Warranty:
LumaDent, Inc. warrants every product to be free of manufacturer
defects and will repair or replace any product found to be
defective.
Two-Year Limited Warranty:
● LED Headlamp
● Any mount or attachment mechanism
One-Year Limited Warranty:
● Battery Pack
● Smart Charger
● Composite Filter
Six-Month Limited Warranty:
● Control Cable
Limitations of Warranty:
● Breakage or failure due to tampering, misuse, neglect,
accidents, dropping, or modification.
● If product is not used in accordance to recommendations or
instructions provided by LumaDent, Inc.
● If repaired or serviced by anyone other than LumaDent, Inc.
Intended use: To illuminate observing area without physically
contacting patient.
Application site: Hospitals and Clinics
Caution:
● Avoid shining light directly in eyes.
● Do not immerse any components in liquid.
● Properly dispose of old/non-working batteries at your local
recycling site.
For any questions or problems, please contact our Solution Team
at (775) 829-4488. Mon-Fri from 7:00 am-5:00 pm (Pacific Time)
or visit our support page at www.LumaDent.com/support
LumaDent, Inc.
10593 Double R Blvd.
Reno, NV 89521
Instruction Manual
ProLUX LED Headlight System
www.LumaDent.com
(775) 829-4488
2. Wire Management
a) Use the provided O-rings to secure the control switch to the frame temple
arm. This will minimize twisting, pulling, and pushing of the wire.
Run the remaining wire down your back, using the included wire clips to
secure it to your lab coat or scrubs.
5. Charging ProLUX Battery:
a) When the Smart Charger is plugged into a power outlet, a GREEN light
on the charger will indicate the charger is working.
b) When the charger is connected to the bottom of the battery pack, a
RED light on the charger will indicate the battery is charging.
c) When the battery is fully charged, the light on the charger will turn
GREEN once again.
Included:
● HL360 Headlamp
(Neutral or Warm)
● ProLUX Battery/ies
● 2x ProLUX Control Cables
● Smart Charger
● Custom Mount
● Accessories Kit
● Composite Filter
1. Attaching/Adjusting Headlamp
a) For instructions on installing your headlamp to your specific loupes, please
visit www.LumaDent.com/instructions
b) All LumaDent mounts articulate both left/right and up/down. Use the
provided hex key to tighten/loosen screws as needed.
4. Light Function (Control Switch or Battery Switch):
a) Tap the control or battery switch ONCE to turn
the light on/off.
b) Press and hold the control or battery switch to
cycle between 1 of 4 intensity settings.
c) Release the control or battery switch on desired
intensity setting.
3. Composite Filter:
a) Slide composite filter over the headlamp prior to composite procedure.
b) Use handle of the mouth mirror or other instrument to swivel orange shield
down, then place composite.
c) After placing composite, use the mirror handle to swivel orange shield back up.
6. Cleaning:
a) To clean the lens, use any lens cleaner and a microfiber cloth to wipe
lens clean.
b) To clean the wire, use disinfectant spray on a 4”x4” gauze (or similar)
and wipe wire clean.
NOTE: The headlamp is removable
via our “Detachable Linkage Arm”.
This conveniently allows removal of
headlamp without removing mount
from loupes.
Note: The scrub clip can
be moved by threading
the wire through the
plastic piece, making
loop bigger. Once in
position, pull wire from
opposite side to make
loop small again.
Battery Level Meter:
4 LED lights on the top of battery will turn RED, indicating battery level, when
button is pressed.
Battery Specifications:
● Charging Time: 3 hours (Full charge)
● Battery Life: 15-40 hours
● Intensity Control: 4 Preset Intensities
Precautions:
● Use only the provided charger to charge the battery.
● Do not charge the battery overnight/unattended.
● Do not drop, immerse in liquids, or store near hot areas.
● If battery acts abnormally, discontinue use and contact us right away..
● Recommended to use light on medium to high intensity to reduce eye
strain.

Popular Medical Equipment manuals by other brands

AGFA DX-D 10C user manual

AGFA

AGFA DX-D 10C user manual

Maquet Axcel AXL 5001 user manual

Maquet

Maquet Axcel AXL 5001 user manual

Med-Mizer EX5000 user manual

Med-Mizer

Med-Mizer EX5000 user manual

Jolife LUCAS Instructions for use

Jolife

Jolife LUCAS Instructions for use

Medela Thopaz Quick reference guide

Medela

Medela Thopaz Quick reference guide

Ivoclar Vivadent Programat P310 operating instructions

Ivoclar Vivadent

Ivoclar Vivadent Programat P310 operating instructions

ZOLL R Series Operator's guide

ZOLL

ZOLL R Series Operator's guide

ACP Synchrony user manual

ACP

ACP Synchrony user manual

Xstrahl 100 Operator's manual

Xstrahl

Xstrahl 100 Operator's manual

Otto Bock 4023 Manu Rheuma Instructions for use

Otto Bock

Otto Bock 4023 Manu Rheuma Instructions for use

MedaCure DS1100 user manual

MedaCure

MedaCure DS1100 user manual

KaWe EUROLIGHT D30 2.5 V user manual

KaWe

KaWe EUROLIGHT D30 2.5 V user manual

CenterLine Balanced Body Assembling

CenterLine

CenterLine Balanced Body Assembling

Chattanooga LIGHTFORCE XLi Instructions for use

Chattanooga

Chattanooga LIGHTFORCE XLi Instructions for use

Petermann Bathlift Peter Pan PM IV Long manual

Petermann

Petermann Bathlift Peter Pan PM IV Long manual

miniland nasal care manual

miniland

miniland nasal care manual

Levabo Seat All Flexi quick start guide

Levabo

Levabo Seat All Flexi quick start guide

Carestream Focus HD 35 user manual

Carestream

Carestream Focus HD 35 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.