Common Faults and Troubleshoot
The controller outputs about 512-800 points on each port, and no more than 800pcs on each port. Each port is
independently equipped with a power supply, which is not Shared with other ports.
The Standard Packing Quantity of RGB lights is 30pcs,and each string must be connected to the power supply.
The power wire should be 2.5 square meters of national standard multi-core pure copper wire.Make sure the correct
connection of positive and negative poles between led module and power supply,Treat the Exposed wires with
insulation arrangement
The controller needs to choose the products of regular manufacturers, and the signal output to the lamp must use our
special signal extension wire, not inferior network cable, common cable or telephone wire.
The power supply must have short circuit protection, overvoltage protection, overload protection and other functions,
the output voltage must be the same as the working voltage of the lamp string, the rated load power must reserve
20% of the margin.
The lightning protection scheme, leakage protection, timing and other supporting works of the overall project shall be
designed and constructed by professional departments.The resulting product problems do not belong to the scope of
our warranty.
Product life span under normal usage
If the product is damaged due to its own quality problems within the warranty period (excluding improper use,
accessories and force majeure, etc.), our company will refund and replace the damaged products
Please read this instruction carefully before using the product
Do not do live-line working during installation,Make sure the input voltage meets the requirements and lines are
connected correctly before lighting on.
Installation, maintenance and repair should be operated by a qualied technician.
This product will generate heat when working, considered to choose the material with good heat dissipation
performance
The data given in this instruction manual is based on the standard product. Please refer to the actual product for
details
All the pictures of products in this manual are schematic diagrams. For details, please refer to the actual
products. The final interpretation right of this manual belongs to Lucoled NV.
Lucoflex
RGB-DC
Manual
Automatic power protection from the open or
short circuit in output of the power supply
wrong IC model for the controller
The signal cables are ordinary cables
Check the circuit for short circuits
Conrm IC model rewrite program
Replace the network cable with
shielding function
Check wiring is correct
Wrong connection of power supply.
The controller and the wire of the lamp are
connected incorrectly.
The lamp is overloaded
Check the correctness of positive
and negative connection
green line and blue line DATA ,black
line GND
2.5 square meters of national
standard multi-core pure copper wire
Check if the line is connected to the
power supply
Some IC do not light up when they are charged
The lamp is not installed in the right way
The power supply is poor and unstable
Two power supplies per port
The signal cables are ordinary cables
The lamp is overloaded
The power supply is poor and unstable
Low IC chip quality
Induction short circuit or lamp not waterproof
Poor contact due to rusting of lamp board
Cold and heat shock causes poor IC signal
Some switching mode power supplies are
not powered.
Wrong connection of power supply.
Check IC model
Check the wiring
Replace high quality power supply
One power supply per port
Replace the lamp
Replace the lamp
Replace the lamp
Replace the regular light string
manufacturers
Check the lamp board for rust
Choose the manufacturer of
waterproof lamp board
Choose IC high protection
manufacturers
Problems
All LEDs can not
light on.
Picture shaking and
clutter
picture shake and
icker
Signal instability
Single lamp no signal
single lamp ickers dim
Abnormal color of
single lamp
repaired every month
no signal when it rains
No signal for half a
year
High signal failure rate
in winter
LEDs can not light
on partly
Reasons Solutions