS1/E1 Channel Configuration Window
Field Descriptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-25
4-12 Channelized STM-1 SM Virtual E1 Port and Channel Configuration
Window Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-28
4-13 Channelized STM-1 SM Virtual E1 Port and Channel Configuration Window
Field Descriptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-29
4-14 Channelized OC-3/STM-1 Virtual DS1/E1 DS0s Strap Display Window Commands . . . . . . . . 4-34
4-15 Channelized OC-3/STM-1 Virtual DS1/E1 DS0s Strap Display Window
Field Descriptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-34
4-16 Channelized OC-3STM-1 APS/MSP Configuration Window Commands . . . . . . . . . . . . . . . . 4-36
4-17 Channelized STM-1 SM MSP Configuration Window Field Descriptions . . . . . . . . . . . . . . . . 4-37
4-18 Channelized OC-3 or STM-1 CES Port Configuration Window Field Descriptions . . . . . . . . . 4-41
4-19 Higher Order Path Trace - J1 Byte Configuration Window Commands . . . . . . . . . . . . . . . . . 4-45
4-20 Higher Order Path Trace - J1 Byte Configuration Window
Field Descriptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-46
4-21 Channelized OC-3 or STM-1 CES Port Configuration Window Field Descriptions . . . . . . . . . 4-47
4-22 Lower Order Path Trace -J2 Byte Configuration Window Commands . . . . . . . . . . . . . . . . . . 4-52
4-23 Lower Order Path Trace - J2 Byte Configuration Window
Field Descriptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-52
4-24 Messages Generated after the Save Configuration Process . . . . . . . . . . . . . . . . . . . . . . . . . 4-54
4-25 Channelized OC-3/STM-1 Port Statistics Window Commands . . . . . . . . . . . . . . . . . . . . . . . 4-56
4-26 1-Port Channelized OC-3/STM-1 CES Port Statistics Window Field Descriptions . . . . . . . . . . 4-56
4-27 Channelized OC-3/STM-1 STS1/AU-3 Port Statistics Window Commands . . . . . . . . . . . . . . 4-59
4-28 Channelized OC-3/STM-1 STS1/AU-3 Port Statistics Window Field Descriptions . . . . . . . . . . 4-59
4-29 Channelized OC-3/STM-1 Virtual DS1/E1 Port Statistics Window Commands . . . . . . . . . . . . 4-61
4-30 Channelized STM-1 SM/MM Virtual E1 Port Statistics Window Field Descriptions . . . . . . . . . 4-62
A-1 Connection Type by Interface Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-2
A-2
4-62
4-61
4-59
4-59
4-56
4-56
4-54
4-52
4-52
4-47
4-46
4-45
4-41
4-37
4-36
4-34
4-34
4-29
4-28
4-25
4-24
4-20
4-19
4-18
4-17
4-13
4-13
4-9
4-8
4-8
3-57
3-57
3-55

List of Tables
255-700-714R11.0 xiii
PacketStar®PSAX 1-Port Channelized OC-3/STM-1 CES Module User Guide, Issue 1 Release 11.0.0
A-2 Interface Type by I/O Module Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-4
A-3 Module Alarm Status Descriptions on the Equipment Configuration Window . . . . . . . . . . . . A-7
A-4 Standard (Multiplexed) AAL2 Bandwidth Calculation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-8
A-5 Non-Multiplexed AAL2 Transmission Rates . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-9
A-6 Standard AAL2 Bandwidth Calculation for Fax Relay Mode Using DSP AlgoSets 4 or 6 . . . . . A-9
A-7 PSAX System-Supported Quality of Service Categories . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-10
A-8 Mapping ATM Service Categories to PSAX System Priority Levels . . . . . . . . . . . . . . . . . . . . A-10
A-9 ATM Traffic Shaping, UPC Support, and VI Support Configuration Compatibility . . . . . . . . A-11
A-10 ATM Traffic Shaping CPS Calculation Table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-12
B-1 Optical Specifications for the Single-Mode Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .B-4
B-4
A-12
A-11
A-10
A-10
A-9
A-9
A-8
A-7
A-4

List of Tables
xiv 255-700-714R11.0
PacketStar®PSAX 1-Port Channelized OC-3/STM-1 CES Module User Guide, Issue 1 Release 11.0.0

PacketStar®PSAX 1-Port Channelized OC-3/STM-1 CES Module User Guide, Issue 1 Release 11.0.0
255-700-714R11.0 1-1
1Getting Started
Purpose of This Guide
The PacketStar®PSAX 1-Port Channelized OC-3/STM-1 CES Module User Guide
provides a description of the 1-Port Channelized OC-3/STM-1 CES. It also
provides information on how to configure the module ports and channels.
The PacketStar®PSAX 1-Port Channelized OC-3/STM-1 CES Module User Guide
provides a description of the 1-Port Channelized OC-3/STM-1 CES modules
(23N12 (MM)/23N13 (SM)). It also provides information on how to config-
ure the module ports and channels.
For information on configuring interfaces and provisioning connections
through the PSAX console interface, see the PacketStar®PSAX Connections Pro-
visioning Guide. If the Navis®EMS-PSAX interface is being used, see the
Navis®EMS-PSAX Interface and Connection Provisioning Guide.
Note: If you are using this module for the first time, you should read
through this guide in its entirety before beginning the configura-
tion process. The chapters in this guide are arranged in the logical
order of normal configuration and should be performed in that
order for the module to operate successfully.
Audience for This Guide
The information in this guide is intended for users who will configure ports
and channels for the 1-Port Channelized OC-3/STM-1 CES modules, in the
PSAX Multiservice Media Gateway system.
The information in this guide is intended for users who will configure ports
and channels for the 1-Port Channelized OC-3/STM-1 CES in the PSAX Mul-
tiservice Media Gateway system.
What You Should Know
Before you use this document or operate a PSAX system, you should already
understand and have experience with the following:
•ATM Forum, Frame Relay Forum, and other telecommunications specifica-
tions
•Ethernet network capabilities
•Internet Protocol capabilities
•Data network design
•Telephony network design

Chapter 1 Getting Started
Related Reading
1-2 255-700-714R11.0
PacketStar®PSAX 1-Port Channelized OC-3/STM-1 CES Module User Guide, Issue 1 Release 11.0.0
Related Reading
Product Information Library
To install, operate, and configure your PSAX system and I/O and server mod-
ules, read the PSAX publications provided on your Lucent Technologies
PacketStar®PSAX Multiservice Media Gateways Product Information Library
CD-ROM.
Printed Documents
For your convenience, many of the documents included on the PacketStar®
PSAX Multiservice Media Gateways Product Information Library CD-ROM are also
available in printed form. You can order these documents through the Lucent
Technologies Customer Information Center Web site at:
http://www.lucentdocs.com.http://www.lucentdocs.com.
Other Publications
Numerous books are currently available on the subject of basic telecommuni-
cations technology and specific protocols. In addition to such general reading,
you should also be familiar with the industry specifications identified in this
guide.
About Lucent Technologies
Lucent Technologies is the communications systems and technology com-
pany formed through the restructuring of AT&T. We bring with us a tradition
of more than 125 years of experience and a dedication to superior customer
service.
Lucent Technologies manufactures, sells, and services a complete line of cus-
tomer premises communications units, and commercial and multimedia
communications and messaging systems designed and supported by our
research and development unit, Bell Laboratories.
Our legacy and our spirit of innovation allow Lucent to provide our custom-
ers with the tools needed to communicate effectively, any time and any-
where, and to integrate the latest technologies into real-life solutions that
help make business work.
About the PacketStar PSAX Product Family
Lucent Technologies provides a complete range of PSAX Multiservice Media
Gateways in the PacketStar PSAX family.

255-700-714R11.0 1-3
PacketStar®PSAX 1-Port Channelized OC-3/STM-1 CES Module User Guide, Issue 1 Release 11.0.0
Chapter 1 Getting Started
About the PacketStar PSAX Product Family
PSAX 1000 Multiservice Media Gateway
The PacketStar PSAX 1000 Multiservice Media Gateway is designed to provide
a full range of central office-based multiservice media gateway functions in a
small, competitively-priced package suitable for customer premise deploy-
ment. Ideal for central office, large enterprise, or wireless cell site multiser-
vice media gateway applications, the PSAX 1000 system provides highly reli-
able network access for time-division multiplex voice, frame relay,
10/100BASE-T Ethernet, and ATM data applications.
When it is functioning in a redundant operating mode and after it has experi-
enced a single-point failure, the PSAX 1000 system provides up to 630 Mbps
of ATM cell bus capacity. The total ATM cell bus capacity of the system may
also be scaled to provide nonblocking, nonredundant chassis bandwidths
beyond 630 Mbps.
Supporting up to five slots (19–inch chassis) for I/O and server mod-
ules—with a full range of interfaces such as DS0A, DS1/E1, DS3/E3, OC-3,
OC-3c/STM-1, OC-12c/STM-4c, 10/100BASE-T Ethernet, and serial—the
PSAX 1000 system is a cost-effective access switch solution for connecting to
legacy equipment.
PSAX 1250 Multiservice Media Gateway
The PacketStar PSAX 1250 Multiservice Media Gateway is designed to provide
a full range of central office-based multiservice ATM access functions. Ideal
for the central office or a large enterprise’s multiservice media gateway, the
PSAX 1250 system provides highly reliable network access for time-division
multiplex voice, frame relay, 10/100BASE-T Ethernet, and ATM data applica-
tions.
When it is functioning in a redundant operating mode and after it has experi-
enced a single-point failure, the PSAX 1250 system provides up to 600 Mbps
of ATM cell bus capacity. The total ATM cell bus capacity of the system may
also be scaled to provide nonblocking, nonredundant chassis bandwidths
beyond 600 Mbps.
Supporting 10 slots (19-inch chassis) or 14 slots (23-inch chassis) for I/O and
server modules—with a full range of interfaces such as DS0A, DS1/E1,
DS3/E3, OC-3, OC-3c/STM-1, OC-12c/STM-4c, 10/100BASE-T Ethernet,
and serial—the PSAX 1250 system is a cost-effective access switch solution
for interworking with legacy equipment.
PSAX 2300 Multiservice Media Gateway
The PacketStar PSAX 2300 Multiservice Media Gateway offers carrier-grade,
high-density multiservice ATM access functions. Designed as the multiservice
media gateway for the central office or for a large enterprise customer, the
PSAX 2300 system provides network access for time-division multiplex
voice, frame relay, 10/100BASE-T Ethernet, and ATM data applications.

Chapter 1 Getting Started
Document Conventions
1-4 255-700-714R11.0
PacketStar®PSAX 1-Port Channelized OC-3/STM-1 CES Module User Guide, Issue 1 Release 11.0.0
When it is functioning in a redundant operating mode and after it has experi-
enced a single-point failure, the PSAX 2300 system provides up to 1.9 Gbps
of ATM cell bus capacity. The total ATM cell bus capacity of the system may
also be scaled to provide nonblocking, nonredundant chassis bandwidths
beyond 1.9 Gbps.
Supporting 15 slots for I/O and server modules—with provisions for OC-3,
OC-3c/STM-1, and OC-12c/STM-4c interfaces with 1:1 protection, 1:1 DS1
module protection switching, and a full range of interfaces such as DS0A,
DS1/E1, DS3/E3, 10/100BASE-T Ethernet, and serial—the PSAX 2300 sys-
tem solves demanding and diverse network design challenges with ease.
PSAX 4500 Multiservice Media Gateway
The PacketStar PSAX 4500 Multiservice Media Gateway provides carrier-class
reliability, with an unmatched range of service capabilities, end-to-end traffic
prioritization, “any-service, any-channel” flexibility, and breakthrough voice
technology. Ideal for the central office or a large enterprise multiservice
media gateway, the PSAX 4500 system provides highly reliable network
access for time-division multiplex voice, frame relay, 10/100BASE-T Ether-
net, and ATM data applications.
When it is functioning in a redundant operating mode and after it has experi-
enced a single-point failure, the PSAX 4500 system provides up to 4.2 Gbps
of ATM cell bus capacity. The total ATM cell bus capacity of the system may
also be scaled to provide nonblocking, nonredundant chassis bandwidths
beyond 4.2 Gbps.
The high-performance midplane design supports 15 interface slots. Module
protection for two groups of four or six multiport DS3, STS-1e, or E3 mod-
ules is provided via an N:1 protection scheme using rear access line interface
modules. The protection module provides backup so that on the failure of
any one of the modules in a group, traffic is maintained. A single PSAX 4500
system at the edge of the carrier network can transition traffic from a large
number of network customers over high-speed DS1/E1 IMA, DS3/E3, OC-3,
OC-3c/STM-4c, and OC-12c/STM-4c trunks into the ATM core, managing
the whole quickly and efficiently, down to the individual permanent virtual
circuit.
Through the use of the latest DSP voice technology, the PSAX 4500 system
supports advanced voice traffic over ATM (VToA) services for up to 6048 DS0
channels. As a multiservice media gateway—with H.248 call control, CAS,
PRI, GR-303, and V5.2 protocols, 3-Port DS3/STS-1e, 1-Port OC-3/STM-1
CES, and Tones and Announcements modules—the PSAX 4500 system pro-
vides packet solutions for voice over xDSL, trunking, tandem, and PRI offload
switching.
Document Conventions
Text Types Used in This Document
Table 1-1 shows how each typographical convention is used.

255-700-714R11.0 1-5
PacketStar®PSAX 1-Port Channelized OC-3/STM-1 CES Module User Guide, Issue 1 Release 11.0.0
Chapter 1 Getting Started
Document Conventions
Icons and Symbols
Refer to the procedures within this guide for important safety information
and proper procedures.
Standard icons and symbols to alert you to dangers, warnings, cautions, and
notes are described as follows:
!
DANGER:
Warnings for a personal injury hazard are identified by this format.
WARNING:
!
Warnings relating to risk of equipment damage or failure are identified
by this format.
!CAUTION:
Warnings relating to risk of data loss or other general precautionary
notes are identified by this format.
Note: Identifies additional information pertinent to the text preceding
this note.
Use of Command Description Tables
All illustrations for configuration windows in this guide for the PSAX system
console interface are followed by a command description table describing the
command functions displayed on the window (near the bottom of the win-
dow). You should read all the information in the command description table,
especially when first using a window, because these descriptions may have
special instructions or configuration constraints provided in the Function col-
umn by use of the Note: text convention (see Table 1-2).
Table 1-1. Text Conventions
Appearance How it is used
SANS SERIF BOLD, ALL CAPS Labels on module panels, chassis faceplates, or other
hardware
Fixed-width normal Message text displayed on the user interface window
Serif bold •Button name (GUI interface) or command name
(console interface) on the user interface window
•Literal text for values that the user types or selects
from predefined sets of values for fields
•Commands or literal argument values
Fixed-width bold System prompts displayed on the user interface window
Serif italics •A variable name or string for which you will substi-
tute your own information
•An argument or parameter on a command line for
which you will substitute your own information

Chapter 1 Getting Started
General Document Navigational Guidelines
1-6 255-700-714R11.0
PacketStar®PSAX 1-Port Channelized OC-3/STM-1 CES Module User Guide, Issue 1 Release 11.0.0
Use of Field Description Tables
For all illustrations for configuration windows in this guide for both the
PSAX system console interface and the EMS-PSAX, the field description
tables normally follow the command description tables. Field description
tables define the editable and the display-only fields, their functions, valid
values, and constraints, if applicable. As in the command description tables,
the Note: text convention is also used, where appropriate, in the field descrip-
tion tables to alert the user to special instructions or configuration constraints
(see Figure 1-1).
General Document Navigational Guidelines
Selecting Options, Fields, and Commands Using the Console Interface
Follow these guidelines to select an option, field, or command on the PSAX
console interface windows and to navigate through the windows:
•To select an option, field, or command, do one of the following:
Table 1-2. Command Description Table Example
Command Function
Bring All Interfaces
Into Service
Brings the out-of-service configured interfaces to in-service status.
Note: In GR-303 configuration, it is critical to bring into service
only those channels actively configured with DS1 ports.
Figure 1-1. Field Description Table Example
Field Name Field Values Description
Interface Type Default: 0
Range: 0-22
Format: Numeric
Specifies the type of end-to-end connection
protocol that governs the transmission parameters
for this configured port and channel interface.
Note: When certain types of interfaces are select-
ed in this field, other configuration fields are dis-
played on this window.
Identifies editable fields
or display-only fields on
screens
Identifies initial field
value default
Describes the function of the field
and special instructions for
configuring modules
Identifies available
range for field value
when applicable
Identifies field value format as
Numeric, Predefined Alphanumeric,
Hexadecimal, or Valid Dotted Quad.
Decribes special instructions or
configuration constraints
This manual suits for next models
2
Table of contents
Other Lucent Control Unit manuals