Lumos X-Loupe Inspection Task Lighting User manual

④
① ③
②
⑦
Footswitch pedal
(option)
⑤
⑥
⑦ Power / signal & control cable
LED Light bar
position knob
(three-lobe knob)
Light bar (back) Control Unit (front)
⑤ ⑦⑥
Control Unit (back)
Control Unit
① Power ON / OFF
② LCD status display LCD
•Show the status of Battery / lighting position /
lighting intensity digital
③ Control knob (illumination intensity)
•Stepless illumination Intensity
is dimmable from 1~100%
•Default setting 50%
④ Light source switching / Default lightness push button
•Sequentially toggle the switch to change light source
(standard 2-channel: Green / 4000k White)
•Directly press the switch to reply the illumination
intensity default setting (50%)
⑤ DC power supply
⑥ Cable port (for Footswitch pedal)
⑦ Power / signal & control cable
Light bar AC to DC voltage converter
Flat-base Stand
45°
25°
23°
Note:
The illumination angle of the light bar
on the bracket is adjustable
(sliding track for up and down is about
23° / lighting bar is rotatable for 45°)
Installation instruction (I)
Lamp Holder Set A (Light bar / Light shielding Plate to Flat-base Stand)
1. From the upper entrance of sliding track get the Light Bar placed, as shown in
Figure (1).
2. Attach the gasket and the position Knob (for Light Bar) to the threaded rod
protruding from light bar. Adjust the light bar to the desired position and tighten it,
as shown in Figure (2).
3. Place the metal plate on the top of the Flat-base Stand, align the screw holes and
insert the 4 screws (Set A, Hexagon Socket Cap Screws) to the corresponding
holes and tighten them, as shown in Figure (3).
4. Insert the fixed screw (for light shielding plate) through the gasket; align the holes
of light shielding plate to the upper holes on the sides of the flat-base stand, and
then insert the fixed screw to the hole and tighten it, as shown in Figure (4).
Light shielding plate
Light shielding plate fixed screw
(1)
(2)
(3)
(4)
Metal plate Screws(A)
LED Light bar position knob
(three-lobe knob)
〈Combination for Control unit and Frame bracket〉
1.Remove the lower right screws (Set B, Cross recessed Flat-Head Screw) from tapped holes of the left and right sides of the Control unit as
shown in the Figure(5); place the Control unit on the top of the frame bracket, reinsert another set of screws (Set C, Hexagon Socket Cap
Screws) to the corresponding holes and tighten them. (Note: Keep the two screws of Set A for next use)
〈Combination for Light Bar / Light shielding plate and Frame bracket〉
2.Insert the threaded rod protruding of light bar to the hole on the sides of the frame bracket as shown in the Figure(6). Attach the gasket
and the position Knob (for Light Bar) to the threaded rod protruding and tighten it.
3.Insert the fixed screw (for light shielding plate) through the gasket; align the holes of light shielding plate to the upper holes on the sides of
the frame bracket, and then insert the fixed screw to the hole and tighten it.
〈Combination for Lamp Holder Set B and VESA-mount Bracket〉
4.Align the screw holes on the back of assembled frame bracket to the rack hole of the VESA-mount Bracket (hole patterns: 100x100mm),
and then insert the screws (Set D, Hexagon Socket Cap Screws) to the hole and tighten it.
(5)
(8)
(6)
(6)
(7)
(7) VESA-mount bracket rack hole
Frame bracket
Installation instruction (II)
Lamp Holder Set B (Control unit / Light bar / Light shielding Plate to Frame Bracket / VESA-mount Bracket)
Screws(B)
Screws(B) Screws(D)
Screws(C) Screws(C)

Read all instructions and understand the warnings prior to using this product.
Failure to read and follow these safety instructions could result in fire, explosion, electrical shock or other hazard causing serious and/or fatal injury and/or property
damage. Please obey the following instructions.
1.This product is not a toy. Keep out of reach of children.
2.This device equipped high-brightness excitation LEDs; it is intense enough to injure eyes. While operating, for eyes safety, DO NOT look directly excitation light
source, or stare the leak of light at close range.
3.DO NOT leave this device near the heat source or use in a hot environment; The device has ventilation holes to prevent the internal temperature from becoming
too high. Pay attention to the running of cooling fan. DO NOT block the ventilation hole/vent hole of cooling fan.
4.Keep the device away from water or other liquids. A humid device could result in fire or electric shock. If it's wet, immediately turn off the device power, then wipe
out the liquid the device surface.
5.Turn off the LED lights when you aren’t using them.
6.Refer all servicing to your distributor. Servicing is required when the device has been damaged in any way, such as power-supply cord is damaged, liquid has been
spilled, the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped. Do NOT disassemble, alter or modify to this device.
Warning
Precautions for use
★In the interest of continually improving products, Lumos Tech. reserves the right to update or modify information contained in this manual without prior notice.
Distributor
7th floor, No.8, Wanhe St., Wenshan District,
11653 Taipei City, Taiwan, R.O.C.
TEL:886-2-2230-1168 FAX:886-2-2239-2112
e-mail:[email protected]
www.x-loupe.com
ITL-E
U
022119
Lamp Holder Set (c / w Light Bar and Control Unit )
Control Unit
Function
LCD Status Display Battery check / Lighting Position / Lighting Intensity (0 ~ 100%)
Power input DC 19V / 4.7A
Charging method With the Power adapter (DC 19V / 4.7A)
included in the product set to charge via a wall outlet
Material Steel, Aluminum
Weight 545g
Dimension(mm) 155 (L) х 115 (W) х 50(H)
Power cable length 30 cm
Operation Environment 0~40°C
Light Bar
Channel & Light source
Switchable dual light source channels
4 LED wavelengths (4000k White, Amber, Blue and Green colors)
are available for users to choose from (choose 2 from 4)
Dimming intensity Intensity is dimmable from 1% to 100% (default setting 50%)
Power Consumption 21W (Max)
Power input DC 80.2V / 0.25A
Illuminance
(White light : distance 0 cm)
Intensity (default) setting 50% : luminance >4500lux ;
Intensity setting 100% : luminance >8000lux
Dimension (mm) 320 (L) х 111 (W) х 58 (H)
Weight 1580g
Material Stainless Steel (#304)
Operation Environment 0~40°C
Bracket
Flat-base Stand VESA-mount
Material Stainless Steel (#304)
Weight 2200g 850g
Dimension (mm) 357 (L) х 295 (W) х 280(H) 357 (L) х 200 (W) х 160(H)
Table of contents
Other Lumos Lighting Equipment manuals
Popular Lighting Equipment manuals by other brands

Horizont
Horizont Euro-Blitz 208801LED instruction manual

Augenti LIGHTING
Augenti LIGHTING MERIDIAN 2 installation instructions

Thorn
Thorn ALG5-504L installation instructions

Airam
Airam OPTIMUS Mounting instructions

High End Systems
High End Systems MMS100 user manual

Kobold
Kobold DW 575 Operating instructions and useful tips